Records from 1992 to 2021. Most recent: inspection, 15 March 2021.
Inspection history · 56
15 March 2021
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7158271
22 September 2020
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7063994
22 June 2020
Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6983290
9 May 2019
Internal Structural Exam · Examination of Repairs · Deficiency Check · Administrative Inspection · Drydock Exam · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6680057
16 March 2018
COI Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6372787
11 July 2017
Drydock Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6207295
13 February 2017
Deficiency Check · In-Service Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6088533
26 February 2016
Annual Inspection · Deficiency Check · Damage Survey
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5822375
25 November 2015
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5809326
24 August 2015
Internal Structural Exam · Drydock Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5224435
3 March 2014
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4808856
20 January 2012
Deficiency Check · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4229466
22 February 2011
Annual Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3949728
29 March 2010
Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3703123
20 April 2009
Hull Examination · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3456052
25 February 2009
Annual Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3423396
7 December 2007
COI Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3110947
14 February 2007
Annual Inspection · Hull Examination
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2871836
5 December 2005
Annual Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2545632
4 May 2005
Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2348827
10 March 2005
Deficiency Check · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2307000
5 November 2004
Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 2235108
14 May 2004
In-Service Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 2071684
20 January 2004
Annual Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1988132
6 January 2003
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1728342
4 December 2002
Hull Examination · COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1712777
15 January 2002
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1489603
7 December 2001
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1389520
15 March 2001
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1060505
28 February 2001
Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1366212
20 April 2000
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 817615
9 March 2000
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1046907
13 January 2000
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1048009
23 December 1999
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1046769
29 November 1999
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1442912
16 July 1999
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1098309
8 June 1999
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 806154
9 May 1999
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 796493
17 March 1999
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 807794
13 January 1999
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1364997
21 December 1998
Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1404671
15 October 1998
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 802345
2 October 1998
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 802260
15 May 1998
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 790522
5 May 1998
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 790630
14 January 1998
Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1114790
27 January 1997
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1101885
26 December 1996
Hull Examination · COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1094505
29 July 1996
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1089890
23 May 1996
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1086207
25 April 1996
Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1081109
28 April 1995
Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1184319
16 February 1995
Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1157562
16 February 1995
Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1192344
7 January 1994
Initial Certification
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1162534
1 December 1992
Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1164539
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 March 2021
No resolution recorded
Complete annual COI inspection and dry dock prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 June 2020
No resolution recorded
Repair or replace the three non operational submersible electric bilge pumps prior to the carriage of passengers.
Action required: 17 - Rectify deficiencies prior to departure
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 June 2020
No resolution recorded
Replace four adult life jackets, vessel is limited to carrying no more than 46 passengers.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 25 June 2020
No resolution recorded
Repair or replace the port and starboard navigation lights. Vessel is restricted to daytime operations.
Action required: 50 - Rectify deficiencies w/in 30 days
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 25 June 2020
No resolution recorded
Make corrections to the vessels call sign and hailing port on the Safety Radiotelephony Certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 May 2019
Resolved
Replace grab lines on the ring buoy.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 May 2019
Resolution: New ring buoy purchased.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 May 2019
Resolved
Replace the battery in the floating water light.
Action required: 705 - Other - as specified
Due 7 June 2019
Resolved 31 May 2019
Resolution: Replaced
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 30 May 2019
Resolved
Install proper lanyard with non-corrosion clip for the floating water light.
Action required: 10 - Deficiency Rectified
Resolved 31 May 2019
Resolution: Corrected.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 30 May 2019
Resolved
Repair/replace visual indicating light at the operating station for the port high-level bilge alarm.
Action required: 10 - Deficiency Rectified
Resolved 31 May 2019
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 May 2019
Resolved
Repair/replace port forward and starboard aft bilge pumps. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 31 May 2019
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 May 2019
Resolved
Properly mark bilge pump controls at the operating station.
Action required: 705 - Other - as specified
Due 7 June 2019
Resolved 5 June 2019
Resolution: Pump controls labeled.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 9 May 2019
Resolved
Secure the port side hand rail on the bow.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 May 2019
Resolution: Corrected.
