MAURY USCG vessel records Sign in
← All vessels

MARGARITA

MARGARITA is a 1992 passenger vessel (inspected). The Coast Guard has recorded 72 inspections since 1993, most recently in April 2026, along with 166 deficiencies, 1 operational control and 4 casualty investigations between 2010 and 2011.

Records from 1993 to 2026. Most recent: inspection, 1 April 2026.

Built
1992
Last inspected
1 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDE6466
386411
Flag
UNITED STATES
368008000
Maury page id
psix-386411

Inspections, by type

…with no type recorded18
Years with a record 28 calendar years (1993–2026)
The 72 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)53.0 ft × 20.0 ft × 8.0 ft
Registered tonnagegross 22 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderFAT CAT CHARTERS INC DBA · PITI, GUAM · built 1992
Hull materialFRP (Fiberglass)
PropulsionDiesel
Hull shapeNot recorded
Hull configurationTwin Hull
Hailing portAGANA, GU
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 18 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it18 - Simplified, Net Ton
22 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDE6466MMSI 368008000 · active · compulsorily equipped · granted 20 July 2018, expires 15 October 2028
WCT6662MMSI not assigned · expired · compulsorily equipped · granted 27 July 1995, cancelled 7 January 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 72

1 April 2026 Deficiency Check · COI Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8332780
28 May 2025 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8141182
3 April 2025 Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8103705
20 February 2025 In-Service Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8081787
10 July 2024 Deficiency Check · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7954793
8 March 2023 Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7763638
10 February 2023 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7643647
15 June 2022 Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 7478949
29 March 2022 Deficiency Check · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7420447
3 May 2021 Deficiency Check · COI Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7188705
23 March 2021 Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7161692
30 March 2020 Administrative Inspection · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6931624
23 July 2019 Plan Review "T" Boat · Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6769180
2 July 2019 Deficiency Check · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6732997
16 April 2019 Examination of Repairs · Drydock Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6664136
25 February 2019 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6631450
18 June 2018 Annual Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6449913
26 June 2017 Annual Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6186821
3 April 2017 Examination of Repairs · Deficiency Check · Drydock Exam · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6123383
3 July 2016 Type not recorded
No type recorded · Station Apra Harbor · USCG Oceania District (CGD-O) · Activity 5931189
21 March 2016 COI Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5837109
13 June 2012 Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4342513
7 June 2012 Spot Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4336243
26 September 2011 Examination of Repairs · Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4154070
15 December 2010 Type not recorded
No type recorded · USCG Oceania District (dre) · USCG Oceania District (CGD-O) · Activity 3911506
23 November 2010 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3897915
23 November 2010 Type not recorded
No type recorded · Station Apra Harbor · USCG Oceania District (CGD-O) · Activity 3897985
12 October 2010 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3874912
19 January 2010 Damage Survey
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3665666
14 January 2010 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3860059
16 April 2009 Annual Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3453425
19 August 2008 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3302691
23 April 2008 Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3190073
7 January 2008 Hull Examination
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3125618
23 May 2007 Deficiency Check · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2938812
27 March 2007 Type not recorded
No type recorded · USCGC ASSATEAGUE (WPB 1337) · USCG Oceania District (CGD-O) · Activity 2910592
2 May 2006 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2638251
29 April 2006 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2638241
29 April 2006 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2686462
22 March 2006 COI Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2613201
9 December 2002 Damage Survey · Administrative Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1719208
8 December 2002 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1729882
8 August 2002 COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1657146
30 October 2001 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1075652
11 October 2001 Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1366582
7 August 2001 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1069847
29 August 2000 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 822458
8 August 2000 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1365904
9 March 2000 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1046906
13 January 2000 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1048010
29 November 1999 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 812019
7 September 1999 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 782002
12 August 1999 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 776735
2 August 1999 MARPOL Annex V Examination · Hull Examination · COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1361005
8 June 1999 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 806155
9 May 1999 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 796494
2 November 1998 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 803916
9 October 1998 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1364879
29 July 1998 Deficiency Check · MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1129674
5 May 1998 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 790629
14 January 1998 Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 776940
2 October 1997 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1120906
11 August 1997 Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1117428
27 July 1997 Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 784193
29 July 1996 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1090115
9 July 1996 COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1090774
22 May 1996 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1084864
5 January 1996 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 879914
15 November 1995 Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1186937
15 November 1995 Re-Inspection · Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1421048
6 September 1994 Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1173771
22 July 1993 COI Inspection · Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 843226

Deficiency record · 166

07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 1 April 2026 Resolved
The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. Port side fuel shutoff valve was found installed with locking valve handle, prohibiting the pull wire from actuating to valve to close position. 46 CFR 182.455(b)(4) - 17 c. Deficiency Cleared during inspection.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 April 2026
Resolved 1 April 2026
Resolution: Valve stopper was removed and remote means tested in presence of attending Marine Inspector during COI inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 1 April 2026 Resolved
Exhaust gas must not leak from the piping or any connections. The piping must be properly supported by noncombustible hangers or blocks. Identified smoking coming from exhaust connection, forward of the wet exhaust piping on port engine. 46 CFR 182.430(b) - 16 c.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2026
Resolved 18 May 2026
Resolution: O/O fitted new manifold spool peice, before the wet exhaust fitting, with new lip for clamp. Engine ran for approx 5min, no exhaust gas or smoking witnessed. Repair considered satisfactory.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 1 April 2026 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible. No current paper charts available onboard to supplement operator’s electronic chart. Provide up-to-date back-up paper chart for operating area. 46 CFR 184.420(a)(1) - 16 c.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2026
Resolved 18 May 2026
Resolution: New charts provided onboard. O/O instructed to keep charts up to date with BNTM.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 1 April 2026 Resolved
On a vessel of not more than 19.8 meters (65 feet) in length carrying more than 49 passengers, and on a vessel of more than 19.8 meters (65 feet) in length, the minimum capacity of the fire pump must be 189 liters (50 gallons) per minute at a pressure of not less than 414 kPa (60 psi) at the pump outlet. The pump outlet must be fitted with a pressure gauge. Fire pump outlet gauge found broken and inoperable. Replace and prove proper operation. 46 CFR 181.300(b) - 50 c.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2026
Resolved 18 May 2026
Resolution: New pressure gauge fitted to dishcarge side of fire pump. All sat.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 1 April 2026 Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: (1) Date of the drill and training; and (2) General description of the drill scenario and training topics. No evidence of drills onboard within the last 3 months. Vessel logged and credited drills this date. 46 CFR 185.520(f) - 10 c.
