MAURY USCG vessel records Sign in
← All vessels

MAD MAX

MAD MAX is a 1993 passenger vessel (inspected). The Coast Guard has recorded 57 inspections since 1993, most recently in June 2026, along with 55 deficiencies and 1 casualty investigation in 2004.

Records from 1993 to 2026. Most recent: inspection, 1 June 2026.

Built
1993
Last inspected
1 June 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDQ9527
386272
Flag
UNITED STATES
367161750
Maury page id
psix-386272

Inspections, by type

…with no type recorded2
Years with a record 27 calendar years (1993–2026)
The 57 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)53.0 ft × 29.0 ft × 6.0 ft
Registered tonnagegross 15 / net 14
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGOLD COAST YACHTS INC · ST CROIX · built 1993
Hull materialFRP (Fiberglass)
PropulsionAuxiliary Sail
Hull shapeSail (Distinct Keel)
Hull configurationTwin Hull
Hailing portEDGARTOWN, MA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 8 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it15 - Simplified, Gross Ton
14 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ9527MMSI 367161750 · active · compulsorily equipped · granted 5 May 2026, expires 5 May 2036
WCX3872MMSI 367161750 · cancelled · compulsorily equipped · granted 22 February 2017, cancelled 29 April 2026
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 57

1 June 2026 Deficiency Check · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8385619
27 April 2026 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8356750
17 February 2026 Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8312235
22 September 2023 Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7795738
18 September 2023 Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7681015
8 September 2022 Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7548745
28 September 2021 Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7319553
21 September 2021 COI Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7316931
17 September 2020 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7062393
23 September 2019 Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6816669
19 September 2019 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6810982
5 October 2018 Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6555758
2 October 2018 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6550917
28 September 2017 Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6277336
25 September 2017 Internal Structural Exam · Examination of Repairs · Drydock Exam · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6275266
12 September 2017 Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6265192
11 September 2017 COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6261014
3 October 2016 Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6014895
16 September 2016 Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6004066
28 September 2015 Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5214866
11 September 2015 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5718282
29 September 2010 Deficiency Check · Drydock Exam
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3855424
20 September 2010 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3846839
30 September 2008 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3316099
25 September 2008 Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3316054
17 September 2007 Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3059770
14 September 2007 COI Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3048403
20 April 2007 Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 2909509
2 October 2006 Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 2791603
25 September 2006 Internal Structural Exam · Hull Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2786275
14 September 2006 Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 2770404
3 October 2005 Re-Inspection · Deficiency Check
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2506435
14 October 2004 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2220286
29 September 2004 Re-Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2207496
21 July 2004 Type not recorded
No type recorded · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2247486
1 July 2003 Re-Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1831494
28 February 2003 Deficiency Check
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1750981
23 September 2002 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1679299
16 September 2002 COI Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1676484
20 May 2002 Re-Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1618574
22 May 2001 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1064833
22 February 2001 Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1057962
3 October 2000 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1412197
28 June 2000 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 822732
17 May 1999 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1384238
23 February 1999 Plan Review "T" Boat
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1121071
6 October 1998 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1375539
10 June 1998 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1128420
18 June 1997 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1113123
1 November 1996 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1159195
27 July 1996 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 82091
15 May 1996 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1088739
14 June 1995 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 880558
14 October 1994 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1178596
9 June 1994 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1456181
15 June 1993 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 844672
28 April 1993 Hull Examination · Initial Certification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1140776

