Records from 2007 to 2025. Most recent: inspection, 9 April 2025.
Inspection history · 26
9 April 2025
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8108497
7 January 2025
Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8059603
27 February 2024
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7871054
24 June 2023
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7725094
2 May 2023
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7607304
11 January 2023
Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7585253
16 February 2022
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7385775
18 January 2022
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7382141
7 June 2021
Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7218736
20 April 2021
COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7166495
20 January 2021
Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7120486
19 August 2020
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7035970
22 August 2019
Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6795172
23 May 2019
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6691938
22 January 2019
Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6569084
10 December 2018
Damage Survey
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6596874
10 December 2018
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6602874
13 March 2018
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6362132
12 January 2018
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6344336
13 May 2017
Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6145514
13 May 2017
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6152907
20 March 2017
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6102056
9 March 2017
Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6097187
15 November 2016
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6041913
6 November 2016
Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6037086
28 April 2016
COI Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5865148
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 16 February 2022
Resolved
A vessel must comply with the applicable requirements
for any radio and Electronic Position Indicating
Radiobeacon (EPIRB) installations, including the
requirements for a station license and installation
certificates to be issued by the Federal Communications
Commission, as set forth in 47 CFR part 80. Vessel did
not have valid Safety Radiotelephony Certificate onboard.
Provide proof of satisfactory Safety Radiotelephony Certificate to attending Marine Inspector
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 March 2022
Resolved 17 March 2022
Resolution: Provided proof of satisfactory Safety Radiotelephony Certificate to attending Marine Inspector
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 16 February 2022
Resolved
A vessel must comply with the applicable requirements
for any radio and Electronic Position Indicating
Radiobeacon (EPIRB) installations, including the
requirements for a station license and installation
certificates to be issued by the Federal Communications
Commission, as set forth in 47 CFR part 80. Vessel's
station license MMSI didn't coincide w/ installed radio.
Provide proof of satisfactory radio station license to
attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 March 2022
Resolved 17 March 2022
Resolution: Provided proof of satisfactory radio station license to attending Marine Inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 February 2022
Resolved
The owner, charterer, master or managing operator shall
instruct each crew member, at least once every three
months, as to the duties that the crew member is
expected to perform in an emergency including, but not
limited to, the emergency instructions listed on the emergency instruction placard required by 46 CFR
185.510. Each EPIRB must be tested monthly using the
integrated test circuit and output indicator, to
determine that it is operative. Vessel was not able to
show more than 01 set of logged drills and EPIRB tests.
Provide next logged drills and EPIRB tests to the
attending Marine Inspector & continue as internal policy
as required by the regulations.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 March 2022
Resolved 25 February 2022
Resolution: New drills logged and provided.
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 21 April 2021
Resolved
Bilge high level alarm in machinery space does not have visual alarm at the operating station. Make repairs to ensure visual alarm is operational.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2021
Resolved 6 May 2021
Resolution: Vessel provided pictures showing operation of bilge high level light.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 April 2021
Resolved
Portside navigation light has an obstruction preventing it from being visible from ahead.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2021
Resolved 6 May 2021
Resolution: Vessel repositioned screen to provide proper arc of visibility.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 21 April 2021
Resolved
One life float has damaged and insufficient reflective tape.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2021
Resolved 6 May 2021
Resolution: Vessel repaired life float and replaced retro tape.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 April 2021
Resolved
Ring life buoy is missing reflective tape.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2021
Resolved 6 May 2021
Resolution: Vessel replaced retro tape.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 21 April 2021
Resolved
Vessel is missing garbage placard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2021
Resolved 6 May 2021
Resolution: Vessel provided garbage placard.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 21 April 2021
Resolved
No alcohol testing swabs or equipment available on board.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2021
Resolved 6 May 2021
Resolution: Vessel provided alcohol swabs at office on pier.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 19 August 2020
Resolved