Action required: 10 - Deficiency Rectified
Resolved 1 April 2026
Resolution: Vessel logged and credited drills this date.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 1 April 2026 Resolved
The master of the vessel shall ensure that: (a) Each EPIRB, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative. No test records available onboard. Vessel logged and credited testing this date. 46 CFR 185.728(a) - 10 c.
Action required: 10 - Deficiency Rectified
Resolved 1 April 2026
Resolution: Vessel logged and credited testing this date.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 April 2026 Resolved
An adult life jacket must be provided for each person carried on board a vessel. 03 life jackets taken out of service during inspection due to deterioration. 46 CFR 180.71(a) - 10 c.
Action required: 10 - Deficiency Rectified
Resolved 1 April 2026
Resolution: Life jackets were replaced in kind during COI inspection and marked accordingly. No reduction in pax count.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 April 2026 Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Ring life buoys found with worn marking of vessel name. 46 CFR 185.604(b) - 10 c.
Action required: 10 - Deficiency Rectified
Resolved 1 April 2026
Resolution: Life buoys were marked with marker during the COI inspection.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 28 May 2025 Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. Current EPIRB on board not registered with NOAA for notification after activation. Vessel restricted to operations within 3NM. 46 CFR 180.64 / 705 c.
Action required: 705 - Other - as specified
Resolved 29 May 2025
Resolution: EPIRB registered with NOAA; expiry 28May27
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 May 2025 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. Audible and visual bilge alarms for stbd hull fwd and aft, sound simultaneously, preventing Master at wheelhouse from identifying the specific flooding location. Audible chime not of sufficient volume. 46 CFR 182.530 / 16 c.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 11 June 2025
Resolution: O/O replaced chime, alarms tested satisfactory in presence of MI. All sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 May 2025 Resolved
For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Port hull engine room pre-engineered system not serviced since May 2023. 46 CFR 176.810(b)(2) / 10 c.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 May 2025
Resolved 28 May 2025
Resolution: Corrected on the spot. O/O replaced system in-kind spare with 8lbs., 150 cubic foot system, serviced Apr2025. Tested system, all sat.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 20 February 2025 Resolved
Each portable fire extinguisher on a vessel must be of an approved type. The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant Officer in Charge, Marine Inspection. 03 portable fire extinguishers were found unserviceable onboard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 February 2025
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 July 2024 Resolved
Each vessel must be equipped with at least two operable portable battery lights. Demonstrate to CG two operating portable lights.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2024
Resolved 24 July 2024
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 July 2024 Resolved
Audible alarm must be provided at the operating station to indicate a high water level in each bilge well. Repair inoperable alarm for STBD mid-void/space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2024
Resolved 24 July 2024
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 10 July 2024 Resolved
VSl must mark load line IAW stability letter.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2024
Resolved 24 July 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 July 2024 Resolved
Each ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Re-stencil fade VSL name on ring life buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2024
Resolved 24 July 2024
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 10 July 2024 Resolved
Fire and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: (1) Date of the drill and training; and (2) General description of the drill scenario and training. Provide proof of drills and training conducted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2024
Resolved 24 July 2024
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 8 March 2023 Resolved
Maximum number of passengers allowed on an FWD deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entranceway to that deck. Re-stencil numbers that have been paint over.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2023
Resolved 19 August 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 March 2023 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Mark lifejackets storage location.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2023
Resolved 19 August 2023
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 8 March 2023 Resolved
Portable watertight containers for distress flares and smoke signals shall be of a bright color, and containers shall be clearly marked in legible contrasting letters at least 12.7 millimeters (0.5 inches) high: “DISTRESS SIGNALS”. Provide proper container for flares.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2023
Resolved 19 August 2023
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 March 2023 Resolved
COI and Stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, in a conspicuous place on the vessel where observation by passengers is likely. If posting is impracticable, such as in an open boat, the certificates must be kept on board in a weathertight container readily available for use by the crew and display to passengers and others on request.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2023
Resolved 19 August 2023
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 8 March 2023 Resolved
Instruction and warning placard foe sewage overboard discharge valve is closed and secured must be post. Post missing warning & instructions.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2023
Resolved 19 August 2023
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 8 March 2023 Resolved
Each EPIRB must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative. Provide proof of monthly testing recorded in logbook.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2023
Resolved 19 August 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 March 2023 Resolved
Gauges to indicate jacket water discharge temperature must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station. Repair inoperable engine temperature gauge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2023
Resolved 19 August 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 March 2023 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Post missing donning instructions.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2023
Resolved 19 August 2023
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 8 March 2023 Resolved
