Records from 1993 to 2010. Most recent: inspection, 23 February 2010.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 21
23 February 2010
Type not recorded
No type recorded · Station Key West · USCG Southeast District (CGD-SE) · Activity 3685953
29 March 2006
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2612226
27 January 2005
Re-Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2283482
28 June 2004
Examination of Repairs · Hull Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 2113377
24 September 2003
COI Inspection · Deficiency Check · MARPOL Annex V Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1912097
12 March 2003
Administrative Inspection
Administrative · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1756136
30 July 2002
Deficiency Check · Hull Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1670188
15 May 2002
MARPOL Annex V Examination · Administrative Inspection · Re-Inspection
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1616791
16 November 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 39622
28 March 2001
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1449461
21 July 1998
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1129634
2 December 1997
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 775747
28 July 1997
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 784130
24 June 1997
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 777164
31 May 1996
Hull Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1181265
20 March 1996
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 885923
23 February 1995
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1158608
27 January 1995
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1136996
8 March 1994
Hull Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 856447
23 February 1994
Inclining Experiment
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 856448
12 April 1993
Type not recorded
No type recorded · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 692627
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 27 January 2005
Resolved
Replace fire extinguisher bracket at operating station.
Action required: 705 - Other - as specified
Due 27 February 2005
Resolved 2 February 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 27 January 2005
Resolved
Repair or replace anchor light prior to carrying passengers for hire.
Action required: 705 - Other - as specified
Resolved 2 February 2005
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 27 January 2005
Resolved
Make repairs to port aft cleat.
Action required: 705 - Other - as specified
Due 27 February 2005
Resolved 2 February 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 27 January 2005
Resolved
Replace expired eye wash in way of First Aid Kit.
Action required: 705 - Other - as specified
Due 27 February 2005
Resolved 2 February 2005
Documentation › Markings/Placards
Issued 24 September 2003
Resolved
Properly mark the vessel's hull in accordance with 46CFR 67.123. Letters shall be no less than 4 inches in height. To be completed prior to carrying passengers. LEGACY COMPONENT DESC: Hull Markings
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 October 2003
Resolution: Inspector witnessed proper hull markings in accordance with 46 CFR 67.123.
Operations/Management › Passenger Operations › Safety Orientation
Issued 24 September 2003
Resolved
Create passenger safety orientation announcement that includes the requirements of 46 CFR 185.506.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 October 2003
Resolution: A passenger safety orientation announcement was created by the owner/operator and posted at the operating station for future reference.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 September 2003
Resolved
Provide first aid kit that includes the items required by 46 CFR 160.041.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 October 2003
Resolution: Owner / Operator purchased pre-made First Aid Kit that is designed and constructed in accordance with 46 CFR 160.041.
Engineering › Fuel Oil Service System › Valve
Issued 24 September 2003
Resolved
Prove proper operation of fuel shut-off valves.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 October 2003
Resolution: Fuel shutoff valve pulls were re-engineered to facilitate proper closure of the same.
Lifesaving › Lifebuoys
Issued 24 September 2003
Resolved
Repair or replace vessel's ring life buoy in way of the wasted grab line. LEGACY COMPONENT DESC: Grab line
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 October 2003
Resolution: Owner/operator replaced the Ring Buoy with new.
Documentation › Manuals/Policy Documentation
Issued 15 May 2002
Resolved
Post PFD donning placard and include all items in 46 CFR 185.25-1 in safety orientation. LEGACY COMPONENT DESC: Emergency Instructions
Condition: Unknown
Due 17 June 2002
Resolved 12 March 2003
Resolution: Item cleared administratively. Owner opted to remove vessel from certification.
Documentation › Certificates/Documents
Issued 15 May 2002
Resolved
Post stability letter. LEGACY COMPONENT DESC: Stability Letter
Condition: Unknown
Due 17 June 2002
Resolved 12 March 2003
Resolution: Item cleared administratively. Owner opted to remove vessel from certification.
Lifesaving › Lifebuoys
Issued 15 May 2002
Resolved
Provide and install a proper bracket for the waterlight so that the light is arranged to float free. LEGACY COMPONENT DESC: Self-igniting Lights
Condition: Improper Installation
Due 17 June 2002
Resolved 12 March 2003
Resolution: Item cleared administratively. Owner opted to remove vessel from certification.
Electrical › Electrical Distribution System (service)
Issued 15 May 2002
Resolved
Provide electrical bonds to comman ground for fuel tank in accordance with 46 CFR 182.440. LEGACY COMPONENT DESC: Grounding Conductor
Condition: Improper Installation
Due 17 June 2002
Resolved 12 March 2003
Resolution: Item cleared administratively. Owner opted to remove vessel from certification.
Engineering › Fuel Oil Storage/Transfer System
Issued 15 May 2002
Resolved
Install double hose clamps on each end of flexible hose for vessel's fuel line if new hose fittings are not of the manufactured type. LEGACY COMPONENT DESC: Hose
Condition: Improper Installation
Due 17 June 2002
Resolved 30 July 2002
Resolution: Corrected.
