Records from 1995 to 2002. Most recent: inspection, 17 May 2002.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Electrical
Issued 13 August 1998
Resolved
COMPLETE FABRICATION AND INSTALLATION OF ELECTRICAL DISTRIBUTION PANEL BREAKER COVERS THROUGHOUT AS NECESSARY.
Condition: Unknown
Due 11 September 1998
Resolved 11 September 1998
Construction/Loadline
Issued 13 August 1998
Resolved
GUAGE DECK PLATING IN COLUMN PC2 TO CHAIN LOCKERS 4 & 5 TO THE SATISFACTIONOF ATTENDING CLASS SURVEYOR. SUBMIT REPORT TO [name withheld].
Condition: Unknown
Due 13 August 1998
Resolved 13 August 1998
Lifesaving
Issued 13 August 1998
Resolved
REPLACE AFTER WIRE FALLS TO LIFEBOAT #4 AS ORIGINAL. CONDUCT 110% WEIGHT LOAD TEST TO THE SATISFACTION OF [name withheld].
Condition: Unknown
Due 13 August 1998
Resolved 13 August 1998
Lifesaving
Issued 13 August 1998
Resolved
CROP AND RENEW WINCH DECK GRATING SUPPORTS, WHERE WASTED, AT LIFEBOAT STATION #3.
Condition: Unknown
Due 11 September 1998
Resolved 11 September 1998
Electrical
Issued 13 August 1998
Resolved
RENEW FUEL OIL SUPPLY FLEX LINES ON ALL FOUR MAIN GENERATOR PRIME MOVERS.
Condition: Unknown
Due 11 September 1998
Resolved 11 September 1998
Lifesaving
Issued 13 August 1998
Resolved
CROP AND RENEW WASTED AND HOLED HAND RAILS THROUGHOUT RIG AS NECESSARY.
Condition: Unknown
Due 11 September 1998
Resolved 11 September 1998
Lifesaving
Issued 13 August 1998
Resolved
REPAIR, ADJUST OR REPLACE GENERAL ALARM BELLS THROUGHOUT AS NECESSARY.
Condition: Unknown
Due 11 September 1998
Resolved 11 September 1998
Lifesaving
Issued 13 August 1998
Resolved
CONDUCT 1.1 OPERATIONAL TEST OF LIFEBOAT RELEASE GEAR OR ALTERNATE TEST SUBJECT TO THE APPROVAL OF THE COGNIZANT OCMI.
Condition: Unknown
Due 31 December 1999
Resolved 17 August 1998
Lifesaving
Issued 13 August 1998
Resolved
CROP AND RENEW WASTED BRACKETS TO VERTICAL I-BEAM SUPPORTS IN DRILL WATER BOX BEAM DECK AREA, TO SATISFACTION OF COGNIZANT OCMI AND CLASS SURVEYOR.
Condition: Unknown
Due 13 August 1998
Resolved 13 August 1998
Lifesaving
Issued 13 August 1998
Resolved
CONDUCT AND PROPERLY LOG LIFEBOAT RELEASE GEAR INSPECTION.
Condition: Unknown
Due 11 September 1998
Resolved 11 September 1998
Lifesaving
Issued 14 August 1997
Resolved
INSTALL RETROREFLECTIVE MATERIAL ON ALL LIFESAVING EQUIPMENT.
Condition: Unknown
Due 14 August 1997
Resolved 14 August 1997
Fire Fighting
Issued 14 August 1997
Resolved
MAKE ALL PENETRATIONS AND DOORS IN GALLEY A-CLASS BULKHEADS STEEL OR EQUIVALENT METAL CONSTRUCTION AND CAPABLE OF LATCHING FROM EITHER SIDE.
Condition: Unknown
Due 14 August 1997
Resolved 14 August 1997
Fire Fighting
Issued 14 August 1997
Resolved
LABORATORY ANALYZE FIREFIGHTING FOAM.
Condition: Unknown
Due 14 August 1997
Resolved 14 August 1997
Electrical
Issued 14 August 1997
Resolved
OVERHAUL MAIN GENERATOR NO. 4. DEMONSTRATE ALL EMERGENCY SHUTDOWN TESTS TO THE SATISFACTION OF CLASSIFICATION SOCIETY.
Condition: Unknown
Due 14 August 1997
Resolved 14 August 1997
Fire Fighting
Issued 14 August 1997
Resolved
REPAIR NOZZLES ON HELIDECK FUEL TANK DELUGE SYSTEM.
Condition: Unknown
Due 14 August 1997
Resolved 14 August 1997
Lifesaving
Issued 14 August 1997
Resolved
PROPERLY EQUIP ALL LIFEBOATS IN ACCORDANCE WITH SOLAS, CHAPTER III.
Condition: Unknown
Due 14 August 1997
Resolved 14 August 1997
Documentation
Issued 5 September 1995
Resolved
PROVIDE COPY OF FULL TERM PANAMANIAN CODE CERTIFICATE TO [name withheld].
Condition: Unknown
Due 5 September 1995
Resolved 5 September 1995
Documentation
Issued 5 September 1995
Resolved
SUBMIT APPROVAL LETTER FOR SHIPBOARD OIL POLLUTION EMERGENCY PLAN (SOPEP) TO [name withheld].
Condition: Unknown
Due 3 October 1995
Resolved 3 October 1995
Electrical
Issued 5 September 1995
Resolved
COMPLETE FINAL INSTALLATION OF EXPLOSION PROOF EQUIPMENT AND CABLES IN ALL HAZARDOUS LOCATIONS AS IDENTIFIED BY ABS/USCG WORKLIST. DRILLING OPERATIONS MAY NOT COMMENCE UNTIL ALL HAZARDOUS LOCATIONS ARE INSPECTED BY AN ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Deck/Cargo
Issued 5 September 1995
Resolved
PERFORM ANNUAL INSPECTION ON MANITOWOC AND MONARCH CRANES.
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Documentation
Issued 5 September 1995
Resolved
PROVIDE ONBOARD THE FOLLOWING: OIL POLLUTION PLACARD, GARBAGE DISCHARGE PLACARD, GARBAGE DISCHARGE LOG.
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Documentation
Issued 5 September 1995
Resolved
SUBMIT FLAG STATE APPROVAL FOR THE FOLLOWING TO [name withheld]: FIRE AND SAFETY PLAN, HAZARDOUS LOCATION PLAN, CONSTRUCTION PORTFOLIO, OPERATIONS MANUAL.
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995