MAURY USCG vessel records Sign in
← All vessels

ENSERCH GARDEN BANKS

ENSERCH GARDEN BANKS is a mobile offshore drilling unit. The Coast Guard has recorded 5 inspections since 1995, most recently in May 2002, along with 22 deficiencies.

Records from 1995 to 2002. Most recent: inspection, 17 May 2002.

Built
Not recorded
Last inspected
17 May 2002
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

386380
Flag
PANAMA
—
Maury page id
psix-386380

Inspections, by type

…with no type recorded1
Years with a record 5 calendar years (1995–2002)
The 5 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 24 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records itNot recorded
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 5

17 May 2002 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1618106
13 August 1998 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1442731
14 August 1997 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1380965
29 August 1996 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1419655
5 September 1995 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1435674

Deficiency record · 22

Electrical
Issued 13 August 1998 Resolved
COMPLETE FABRICATION AND INSTALLATION OF ELECTRICAL DISTRIBUTION PANEL BREAKER COVERS THROUGHOUT AS NECESSARY.
Condition: Unknown
Due 11 September 1998
Resolved 11 September 1998
Construction/Loadline
Issued 13 August 1998 Resolved
GUAGE DECK PLATING IN COLUMN PC2 TO CHAIN LOCKERS 4 & 5 TO THE SATISFACTIONOF ATTENDING CLASS SURVEYOR. SUBMIT REPORT TO [name withheld].
Condition: Unknown
Due 13 August 1998
Resolved 13 August 1998
Lifesaving
Issued 13 August 1998 Resolved
REPLACE AFTER WIRE FALLS TO LIFEBOAT #4 AS ORIGINAL. CONDUCT 110% WEIGHT LOAD TEST TO THE SATISFACTION OF [name withheld].
Condition: Unknown
Due 13 August 1998
Resolved 13 August 1998
Lifesaving
Issued 13 August 1998 Resolved
CROP AND RENEW WINCH DECK GRATING SUPPORTS, WHERE WASTED, AT LIFEBOAT STATION #3.
Condition: Unknown
Due 11 September 1998
Resolved 11 September 1998
Electrical
Issued 13 August 1998 Resolved
RENEW FUEL OIL SUPPLY FLEX LINES ON ALL FOUR MAIN GENERATOR PRIME MOVERS.
Condition: Unknown
Due 11 September 1998
Resolved 11 September 1998
Lifesaving
Issued 13 August 1998 Resolved
CROP AND RENEW WASTED AND HOLED HAND RAILS THROUGHOUT RIG AS NECESSARY.
Condition: Unknown
Due 11 September 1998
Resolved 11 September 1998
Lifesaving
Issued 13 August 1998 Resolved
REPAIR, ADJUST OR REPLACE GENERAL ALARM BELLS THROUGHOUT AS NECESSARY.
Condition: Unknown
Due 11 September 1998
Resolved 11 September 1998
Lifesaving
Issued 13 August 1998 Resolved
CONDUCT 1.1 OPERATIONAL TEST OF LIFEBOAT RELEASE GEAR OR ALTERNATE TEST SUBJECT TO THE APPROVAL OF THE COGNIZANT OCMI.
Condition: Unknown
Due 31 December 1999
Resolved 17 August 1998
Lifesaving
Issued 13 August 1998 Resolved
CROP AND RENEW WASTED BRACKETS TO VERTICAL I-BEAM SUPPORTS IN DRILL WATER BOX BEAM DECK AREA, TO SATISFACTION OF COGNIZANT OCMI AND CLASS SURVEYOR.
Condition: Unknown
Due 13 August 1998
Resolved 13 August 1998
Lifesaving
Issued 13 August 1998 Resolved
CONDUCT AND PROPERLY LOG LIFEBOAT RELEASE GEAR INSPECTION.
Condition: Unknown
Due 11 September 1998
Resolved 11 September 1998
Lifesaving
Issued 14 August 1997 Resolved
INSTALL RETROREFLECTIVE MATERIAL ON ALL LIFESAVING EQUIPMENT.
Condition: Unknown
Due 14 August 1997
Resolved 14 August 1997
Fire Fighting
Issued 14 August 1997 Resolved
MAKE ALL PENETRATIONS AND DOORS IN GALLEY A-CLASS BULKHEADS STEEL OR EQUIVALENT METAL CONSTRUCTION AND CAPABLE OF LATCHING FROM EITHER SIDE.
Condition: Unknown
Due 14 August 1997
Resolved 14 August 1997
Fire Fighting
Issued 14 August 1997 Resolved
LABORATORY ANALYZE FIREFIGHTING FOAM.
Condition: Unknown
Due 14 August 1997
Resolved 14 August 1997
Electrical
Issued 14 August 1997 Resolved
OVERHAUL MAIN GENERATOR NO. 4. DEMONSTRATE ALL EMERGENCY SHUTDOWN TESTS TO THE SATISFACTION OF CLASSIFICATION SOCIETY.
Condition: Unknown
Due 14 August 1997
Resolved 14 August 1997
Fire Fighting
Issued 14 August 1997 Resolved
REPAIR NOZZLES ON HELIDECK FUEL TANK DELUGE SYSTEM.
Condition: Unknown
Due 14 August 1997
Resolved 14 August 1997
Lifesaving
Issued 14 August 1997 Resolved
PROPERLY EQUIP ALL LIFEBOATS IN ACCORDANCE WITH SOLAS, CHAPTER III.
Condition: Unknown
Due 14 August 1997
Resolved 14 August 1997
Documentation
Issued 5 September 1995 Resolved
PROVIDE COPY OF FULL TERM PANAMANIAN CODE CERTIFICATE TO [name withheld].
Condition: Unknown
Due 5 September 1995
Resolved 5 September 1995
Documentation
Issued 5 September 1995 Resolved
SUBMIT APPROVAL LETTER FOR SHIPBOARD OIL POLLUTION EMERGENCY PLAN (SOPEP) TO [name withheld].
Condition: Unknown
Due 3 October 1995
Resolved 3 October 1995
Electrical
Issued 5 September 1995 Resolved
COMPLETE FINAL INSTALLATION OF EXPLOSION PROOF EQUIPMENT AND CABLES IN ALL HAZARDOUS LOCATIONS AS IDENTIFIED BY ABS/USCG WORKLIST. DRILLING OPERATIONS MAY NOT COMMENCE UNTIL ALL HAZARDOUS LOCATIONS ARE INSPECTED BY AN ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Deck/Cargo
Issued 5 September 1995 Resolved
PERFORM ANNUAL INSPECTION ON MANITOWOC AND MONARCH CRANES.
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Documentation
Issued 5 September 1995 Resolved
PROVIDE ONBOARD THE FOLLOWING: OIL POLLUTION PLACARD, GARBAGE DISCHARGE PLACARD, GARBAGE DISCHARGE LOG.
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Documentation
Issued 5 September 1995 Resolved
SUBMIT FLAG STATE APPROVAL FOR THE FOLLOWING TO [name withheld]: FIRE AND SAFETY PLAN, HAZARDOUS LOCATION PLAN, CONSTRUCTION PORTFOLIO, OPERATIONS MANUAL.
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.