MAURY USCG vessel records Sign in
← All vessels

HONG YUN 9

HONG YUN 9 is a 1983 tank ship. The Coast Guard has recorded 17 inspections since 2001, most recently in January 2023, along with 13 deficiencies and 1 operational control.

Records from 2001 to 2023. Most recent: inspection, 6 January 2023.

Built
1983
Last inspected
6 January 2023
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8402436 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
SOUTH KOREA
—
Maury page id
psix-38698

Inspections, by type

…with no type recorded2
Years with a record 7 calendar years (2001–2023)
The 17 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it3055 - Convention (Subpart B), Gross Ton
1472 - Convention (Subpart B), Net Ton
5689 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 17

6 January 2023 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7617631
17 December 2008 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3381521
14 May 2008 Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3202822
20 June 2007 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2970278
13 March 2007 Ballast Water Examination · ISPS II Exam · COC-TVE Annual
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2887416
18 November 2005 ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2537382
23 December 2004 COC-TVE Annual
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2262779
22 November 2004 Random ISPS/MTSA/PSC
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2246451
21 November 2004 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2246376
22 June 2004 ISPS II Exam
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2107410
24 February 2004 Administrative Inspection
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2012558
20 January 2004 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1990964
14 December 2003 Certificate of Compliance
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1961391
30 October 2003 In-Service Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1940626
2 June 2003 Certificate of Compliance
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1803136
1 December 2001 Certificate of Compliance
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 295719
26 November 2001 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1475225

Deficiency record · 13

Engineering › Shafting/Propeller Arrangements › Propeller (controllable pitch)
Issued 17 December 2008 Resolved
The seal on the controllable pitch propeller hydrolic oil supply block is weaking excessive amounts of oil.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 December 2008
Resolution: Coast Guard inspector [name withheld] attended the vessel and cleared the deficiency.
Documentation › Safety Management System › Key Shipboard Operations Plans/Instructions
Issued 13 March 2007 Resolved
The vessels Fire Control Plan was inaccurate. A space marked as an accomodation space on Fire Control Plan was labeled as deck storage on the vessel. The FCP was stamped with an approval date of 2000.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 June 2007
Resolution: Deficiencies rectified via class report.
Fire Fighting › Emergency Fire Pumps › Power Source
Issued 22 November 2004 Resolved
Emergency fire pump is not in proper working order and not ready for immediate use. Solas Ch. II-2 Reg. 14.2.1.2
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 November 2004
Resolution: The emergency fire pump was examined by the classification society, operationally tested and found satisfactory.
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 22 November 2004 Resolved
Engine room has excessive oil on cylinders and bilges. Solas Ch I Reg. 11 (a).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 November 2004
Resolution: The engine room was examined by coast guard inspectors and found satisfactorily free from excessive oil.
Engineering › Fuel Oil Service System
Issued 14 December 2003 Resolved
1499 Repair jacketed fuel oil piping of main engine. IAW SOLAS II-2 Reg.15.7.(8) Clear to the satisfaction of class. LEGACY COMPONENT DESC: Piping
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 27 January 2004
Resolution: class report
Construction/Loadline › Structures
Issued 14 December 2003 Resolved
1270 Watertight door dogs need maintenance, pumproom and paint locker were unsat. IAW ILLC 66 Annex 1/15. Clear to the satisfaction of class. LEGACY COMPONENT DESC: Door
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 27 January 2004
Resolution: CLASS REPROT AND VISUAL EXAMINATION
Accommodation/Occupational Safety › Sleeping Accommodations
Issued 14 December 2003 Resolved
99 Replace sink in No.1 oiler berthing. IAW ILO 147 LEGACY COMPONENT DESC: Berth
Condition: Placed in Improper Service
Action required: 15 - Rectify deficiencies by next port
Resolved 27 January 2004
Resolution: VISUAL EXAMINATION OF NEW SINK
Accommodation/Occupational Safety › Medical/First Aid
Issued 14 December 2003 Resolved
70 Prove operation of toilet in hospital space. IAW ILO 147 LEGACY COMPONENT DESC: Hospital Space
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 27 January 2004
Resolution: VISUAL EXAMINATION OF WORKING TOILET
Personnel › Certificates/Documents/Licenses
Issued 14 December 2003 Resolved
20 Provide documentation from flag state recognizing the training for all officers and ratings required by safe manning document. IAW ILO 147
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 27 January 2004
Resolution: CLASS REPORT
Operations/Management › Lifesaving
Issued 14 December 2003 Resolved
99 Provide safety escape harness for pumproom. IAW 46 CFR CH.1 35.30-20
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 27 January 2004
Resolution: HARNESS PROVIDED AND PROPER USE DEMONSTRATED
Fire Fighting › Combustible Materials
Issued 14 December 2003 Resolved
0999 Provide class report attesting to fire integrity adequacy of wood bulkheads on starboard side, forward of house at railing for cargo handling area. IAW SOLAS II-2 Reg 58 Clear to the satisfaction of class.
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Resolved 27 January 2004
Resolution: CLASS REPORT
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 3 November 2003 Resolved
Sanitize ship to remove all roaches from galley and provision spaces.
Action required: 15 - Rectify deficiencies by next port
Due 27 January 2004
Resolved 27 January 2004
Resolution: VISUAL INSPECTION
Deck/Cargo › Cargo Stowage
Issued 3 November 2003 Resolved
Secure drums on deck at port gangway forward/outboard of liferaft and place on raised platform. Drums must be moved to provide access to the life-ring and secage pump emergency shut down.
Action required: 15 - Rectify deficiencies by next port
Resolved 27 January 2004
Resolution: VISUAL INSPECTION FIXED

Ownership record