Fire fighting/man Overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: (1) Date of the drill and training; and (2) General description of the drill scenario and training topics. Show proof of completed drills.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2023
Resolved 19 August 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 March 2023 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. Re-stencil mark for shut off valve.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2023
Resolved 19 August 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 March 2023 Resolved
A vessel of more than 7.9 meters (26 feet) in length, but not more than 19.8 meters (65 feet), must carry a minimum of one life buoy of not less than 610 millimeters (24 inches) in diameter. Provide life buoy with crab line that is in serviceable condition.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2023
Resolved 19 August 2023
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 March 2023 Resolved
The condition of the insulation for wire and cable must not be unimpaired. Make a proper water proof wire connections/splice for all electric submerge pumps and level alarm detector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2023
Resolved 19 August 2023
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 March 2023 Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. Provide two portable battery lights.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2023
Resolved 19 August 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 March 2023 Resolved
A) Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J–1942. B) Flexible nonmetallic hose may be used in non-vital water and pneumatic systems, subject to the limitations of paragraph (d)(1) through (d)(4) of this section. Unreinforced hoses are limited to a maximum service pressure of 349 kPa (50 psig), reinforced hoses are limited to a maximum service pressure of 1,034 kPa (150 psig). Provide proof that the hose on bilge piping meets SAE J–1942.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2023
Resolved 19 August 2023
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 March 2023 Resolved
Cooking equipment must be suitable for marine use. Equipment designed and installed in accordance with National Fire Protection Association (NFPA) 302, “Pleasure and Commercial Motor Craft,” complies with this requirement. Remove installed MAGMA Gas Grill from vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2023
Resolved 19 August 2023
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 March 2023 Resolved
New electrical installation must be approve by CG. Submit elementary one-line diagram of the solar power system to the cognizant OCMI for approval. Remove panel and storage battery with multiple wires/alligator clips below operating station from vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2023
Resolved 19 August 2023
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 8 March 2023 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Post emergency instruction.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2023
Resolved 19 August 2023
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 8 March 2023 Resolved
Vessel must carry adequate and up-to-date for voyage intended: (1) Charts of large enough scale to make safe navigation possible; (2) U.S. Coast Pilot or similar publication; (3) Coast Guard Light List; (4) Tide tables; and (5) Current tables, or a river current publication issued by the U.S. Army Corps of Engineers or a river authority.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2023
Resolved 19 August 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 March 2023 Resolved
Piping, including valves, pipe fittings and flanges, conveying vapor, gas, or liquid, the temperature of which exceeds 65.5 °C (150 °F), must be suitably insulated where necessary to prevent injuries. Install insulation on fire pump exhaust pipe.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2023
Resolved 19 August 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 March 2022 Resolved
On a vessel at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. The port engine room high level audible alarm is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 March 2022 Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a) The vessel’s fixed bilge pumps dewatering system is inoperable. Vessel is restricted to carrying no more than 49 passengers.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 May 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 March 2022 Resolved
Valves for removing water or impurities from diesel fuel in water traps or strainers are permitted. These valves must be provided with caps or plugs to prevent fuel spillage. The starboard diesel engine’s racor fuel filter drain valves is missing a plug.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2022
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 29 March 2022 Resolved
Each battery used in an item of lifesaving equipment, except inflatable survival craft equipment, must be replaced during the annual inspection if the expiration date of the battery has passed. The waterlight battery is expired. Vessel is restricted to daylight operations.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 March 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo ports and other similar openings
Issued 29 March 2022 Resolved
Each watertight bulkhead must be of sufficient strength to be capable of remaining watertight to the top of the bulkhead. Fill all holes in the port and starboard hull sections that divide the forward, mid and aft portions of the hull.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 April 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 March 2022 Resolved
Each floating waterlight must have a lanyard of at least 3 feet in length and no more than 6 feet, securing the waterlight around the body of the ring life buoy. The waterlight lanyard was less than 3 feet long.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 March 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 29 March 2022 Resolved
Deck rails must be designed and constructed to withstand a point load of 200 pounds applied an any point in any direction. The upper deck forward railing has a cracked weld.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 May 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 29 March 2022 Resolved
Provide proof of current enrollment for chemical drug testing for crew.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 March 2022
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 29 March 2022 Resolved
Provide proof of Marine Radio Operator permit for vessel master.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 April 2022
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 29 March 2022 Resolved
Provide current copies of light list and coast pilot as required.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 April 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 5 May 2021 Resolved
Stbd main engine cooling water temperature gauge inop
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 May 2021
Resolved 7 May 2021
Resolution: Replaced new temperature sensor on stbd main engine.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 3 May 2021 Resolved
Distress flares were expired.
