WILD HEARTS is a 1992 passenger vessel (inspected). The Coast Guard has recorded 18 inspections since 2016, most recently in March 2026, along with 14 deficiencies and 1 casualty investigation in 2020.

Records from 2016 to 2026. Most recent: inspection, 11 March 2026.

Built
1992
Last inspected
11 March 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 11 March 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDL5081
386339
Flag
UNITED STATES
Maury page id
psix-386339

Documentation record

Registered dimensions (L × B × D)53.0 ft × 29.0 ft × 6.0 ft
Registered tonnagegross 15 / net 14
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGOLD COAST YACHTS INC · ST CROIX, VI, UNITED STATES · built 1992
Hull materialFRP (Fiberglass)
PropulsionAuxiliary Sail
Hull shapeSail (Faired Keel)
Hull configurationTwin Hull
Hailing portORANGE BEACH, AL
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 20 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it15 - Simplified, Gross Ton
14 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 18

11 March 2026 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8324775
4 December 2025 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8277434
13 January 2025 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8062822
13 December 2023 Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7838748
13 December 2023 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7838787
15 December 2022 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7609782
23 June 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7233942
20 October 2020 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7080751
5 October 2020 Administrative Inspection · COI Inspection · Hull Examination · Damage Survey · Deficiency Check · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7071822
9 March 2020 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6923885
15 October 2019 Deficiency Check · Hull Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6834752
8 February 2019 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6622431
2 February 2018 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6348710
4 January 2018 Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6332791
23 March 2017 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6110879
1 February 2017 Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6081303
21 January 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5801953
15 January 2016 Internal Structural Exam · Examination of Repairs · Administrative Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5812620

Deficiency record · 14

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 March 2026 Resolved
Each ring life buoy on a vessel must: (1) Be approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150. Vessels ring life buoy's grablines were wasted and brittle. 46 CFR 180.70
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 March 2026
Resolved 23 March 2026
Resolution: Owner purchased new life bouys.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 11 February 2025 Resolved
Vessels described by 46CFR175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Vessel did not have installed interconnected fire detection system. Install system.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 March 2025
Resolved 18 February 2025
Resolution: Objective evidence received of installed interconnected fire detection system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 February 2025 Resolved
Where flexible hose are permitted...two hose clamps must be used on each end of the hose. Fuel lines were witnessed with only single hose clamps. Add additional hose clamp to each missing location.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2025
Resolved 18 February 2025
Resolution: Received documentary evidence of installed hose clamps.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 February 2025 Resolved
Electrical equipment on a vessel must be installed and maintained protect passengers, crew, other persons, and the vessel from electrical hazards. Dead end wires were noted in electrical cabinet and on top of speaker boxes. Secure electrical connections in junction boxes or remove cabling.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2025
Resolved 18 February 2025
Resolution: Received documentary evidence of electrical wires secured.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 February 2025 Resolved
No Marine employer shall engage as crew member unless individual passes a chemical test for dangerous drugs for that employer. Master was not enrolled in DAPI. Show negative pre-employment drug test.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 11 February 2025
Resolved 18 February 2025
Resolution: Received documentary evidence of pre-employment testing and enrollment in the DAPI program.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 9 February 2024 Resolved
The design, construction, and stowage of portable tanks and related fuel lines must meet the requirements of ABYC H-25 which state a portable tank is defined as 07 gallons or less. Marine Inspector observed tanks over 07 gallons. Replace.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2024
Resolved 28 February 2024
Resolution: Vessel supplied picture of new fuel tanks. Marine Inspector reviewed and found satisfactory.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 9 February 2024 Resolved
All equipment capable of transmitting an automatic distress alert which includes position of the ship must have either an integral navigation receiver or capability of being connected to an external navigation receiver. Marine inspector observed no gps on radio or connection to the vessel's gps. Repair. 47CFR80.1086(c)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2024
Resolved 28 February 2024
Resolution: Vessel supplied picture of gps input on VHF. Marine Inspector reviewed and found satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 December 2021 Resolved
The number and identification of the items stowed inside must be marked in clearly legible letters. Emergency escape hatches must be labeled. Stickers have not yet been placed due to recent painting and repairs in drydock. Provide photos of placed stickers prior to operating with passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 December 2021
Resolution: Photos of proper stickers provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 April 2020 Resolved
Starboard life ring float light had non-approved battery type installed according the manufacturers instructions. Each float light must have an approved battery. Replace battery with type suitable to the float light manufacturer.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2020
Resolved 27 April 2020
Resolution: Installed new USCG approved float light compatible with RAYVAC 945 battery. Recieved pictures of installation IAW applicable CFRs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 April 2020 Resolved
Starboard life ring painter line not permanently attached to life ring. Each required life ring must have a 60 foot painter line attached in a manner to uphold breaking strength minimums. Attach painter line by splicing or other manufacturer recommended procedures.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2020
Resolved 27 April 2020
Resolution: Vessel O/O obtained a manufacturer approved line splice kit and successfully spliced the painter line around the body of the life ring.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 14 February 2017 Resolved
Provide proof of up to date EPIRB registration.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2017
Resolved 23 March 2017
Resolution: EPIRB registration provided.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 14 February 2017 Resolved
Replace EPIRB hydrostatic release with new.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2017
Resolved 23 March 2017
Resolution: New Hydrostatic release installed.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 14 February 2017 Resolved
Provide current charts and navigation publications.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2017
Resolved 23 March 2017
Resolution: Updated charts and pubs.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 14 February 2017 Resolved
Battery to float light expired. Replace with new.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2017
Resolved 23 March 2017
Resolution: New battery installed.

Casualty record · 1

20 October 2020Routine · role: Involved in a Marine Casualty · activity 7080751
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.