Records from 2002 to 2007. Most recent: inspection, 17 September 2007.
Documentation record
Registered dimensions (L × B × D)168.0 ft × 75.0 ft × 12.5 ft
Registered tonnagegross 1,336 / net 400
ITC dimensions (L × B × D)168.0 ft × 75.0 ft × 12.5 ft
ITC tonnagegross 1,336 / net 400
BuilderHALTER MARINE INC · MOSS POINT, MS, UNITED STATES · built 1991
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMORGAN CITY, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 8 July 2026 · expires 31 July 2027
Service, as the file records itOffshore Supply Vessel
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1336 - Convention (Subpart B), Gross Ton
400 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 17 September 2007
Resolved
Barge didn't have a workable drain plug - rusted in the open position - improper containment
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2007
Fire Fighting › Fire Hydrants › Condition
Issued 17 September 2007
Resolved
Converted to washdown system
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2007
Fire Fighting › Combustible Materials › Matresses
Issued 17 September 2007
Resolved
Matresses - Improper Installation
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 17 September 2007
Resolved
Was disconnected
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2007
Fire Fighting › Fire Hoses › Number
Issued 17 September 2007
Resolved
Missing both STBD/Port FF Hoses
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2007
Fire Fighting › Nozzles › Number
Issued 17 September 2007
Resolved
Missing both STBD/Port Nozzles
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2007
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 17 September 2007
Resolved
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2007
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 17 September 2007
Resolved
Numerous CO2 Fire Ext not secured - rolling about the deck
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 September 2007
Resolved
Numerous bare wires about the barge.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2007
Engineering › Bilge Water Management System › Manifold
Issued 17 September 2007
Resolved
Not marked/labeled
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2007
Engineering › Pressure Vessel › Coast Guard Symbol
Issued 17 September 2007
Resolved
Coast Guard Symbol - Placed in Improper Service
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2007
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 17 September 2007
Resolved
Expired
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2007
Lifesaving › Inflatable Liferafts › Servicing
Issued 17 September 2007
Resolved
Expired in 2005
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2007
Lifesaving › Lifebuoys › Immediately Available
Issued 17 September 2007
Resolved
Thrown about the decks - Not Secured
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2007
Lifesaving › Buoyant Apparatus › Float Free
Issued 17 September 2007
Resolved
Life Rafts were tied to the barge and weren't float free.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2007
Lifesaving › Buoyant Apparatus › Marking
Issued 17 September 2007
Resolved
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2007
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 17 September 2007
Resolved
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2007
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 17 September 2007
Resolved
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2007
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 17 September 2007
Resolved
Storage not marked.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2007
Lifesaving › Lifejacket/PFD (Type III) › Lights
Issued 17 September 2007
Resolved
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2007
Lifesaving › Lifejacket/PFD (Type III) › Marking
Issued 17 September 2007
Resolved
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2007
Lifesaving › Lifejacket/PFD (Type III) › Quantity
Issued 17 September 2007
Resolved
Didn't have sufficient PFDs for personnel onboard.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2007
Documentation › Certificates/Documents › Certificate of Inspection
Issued 17 September 2007
Resolved
Didn't have required COI
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2007
Communications › Alarms/Indicators › General Alarm
Issued 17 September 2007
Resolved
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2007
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 17 September 2007
Resolved
Bunks made out of wood.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2007
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 17 September 2007
Resolved
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2007
Accommodation/Occupational Safety › Sleeping Accommodations › Locker
Issued 17 September 2007
Resolved
Locker - Missing
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2007
Accommodation/Occupational Safety › Washroom/Toilet › Number Per Persons
Issued 17 September 2007
Resolved
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2007
Operations/Management › Navigation Safety › Proper Use of Navigation/Anchor Lights
Issued 17 September 2007
Resolved
Port/Stbd/Aft Nav Lights were In-Op
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2007
Documentation › Certificates/Documents › Coastwise Load Line Certificate
Issued 17 September 2007
Resolved
Operating outside of the scope of the LL Cert.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2007