Records from 1993 to 2001. Most recent: inspection, 12 January 2001.
Engineering
Issued 12 January 2001
No resolution recorded
CROP AND REPLACE EPOXY REPAIRED PIPE SECTION ON THE # 13 LOWER DECK ENGINE ROOM STBD SIDE GENERATOR SEAWATER COOLING LINE, AS ORIGINAL TO THE SATISFACTION OF ATTENDING CLASS SURVEYOR._x001C_ SOLAS 74 II-1/C REG 26/3.6_x001C_
Condition: Unknown
Due 15 March 2001 — due date passed with no resolution recorded
Lifesaving
Issued 12 January 2001
No resolution recorded
REPAIR LIGHT FIXTURES IN PIPE TUNNEL (KEEL DUCTS) AS ORIGINAL TO THE SATISFACTION OF C.G. INSPECTOR._x001C_ SOLAS 60/I-REG 10
Condition: Unknown
Due 15 February 2001 — due date passed with no resolution recorded
Electrical
Issued 3 November 1995
Resolved
PROVE OPERATION OF EMERGENCY GENERATOR UNDER A LOADED CONDITION.
Condition: Unknown
Due 14 November 1995
Resolved 14 November 1995
Navigation
Issued 3 November 1995
Resolved
PROVIDE UP TO DATE CHARTS AND NAUTICAL PUBLICATIONS TO THE LATEST NOTICE TOMARINERS.
Condition: Unknown
Due 14 November 1995
Resolved 14 November 1995
Electrical
Issued 3 November 1995
Resolved
RELAMP ALL LIGHT FIXTURES THROUGHT THE VESSEL TO PROVIDE ADEQUATE LIGHTING_x001C_FOR SAFE PASSAGE THROUGHOUT VESSEL.
Condition: Unknown
Due 14 November 1995
Resolved 14 November 1995
Documentation
Issued 3 November 1995
Resolved
PROVIDE AND POST "DISCHARGE OF OIL PROHIBITED" IN A CONSPICUOUS PLACE IN_x001C_ EACH MACHINERY SPACE OR AT THE BILGE AND BALLAST PUMP CONTROL STATION IN_x001C_ ACCORDANCE WITH 33CFR 155.450. THE PLACARD MUST BE PRINTED IN THE_x001C_ LANGUAGE UNDERSTOOD BY THE CREW.
Condition: Unknown
Due 24 December 1997
Resolved 24 December 1997
Fire Fighting
Issued 3 November 1995
Resolved
PROVIDE ON BOARD VESSEL INSTRUCTIONS FOR MAINTENANCE AND OPERATION OF ALL INSTALLATIONS/EQUIPMENT FOR FIGHTING AND CONTAINMENT OF FIRE. SOLAS 74 AMENDED II-2/20
Condition: Unknown
Due 24 December 1997
Resolved 24 December 1997
Electrical
Issued 3 November 1995
Resolved
REPAIR/RENEW LEAKING HEAD GASKET TO EMERGENCY GENERATOR INTERNAL_x001C_ COMBUSTION ENGINE.
Condition: Unknown
Due 14 November 1995
Resolved 14 November 1995
Lifesaving
Issued 3 November 1995
Resolved
PROVIDE ON BOARD TRAINING MANUAL FOR LIFESAVING APPLIANCES. SOLAS 74 AMENDED III/18.2/51
Condition: Unknown
Due 24 December 1997
Resolved 24 December 1997
Lifesaving
Issued 3 November 1995
Resolved
PROVIDE ONBOARD INSTRUCTIONS FOR ONBOARD MAINTENANCE OF LIFESAVING APPLIANCES. SOLAS 74 AMENDED III/19.3/52
Condition: Unknown
Due 24 December 1997
Resolved 24 December 1997
Lifesaving
Issued 3 November 1995
Resolved
PROVIDE UPDATED MUSTER LIST & EMERGENCY INSTRUCTIONS EXHIBITED IN CONSPICUOUS PLACES THROUGHOUT THE VESSSEL INCLUDING THE NAVIGATING BRIDGE, ENGINE ROOM AND CREW ACCOMMODATION SPACES IAW SOLAS 74 (AMENDED) III/8.
