Records from 2016 to 2025. Most recent: inspection, 16 October 2025.
Documentation record
Registered dimensions (L × B × D)50.0 ft × 14.6 ft × 6.0 ft
Registered tonnagegross 29 / net 23
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderUNIFLITE · BELLINGHAM, WA, UNITED STATES · built 1979
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portNEWCASTLE, ME
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 6 September 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it29 - Simplified, Gross Ton
23 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 15
16 October 2025
Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8254402
19 November 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8038016
16 October 2024
Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8019894
26 July 2023
COI Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7753019
8 November 2022
Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7591608
17 October 2022
Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7579077
15 October 2021
Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7396600
8 October 2020
Drydock Exam · Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7074523
17 October 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6836823
22 October 2018
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6566576
11 July 2018
COI Inspection · Administrative Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6475460
6 October 2017
Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6294946
21 November 2016
Drydock Exam · Administrative Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6037788
11 October 2016
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6004263
6 April 2016
Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5848369
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 16 October 2024
Resolved
COD has expired. Provide current COD.
Due 30 October 2024
Resolved 19 November 2024
Resolution: COD provided.
09 - Working and Living Conditions › 092 - Working Conditions › Other (working space ILO)
Issued 16 October 2024
Resolved
First Aid contents long expired. Refresh/replace as needed.
Due 30 October 2024
Resolved 19 November 2024
Resolution: First aid kit replaced.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 October 2024
Resolved
Mast head light burnt out. Repair/replace as needed.
Due 30 October 2024
Resolved 19 November 2024
Resolution: Bulb replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 October 2024
Resolved
Ring buoy line (60') needs permanently attached to solid part of ring buoy.
Due 30 October 2024
Resolved 19 November 2024
Resolution: Line correctly routed.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 16 October 2024
Resolved
Lifejacket instruction placard is faded. Replace with new placard.
Due 30 October 2024
Resolved 19 November 2024
Resolution: Placard replaced.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 26 July 2023
Resolved
Needs DSC capable radio.
Action required: 705 - Other - as specified
Due 24 August 2023
Resolved 17 August 2023
Resolution: Installed DSC capable radio
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 July 2023
Resolved
Needs certified individual to conduct maintenance.
Action required: 705 - Other - as specified
Due 5 August 2023
Resolved 17 August 2023
Resolution: Had FE's professionally inspected
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 November 2022
Resolved
MI conducted DDX and identified that the cutlass brgs needed to be renewed due to over 50% wastage. O/O indicated that there was a misalignment between the shaft and reduction gear putting a small load on the engine when at lower rpm's. Inspected shaft IVO water groove brgs and determined that it should be removed and inspected as a worklist item prior to taking passengers.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 19 January 2023
Resolved 24 March 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 October 2022
Resolved
Generator fuel filter needs to be plugged
Action required: 705 - Other - as specified
Due 17 October 2022
Resolved 27 July 2023
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 17 October 2022
Resolved
Radio needs DSC function to be programmed.
Action required: 705 - Other - as specified
Due 17 October 2022
Resolved 3 August 2023
Resolution: Carried over to new inspection.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 October 2022
Resolved
Unused emacerator pump needs to have the dead-ended wires removed.
Action required: 705 - Other - as specified
Due 17 October 2022
Resolved 27 July 2023
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 October 2020
Resolved
Label fuel shut off.
Due 22 October 2020
Resolved 28 October 2020
Resolution: Fuel shut off labelled.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 8 October 2020
Resolved
Provide servicing document for Fire boy and system testing.
Due 22 October 2020
Resolved 28 October 2020
Resolution: Owner provided documentation of testing.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 October 2020
Resolved
Replace expired items in first aid kit.
Due 22 October 2020
Resolved 21 October 2020
Resolution: First aid kit supplied
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 8 October 2020
Resolved
Provide two portable lights.
Due 22 October 2020
Resolved 28 October 2020
Resolution: Portable lights provided.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 October 2020
Resolved
Refresh vessel name on life ring.
Due 22 October 2020
Resolved 28 October 2020
Resolution: Name refreshed on life buoy
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 October 2019
Resolved
Loose Dead end wiring found in fore peak.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 June 2020
Resolution: Def cleared to the satisfactionof the MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 October 2019
Resolved
Provide proper USCG approved fuel filter with appropriate flame bowl as necessary.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 June 2020
Resolution: Def cleared to the satisfaction of the MI
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 October 2019
Resolved
Provide documentation for required servicing of fire extinguishers and fixed fire fighting system.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 June 2020
Resolution: Def cleared to the satisfactionof the MI.