Fire Fighting › Fire Bucket › Lanyard
Issued 13 February 2017
Resolved
Missing
Due 15 February 2017
Resolved 2 May 2017
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 February 2017
Resolved
Expired Meds
Due 15 February 2017
Resolved 2 May 2017
Engineering › Gasoline Engine (propulsion) › Crankcase (2 stroke)
Issued 26 February 2016
Resolved
Unauthorized / unreported engine installation.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 September 2016
Resolution: Owner installed two new (identical) outboard engines
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 26 February 2016
Resolved
Sharp metal strip along starboard side embarcation gunwhale. Require removal or repair proposal.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 September 2016
Resolved 8 September 2016
Engineering › Bilge Water Management System › Pump
Issued 3 March 2014
Resolved
Provide an operational float switch for starboard electric bilge pump.
Action required: 705 - Other - as specified
Due 10 March 2014
Resolved 3 March 2014
Communications › Alarms/Indicators › Bilge Alarm
Issued 3 March 2014
Resolved
Provide visual indicators for both bilge pumps at operating station.
Action required: 705 - Other - as specified
Due 10 March 2014
Resolved 10 March 2014
Lifesaving › Lifebuoys › Serviceable
Issued 3 March 2014
Resolved
Provide new ring buoy.
Action required: 705 - Other - as specified
Due 10 March 2014
Resolved 10 March 2014
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 3 March 2014
Resolved
Stow Type 1 PFD's indicating "Adult" or "Child" and quantity in stowage location.
Action required: 705 - Other - as specified
Due 10 March 2014
Resolved 10 March 2014
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 March 2014
Resolved
Remove dead end wiring (for old fire pump) & behind operating station though out vessel.
Action required: 705 - Other - as specified
Due 4 April 2014
Resolved 2 May 2014
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 March 2014
Resolved
Provide proper supports for electrical wiring though out vessel (24" spacing).
Action required: 705 - Other - as specified
Due 4 April 2014
Resolved 10 March 2014
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 3 March 2014
Resolved
Correct Radio Telephony Certificate with Call Sign & Port of Registry.
Action required: 705 - Other - as specified
Due 4 April 2014
Resolved 2 May 2014
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 20 January 2012
Resolved
Move stern light so that the arc of visibility is 135 degrees.
Due 20 February 2012
Resolved 27 February 2012
Resolution: Stern light moved.
Engineering › Fuel Oil Service System › Filter
Issued 20 January 2012
Resolved
Renew starboard fuel filter mount.
Due 20 February 2012
Resolved 27 February 2012
Resolution: Filter mount renewed.
Documentation › Markings/Placards › Garbage Placard
Issued 20 January 2012
Resolved
Renew MARPOL placard.
Due 20 February 2012
Resolved 27 February 2012
Resolution: MARPOL palcard renewed.
Engineering › Bilge Water Management System › Piping
Issued 20 January 2012
Resolved
Renew cross threaded plastic through hull fittings.
Due 20 February 2012
Resolved 27 February 2012
Resolution: All through hull fittings replaced with brass.
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 20 January 2012
Resolved
Properly secure starboard lifelines at starboard gangway.
Due 20 February 2012
Resolved 27 February 2012
Resolution: Lifelines secured.
Electrical › Lighting (emergency) › Conductor
Issued 20 January 2012
Resolved
Provide proper cable and splices for main deck overhead lights.
Due 20 February 2012
Resolved 27 February 2012
Resolution: Lights renewed.
Fire Fighting › Fire Bucket › Capacity
Issued 20 January 2012
Resolved
Provide three 2.5 gallon fire buckets.
Due 20 February 2012
Resolved 27 February 2012
Resolution: Fire buckets onboard.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 23 February 2011
Resolved
Condemned 35 adult and 8 child Type I PFDs. Limited passenger carriage to number of corresponding adult and child lifejackets onboard.