Action required: 10 - Deficiency Rectified
Due 5 May 2021
Resolved 6 May 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 May 2021 Resolved
Ring bouy missing marking of vessel name.
Action required: 10 - Deficiency Rectified
Due 5 May 2021
Resolved 5 May 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 May 2021 Resolved
Stbd forward and port mid compartment high water alarm inop
Action required: 10 - Deficiency Rectified
Due 5 May 2021
Resolved 5 May 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 May 2021 Resolved
Port PTO bilge pump inop
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2021
Resolved 5 May 2021
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 3 July 2019 Resolved
46 CFR 181.420: Prove proper operation of pre-engineered firefighting suppression system for port and starboard engine room compartments to the satisfaction of the attending Marine Inspector. Alarm panels with light must be installed for each separated protected space in accordance with the manufacturer's manual.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2019
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 3 July 2019 Resolved
46 CFR 176.810(b)(2): Vessel's pre-engineered firefighting suppression system must be inspected annually by a competent person. Last annual inspection completed in June 2018.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 July 2019 Resolved
46 CFR 182.25-1: Prove proper operation of vessel's fixed bilge system to the satisfaction of the attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2019
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 3 July 2019 Resolved
46 CFR 180.64: Replace expired hydrostatic release (2/2019) for EPIRB with new.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 July 2019 Resolved
46 CFR 180.78 (a) (5): Separate adult and children life jackets; must be maintained in serviceable condition and stored in a clean and dry location.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 3 July 2019 Resolved
46 CFR 185.516 (a): Post missing donning placard for life jackets.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 July 2019 Resolved
46 CFR 185.604 (b): Replace faded reflective tape and mark vessel's name in 2" letters on additional child life jackets.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 July 2019 Resolved
46 CFR 176.25-50: Replace missing heat shield/lagging on port and starboard main engine dry exhaust.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 July 2019 Resolved
46 CFR 182.20-40(b(3): Handle on starboard fuel shut off does not close all the way due to fuel hose preventing the handle from turning.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2019
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 3 July 2019 Resolved
46 CFR 177.405 (a): Seal port side bulkhead between engine room compartment and forward hull to prevent passage of smoke and agent from escaping into forward void.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2019
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 3 July 2019 Resolved
46 CFR 176.25-50, 46 CFR 176.20-1, 46 CFR 182.20-45 (d): Port and starboard ventilation pipe for engine room ventilation with battery cables that passes through a cut out opening. Re-route battery cables and repair engine room ventilation pipe to prevent fire fighting agent from escaping from protected space. Submit repair proposal for re-routing battery cables to USCG for review prior to repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 July 2019 Resolved
46 CFR 183.340 (b)(4): Wire hangers with missing chaffing guard in port side hull to be replaced with new.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 July 2019 Resolved
46 CFR 181.520: Replace missing placards for portable fire extinguishers.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 July 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 July 2019 Resolved
46 CFR 183.350 (b): Properly secure battery boxes to prevent from shifting.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 July 2019
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 July 2019 Resolved
46 CFR 183.420: Repair anchor light and prove proper operation. Remove electrical tapes on running lights and prove proper operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 July 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 July 2019 Resolved
46 CFR 184.710: Multiple first aid kits with expired aspirins. Crew to inventory first aid kits and ensure contents per 46 CFR 160.041, and consolidated contents in one watertight container labeled First Aid Kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 July 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 July 2019 Resolved
46 CFR 177.406(f)Replace plastic trash receptacle with a non-combustible trash receptacle.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 July 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 July 2019 Resolved
46 CFR 176.20-1: Wooden board for port side fuel tank with wood rot and must be replaced with new.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 July 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 May 2019 Resolved
46 CFR 177.05-1, 46 CFR 183 (New T): Vessel owner/operator to submit an electrical plan to the OCMI for review and approval. A copy of TBoat New Construction Certification Package, provided for reference/ guide for completing an electrical plan.
Action required: 705 - Other - as specified
Due 29 June 2019
Resolved 19 August 2023
Resolution: Visual inspection of DC electrical system completed satisfactory. Special note added for vsl rep. to provide an updated and final electrical plan at next dry dock.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 May 2019 Resolved
46 CFR 177.05-1: Vsl owner/opertor to submit a bilge systems plan to the OCMI for review and approval. Provided copy of TBoat New Construction Certification Package, for further reference/guide for completing a bilge systems plan that shows individual bilge lines and bilge suctions for each watertight compartment.
Action required: 705 - Other - as specified
Due 29 June 2019
Resolved 23 July 2019
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 June 2018 Resolved
Both ME space fire-boys had safety pins inserted which would prevent the manual pull from working. Remove safety pins from fire-boy manual boy.
