Records from 1993 to 2000. Most recent: inspection, 31 May 2000.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 14
31 May 2000
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 278459
24 May 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 428923
27 April 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 428095
6 May 1998
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 415644
21 April 1998
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 415099
20 December 1997
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 411166
23 June 1997
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 404986
11 June 1997
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 404600
30 April 1997
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 403199
10 May 1994
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 676691
28 April 1994
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 9630
7 December 1993
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 540519
21 September 1993
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 361512
16 September 1993
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 360957
Electrical › Lighting (service) › Lighting Fixture
Issued 31 May 2000
Resolved
Required to fix or replace broken or missing light fixture covers and toilet seats in the cabin and hospital spaces.
Condition: Unknown
Due 1 August 2000
Resolved 7 October 2004
Resolution: 07OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 31 May 2000
Resolved
Required to have on board U.S. Coast Pilot #5 and Inland Rules of the Road.
Condition: Unknown
Due 1 August 2000
Resolved 7 October 2004
Resolution: 07OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Construction/Loadline
Issued 27 April 1999
Resolved
PROVIDE CLASS SURVEYOR REPORT ATTESTING TO THE PROPER OPERATION OF THE AUTOMATIC 15 PPM BILGE SEPERATOR SYSTEM ALARM. PROVIDE REPORT TO THE NEAREST COAST GUARD MARINE SAFETY OFFICE PRIOR TO ENTERING U.S. WATERS.
Condition: Unknown
Due 28 May 1999
Resolved 28 May 1999
Navigation
Issued 21 April 1998
Resolved
PROVIDE TIDAL CURRENT TABLES ONBOARD IAW 33 CFR 164.33(a)(3)(ii)._x001C_ CORRECTION REQUIRED BEFORE NEXT US VOYAGE.
Condition: Unknown
Due 6 May 1998
Resolved 6 May 1998
Fire Fighting
Issued 21 April 1998
Resolved
PACKING GLAND FOR PRIMARY FIRE PUMP WHERE LEAKING ON PRIMARY GENERATOR TO BE TIGHTENED/REPLACED IAW SOLAS 74, CH II-2, REG 4. CORRECTION IS REQUIRED PRIOR TO NEXT US VOYAGE.
Condition: Unknown
Due 6 May 1998
Resolved 6 May 1998
Lifesaving
Issued 21 April 1998
Resolved
REPAIR INOPERABLE LIGHT IN EMERGENCY FIRE PUMP SPACE IAW ILO-147. CORRECTION REQUIRED PRIOR TO NEXT US VOYAGE.
Condition: Unknown
Due 6 May 1998
Resolved 6 May 1998
Electrical
Issued 21 April 1998
Resolved
INSTALL EXPLOSION PROOF FIXTURES IN PAINT LOCKER IAW SOLAS 74,CH II, REG. 10. CORRECTION REQUIRED PRIOR TO NEXT US VOYAGE.
Condition: Unknown
Due 6 May 1998
Resolved 6 May 1998
Navigation
Issued 21 April 1998
Resolved
VESSELS ECHO DEPTH SOUNDER REQUIRED BY 33 CFR 164.35 (h) WAS INOPERABLE. CORRECTION REQUIRED PRIOR TO NEXT US VOYAGE.
Condition: Unknown
Due 6 May 1998
Resolved 6 May 1998
Engineering
Issued 30 April 1997
Resolved
Containment drains are not mechanical closure. Provide mechanical closuresfor all containment drains prior to transferring in U.S. waters_x001C_
Condition: Unknown
Due 8 May 1997
Resolved 8 May 1997
Accommodation/Occupational Safety
Issued 30 April 1997
Resolved
Port side Galley Door not weathertight. Repair and make weathertight.
Condition: Unknown
Due 25 June 1997
Resolved 23 June 1997
Fire Fighting
Issued 30 April 1997
Resolved
Fire drill unsat, conduct satisfactory fire drill in the presence of a Marine Inspector.
Condition: Unknown
Due 8 May 1997
Resolved 8 May 1997
Fire Fighting
Issued 30 April 1997
Resolved
Exhaust leak on Emergency Fire Pump. Repair.
Condition: Unknown
Due 8 May 1997
Resolved 8 May 1997
Engineering
Issued 30 April 1997
Resolved
Softpatch on saltwater cooling pump stbd side. Repasir and provide Class report.
Condition: Unknown
Due 8 May 1997
Resolved 8 May 1997
Fire Fighting
Issued 30 April 1997
Resolved
Fireplug upper deck port side not on fire plan. Mark on fire plan and provide Class report.
Condition: Unknown
Due 8 May 1997
Resolved 8 May 1997
Accommodation/Occupational Safety
Issued 30 April 1997
Resolved
Vent for Stbd side Aft inoperable. Repair
Condition: Unknown
Due 8 May 1997
Resolved 8 May 1997
Lifesaving
Issued 30 April 1997
Resolved
Port lifeboat upper rudder bracket broken. Renew/repair as original.
Condition: Unknown
Due 8 May 1997
Resolved 8 May 1997
Lifesaving
Issued 30 April 1997
Resolved
Port & Stbd bridgewing life ring lines attaching smokelight are wasted. Renew/replace.
Condition: Unknown
Due 8 May 1997
Resolved 8 May 1997
Navigation
Issued 30 April 1997
Resolved
Gryo and repeaters on bridge readings differ as much as 140 degrees readings from repeater in steering compartment. Adjust repeaters to read thge same as main gryo.
Condition: Unknown
Due 8 May 1997
Resolved 8 May 1997
Documentation
Issued 16 September 1993
Resolved
While conducting an annual examination it was noted than the vessel's oil transfer procedures were incomplete.
Condition: Unknown
Due 12 October 1993
Resolved 12 October 1993