Due 23 February 2011
Resolved 22 March 2011
Resolution: Confirmed total 53 adult and 08 child Type I PFD''''s onboard, stowed in marked and readily accessible closet space.
Operations/Management › Passenger Operations › Safety Orientation
Issued 23 February 2011
Resolved
No passengers allowed on upper deck until stability test allows. Install warning sign at entry "no passengers allowed."
Due 23 February 2011
Resolved 22 March 2011
Electrical › Electric Supply System (service) › Cable
Issued 22 February 2011
Resolved
Ensure all circuits protected. Replace solid wiring with stranded type.
Due 9 March 2011
Resolved 22 March 2011
Engineering › Bilge Water Management System › Hose
Issued 22 February 2011
Resolved
Forward/stbd side bilge hose cracked. Replace.
Due 9 March 2011
Resolved 22 March 2011
Resolution: Cracked section removed, existing hose reinstalled. Observed satisfactory.
Construction/Loadline › Hull › Side Shell
Issued 22 February 2011
Resolved
Make permanent repairs to all temp repairs on hull exterior. Make repairs at next drydock.
Action required: 705 - Other - as specified
Resolved 13 May 2011
Operations/Management › Vessel Traffic Service › Reporting Requirements
Issued 22 February 2011
Resolved
Obtain radio station license for current vessel and owner, as per 47CFR80.
Due 9 March 2011
Resolved 22 March 2011
Resolution: New radio call sign updated on COI. Admended COI provided to vessel master for installation in visible area onboard.
Engineering › Bilge Water Management System › Pump
Issued 22 February 2011
Resolved
Mount hand bilge pump.
Due 9 March 2011
Resolved 22 March 2011
Resolution: Mounted to satisfaction of attending marine inspector.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 22 February 2011
Resolved
Ensure trim adjusted properly on port outboard engine.
Due 9 March 2011
Resolved 22 March 2011
Resolution: Adjusted trim, resulting in significantly reduced rattling when engaged in reverse.
Construction/Loadline › Hull › Hull Plating
Issued 20 April 2009
Resolved
Repair hull damage starboard hull forward of collision bulkhead.
Action required: 705 - Other - as specified
Resolved 27 April 2009
Construction/Loadline › Hull › Hull Plating
Issued 20 April 2009
Resolved
Grind, drain and repair hull cracks on both hull transom.
Action required: 705 - Other - as specified
Resolved 27 April 2009
Documentation › Certificates/Documents › Stability Letter
Issued 20 April 2009
Resolved
Conduct stability test by APRIL 01, 2010.
Action required: 705 - Other - as specified
Resolved 30 August 2010
Resolution: Vessel O/O failed to complete a stability test to maintain passenger allowance at 149. Vessel''s passenger is allowed to carry 49 pax and 2 crew members.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 20 April 2009
Resolved
Repair port seatting support forward of engine room compartment.
Action required: 705 - Other - as specified
Due 24 April 2009
Resolved 27 April 2009
Construction/Loadline › Hull › Hull Plating
Issued 20 April 2009
Resolved
Reseal transom aluminum plating on both hull.
Action required: 705 - Other - as specified
Resolved 27 April 2009
Engineering › Bilge Water Management System › Valve
Issued 20 April 2009
Resolved
Install ball valve on port forward bilge overboard.
Action required: 705 - Other - as specified
Resolved 27 April 2009
Engineering › Gasoline Engine (propulsion) › Transmission Cooling Line (4 cycle)
Issued 20 April 2009
Resolved
Install propeller locking nut and waste cutter pin.
Action required: 705 - Other - as specified
Resolved 27 April 2009
Stability › Watertight Integrity › General
Issued 20 April 2009
Resolved
Provide missing hatch capture chain.
Action required: 705 - Other - as specified
Resolved 27 April 2009
Construction/Loadline › Hull › Hull Plating
Issued 20 April 2009
Resolved
Repair port aft hull damage.