Action required: 10 - Deficiency Rectified
Due 19 June 2018
Resolved 19 June 2018
Resolution: Pins were removed.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 18 June 2018 Resolved
Newly hired crew were not familiar with how to recover a MOB or fight a fire. Conduct adequate emergency training with crew and demonstrate to USCG MI.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 19 June 2018
Resolved 19 June 2018
Resolution: Training was conducted by vessel master and drills were conducted sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 June 2018 Resolved
Ring buoy light could not be easily attached to ring buoy. Provide adequate detachable clip for ring buoy light.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 19 June 2018
Resolved 19 June 2018
Resolution: Ring buoy light was fitted with detachable clip.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 June 2018 Resolved
Stbd ME throttle had a bungee cord attached to aid throttle changes. Remove bungee cord from stbd ME and prove proper operation of ME.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 June 2018
Resolved 19 June 2018
Resolution: Bungee cord was removed and engine throttle was tested sat.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 18 June 2018 Resolved
Stbd aft HWA light was inop. Prove proper operation of stbd aft HWA light.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 19 June 2018
Resolved 19 June 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 June 2018 Resolved
Electric bilge pump in port engine space was not attached to the hull. Secure base of port engine space electric bilge pump to the hull.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 19 June 2018
Resolved 19 June 2018
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 18 June 2018 Resolved
HWA alarm and auto bilge indicator lights were not labeled. Properly label all HWA and bilge indicator lights.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 19 June 2018
Resolved 19 June 2018
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 18 June 2018 Resolved
The fire pump would not remotely start from operating station. Prove proper operation of remote start of fire pump.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 June 2018
Resolved 19 June 2018
Resolution: Pump throttle was adjusted to allow for remote start.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 June 2018 Resolved
Fuel system emergency shutoffs locations were not labeled. Properly label emergency fuel shutoffs locations.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 19 June 2018
Resolved 19 June 2018
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 18 June 2018 Resolved
Marine charts were not new or corrected. Provide new or properly corrected charts.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 June 2018
Resolved 19 June 2018
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 18 June 2018 Resolved
US Coast Pilot, CG light list and tide tables were old. Provide up to date US Coast Pilot, CG light list and tide tables were old.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 June 2018
Resolved 19 June 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 June 2018 Resolved
Port fuel tank was not properly grounded. Properly ground port fuel tank.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 19 June 2018
Resolved 19 June 2018
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 18 June 2018 Resolved
Magnetic compass light was inop. Repair magnetic compass light and prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2018
Resolved 27 June 2018
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 18 June 2018 Resolved
FCC Safety Cert was expired. Provide new FCC Safety Cert.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2018
Resolved 26 June 2018
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 18 June 2018 Resolved
Vessel waste management plan was missing. Provide vessel specific waste management plan.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2018
Resolved 27 June 2018
Navigation › Piloting/Steering › Coast Guard Light List
Issued 26 June 2017 Resolved
Provide 2017 USCG Light Light
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2017
Resolved 10 July 2017
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 26 June 2017 Resolved
Stencil vessel name on ring buoy
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2017
Resolved 10 July 2017
Fire Fighting › Fire Pumps › Power Source
Issued 3 April 2017 Resolved
No proof or documentation of approval from OCMI for gas fire pump. Vessel was previously outfitted with a diesel driven fire pump approved by USCG; vessel carries more than 49 passengers. Vessel must maintain approved equipment by USCG unless proof of alternative by OCMI can be provided.
Action required: 705 - Other - as specified
Due 3 April 2017
Resolved 8 May 2017
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 21 March 2016 Resolved
Provide log for emergency drills and EPIRB testing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 May 2016
Resolved 20 April 2016
Resolution: Provided log for emergency drills and EPIRB testing.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 21 March 2016 Resolved
Adujust bilge pump actuator linkage and demonstrate proper operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 May 2016
Resolved 20 April 2016
Resolution: Adujusted bilge pump actuator linkage and demonstrate proper operation.
Engineering › Bilge Water Management System › Interface Detector
Issued 21 March 2016 Resolved
Provide high water alarm for the fwd compartment stbd side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 May 2016
Resolved 20 April 2016
Resolution: Provided high water alarm for the fwd compartment stbd side.
Communications › Alarms/Indicators › High Water Alarm
Issued 7 June 2012 Resolved
Make repairs and prove proper operation of port fwd and aft stbd bilge high water alarms.
Action required: 705 - Other - as specified
Due 14 June 2012
Resolved 13 June 2012
Resolution: Alarms tested satisfactory.
Accommodation/Occupational Safety › Cooking Systems › Cooking Fuel
Issued 12 October 2010 Resolved
Stop use/remove BBQ grill (charcoal).
Due 12 October 2010
Resolved 12 October 2010
Engineering › Fuel Oil Service System › Tank
Issued 16 April 2009 Resolved
Install fuel tank bonding strap.
Due 3 May 2009
Resolved 6 July 2009
Documentation › Certificates/Documents › FCC SSL
Issued 16 April 2009 Resolved
Provide a current FCC station license.
Due 3 May 2009
Resolved 6 July 2009
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 April 2009 Resolved
Provide Asprin for first aid kit.
Due 3 May 2009
Resolved 16 April 2009
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 16 April 2009 Resolved
Provide missing nut for swim ladder bolts.