Condition: Unknown
Due 24 December 1997
Resolved 24 December 1997
Lifesaving
Issued 3 November 1995
Resolved
PROVIDE 406 MHZ SATELLITE EMERGENCY POSITIONING INDICATING RADIO BEACON (EPIRB)... SOLAS 74 AMENDED IV/7.1.6
Condition: Unknown
Due 14 November 1995
Resolved 14 November 1995
Fire Fighting
Issued 3 November 1995
Resolved
RENEW/REPAIR INOPERATIVE FIRE HYDRANT VALVE LOCATED PORT SIDE LOWER ENGINE ROOM. SOLAS 74 AMENDED II-2/21
Condition: Unknown
Due 14 November 1995
Resolved 14 November 1995
Lifesaving
Issued 3 November 1995
Resolved
RENEW ALL DEFECTIVE RING BUOYS. PROVIDE 12 RING LIFEBUOYS ON STATION IN ACCORDANCE WITH SHIPS SAFETY EQUIPMENT CERTIFICATE FORM E IN SERVICEABLE CONDITION AND AVAILABLE FOR IMMEDIATE USE. SOLAS 74 AMENDED III/19.2
Condition: Unknown
Due 14 November 1995
Resolved 14 November 1995
Lifesaving
Issued 3 November 1995
Resolved
RENEW DEFECTIVE WATERLIGHTS TO RING LIFEBUOYS. PROVIDE SIX WATERLIGHTS ATTACHED TO RING LIFEBUOYS IN ACCORDANCE WITH SHIPS SAFETY EQUIPMENT CERTIFICATE FORM E THAT ARE IN SERVICABLE CONDITION AND AVAILABLE FOR IMMEDIATE USE. SOLAS 74 AMENDED III/19.2
Condition: Unknown
Due 14 November 1995
Resolved 14 November 1995
Fire Fighting
Issued 3 November 1995
Resolved
RENEW DEFECTIVE FIRE HOSES THROUGHOUT VESSEL. NOTED OVER 90% OF THOSE CHECKED WERE HOLED. ALL HOSES THROUGHOUT SHIP SHALL BE RENEWED AND/OR PRESSURE TESTED IN THE PRESENCE OF THE ATTENDING U.S. COAST GUARD MARINE INSPECTOR.SOLAS 74 AMENDED II-2/21
Condition: Unknown
Due 14 November 1995
Resolved 14 November 1995
Documentation
Issued 3 November 1995
Resolved
PROVIDE ONBOARD OIL TRANSFER PROCEDURES. 33 C.F.R. 155.750
Condition: Unknown
Due 14 November 1995
Resolved 14 November 1995
Engineering
Issued 3 November 1995
Resolved
REPAIR AND PROVE OPERATION OF OILY-WATER SEPERATING EQUIPMENT W/ALARMS AND MONITORING DEVICES.
Condition: Unknown
Due 14 November 1995
Resolved 14 November 1995
Lifesaving
Issued 3 November 1995
Resolved
VERIFY PRESENCE AND CONDITION OF REQUIRED LIFEBOAT EQUIPMENT. ENSURE EXPIRATION DATE ON PROVISIONS AND ALL OTHER ITEMS ARE NOT EXCEEDED. PROVIDETHE MARINE INSPECTOR WITH A CHECKLIST OF ITEMS REQUIRED BY CLASS FOR EXAMINATION
Condition: Unknown
Due 14 November 1995
Resolved 14 November 1995
Construction/Loadline
Issued 3 November 1995
Resolved
REMOVE OIL AND OIL RESIDUE FROM ENGINE ROOM BILGES AND AROUND PURIFIERS.
Condition: Unknown
Due 14 November 1995
Resolved 14 November 1995
Fire Fighting
Issued 3 November 1995
Resolved
REPAIR/RENEW/SERVICE ALL PORTABLE/SEMI-PORTABLE FIRE EXTINGUISHING APPLIANCES THROUGHOUT THE VESSEL. NOTED SEVERAL UNUSABLE EXTINGUISHERS THROUGHOUT THE VESSEL. SOLAS 74 AMENDED II-2/6
Condition: Unknown
Due 14 November 1995
Resolved 14 November 1995
Lifesaving
Issued 3 November 1995
Resolved
PROVIDE POSTERS OR SIGNS ON OR IN THE VICINITY OF SURVIVAL CRAFT AND THEIR LAUNCHING CONTROLS THAT: ILLUSTRATE THE PURPOSE OF THE CONTROLS 7 THE PROCEDURE FOR OPERATING THE APPLIANCE; USE SYMBOLS IAW IMO RESOLUTION A.603. SEE SOLAS 74 (AMENDED) III/9
Condition: Unknown
Due 24 December 1997
Resolved 24 December 1997
Fire Fighting
Issued 3 November 1995
Resolved
PROVIDE OPERATION OF FIRE DETECTION SYSTEMS TO THE SATISFACTION OF THE_x001C_ SATISFACTION OF THE ATTENDING U.S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 14 November 1995
Resolved 14 November 1995
Fire Fighting
Issued 3 November 1995
Resolved
PROVE OPERATION OF REMOTE SHUTDOWN FOR POWER VENTILATION CAPABLE OF BEING_x001C_ SHUTDOWN FROM OUTSIDE VENTILATION SPACE.