Action required: 705 - Other - as specified
Resolved 27 April 2009
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 20 April 2009
Resolved
Comply with subdivision by April 01, 2010
Action required: 705 - Other - as specified
Resolved 30 August 2010
Resolution: Vessel O/O failed to comply w/subdivision requirements for a vessel carrying more than 49 passengers. Vessel is allowed to carry 49 pax plus 2 members.
Construction/Loadline › Hull › Bracket
Issued 25 February 2009
Resolved
Repair lose ladder bracket port & starboard forward cabin.
Due 12 March 2009
Resolved 16 March 2009
Electrical › Electric Supply System (service) › Cable
Issued 25 February 2009
Resolved
Seal cable through hole for port engine.
Due 12 March 2009
Resolved 16 March 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 February 2009
Resolved
Remove death end wires in both port and starboard engine compartments.
Due 12 March 2009
Resolved 16 March 2009
Construction/Loadline › Hull › Bottom Plating
Issued 25 February 2009
Resolved
Investigate and repair water intrusion under cement weight in both the port and starboard engine compartments.
Due 30 April 2009
Resolved 24 April 2009
Construction/Loadline › Structures › Superstructure
Issued 25 February 2009
Resolved
Replace cracked forward port window.
Due 12 March 2009
Resolved 24 April 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 February 2009
Resolved
Install metal hangers for wiring in both port & starboard engine compartments.
Due 12 March 2009
Resolved 16 March 2009
Fire Fighting › Fire Main › Material
Issued 25 February 2009
Resolved
Replace wastage suction piping on fire pump.
Due 12 March 2009
Resolved 16 March 2009
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 25 February 2009
Resolved
Replace rejected all life jacket.
Action required: 705 - Other - as specified
Due 20 March 2009
Resolved 17 June 2009
Resolution: Replaced 22 new Type 1 life jackets w/ new.
Construction/Loadline › Structures › Deck Plating
Issued 25 February 2009
Resolved
Repair rotten wood frame under seating upper deck and cracked port seating main deck.
Due 20 March 2009
Resolved 16 March 2009
Resolution: Completed satisfactory repairs.
Construction/Loadline › Structures › Scuttle
Issued 25 February 2009
Resolved
Clean coaming on forward water tight hatch.
Due 12 March 2009
Resolved 26 February 2009
Documentation › Certificates/Documents › FCC SSL
Issued 18 December 2007
Resolved
Provide original FCC Station License.
Due 21 December 2007
Resolved 18 December 2007
Resolution: Provided current station license.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 18 December 2007
Resolved
Remark topside lifejacket storage.
Due 21 December 2007
Resolved 18 December 2007
Resolution: Met the requirement.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 December 2007
Resolved
Provide complete first aid kit.
Due 21 December 2007
Resolved 18 December 2007
Resolution: Met the requirement.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 18 December 2007
Resolved
Provide stern light cover.
Due 21 December 2007
Resolved 18 December 2007
Resolution: Installed new light.
Engineering › Steering Gear System › Bracket/Clamp
Issued 18 December 2007
Resolved
Secure power steering lines.
Due 21 December 2007
Resolved 18 December 2007
Resolution: Completed satisfactory repair.
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 18 December 2007
Resolved
Provide fuel shut off valve markings.
Due 21 December 2007
Resolved 18 December 2007
Resolution: Properly marked the Valve.
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 18 December 2007
Resolved
Repair fire fighting pump supply thru hull valve.
Due 21 December 2007
Resolved 18 December 2007
Resolution: Completed satisfactory repairs.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 18 December 2007
Resolved
Provide upper pax markings.
Due 21 December 2007
Resolved 18 December 2007
Resolution: Met the requirement.
Deck/Cargo › Mooring/Anchoring › Mooring Line/Hawser
Issued 18 December 2007
Resolved
Tighten portside forward cleat.
Due 21 December 2007
Resolved 18 December 2007
Resolution: Completed satisfactory repairs.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 18 December 2007
Resolved
Repair starboard side forward rail.
Due 21 December 2007
Resolved 18 December 2007
Resolution: Completed satisfactory repairs.