Deficiency record · 55

11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 1 June 2026 Resolved
Oceans, coastwise, limited coastwise, and Great Lakes routes. A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry—(1) Six hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.121; and(2) Six hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. Vessel had three smoke and three red flare distress signals. 46CFR180.68
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2026
Resolved 23 June 2026
Resolution: Received photo of 12 flares on board. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 June 2026 Resolved
Electrical equipment on a vessel must be installed and maintained to:(a) Provide services necessary for safety under normal and emergency conditions;(b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Multiple dead end wires behind operating console. 46CFR183.200(a)(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 June 2026
Resolution: Receievd photo of dead end wires being secured. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 1 June 2026 Resolved
The float-free link required by § 180.130(a)(1) must be:(1) Certified to meet § 160.073 in subchapter Q of this chapter, or other standard specified by the Commandant;(2) Of proper strength for the size of the life float or buoyant apparatus as indicated on its identification tag. No identification (breaking strength) tag for the installed weak link for the life floats. 46CFR180.137(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 June 2026
Resolution: Received photo of correct weak link installed on life float painter.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 22 September 2023 Resolved
A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry six hand red flare distress signals and six hand orange smoke distress signals. Six hand red flare distress signals may be substituted for the 6 hand orange smoke distress signals. Vessel's distress signals are expired. Provide new distress signals prior to carriage of passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 September 2023
Resolved 25 September 2023
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 September 2023 Resolved
A vessel not required to have a power driven fire pump must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words ‘‘FIRE BUCKET’’ must be stenciled in a contrasting color on each bucket. Vessel was missing 1 fire bucket. Provide a total of 3 fire buckets.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2023
Resolved 25 September 2023
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 September 2022 Resolved
1 Adult and 3 Child Jim Buoy Life Jackets were serviceable and require replacing. Allowed passengers will be reduced to 54 Adult and 3 Children until life jackets are replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 September 2022
Resolution: MI provided with a picture of the new lifejackets on board the vessel
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 September 2019 Resolved
The locking nut on the boom goose neck was loose. Vessel rep repaired it on the spot. The locking nut was missing a cotter pin and must have came loose over time.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 19 September 2019
Resolved 19 September 2019
Resolution: Vessel owner rectified def.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 2 October 2018 Resolved
Vessel's first aid kit has expired aspirin and eye solution. Replace with unexpired items.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 October 2018
Resolved 9 October 2018
Resolution: Vessel provided new aspirin and eye wash.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 2 October 2018 Resolved
Vessel's EPIRB hydrostatic release is expired. Vessel is restricted to 03NM from shore.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 October 2018
Resolved 5 October 2018
Resolution: Vessel provided a new EPIRB with new battery and registration.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 October 2018 Resolved
Vessel's waterlight batteries are expired. Vessel is restricted to day time operations only.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 October 2018
Resolved 10 October 2018
Resolution: Vessel provided 04 new waterlight batteries.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 2 October 2018 Resolved
Vessel's EPIRB battery does not have an expiration date. Provide a new batter or replace EPIRB. Vessel restricted to 03 NM from shore.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 October 2018
Resolved 5 October 2018
Resolution: Vessel provided a new EPIRB.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 2 October 2018 Resolved
Vessel does not have 03 - 2 1/2 gallon fire buckets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 October 2018
Resolved 5 October 2018
Resolution: Vessel provided 03 - 2 1/2 gallon fire buckets.
Personnel › Certificates/Documents/Licenses › Medical Fitness Document
Issued 11 September 2017 Resolved
Vessel's master does not have a medical fitness card.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2017
Resolved 12 September 2017
Resolution: Vessel's master provided a valid medical certificate.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 11 September 2017 Resolved
Vessel's EPIRB registration is expired. Provide registration renewal documentation.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 September 2017
Resolved 12 September 2017
Resolution: Vessel provided registration form for the vessel's EPIRB.
Lifesaving › Lifefloat › Markings
Issued 11 September 2017 Resolved
