Records from 2006 to 2026. Most recent: inspection, 27 May 2026.
Inspection history · 29
27 May 2026
Re-Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8395912
26 February 2026
Vessel Attendance · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8293719
9 March 2025
Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8160998
27 February 2025
COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8058899
20 November 2024
Re-Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8042431
20 May 2024
Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7925867
9 January 2024
MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7846961
9 January 2024
Hull Examination · Internal Structural Exam · Examination of Repairs · Drydock Extension
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7847205
15 December 2023
Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7845020
2 March 2023
COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7622508
9 January 2023
Re-Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7623641
24 May 2022
DAPI Audit
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7459527
31 January 2022
MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7388203
14 December 2021
Re-Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7368035
8 October 2021
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7360122
3 March 2021
COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7130219
16 December 2020
Periodic Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7116975
5 March 2020
MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6906707
4 November 2019
MTSA Verification · Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6844347
17 May 2019
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6686431
20 February 2019
COI Inspection · Deficiency Check · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6628840
5 February 2019
Drydock Extension
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6620235
7 March 2018
COI Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6360562
22 December 2017
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6328121
22 December 2017
Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6331328
13 March 2017
DAPI Audit · MTSA Verification · Administrative Inspection · COI Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6082260
6 December 2016
In-Service Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6053543
7 November 2016
Administrative Inspection · Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6063504
15 March 2016
Administrative Inspection · COI Inspection · DAPI Audit · MTSA Verification
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5831275
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 26 February 2026
Resolved
One painter on a rescue boat must be attached by a painter release device at the forward end of the boat. The release device was seized. Affect repairs to the satisfaction of the attending marine inspectror
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 March 2026
Resolution: The release device was properly repaired.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 26 February 2026
Resolved
General emergency alarm signal must be located in passenger areas where they can alert persons in spaces. The general alarm bell outside the starboard house was inoperable. Affect repairs to the satisfaction of the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 March 2026
Resolution: The general alarm bell was repaired.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 26 February 2026
Resolved
Vital systems that are automatically or remotely controlled must be provided with an alarm system for detection of a failure or unsafe condition. The audible summary alarm for the starboard generator was inoperable. Affect repairs to the the satisfaction of the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2026
Resolved 6 April 2026
Resolution: Summary alarm was repaired
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 February 2025
Resolved
Rudden angle indicator would not exceed ~20 degrees P/S when in follow-up mode. Prove full travel of rudden in follow-up mode. 46 CFR 58.25-10
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2025
Resolved 9 March 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 29 February 2024
Resolved
Provide valid FCC Safety Cert.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 March 2024
Resolved 12 April 2024
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 29 February 2024
Resolved
Provide valid FCC Bridge to Bridge cert.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 March 2024
Resolved 12 April 2024
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 29 February 2024
Resolved
Paint Rescue Boat (next credit drydock).
Action required: 705 - Other - as specified
Due 31 May 2024
Resolved 6 August 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 March 2021
Resolved
Repair leaky valve stem on F.S. #2.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 April 2021
Resolved 8 March 2021
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 3 March 2021
Resolved
Post mrequired IMO symbols on lifesaving equipment locations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 April 2021
Resolved 8 March 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 March 2021
Resolved
Post donning placards on upper deck stowage areas.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 April 2021
Resolved 8 March 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 November 2019
Resolved
Replace the grab line around the port/ 01 deck buoy.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 December 2019
Resolved 25 November 2019
Resolution: Buoy replaced
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 November 2019
Resolved
Replace the line for the waterlight for the port bridge wing buoy.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 December 2019
Resolved 25 November 2019
Resolution: Replaced
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 November 2019
Resolved
Repair or replace the aft ring buoy on the stern.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 December 2019
Resolved 25 November 2019
Resolution: Buoy replaced
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 4 November 2019
Resolved
Provide markings on the resuce boat: vessel's name P/S on the bow, and the capacity on the gunwale.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 December 2019
Resolved 25 November 2019
Resolution: Corrected
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 6 March 2019
Resolved
Provide the Engine Room Alarm Panel on the emergency power source.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 April 2019
Resolved 29 August 2019
Resolution: done
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 6 March 2019
Resolved
Repair the alarm buzzer for the boiler alarm panel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 April 2019
Resolved 29 August 2019
Resolution: corrected
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 6 March 2019
Resolved
Replace the flexible hoses on both gensets for the keel cooler attachement; provide a SAE J-1942 type hose or equivlant.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 May 2019
Resolved 29 August 2019
Resolution: Done
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 6 March 2019
Resolved
Repair broken lights on bridge machinery alarm panel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 April 2019
Resolved 29 August 2019
Resolution: Done
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 March 2019
Resolved
Provide reflective tape on ring buoy (starboard bridge wing).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 April 2019
Resolved 29 August 2019
Resolution: Done
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 6 March 2019
Resolved
Prove operation of light fixture on 01 level catwalk, port side IWO aft ring buoy.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 April 2019
Resolved 29 August 2019
Resolution: Done
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 March 2019
Resolved
Provide PFD donning placards at upper level stowage locations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 April 2019
Resolved 29 August 2019
Resolution: Placed inside storage containers
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 6 March 2019
Resolved
Label upper decks with maximum passenger capacity IAW stability letter.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 April 2019
Resolved 29 August 2019
Resolution: Done
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 7 March 2018
Resolved
Provide FCC Safety Certificate to address taped on dates.
Action required: 705 - Other - as specified
Due 7 April 2018
Resolved 10 April 2018
Resolution: Attended vessel. Form was corrected.
Fire Fighting › Nozzles › Condition
Issued 7 March 2018
Resolved
Prove operation of nozzle on F.S #2 (extremely stiff).
Action required: 705 - Other - as specified
Due 21 March 2018
Resolved 10 April 2018
Resolution: Attended vessel. Nozzle tested sat.
Lifesaving › Launching Appliances › Davit
Issued 7 March 2018
Resolved
Provide servicing report from OEM authorized technician attesting to the satisfactory arrangement and operation of the rescue boat davit/dead mans brake.
Action required: 705 - Other - as specified
Due 21 March 2018
Resolved 20 March 2018
Resolution: Received OEM tech report.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 March 2018
Resolved
Update expired first aid kit contents in rescue boat.
Action required: 705 - Other - as specified
Due 21 March 2018
Resolved 10 April 2018
Resolution: Attended vessel. Contents updated.
Operations/Management › Drills/Instruction › Launching/Recovery of Survival Craft
Issued 7 March 2018
Resolved
Conduct boat drill with USCG attendance.
Action required: 705 - Other - as specified
Due 7 April 2018
Resolved 10 April 2018
Resolution: Attended vessel. Conducted satisfactory MOB/Boat drill.
Navigation › Piloting/Steering › Deviation Table/Graph
Issued 7 March 2018
Resolved
Provide updated deviation card.
Action required: 705 - Other - as specified
Due 7 April 2018
Resolved 28 March 2018
Resolution: Received updated card.
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 22 December 2017
Resolved
Prove proper operation of #2 generator curcuit breaker
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 December 2017
Resolved 22 December 2017
Resolution: Replaced circuit breaker phase "B" to bus bar contacter. Tested sat.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 14 March 2017
Resolved
vessel did not have valid COD
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 March 2017
Resolved 17 March 2017