Fire Fighting › Remote Fuel Shutoff › General
Issued 5 December 2005
Resolved
Label Remote fuel shut off valves
Action required: 705 - Other - as specified
Due 19 December 2005
Resolved 6 January 2006
Electrical › Lighting (emergency) › Lighting Fixture
Issued 5 December 2005
Resolved
Install adequate lighting.
Action required: 705 - Other - as specified
Due 19 December 2005
Resolved 6 January 2006
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 5 December 2005
Resolved
Install visual high level indicator.
Action required: 705 - Other - as specified
Due 19 December 2005
Resolved 6 January 2006
Construction/Loadline › Hull › Side Shell
Issued 5 December 2005
Resolved
Repair hull/deck forward port side.
Action required: 705 - Other - as specified
Due 19 December 2005
Resolved 6 January 2006
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 5 December 2005
Resolved
Repair/reinforce deck railing port and starboard bow.
Action required: 705 - Other - as specified
Due 19 December 2005
Resolved 6 January 2006
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 5 December 2005
Resolved
Replace courses on bow railings.
Action required: 705 - Other - as specified
Due 19 December 2005
Resolved 6 January 2006
Construction/Loadline › Structures › Deck Plating
Issued 5 December 2005
Resolved
Repair/reinforce forward deck cleats.
Action required: 705 - Other - as specified
Due 19 December 2005
Resolved 6 January 2006
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 5 December 2005
Resolved
Repair/replace open deck seating as needed.
Action required: 705 - Other - as specified
Due 19 December 2005
Resolved 6 January 2006
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 5 December 2005
Resolved
Install protective channels on deck for thottle cables
Action required: 705 - Other - as specified
Due 19 December 2005
Resolved 6 January 2006
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 5 December 2005
Resolved
Replace retro reflective tape on lifebuoy.
Action required: 705 - Other - as specified
Due 19 December 2005
Resolved 6 January 2006
Construction/Loadline › Structures › Deck Plating
Issued 5 December 2005
Resolved
Make permenant repairs to deck aft near the ladders.
Action required: 705 - Other - as specified
Due 19 December 2005
Resolved 6 January 2006
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 10 March 2005
Resolved
Replace all retroflective tape on all life jackets.
Due 24 March 2005
Resolved 4 May 2005
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 10 March 2005
Resolved
Provide log book with logged drills.
Due 24 March 2005
Resolved 4 May 2005
Electrical › Electrical Distribution System (service) › Busway
Issued 10 March 2005
Resolved
Install cable runs to remove electric wires in bilges.
Due 24 March 2005
Resolved 4 May 2005
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 10 March 2005
Resolved
Clearly mark and identify all electric equipment on breaker panel
Due 24 March 2005
Resolved 4 May 2005
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 10 March 2005
Resolved
Provide encloaure on breaker panel.
Due 24 March 2005
Resolved 4 May 2005
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 20 January 2004
Resolved
IF USING A "BULL HORN" FOR PUBLIC ADDRESS SYSTEM; BULLHORN MUST BE MOUNTED AT HELM AND MUST BE OF RECHARGABLE BATTERY TYPE. RECHARGING MUST TAKE PLACE AT HELM STATION.
Due 7 February 2004
Resolved 10 March 2005
Engineering › Gasoline Engine (propulsion) › Ventilation
Issued 20 January 2004
Resolved
ALL PORTABLE FUEL TANKS USED ON BOARD THE VESSEL MUST BE "ABYC-H25" APPROVED.
Due 7 February 2004
Resolved 10 March 2005
Communications › Radio Communications
Issued 4 December 2002
Resolved
Prove transmitting capabilities of VHF radio. LEGACY COMPONENT DESC: VFH Radiotelephone
Due 6 January 2003
Resolved 6 January 2003
Resolution: Corrected with new radio, tested same.
Stability
Issued 4 December 2002
Resolved
Owner representative to contact MSO Guam Inspection Department to schedule a stability test for vessel.