Vessel's lifefloats need to be restenciled with vessel's name.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2017
Resolved 12 September 2017
Resolution: Vessel properly labeled lifefoats with vessel's name.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 September 2017 Resolved
Vessel's medical chest had expired aspirin. Vessel is to provide unexpired aspirin.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2017
Resolved 12 September 2017
Resolution: Vessel provided unexpired medicine.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 11 September 2017 Resolved
Vessel's handrails on the port side need to be examined and tightened at the deck where the stanchion is attached to the deck. All handrails shall be examined and replaced on board the vessel at next drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 2 October 2017
Resolution: Through bolted
Fire Fighting › Fire Bucket › Quantity
Issued 11 September 2017 Resolved
Vessel is missing 02 fire buckets. Vessel is to provide 02 fire buckets along with lanyards.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2017
Resolved 12 September 2017
Resolution: Vessel provided 03 labeled fire buckets.
Sail Rigging › Deck Hardware › Shackles
Issued 16 September 2016 Resolved
Shackle on the gooseneck IWO of luff edge of sail is worn. Replace shackle in kind.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 October 2016
Resolved 27 September 2016
Resolution: Shackles has been replaced.
Sail Rigging › Deck Hardware › Shackles
Issued 16 September 2016 Resolved
Shackle on the headstay is stressed. Replace in kind.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 October 2016
Resolved 27 September 2016
Resolution: Shackle has been replaced.
Lifesaving › Lifefloat › Paddle
Issued 16 September 2016 Resolved
Label paddle with vessel's name.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 October 2016
Resolved 27 September 2016
Resolution: Vessel name has been stenciled on the paddles.
Sail Rigging › Chainplates › Fasteners
Issued 16 September 2016 Resolved
Chainplate IWO of starboard side head has a broken screw. Replace in kind.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 October 2016
Resolved 27 September 2016
Resolution: Due to the location of the screws it will cause more harm to remove entire chain plate. Vessel and MSD will continue to monitor fasteners in this area.
Sail Rigging › Deck Hardware › Shackles
Issued 16 September 2016 Resolved
Replace shackle on boom IWO clew/sail.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 October 2016
Resolved 27 September 2016
Resolution: Shackle has been replaced.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 16 September 2016 Resolved
Port side 5th stanchion hand rail from the bow is loose. Tighten bolts on the deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 October 2016
Resolved 27 September 2016
Resolution: Bolts have been secured properly.
Operations/Management › Vessel Activity › Other
Issued 16 September 2016 Resolved
Vessel does not have Preventative Maintenance Plan (PMP) as per NVIC 02-16. Vessel is to implement a PMP for sailing rigging.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 October 2016
Resolved 28 September 2017
Resolution: Vessel has a PMP for the sail rigging and is contining to grow.
Lifesaving › Lifefloat › Paddle
Issued 11 September 2015 Resolved
Paddles for life floats were found unsatisfactory. Replae paddles for life floats.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2015
Resolved 15 September 2015
Resolution: Vessel rep purchased new paddles and provided an email with pictures of the newly purchased paddles.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 11 September 2015 Resolved
labeling and markings for life ring need to be updated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2015
Resolved 11 September 2015
Resolution: Vessel rep updated the markings on the ringbuoy.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 September 2015 Resolved
renew first aid kit. First aid kit is out of date.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 September 2015
Resolved 23 September 2015
Resolution: Captian purchased new first aid kit and put it on the vessel.
Lifesaving › Visual Distress Signals (General) › Expired
Issued 11 September 2015 Resolved
Smoke/flares expired 2013. Replace smoke/flares PTCP.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 September 2015
Resolved 11 September 2015
Resolution: Vessel rep purchased new smoke/flares PTCP.
Fire Fighting › Fire Bucket › Availability
Issued 20 September 2010 Resolved
Provide three 2 1/2 gallon fire buckets I.A.W 46 CFR 181.610 (New T) or provide a hand fire pump with a capacity of at least 5 gallons per minute I.A.W 46 CFR 181.10-5 (Old T).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 September 2010
Resolved 29 September 2010
Engineering › Bilge Water Management System › Pump
Issued 20 September 2010 Resolved
Replace currently installed electric bilge pumps with UL approved electric submersible bilge pumps I.A.W 46 CFR 182.520(e)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 November 2010
Resolved 29 September 2010
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 20 September 2010 Resolved
Ensure lifejacket stowage is I.A.W 46 CFR 180.78 (distributed throughout accommodation spaces)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 September 2010
Resolved 29 September 2010
Communications › Radio Communications › EPIRB
Issued 14 September 2007 Resolved