Condition: Unknown
Due 14 November 1995
Resolved 14 November 1995
Unknown
Issued 3 November 1995
Resolved
PROVIDE FUEL OIL DISCHARGE CONTAINMENT FOR PORT AND STARBOARD GAS OIL_x001C_ BUNKERING STATION LOCATED ON MAIN DECK IN ACCORDANCE WITH 33CFR 155.320
Condition: Unknown
Due 24 December 1997
Resolved 24 December 1997
Lifesaving
Issued 3 November 1995
Resolved
PROVIDE TWO OPERATIONAL RADAR TRANSPONDERS WHICH CLEARLY INDICATE ON THE_x001C_ EXTERIOR OF THE TRANSPONDERS: (a) BRIEF OPERATING INSTURCTIONS. _x001C_ (b) EXPRIATION DATE FOR THE PRIMARY BATTERY USED. SOLAS 74(AMENDED)III/6._x001C_2.2
Condition: Unknown
Due 24 December 1997
Resolved 24 December 1997
Navigation
Issued 3 November 1995
Resolved
PROVIDE THREE 2 WAY VHF RADIOTELEPHONE APPARATUS IN ACCORDANCE WITH SOLAS_x001C_ 74(AMENDED)III/6.2.1
Condition: Unknown
Due 14 November 1995
Resolved 14 November 1995
Lifesaving
Issued 3 November 1995
Resolved
PROVIDE EVIDENCE OF RENEWAL OF DAVIT FALLS WITHIN THE PAST 5 YEARS AND/OR_x001C_ END FOR ENDED WITHIN THE PAST 30 MONTHS IN ACCORDANCE WITH _x001C_ SOLAS 74(AMENDED) III/19.4
Condition: Unknown
Due 14 November 1995
Resolved 14 November 1995
Electrical
Issued 3 November 1995
Resolved
PROVIDE OPERATION OF EMERGENCY LIGHTING THROUGHOUT THE VESSEL INCLUDING_x001C_ EMBARKATION AREA. SOLAS 60 III/19
Condition: Unknown
Due 24 December 1997
Resolved 24 December 1997
Construction/Loadline
Issued 3 November 1995
Resolved
RENEW AS ORIGNIAL DETERIORATED BULKHEAD LOCATED ON THE MAIN DECK PORT SIDE_x001C_IN WAY OF ENTRANCE TO FWD BOSIN LOCKER.
Condition: Unknown
Due 14 November 1995
Resolved 14 November 1995
Fire Fighting
Issued 3 November 1995
Resolved
REMOVE DEBRIS IN FRONT OF FIXED CO2 CONTROL PANEL, LOCATED ON MAIN DECK._x001C_ MAKE CONTROL PANEL AVAILABLE FOR IMMEDIATE USE._x001C_
Condition: Unknown
Due 14 November 1995
Resolved 14 November 1995
Fire Fighting
Issued 3 November 1995
Resolved
REMOVE EXCESS WATER FROM PUMP ROOM, CONTAINING THE EMERGENCY FIRE PUMP.
Condition: Unknown
Due 14 November 1995
Resolved 14 November 1995
Electrical
Issued 3 November 1995
Resolved
PROPERLY SECURE BATTERIES LOCATED IN THE ELECTRICAL STORE ROOM IN WAY OF_x001C_ STBD LIFE BOATS.
Condition: Unknown
Due 14 November 1995
Resolved 14 November 1995
Lifesaving
Issued 3 November 1995
Resolved
RENEW DEFECTIVE/DETRIORATED LIFEJACKETS AND PROVIDE CORRECT AMOUNT OF SERVICEABLE LIFEJACKETS IN ACCORDANCE WITH FLAG ADMINISTRATION ISSUED SAFETY EQUIPMENT CERTIFICATE FORM E.
Condition: Unknown
Due 14 November 1995
Resolved 14 November 1995
Lifesaving
Issued 3 November 1995
Resolved
SUCCESSFULY CONDUCT TO THE SATISFACTION OF THE ATTENDING COAST GUARD MARINEINSPECTOR AN ABANDON SHIP AND FIRE DRILL.
Condition: Unknown
Due 14 November 1995
Resolved 14 November 1995
Lifesaving
Issued 3 November 1995
Resolved
INSTALL ADEQUATE RETRO-REFLECTIVE TAPE ON ALL LIFEBOATS IN ACCORDANCE WITH_x001C_IMO RESOLUTION A.658(16)
Condition: Unknown
Due 14 November 1995
Resolved 14 November 1995
Engineering
Issued 3 November 1995
Resolved
PROVIDE REQUIRED BOLTS AND GASKET FOR STANDARD DISCHARGE CONNECTION LOCATEDON STARBOARD SIDE OF VESSEL, IN ACCORDANCE WITH MARPOL 73/78 ANNEX V/4 AND 33CFR 151.63
Condition: Unknown
Due 14 November 1995
Resolved 14 November 1995
Fire Fighting
Issued 3 November 1995
Resolved
SERVICE FIXED FIRE SUPPRESSION SYSTEM FOR FWD PAINT LOCKER BY PROFESSIONAL_x001C_FIRE SERVICING COMPANY. SOLAS 74(AMENDED)II-2/21
Condition: Unknown
Due 14 November 1995
Resolved 14 November 1995
Fire Fighting
Issued 3 November 1995
Resolved
PROVIDE EVIDENCE OF LAST SERVICING OF FIXED FIRE SUPPRISSION SYSTEM TO _x001C_ CARGO SPACES OR HAVE UNIT SERVICED BY PROFESSIONAL SERVICING COMPANY._x001C_ SOLAS 60 II/65(f)
Condition: Unknown
Due 14 November 1995
Resolved 14 November 1995
Engineering
Issued 3 November 1995
Resolved
X
Condition: Unknown
Due 14 November 1995
Resolved 14 November 1995