Due 30 June 2003
Resolved 30 June 2003
Lifesaving
Issued 7 December 2001
Resolved
Obtain, and include in first aid kit, instructions in basic first aid procedures.
Condition: Unknown
Due 7 January 2002
Resolved 15 January 2002
Resolution: On board.
Lifesaving
Issued 7 December 2001
Resolved
Install a public address system on board vessel. In lieu of a fixed public address system, vessel is authorized to use a battery operated bullhorn that is constantly charged and ready to use.
Condition: Unknown
Due 7 January 2002
Resolved 15 January 2002
Resolution: Bullhorn on board.
Accommodation/Occupational Safety
Issued 28 February 2001
Resolved
Secure forward rails at port and starboard entrance points.
Condition: Unknown
Due 28 February 2001
Resolved 28 February 2001
Electrical
Issued 28 February 2001
Resolved
Replace and secure the battery box covers.
Condition: Unknown
Due 28 February 2001
Resolved 28 February 2001
Construction/Loadline
Issued 28 February 2001
Resolved
Treat termite affected wood in the forward port bow underdeck support frames.
Condition: Unknown
Due 28 February 2001
Resolved 28 February 2001
Construction/Loadline
Issued 28 February 2001
Resolved
Make repairs to cracks in the fiberglass of the port and starboard bows including replacing the soft wood on the outboard side of the starboard bow.
Condition: Unknown
Due 28 February 2001
Resolved 28 February 2001
Construction/Loadline
Issued 13 January 2000
Resolved
Repair starboard hull stem damage caused by vessel mooring operations. Prior to initiating repairs, operator must obtain Coast Guard approval of repair procedures. All repairs must be completed by 29FEB00.
Condition: Unknown
Due 13 January 2000
Resolved 13 January 2000
Lifesaving
Issued 29 November 1999
Resolved
Post lifejacket donning placard for the second type/style of lifejacket carried on board the vessel.
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Engineering
Issued 29 November 1999
Resolved
Call MSO Guam, 339-2001, extension 165, to schedule underway man-overboard and fire drills.
Condition: Unknown
Due 10 December 1999
Resolved 29 November 1999
Resolution: Item previously cleared prior to MISLE migration.
Fire Fighting
Issued 29 November 1999
Resolved
Obtain and install brass nozzle for vessel fire hose.
Condition: Unknown
Due 29 November 1999
Resolved 2 December 1999
Fire Fighting
Issued 29 November 1999
Resolved
Obtain and install marine type holders, or other approved method, for the portable fire extinguishers on board.
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Construction/Loadline
Issued 29 November 1999
Resolved
Repair starboard hull stem damaged due to mooring operations.
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Electrical
Issued 29 November 1999
Resolved
Install anchoring device for batteries to prevent shifting in rough weather.
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Lifesaving
Issued 29 November 1999
Resolved
Mark upper deck passenger limit markings above starboard ladder.
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Lifesaving
Issued 29 November 1999
Resolved
Install two more courses of line/cable at passenger aft port and starboard access.
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Lifesaving
Issued 29 November 1999
Resolved
After section of bow rail, port and starboard side, needs to be resecured due to looseness of the anchor fasteners.
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Lifesaving
Issued 29 November 1999
Resolved
Install a locking mechanism for the port and starboard bow gates.
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Lifesaving
Issued 29 November 1999
Resolved
Secure loose ladder treads on ladders leading to the upper deck.
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Construction/Loadline
Issued 9 May 1999
Resolved
Provide proof of installation of bilge hi-level alarm & indicators meeting 46 CFR 182.530 for each space with a through hull fitting, machinery space,or space with a non-watertight hatch. Vessel COI will be revoked & vessel limited to nmt 6 passengers without proof of installation by 10JUN99.
Condition: Unknown
Due 9 May 1999
Resolved 9 May 1999
Lifesaving
Issued 13 January 1999
Resolved
Put two sources of portable emergency lights on board the vessel.