EPIRB hydrostatic release is expired. Vessel is restircted to operations no greater than 1 NM offshore until this item is renewed with faxed reciept sent to USCG Cape Cod office.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 September 2007
Resolved 17 September 2007
Resolution: Owner purchased and installed a new Hydro-Release this date.
Engineering › Bilge Water Management System › Piping
Issued 25 September 2006 Resolved
Replace PVC used bilge piping bulkhead penetrations and valves with metallic materials in both port/stbd hulls IAW 46 CFR 182.40-1 ("Old" Subchapter T). Compliance date extended due to vessel being shrink-wrapped for winter.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2007
Resolved 20 April 2007
Resolution: Inspected and found satisfactory this date.
Engineering › Bilge Water Management System › Piping
Issued 25 September 2006 Resolved
Install protection from mechanical damage to PVC bilge piping IWO ladders in #2 voids in both port/stbd hulls. Compliance date extended due to vessel being shrink-wrapped for winter.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2007
Resolved 20 April 2007
Resolution: Inspected and found satisfactory this date.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 14 September 2006 Resolved
Both MDE did not auto shut-down upon testing fire-boy system. Fax servicing report to [name withheld] 10/15/06.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 October 2006
Resolved 2 October 2006
Resolution: Resloved by repairs conducted by Newport Shipyard and attested to on invoice # 101131 dated 9/29/06.
Documentation › Logs/Records › Logbook (official)
Issued 3 October 2005 Resolved
PROVIDE DRILL AND TEST LOG BOOK.
Action required: 705 - Other - as specified
Due 31 October 2005
Resolved 7 October 2005
Resolution: LOG BOOK PROVIDED.
Construction/Loadline › Structures › Door
Issued 3 October 2005 Resolved
PROVIDE DEAD LIGHT COVERS FOR PORT LIGHTS BELOW DECK.
Action required: 705 - Other - as specified
Due 31 October 2005
Resolved 7 October 2005
Resolution: DEAD LIGHT COVERS PROVIDED.
Fire Fighting › Fire Bucket › Quantity
Issued 3 October 2005 Resolved
PROVIDE 3 FIRE BUCKETS.
Action required: 705 - Other - as specified
Due 31 October 2005
Resolved 7 October 2005
Resolution: FIRE BUCKETS PROVIDED.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 3 October 2005 Resolved
PROVIDE SEPERATE STOWAGE FOR CHILD SIZE LIFE JACKETS.
Action required: 705 - Other - as specified
Due 14 October 2005
Resolved 7 October 2005
Resolution: CHILD LIFE JACKETS BAG PROVIDED.
Construction/Loadline › Hull › Side Shell
Issued 14 October 2004 Resolved
Install dead light covers on each port light below the main deck.
Due 27 October 2004
Resolved 7 October 2005
Resolution: COVERS PROVIDED.
Lifesaving › Liferaft Equipment › Paddle
Issued 1 July 2003 Resolved
ADD 4 -- 4' LONG PADDLES TO THE LIFEFLOATS.
Action required: 705 - Other - as specified
Due 8 July 2003
Resolved 1 July 2003
Resolution: PADDLES ORDERED.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 1 July 2003 Resolved
MARK STOWAGE LOCATION OF LIFEJACKETS.
Action required: 705 - Other - as specified
Due 8 July 2003
Resolved 1 July 2003
Resolution: SIGN ORDERED.
Documentation › Certificates/Documents
Issued 16 September 2002 Resolved
PROVIDE PROOF OF CURRENT CERTIFICATE OF DOCUMENTATION. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Action required: 705 - Other - as specified
Due 31 October 2002
Resolved 28 February 2003
Resolution: VERIFIED WITH OWNER COD VALID.
Lifesaving
Issued 18 June 1997 Resolved
REPLACE PORT AND STBD RING BUOYS.
Condition: Unknown
Due 26 June 1997
Resolved 26 June 1997
Documentation
Issued 15 May 1996 Resolved
PROVE COMPLIANCE WITH RANDOM AND PREEMPLOYMENT DRUG TESTING FOR ALL CREWMEMBERS.
Condition: Unknown
Due 10 July 1996
Resolved 10 July 1996
Lifesaving
Issued 15 May 1996 Resolved
POST LIFEJACKET DONNING PLACARD.
Condition: Unknown
Due 10 July 1996
Resolved 10 July 1996
Lifesaving
Issued 15 May 1996 Resolved
PROVIDE 2 ADDITIONAL FLOAT LIGHTS FOR LIFEFLOATS._x001C_
Condition: Unknown
Due 10 July 1996
Resolved 10 July 1996
Lifesaving
Issued 15 May 1996 Resolved
EQUIP AND CONFIGURE LIFEFLOAT PAINTER LINES IAW 46/180.137.
Condition: Unknown
Due 10 July 1996
Resolved 10 July 1996
Accommodation/Occupational Safety
Issued 15 May 1996 Resolved
POST GARBARGE PLAN
Condition: Unknown
Due 10 July 1996
Resolved 10 July 1996
Documentation
Issued 15 May 1996 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 10 July 1996
Resolved 10 July 1996
Documentation
Issued 28 April 1993 Resolved
PROVIDE ON BOARD A VALID FCC RADIO STATION LICENSE AND PROVIDE COPY OF SAMEFOR AN ATTENDING USCG MARINE INSPECTOR NO LATER THAN 28MAY93. LICENSE IS TO BE POSTED ON THE VESSEL.
Condition: Unknown
Due 4 November 1993
Resolved 4 November 1993
Navigation
Issued 28 April 1993 Resolved
DEMONSTRATE PROPER OPERATION OF THE RADAR UNIT TO AN ATTENDING USCG MARINE INSPECTOR NO LATER THAN 28MAY93.
Condition: Unknown
Due 26 May 1993
Resolved 26 May 1993
Documentation
Issued 28 April 1993 Resolved
PROVIDE AND POST ON BOARD A STABILITY LETTER ISSUED BY USCG MARINE SAFETY CENTER NO LATER THAN 28MAY93. VESSEL IS RESTRICTED TO SIX (6) OR FEWER PASSENGERS UNTIL THE STABILITY LETTER HAS BEEN PROVIDED TO AN ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 4 November 1993
Resolved 4 November 1993
Documentation
Issued 28 April 1993 Resolved
POST AN EMERGENCY CHECK OFF LIST IN PASSENGER AREA.
Condition: Unknown
Due 26 May 1993
Resolved 26 May 1993

Casualty record · 1

21 July 2004Routine · role: Involved in a Marine Investigation (non-casualty) · activity 2247486
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.