Records in 2016. Most recent: inspection, 17 November 2016.
A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.
Lifesaving › Embarkation Appliances/Stations › Side Ropes
Issued 19 September 2016
Resolved
An embarkation ladder extending from the deck to the waterline shall be provided at each launching station. The starboard side embarkation ladder was found to be rotted/wasted at the deck connection point. 74SOLAS(97) III/11.7
Action required: 17 - Rectify deficiencies prior to departure
Due 21 September 2016
Resolved 21 September 2016
Resolution: Vessel replaced the embarkation ladder.
Operations/Management › Pollution › Control of Discharge of Oil
Issued 19 September 2016
Resolved
The Company should establish procedures, plans and instructions, including checklists as appropriate for key shipboard operations concerning the safety of the personnel, ship and protection of the environment. The maintenance on the OWS was found to be inline with the SMS and OWS instruction manual but the system was found to be totally contaminated. Request Audit from the Certifying Entity. ISM A
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 November 2016
Resolution: After a ISM audit, the SMS procedures have been updated.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 14 September 2016
Resolved
Oil filtering equipment shall be of a design to ensure that any oily mixture discharged to sea after passing through the system has an oil content not exceeding 15ppm. Overboard discharge piping on the OWS was found to have a dark effluent exceeding 15ppm. Must provide operational test prior to departure. MARPOL Annex I/17.4 17c
Action required: 17 - Rectify deficiencies prior to departure
Due 21 September 2016
Resolved 21 September 2016
Resolution: Vessel was able to perform a satisfactory OWS test.
Documentation › Logs/Records › Logbook (official)
Issued 14 September 2016
Resolved
Each operation shall be fully reloaded without delay in the oil record book part 1 so that all entries in the book appropriate to that operation are completed. The Chief Engineer was found to be rounding up the time and the quantities in the oil record book. request audit from certifying entity. MARPOL ANNEX I/ 17.4 40.A
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 November 2016
Resolution: After a ISM audit, the CE has been requested to record information precisely.
Engineering › Shafting/Propeller Arrangements › Propeller (controllable pitch)
Issued 4 March 2016
Resolved
1499:PSCO observed a rubber hose connecting the CPP box tell-tale drain to the CPP hydraulic tank. PSCO confirmed that this is not an original installation via ships drawings. In addition PSCO observed a steady stream of hydraulic oil from the tell- tale valve while the circulation pump was energized. SOLAS 2014 I/11(b) 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 March 2016
Resolution: Received class report stating that the tell-tale tube had been placed back to the CPP unit.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 4 March 2016
Resolved
1730: While testing the 15 ppm alarm on the oily water separator the OWS filter housing sprayed water from the upper housing flange. 74 SOLAS (2014) I/11(a) 50ac
Action required: 705 - Other - as specified
Due 3 April 2016
Resolved 8 March 2016
Resolution: Received a class report stating that the OWS gasket was renewed by the ship's crew and found to comply with RS rules.
Fire Fighting › Remote Fuel Shutoff › General
Issued 4 March 2016
Resolved
0750: Crew was unable to open the door covering the quick closing valve pull handle for the emergency generator. 74 SOLAS (2014) II-2/14.1.1 10c
Action required: 705 - Other - as specified
Resolved 4 March 2016
Resolution: Crew was able to open the door covering the quick closing valve pull handle for the emergency generator.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 4 March 2016
Resolved
2120: PSCO observed two occasions, one on 13FEB16 and one on 05FEB16 where garbage was sent to a reception facility and was not logged in the garbage record book. MARPOL ANNEX V/10.3.1 10c
Action required: 705 - Other - as specified
Resolved 4 March 2016
Operations/Management › Drills/Instruction › Not Conducted
Issued 4 March 2016
Resolved
3032: PSCO observed that the vessel exceeded more than two months since their last enclosed space drill and was conducting the enclosed space drill every three months. 74 SOLAS (2014) III/19.3.3 50ac
Action required: 705 - Other - as specified
Due 3 April 2016
Resolved 8 March 2016
Resolution: Received a class report stating that the vessel had conducted an enclosed space drill and was instructed to do so every two months.
Lifesaving › Lifeboat › Seating
Issued 4 March 2016
Resolved
0610: The port side lifeboat had a broken seat strap buckle near the entrance. 74 SOLAS (2014) III/20.2 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 March 2016
Resolution: Recieved a class report stataing that the strap had been replaced.
Lifesaving › Lifeboat › Hull
Issued 4 March 2016
Resolved
0610: Starboard side lifeboat had delamination damage on both sides of the aft keel near the propeller. 74 SOLAS III/5(a) 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 March 2016
Resolution: Received a class report stating that the crew had made permanent repairs to the areas of delamination found on the starboard life boat.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Discharge Hose/Tube
Issued 4 March 2016
Resolved
0720: Five portbale fire extinguishers installed throughout the ship had pinched discharge hoses, restricting the flow. 74 SOLAS (2014) II-2/14.1.1 10c
Action required: 705 - Other - as specified
Resolved 4 March 2016
Resolution: The vessel had more spares on board than required and crew replaced the faulty extinguishers.