Condition: Unknown
Due 13 January 1999
Resolved 13 January 1999
Engineering
Issued 13 January 1999
Resolved
Provide proof the existing fuel hose meets 46 CFR 182.720(c), i.e., USCG approved Type A1, A2, B1, or B2 flexible fuel hose, or replace hose with known approved type.
Condition: Unknown
Due 13 January 1999
Resolved 13 January 1999
Resolution: Item previously cleared prior to MISLE migration.
Navigation
Issued 13 January 1999
Resolved
Prove operation of stern light and mast head light.
Condition: Unknown
Due 13 January 1999
Resolved 13 January 1999
Lifesaving
Issued 13 January 1999
Resolved
Replace existing undersized ring buoy located on bridge with a proper ring buoy of at least 24" in diameter. New ring buoy to have retroreflective tape and vessel name on it.
Condition: Unknown
Due 13 January 1999
Resolved 13 January 1999
Engineering
Issued 21 December 1998
Resolved
Remove old wire and fuel lines from previously installed outdrive engines.
Condition: Unknown
Due 21 December 1998
Resolved 21 December 1998
Resolution: Item previously cleared prior to MISLE migration.
Construction/Loadline
Issued 21 December 1998
Resolved
Make proper repairs to both port and starboard wooden bow fenders.
Condition: Unknown
Due 7 January 1999
Resolved 7 January 1999
Construction/Loadline
Issued 21 December 1998
Resolved
Repair the two areas of port hull, mid body bottom, that show delamination of prior repairs.
Condition: Unknown
Due 7 January 1999
Resolved 7 January 1999
Construction/Loadline
Issued 21 December 1998
Resolved
Repair two fractures, ea approx 4"in length, located at stern in area od engine mounting plates, top, inboard side.
Condition: Unknown
Due 7 January 1999
Resolved 7 January 1999
Fire Fighting
Issued 2 October 1998
Resolved
Prove the satisfactory operation of the installed fire pump to the satisfaction of the attending Coast Guard marine inspector. The vessel is limited to the carriage of no more than 49 passengers until satisfactory completion of this requirement.
Condition: Unknown
Due 2 October 1998
Resolved 2 October 1998
Lifesaving
Issued 14 January 1998
Resolved
Provide passenger safety orientatin prior to vessel getting underway. Orientation shall include location of safety equipment, pfds, and pointing out of crew members that will assist passengers in case of emergency.
Condition: Unknown
Due 14 January 1998
Resolved 14 January 1998
Unknown
Issued 14 January 1998
Resolved
Start maintaining vessel log on board vessel. Enteries shall include, but not be limited to the following; firefighting drills, man overboard drills,passenger count, and repair to any primary lifesaving gear.
Condition: Unknown
Due 14 January 1998
Resolved 14 January 1998
Fire Fighting
Issued 14 January 1998
Resolved
Provide brass nozzle for fire hose.
Condition: Unknown
Due 14 January 1998
Resolved 14 January 1998
Fire Fighting
Issued 14 January 1998
Resolved
Provide valve for fire station.
Condition: Unknown
Due 14 January 1998
Resolved 14 January 1998
Accommodation/Occupational Safety
Issued 14 January 1998
Resolved
Repair cracks in passenger seating.
Condition: Unknown
Due 14 January 1998
Resolved 14 January 1998
Accommodation/Occupational Safety
Issued 14 January 1998
Resolved
Resecure forward deck rails to main deck.
Condition: Unknown
Due 14 January 1998
Resolved 14 January 1998
Lifesaving
Issued 14 January 1998
Resolved
Post lifejacket donning placards for both style of lifejackets carried on board.
Condition: Unknown
Due 14 January 1998
Resolved 14 January 1998
Lifesaving
Issued 14 January 1998
Resolved
Obtain sufficient amount of 3"x3" and 2"x2" bandages for 1st aid kit.
Condition: Unknown
Due 14 January 1998
Resolved 14 January 1998
Fire Fighting
Issued 14 January 1998
Resolved
Prove adequate discharge pressure for the fire pump. Until such time that the vessel can prove adequate pressure, the vessel must carry three (3) 2- 1/2 gallon "fire buckets" with lanyard attached.