Pollution Prevention/Response › Prevention Equipment
Issued 15 May 2002
Resolved
Permanently repair/renew flushing valve for marine head to prevent raw sewage discharge from MSD into head compartment prior to carrying passengers.. LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Condition: Improper/Lack of Maintenance
Due 17 June 2002
Resolved 12 March 2003
Resolution: Item cleared administratively. Owner opted to remove vessel from certification.
Engineering › Non-conventional Propulsion/Steering
Issued 15 May 2002
Resolved
Permanently repair leaking hydraulic line in vessel's steering system prior to operating.
Condition: Unknown
Due 17 June 2002
Resolved 30 July 2002
Resolution: Corrected.
Navigation › Piloting/Steering
Issued 15 May 2002
Resolved
Provide required publications. CG Light List, Tidal and current tables, up to date charts, Navigation Rules and U. S. Coast Pilot. LEGACY COMPONENT DESC: Marine Charts
Condition: Unknown
Due 17 June 2002
Resolved 12 March 2003
Resolution: Item cleared administratively. Owner opted to remove vessel from certification.
Operations/Management › Drug and Alcohol Testing
Issued 14 May 2002
Resolved
Audit of Marine Employer's Drug Testing program revealed the program is not compliant with DOT/CG regulations and lacked means of identifying an approved collections site, provisions for random tests, an Employee's Assistance program, etc...
Due 14 June 2002
Resolved 12 March 2003
Resolution: Item cleared administratively. Owner opted to remove vessel from certification.
Operations/Management
Issued 14 May 2002
Resolved
Conduct a credit dry-dock to the satisfaction of an attending Coast Guard Marine Inspector.
Due 17 June 2002
Resolved 30 July 2002
Resolution: Completed credit dry-dock.
Lifesaving › Lifebuoys
Issued 14 May 2002
Resolved
Install retro reflective tape on life ring buoy as required by subchapter Q.
Condition: Improper Installation
Due 17 June 2002
Resolved 12 March 2003
Resolution: Item cleared administratively. Owner opted to remove vessel from certification.
Engineering › Fuel Oil Storage/Transfer System
Issued 14 May 2002
Resolved
Replace worn fuel hoses with hoses of an approved type for vessel's service. LEGACY COMPONENT DESC: Hose
Condition: Improper Installation
Due 17 June 2002
Resolved 30 July 2002
Resolution: Corrected.
Electrical › Electrical Distribution System (service)
Issued 14 May 2002
Resolved
Remove dead-end wires in way of vessel's fuel filters. LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Due 17 June 2002
Resolved 12 March 2003
Resolution: Item cleared administratively. Owner opted to remove vessel from certification.
Lifesaving
Issued 24 June 1997
Resolved
Affix retro reflective tape on life ring buoy as required._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 July 1997
Resolved 29 July 1997
Navigation
Issued 24 June 1997
Resolved
Provide required pubs._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 July 1997
Resolved 29 July 1997
Documentation
Issued 24 June 1997
Resolved
Provide proof of current drug testing program for all crew members._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 July 1997
Resolved 29 July 1997
Documentation
Issued 24 June 1997
Resolved
Provide a vessel log book as required._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 July 1997
Resolved 29 July 1997
Navigation
Issued 24 June 1997
Resolved
Repair anchor light._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 July 1997
Resolved 29 July 1997
Fire Fighting
Issued 24 June 1997
Resolved
Provide a suction hose for the hand fire/bilge pump._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 July 1997
Resolved 29 July 1997
Lifesaving
Issued 27 January 1995
Resolved
Install ladder access to Buoyant Apparatus or remount to provide easy access. Also, stencil Buoyant Apparatus in 1 1/2" letters and numbers withvessel name and number of persons float is designed for.
Condition: Unknown
Due 27 January 1995
Resolved 27 January 1995
Lifesaving
Issued 27 January 1995
Resolved
Install lifejacket placard and include all items in 46 CFR 185.25-1 in yoursafety orientation.
Condition: Unknown
Due 27 January 1995
Resolved 27 January 1995
Construction/Loadline
Issued 27 January 1995
Resolved
Replace starboard aft cleat._x001C_ (broken)
Condition: Unknown
Due 27 January 1995
Resolved 27 January 1995
Navigation
Issued 27 January 1995
Resolved
Prior to operation of vessel obtain a chart of this area.
Condition: Unknown
Due 1 February 1995
Resolved 1 February 1995
Engineering
Issued 27 January 1995
Resolved
Replace plastic fuel caps with metal ones. Also, install fuel shut off cables on fuel valves after replacing short hose length between suction elbow and valve.
Condition: Unknown
Due 27 January 1995
Resolved 27 January 1995
Documentation
Issued 27 January 1995
Resolved
Provide evidence of personal radio license for master of vessel.
Condition: Unknown
Due 27 January 1995
Resolved 27 January 1995
Lifesaving
Issued 8 March 1994
Resolved
Provide lifefloat or buoyant apparatus of at least 15 person capacity priorto carrying passengers.
Condition: Unknown
Due 17 March 1994
Resolved 17 March 1994