Due 3 May 2009
Resolved 6 July 2009
Deck/Cargo › Holds/Tanks › Hatch
Issued 16 April 2009 Resolved
Repairs both watertight hatch in main cabin. Prior to carry more than 49 pax.
Due 3 May 2009
Resolved 16 April 2009
Resolution: Completed satisfactory repair on both hatch. Vsl is permitted to carry 80 passengers as per COI.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 16 April 2009 Resolved
Cap unused through fitting.
Due 3 May 2009
Resolved 6 July 2009
Communications › Radio Communications › VHF Radiotelephone
Issued 16 April 2009 Resolved
Provide a valid FCC Safety Certificate.
Due 3 May 2009
Resolved 6 July 2009
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 23 April 2008 Resolved
Install forward navigation running light, as per Nav Rules.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 May 2008
Resolved 7 May 2008
Resolution: Completed satisfactory install of nav light.
Communications › Radio Communications › EPIRB
Issued 23 April 2008 Resolved
Register EPIRB, current registration is expired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 May 2008
Resolved 7 May 2008
Resolution: Registered EPIRD to expired 2010.
Documentation › Certificates/Documents › FCC SSL
Issued 24 May 2007 Resolved
Provide a valid FCC station license.
Due 7 August 2007
Resolved 7 August 2007
Documentation › Certificates/Documents › FCC SSL
Issued 24 May 2007 Resolved
Provide a valid FCC safety certificate.
Due 7 August 2007
Resolved 7 August 2007
Operations/Management › Equipment Service/Testing › EPIRB
Issued 24 May 2007 Resolved
Provide proof of expiration date for hydrostatic release.
Due 7 June 2007
Resolved 6 June 2007
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 24 May 2007 Resolved
Provide upper deck pax limit marking.
Due 7 June 2007
Resolved 7 June 2007
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 24 May 2007 Resolved
Repair fixed fire fighting system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Construction/Loadline
Issued 11 October 2001 Resolved
Install bilge pump"operating" indicator lights for port and stbd bilge pumps at the control station IAW 46 CFR 182.520.
Condition: Unknown
Due 11 November 2001
Resolved 29 October 2001
Construction/Loadline
Issued 11 October 2001 Resolved
Install seperate visual bilge alarm high water indicators at the operating station for each hull IAW 46 CFR 182.530.
Condition: Unknown
Due 11 November 2001
Resolved 29 October 2001
Lifesaving
Issued 11 October 2001 Resolved
Renew retroflective material on 10 PFD's.
Condition: Unknown
Due 11 November 2001
Resolved 29 October 2001
Lifesaving
Issued 8 August 2000 Resolved
Replace grab and throw lines on steering station ring buoy.
Condition: Unknown
Due 8 August 2000
Resolved 8 August 2000
Fire Fighting
Issued 8 August 2000 Resolved
Provide proof of portable fire extinguisher servicing.
Condition: Unknown
Due 8 August 2000
Resolved 8 August 2000
Construction/Loadline
Issued 8 August 2000 Resolved
Install a deck drain, sealing properly around drain, to allow proper drainage of main deck.
Condition: Unknown
Due 8 August 2000
Resolved 8 August 2000
Engineering
Issued 8 August 2000 Resolved
Properly align both outboard motors. Both motors must turn equally to_x001C_ allow safe navigation of the vessel.
Condition: Unknown
Due 8 August 2000
Resolved 8 August 2000
Electrical
Issued 8 August 2000 Resolved
Re-locate battery disconnect switch to a location as close as possible to the batteries.
Condition: Unknown
Due 8 August 2000
Resolved 8 August 2000
Construction/Loadline
Issued 13 January 2000 Resolved
Repair damage to forward bow area caused by vessel mooring procedures. Prior to initiating repairs the operator must obtain Coast Guard approval for the repair procedure. All repairs must be completed by 29FEB00.
Condition: Unknown
Due 13 January 2000
Resolved 13 January 2000
Construction/Loadline
Issued 29 November 1999 Resolved
Write up and present to Marine Inspection Office a repair proposal for bow repairs to the EX-TASI II. Upon approval of repair plan, conduct subject repairs no later than 10JAN00.
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Documentation
Issued 12 August 1999 Resolved
Vessel shall not operate until such time the vessel has a valid Certificateof Documentation onboard.
Condition: Unknown
Due 12 August 1999
Resolved 12 August 1999
Lifesaving
Issued 2 August 1999 Resolved
Install safety rails at embarkation areas.
Condition: Unknown
Due 2 August 1999
Resolved 2 August 1999
Lifesaving
Issued 2 August 1999 Resolved
Properly label first aid and flare kit.
Condition: Unknown
Due 9 August 1999
Resolved 2 August 1999
Navigation
Issued 2 August 1999 Resolved
Place on board navigation chart for area of operation and inland_x001C_ navigation rule book.
Condition: Unknown
Due 2 August 1999
Resolved 2 August 1999
Lifesaving
Issued 2 August 1999 Resolved
Place on board a complete first aid kit.
Condition: Unknown
Due 2 August 1999
Resolved 2 August 1999
Construction/Loadline
Issued 2 August 1999 Resolved
Properly mount engine gauges and bilge high level alarms.