Condition: Unknown
Due 14 January 1998
Resolved 14 January 1998
Lifesaving
Issued 14 January 1998
Resolved
Separate child sized lifejackets from adult sized lifejackets in their respective storage areas to preclude possible mix-up in emergency.
Condition: Unknown
Due 14 January 1998
Resolved 14 January 1998
Lifesaving
Issued 14 January 1998
Resolved
Mark the appropriate number af adult and child lifejackets in their respective locations of stowage.
Condition: Unknown
Due 14 January 1998
Resolved 14 January 1998
Lifesaving
Issued 14 January 1998
Resolved
Prove operation of waterlight on ring buoy. Vessel is restricted to daylight operations only until such time waterlight is proven operational.
Condition: Unknown
Due 14 January 1998
Resolved 14 January 1998
Lifesaving
Issued 14 January 1998
Resolved
Replace ring buoy grab lines that have deteriated due to weathering, or replace ring buoy. If reattaching grab lines, ensure proper stitching and thread is used in the repair.
Condition: Unknown
Due 14 January 1998
Resolved 14 January 1998
Lifesaving
Issued 14 January 1998
Resolved
Provide "portable" emergency source of lighting, i.e., two flashlights.
Condition: Unknown
Due 14 January 1998
Resolved 14 January 1998
Navigation
Issued 26 December 1996
Resolved
Prove operation of mooring light.
Condition: Unknown
Due 26 December 1996
Resolved 26 December 1996
Unknown
Issued 26 December 1996
Resolved
Mark vessel name on stern of vessel, and on ring bouy located on bridge.
Condition: Unknown
Due 26 December 1996
Resolved 26 December 1996
Fire Fighting
Issued 26 December 1996
Resolved
Obtain nozzle for "fire hose".
Condition: Unknown
Due 26 December 1996
Resolved 26 December 1996
Lifesaving
Issued 26 December 1996
Resolved
Obtain eight (8) more adult sized life jackets to bring total up to 153. Until such time, vessel is restricted to not more than 145 total persons.
Condition: Unknown
Due 26 December 1996
Resolved 26 December 1996
Documentation
Issued 26 December 1996
Resolved
Show proof of vessel documentation by the presence of vessel documentation sticker on the Certificate of Documentation.
Condition: Unknown
Due 26 December 1996
Resolved 26 December 1996
Fire Fighting
Issued 25 April 1996
Resolved
Have all fire extinguishers serviced.
Condition: Unknown
Due 25 April 1996
Resolved 25 April 1996
Engineering
Issued 25 April 1996
Resolved
Lable fuel emergency cutoff valves, show direction of rotation.
Condition: Unknown
Due 25 April 1996
Resolved 25 April 1996
Accommodation/Occupational Safety
Issued 25 April 1996
Resolved
Repair all cracked seating.
Condition: Unknown
Due 25 April 1996
Resolved 25 April 1996
Accommodation/Occupational Safety
Issued 25 April 1996
Resolved
Mark number of, and type of PFDs at location.
Condition: Unknown
Due 25 April 1996
Resolved 25 April 1996
Fire Fighting
Issued 25 April 1996
Resolved
Obtain and install one more B-II fire extinguisher to bring inline with COI
Condition: Unknown
Due 25 April 1996
Resolved 25 April 1996
Documentation
Issued 25 April 1996
Resolved
Have FCC safety radiotelephone inspection.
Condition: Unknown
Due 25 April 1996
Resolved 25 April 1996
Navigation
Issued 25 April 1996
Resolved
Prove operation of mast head light.
Condition: Unknown
Due 25 April 1996
Resolved 25 April 1996
Accommodation/Occupational Safety
Issued 7 January 1994
Resolved
install proper exhaust duct to the bilge area in both of the enginerooms.
Condition: Unknown
Due 7 January 1994
Resolved 7 January 1994