CONFIDENCE I

CONFIDENCE I is a 1992 freight ship. The Coast Guard has recorded 23 inspections since 1993, most recently in July 2009, along with 15 deficiencies and 5 operational controls.

Records from 1993 to 2009. Most recent: inspection, 30 July 2009.

Built
1992
Last inspected
30 July 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9044009 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
386911
Flag
GERMANY
—
Maury page id
psix-386911

Inspections, by type

…with no type recorded18
Years with a record 12 calendar years (1993–2009)
The 23 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it13696 - Convention (Subpart B), Gross Ton
7791 - Convention (Subpart B), Net Ton
27273 - Displacement, Ton
22150 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 23

30 July 2009 MARPOL Annex VI Survey · MARPOL Annex I Examination · Deficiency Check · ISPS II Exam · MARPOL Annex V Examination · Ballast Water Examination · COE-Dockside
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3545209
30 July 2009 Type not recorded
No type recorded · USCGC PELICAN (WPB 87327) · USCG Heartland District (CGD-H) · Activity 3565507
29 July 2009 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3545214
25 July 2009 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3545441
11 September 2006 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2775349
12 October 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2222539
7 August 2004 ISPS II Exam · Ballast Water Examination · NPV Safety Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2158191
18 March 2004 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2029577
28 January 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1999334
26 January 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1999291
25 April 2003 Passenger/Freight Vessel Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1776264
13 February 2002 Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1486362
29 February 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 275307
2 November 1999 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 646908
14 October 1999 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 433712
3 December 1998 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 423024
9 January 1998 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 411181
9 September 1997 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 407702
19 December 1995 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 385775
1 November 1995 Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 384470
17 January 1995 Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 374115
1 December 1994 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 372787
7 May 1993 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 358101

Deficiency record · 15

Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 30 July 2009 Resolved
0740-Class to attest to crew installed priming/head tank arrangement for emergency fire pump. SOLAS 74 am. I/11
Action required: 705 - Other - as specified
Due 12 August 2009
Resolved 2 August 2009
Resolution: Received, reviewed and accepted Class Report.
Deck/Cargo › Cargo Stowage › General
Issued 30 July 2009 Resolved
1299- PSCO observed there was excessive combustible oils, solvents, improperly stored compressed gases, dunnage and debris located throughout the space. Remove all excessive combustible oils, solvents, improperly stored compressed gases, dunnage and debris located throughout the space and properly store and dispose of ashore. SOLAS 74 am. II-I/15 (MSC 647)
Action required: 705 - Other - as specified
Due 6 August 2009
Resolved 2 August 2009
Resolution: Received, reviewed and accepted Class Report.
Engineering › Sea-water System (primary cooling) › Piping
Issued 30 July 2009 Resolved
1499-During the inspection of the main space it was observed by the PSCO that there were two temporary doublers on the raw water fed line to SSG. #1 and #2 heat exchangers. Conduct permanent repairs. SOLAS 74 am. II/I-15 (MSC 647)
Action required: 705 - Other - as specified
Due 13 August 2009
Resolved 2 August 2009
Resolution: Received Class Report satisfying the requirement.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 30 July 2009 Resolved
1730-During testing of the oily water separator it was observed that there was difficulty in carrying out the procedure. After several attempts iaw the testing procedures it was discovered that there was blockage of oil residue in the feed line to the optic eye, clean and re-install. Prove proper operation in all modes of service. MARPOL 73/78 Art. 5
Action required: 705 - Other - as specified
Due 13 August 2009
Resolved 2 August 2009
Resolution: Received, reviewed and accepted Class Report.
Construction/Loadline › Structures › Door
Issued 30 July 2009 Resolved
1299-During the deck inspection it was observed that there were several fractured welds on hatches #2 and #3. On cargo coaming hatch #2, the fractures were located at the aft, outer most web framings port and starboard side two of the first horizontal strong back. on cargo coaming hatch #3, the fractures were located at the forward most port side. Make permanent repairs. ICLL Reg. 1
Action required: 705 - Other - as specified
Due 13 August 2009
Resolved 2 August 2009
Resolution: Received, reviewed and accepted Class Report.
Fire Fighting › Ventilation Systems › Ducts
Issued 11 September 2006 Resolved
When entering the Co2 room, the ventilation hatch was opened and sea water came pouring out of it. The rubber seal was replaced on the spot. Inside the Co2 room there was a spot in the ducting were the sea water was sitting that was rusted and sea water was coming through. The deck underneath was wasted, paint was pealing, and mold was all over the walls. Vessel shall repair ducting.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 October 2006
Resolved 19 September 2006
Resolution: Class report received. All Sat.
Operations/Management › Drills/Instruction › Fire
Issued 11 September 2006 Resolved
Unsatisfactory fire drill in response to the galley. Solas 2001 cons. III/3.4.1
Action required: 17 - Rectify deficiencies prior to departure
Due 16 September 2006
Resolved 14 September 2006
Resolution: Satisfactory drill conducted.
Documentation › Certificates/Documents
Issued 13 February 2002 Resolved
STCW Certificates / Licences not in compliance with STCW 78, amended 95, required effective 01FEB02. Issued Letter of Warning
Action required: 705 - Other - as specified
Due 25 April 2003
Resolved 25 April 2003
Documentation › Certificates/Documents
Issued 13 February 2002 Resolved
STCW Certificates / Licences not in compliance with STCW 78, amended 95, required effective 01FEB02. Issued Letter of Warning
Action required: 705 - Other - as specified
Due 13 February 2002
Resolved 13 February 2002
Construction/Loadline
Issued 14 October 1999 Resolved
ONE FRACTURE IN STARBOARD AFT #2 HATCH COAMING TRANSITION AND ONE IN #3 STARBOARD FWD HATCH COAMING.
Condition: Unknown
Due 1 March 2000
Resolved 1 March 2000
Lifesaving
Issued 14 October 1999 Resolved
FWD BOSN STORE IS BEING USED AS A PAINT/FLAMMABLE LIQUID LOCKER BUT DOES NOT CONTAIN PROPER FIRE SUPPRESSION ARRANGEMENTS.
Condition: Unknown
Due 1 March 2000
Resolved 1 March 2000
Construction/Loadline
Issued 14 October 1999 Resolved
A HALF METER FRACTURE ON PORT RAISED BULWARK NEAR THE NUMBER 2 AND 3 CARGO HATCHES.
Condition: Unknown
Due 1 March 2000
Resolved 1 March 2000
Navigation
Issued 14 October 1999 Resolved
NAVIGATION OF VESSEL IN U.S. WATERS WITHOUT PROPER CHARTS. SPECIFICALLY EITHER CHART # 17316 OR 17312.
Condition: Unknown
Due 14 October 1999
Resolved 14 October 1999
Navigation
Issued 9 September 1997 Resolved
Provide proper chart and size for area transitted in Hawk Inlet.
Condition: Unknown
Due 9 September 1997
Resolved 9 September 1997
Lifesaving
Issued 9 September 1997 Resolved
Vessel missing two thermal protection devices according to vessel's safety certificate. Vessel has six on board which meets the requirements of SOLAS, but not class certificate.
Condition: Unknown
Due 12 January 1998
Resolved 12 January 1998

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.