Condition: Unknown
Due 9 August 1999
Resolved 8 August 1999
Navigation
Issued 2 August 1999 Resolved
Prove proper operation of navigation lights.
Condition: Unknown
Due 9 August 1999
Resolved 2 August 1999
Construction/Loadline
Issued 2 August 1999 Resolved
Double hose clamp all bilge discharge hoses.
Condition: Unknown
Due 9 August 1999
Resolved 8 August 1999
Lifesaving
Issued 2 August 1999 Resolved
Properly demonstrate fire and man-overboard drills to satisfaction of attending U.S. Coast Guard marine Inspector.
Condition: Unknown
Due 9 August 1999
Resolved 8 August 1999
Construction/Loadline
Issued 9 May 1999 Resolved
Provide proof of installation of bilge hi-level alarm & indicators meeting 46 CFR 182.530 for each space with a through hull fitting, machinery space,or space with a non-watertight hatch. Vessel COI will be revoked & vessel limited to nmt 6 passengers without proof of installation by 10JUN99.
Condition: Unknown
Due 9 May 1999
Resolved 9 May 1999
Construction/Loadline
Issued 9 October 1998 Resolved
PROVE PROPER OPERATION OF BILGE PUMP LOCATED IN PORT AMA (FORWARD).
Condition: Unknown
Due 9 October 1998
Resolved 9 October 1998
Construction/Loadline
Issued 29 July 1998 Resolved
PROVIDE ADEQUATE LENGTH OF SUCTION AND DISCHARGE HOSE AND STRAINER FOR PORTABLE BILGE PUMP
Condition: Unknown
Due 29 July 1998
Resolved 29 July 1998
Construction/Loadline
Issued 29 July 1998 Resolved
PROVIDE SUITABLE MARINE GRADE HOSES FOR DISCHARGE AND DOUBLE CLAMP ALL DISCHARGE HOSES FOR ALL BILGE PUMPS.
Condition: Unknown
Due 29 July 1998
Resolved 29 July 1998
Fire Fighting
Issued 29 July 1998 Resolved
PROVIDE DOCUMENTATION OF/FOR SERVICE OF ALL FIRE EXTINGUISHERS
Condition: Unknown
Due 29 July 1998
Resolved 29 July 1998
Fire Fighting
Issued 29 July 1998 Resolved
PROPERLY SECURE CONTROL STATION FIRE EXTINGUISHER
Condition: Unknown
Due 29 July 1998
Resolved 29 July 1998
Fire Fighting
Issued 29 July 1998 Resolved
PROPERLY LABLE LOCATION OF FIRE STATION (HYDRANT)
Condition: Unknown
Due 29 July 1998
Resolved 29 July 1998
Fire Fighting
Issued 29 July 1998 Resolved
REPLACE EXISTING DISCHARGE HOSE FOR FIRE PUMP WITH A SUITABLE MARINE GRADE HOSE AND DOUBLE CLAMP ALL CONNECTIONS
Condition: Unknown
Due 29 July 1998
Resolved 29 July 1998
Construction/Loadline
Issued 29 July 1998 Resolved
RELOCATE CONTROL SWITCHES FOR ALL BILGE PUMPS TO A CENTRAL LOCATION
Condition: Unknown
Due 29 July 1998
Resolved 29 July 1998
Electrical
Issued 29 July 1998 Resolved
INSTALL EMERGENCY CUT-OUT SWITCH FOR EACH STARTING BATTERY
Condition: Unknown
Due 29 July 1998
Resolved 29 July 1998
Electrical
Issued 29 July 1998 Resolved
PROPERLY SECURE ALL STARTING BATTERIES FROM SHIFTING
Condition: Unknown
Due 29 July 1998
Resolved 29 July 1998
Construction/Loadline
Issued 29 July 1998 Resolved
PROVIDE ELECTRICAL OVERLOAD PROTECTION FOR ALL BILGE PUMPS.
Condition: Unknown
Due 29 July 1998
Resolved 29 July 1998
Construction/Loadline
Issued 29 July 1998 Resolved
INSTALL A POSITIVE SHUT-OFF VALVE AT ALL BILGE DISCHARGE THRU-HULL FITTINGS
Condition: Unknown
Due 29 July 1998
Resolved 29 July 1998
Navigation
Issued 29 July 1998 Resolved
PROVE PROPER OPERATION OF STEERING SYSTEM TO INCLUDE SIMULTANEOUS OPERATIONOF BOTH OUTBOARD MOTORS
Condition: Unknown
Due 29 July 1998
Resolved 29 July 1998
Lifesaving
Issued 29 July 1998 Resolved
STENCIL AND APPLY REFLECTIVE TAPE TO ALL RING BUOYS
Condition: Unknown
Due 29 July 1998
Resolved 29 July 1998
Electrical
Issued 29 July 1998 Resolved
REPLACE GLOBE FOR OR REMOVE OVERHEAD LIGHTS ON MAIN DECK
Condition: Unknown
Due 29 July 1998
Resolved 29 July 1998
Electrical
Issued 29 July 1998 Resolved
RE-LABLE CIRCUIT DIRECTORY ON MAIN POWER PANEL LOCATED AT CONTROL STATION
Condition: Unknown
Due 29 July 1998
Resolved 29 July 1998
Accommodation/Occupational Safety
Issued 29 July 1998 Resolved
STENCIL MAX PASSENGER CAPACITY FOR UPPER DECK
Condition: Unknown
Due 29 July 1998
Resolved 29 July 1998
Lifesaving
Issued 29 July 1998 Resolved
CONDUCT A MAN OVERBOARD AND FIRE DRILL TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR
Condition: Unknown
Due 29 July 1998
Resolved 29 July 1998
Construction/Loadline
Issued 14 January 1998 Resolved
Resecure overhead support frames located below bow deck to bow deck proper.