Life floats are required two paddles for each life float. Life floats were found with one paddle each. Provide additional paddles.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2020
Resolved 31 August 2020
Resolution: Vessel provided additional paddles.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 August 2020
Resolved
Vessel is required three 2.5 gallon fire buckets with lanyards, but only two fire buckets were found on board. Provide three fire buckets with lanyards.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2020
Resolved 31 August 2020
Resolution: Vessel provided 3 fire buckets.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 19 August 2020
Resolved
EPIRB hydrostatic release was found expired. Provide current hydrostatic release.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2020
Resolved 31 August 2020
Resolution: Vessel provided new EPIRB hydrostatic release.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 23 May 2019
Resolved
Update navigational pubs.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2019
Resolved 6 June 2019
Resolution: Pubs updated.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 23 May 2019
Resolved
Provide manufactors tag on life float weak link.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 June 2019
Resolution: Tag provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 December 2018
Resolved
Prove proper operation of the main engine prior to operating with passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 December 2018
Resolved 12 December 2018
Resolution: Transmission replaced.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 13 March 2018
Resolved
Prove proper operation of Fireboy engine shutdown prior to operating with passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 March 2018
Resolved 13 March 2018
Resolution: Demonstrated proper operation of Fireboy engine shutdown.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 13 March 2018
Resolved
Provide service report for 03 portable fire extinguishers and 01 Fireboy by 31MAR18.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 March 2018
Resolved 19 March 2018
Resolution: Verified servicing of 03 portable fire extinguishers and Fireboy on 14MAR18.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 13 March 2018
Resolved
Provide copy of current employee list and 2017 MIS report for drug program.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 April 2018
Resolved 13 March 2018
Resolution: Provided current employee list and 2017 MIS report for drug program.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 13 March 2018
Resolved
Renew gasket on engine room hatch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 April 2018
Resolved 13 March 2018
Resolution: Verified renewal of gasket on E/R hatch.
Lifesaving › Hand Flares › Quantity
Issued 13 March 2018
Resolved
Provide proper count of distress flares prior to operating with passengers.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 March 2018
Resolved 13 March 2018
Resolution: Provided proper count of distress flares onboard.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 13 May 2017
Resolved
Prior to carrying passengers, make repairs as necessary to address fouled prop/shaft, and make vessel available for a check-ride by a USCG Marien Inspector to verify proper operation.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 May 2017
Resolved 13 May 2017
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 20 March 2017
Resolved
Prove proper operation of the fireboy engine shutdown.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 March 2017
Resolved 20 March 2017
Resolution: Fuse replaced, tested sat.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure
Issued 20 March 2017
Resolved
Replace B-I fire extinguisher.
Action required: 705 - Other - as specified
Due 20 March 2017
Resolved 20 March 2017
Resolution: B-I replaced.
Communications › Radio Communications › EPIRB
Issued 20 March 2017
Resolved
Provide current NOAA registration for the EPIRB.
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 20 March 2017
Resolution: EPIRB NOAA registration updated.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 20 March 2017
Resolved
Label storage location of adult lifejackets.
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 20 March 2017
Resolution: Lifejacket storage labeled.
Construction/Loadline › Hull › Side Shell
Issued 9 March 2017
Resolved
Repair top of bulwark stbd side amidships due to damage from rub rail.
Action required: 705 - Other - as specified
Due 9 April 2017
Resolved 10 April 2017
Resolution: Repair completed.
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 6 November 2016
Resolved
Recharge fireboy and provide service report prior to sailing.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 November 2016
Resolved 10 November 2016
Resolution: New fireboy installed.
Fire Fighting › Combustible Materials › Insulation
Issued 6 November 2016
Resolved
Replace damaged insulation in overhead above engine prior to sailing.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 November 2016
Resolved 10 November 2016
Resolution: Insulation replaced.
Documentation › Logs/Records › Operational Procedures for Engines or Equipment
Issued 6 November 2016
Resolved
Provide mechanics report and complete sea-trial prior to sailing.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 November 2016
Resolved 10 November 2016
Resolution: Sea-trial completed and received report.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 4 May 2016
Resolved
Provide proof of servicing for FireBoy system.
Action required: 705 - Other - as specified
Due 4 June 2016
Resolved 6 May 2016
Engineering › Bilge Water Management System › Pump
Issued 4 May 2016
Resolved
Install UL-listed bilge pump in E/R.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 June 2016
Resolved 16 August 2016
Documentation › Certificates/Documents › FCC SSL
Issued 4 May 2016
Resolved
Renew FCC SSL
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 June 2016
Resolved 18 May 2016
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 4 May 2016
Resolved
Provide FCC Radiotelephony Certificate.
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 June 2016
Resolved 18 May 2016