Condition: Unknown
Due 14 January 1998
Resolved 14 January 1998
Fire Fighting
Issued 27 July 1997 Resolved
The discharge pressure from the installed fire pump is insufficient for fire fighting. Prove sufficient discharge pressure of the pump to the satisfaction of the local OCMI.
Condition: Unknown
Due 27 July 1997
Resolved 27 July 1997
Navigation
Issued 27 July 1997 Resolved
Prove the proper operation of the compass light.
Condition: Unknown
Due 27 July 1997
Resolved 27 July 1997
Unknown
Issued 27 July 1997 Resolved
Post a completed Emergency Broadcast Instruction Check-off sheet near the VHF radio.
Condition: Unknown
Due 27 July 1997
Resolved 27 July 1997
Lifesaving
Issued 27 July 1997 Resolved
Obtain and post a life jacket donning placard in a conspicuous location aboard the vessel that is regularly accessible and visible to the crew and passengers.
Condition: Unknown
Due 27 July 1997
Resolved 27 July 1997
Lifesaving
Issued 27 July 1997 Resolved
Replace or renew the grab lines on the Pilot house life ring bouy to the satisfaction of the local OCMI.
Condition: Unknown
Due 27 July 1997
Resolved 27 July 1997
Construction/Loadline
Issued 27 July 1997 Resolved
Hook up electrical power to the bilge pumps in both hulls and prove the proper operation of each to the satisfaction of the local OCMI.
Condition: Unknown
Due 27 July 1997
Resolved 27 July 1997
Fire Fighting
Issued 27 July 1997 Resolved
Obtain and install a nozzle on the onboard fire fighting hose.
Condition: Unknown
Due 27 July 1997
Resolved 27 July 1997
Accommodation/Occupational Safety
Issued 9 July 1996 Resolved
Strengthen fastening points of bow rails at rail to house mount.
Condition: Unknown
Due 9 July 1996
Resolved 9 July 1996
Fire Fighting
Issued 9 July 1996 Resolved
Replace existing B-I portable fire extinguisher with B-II extinguisher on main deck, stern.
Condition: Unknown
Due 9 July 1996
Resolved 9 July 1996
Accommodation/Occupational Safety
Issued 9 July 1996 Resolved
Mark maximum persons allowed (45) in way of ladders to upper deck.
Condition: Unknown
Due 9 July 1996
Resolved 9 July 1996
Navigation
Issued 15 November 1995 Resolved
Install compass, calibrate.
Condition: Unknown
Due 15 November 1995
Resolved 15 November 1995
Navigation
Issued 15 November 1995 Resolved
Troubleshoot inoperative stbd and stern running lights.
Condition: Unknown
Due 15 November 1995
Resolved 15 November 1995
Documentation
Issued 15 November 1995 Resolved
Obtain FCC Radio Telephone Certificate and inspection.
Condition: Unknown
Due 15 November 1995
Resolved 15 November 1995
Accommodation/Occupational Safety
Issued 15 November 1995 Resolved
Lable quantity and type (adult/child) of life jackets in storage location.
Condition: Unknown
Due 15 November 1995
Resolved 15 November 1995
Accommodation/Occupational Safety
Issued 15 November 1995 Resolved
Post garbage pollution placard.
Condition: Unknown
Due 15 November 1995
Resolved 15 November 1995
Accommodation/Occupational Safety
Issued 15 November 1995 Resolved
Repair all cracked bench seating.
Condition: Unknown
Due 15 November 1995
Resolved 15 November 1995
Accommodation/Occupational Safety
Issued 15 November 1995 Resolved
Tighten all loose steps on ladders.
Condition: Unknown
Due 27 November 1995
Resolved 27 November 1995
Navigation
Issued 15 November 1995 Resolved
Repair loose wire on vessel horn.
Condition: Unknown
Due 15 November 1995
Resolved 15 November 1995
Lifesaving
Issued 15 November 1995 Resolved
Put onboard four more adult lifejackets to equal COI total person count.
Condition: Unknown
Due 27 November 1995
Resolved 27 November 1995

Casualty record · 4

14 January 2010Routine · role: Involved in a Marine Casualty · activity 3860059
30 April 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 3732935
23 November 2010Routine · role: Subject of Search and Rescue · serious marine incident, as classified · 1 injured · activity 3897915
5 November 2011Routine · role: Transiting Vicinity of Primary Subject · activity 4184482
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.