← All vessels
SEDA
SEDA is a 1984 freight ship. The Coast Guard has recorded 25 inspections since 1993, most recently in December 2010, along with 17 deficiencies and 3 operational controls.
Records from 1993 to 2010. Most recent: operational control imposed, 22 December 2010.
- Built
- 1984
- Last inspected
- 22 December 2010
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 17 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8521816 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V3NA5
387146
Flag
BELIZE
—
Maury page id
psix-387146
Inspections, by type
The 25 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.
Documentation record
Tonnage as PSIX records it12383 - Convention (Subpart B), Gross Ton
4658 - Convention (Subpart B), Net Ton
11848 - Dead Weight, Ton
19111 - Displacement, Ton
4658 - Convention (Subpart B), Net Ton
11848 - Dead Weight, Ton
19111 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 25
22 December 2010
Ballast Water Examination · PI Safety Exam · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3914547
21 December 2010
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3914561
16 December 2009
PII Safety Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3651214
29 September 2008
PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3329316
7 August 2008
Type not recorded
No type recorded · USCGC STINGRAY (WPB 87305) · USCG Heartland District (CGD-H) · Activity 3299479
3 January 2008
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3119753
12 March 2007
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2886488
8 March 2007
Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2884164
6 September 2006
ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2770467
3 March 2006
NPV Safety Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2596988
8 August 2005
ISPS II Exam · Re-Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2455957
24 March 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2323929
3 February 2005
PII Safety Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2285757
30 June 2004
Random ISPS/MTSA/PSC
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2116880
12 January 2004
Annual Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1982456
16 May 2002
Security Inspection · Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1617725
1 October 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 294095
30 April 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 289480
23 November 1999
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 434904
12 January 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 411707
22 October 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 449587
11 October 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 396353
1 June 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 681338
23 May 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 505623
12 April 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 357638
Deficiency record · 17
Engineering › Diesel Engine (propulsion-direct drive) › Governor
Issued 22 December 2010
Resolved
1410 - Propulsion main engine - Pilot reported ships main engine was too slow in responding to commands from the engine order telegraph by 10 seconds, according to testimony from vessel crew - SOLAS 2004 Cons. Ed Ch I/II
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 22 December 2010
Resolved
1575 - Echo Sounder - The depth is off by approximately 17 feet and the device is not recording the history - SOLAS 2004 V/12(d)
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 22 December 2010
Resolved
1030 - Steering Gear Alarm - When steering gear pumps are shut down, no audible and visual alarms activated on the bridge - SOLAS 2004 Cons Ed. Ch I/II
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 22 December 2010
Resolved
1581 - Rudder Angle Indicator - The rudder angle indicator repeater on the bridge does not go from 35 to 30 degrees. However, both the helm and the rudder angle in the steering gear room do go from 30 to 35 degrees - SOLAS 2004 Cons Ed. Ch I/ll
Accommodation/Occupational Safety › Ventilation › General
Issued 22 December 2010
Resolved
0999 - Other (safety in general) - Plastic wrap has been tightly wound around the air vent in the vicinity of the turbocharger on the main engine, stopping a leak or holding the vent in place - SOLAS 2004 Cons Ed. Ch I/II
Construction/Loadline › Penetrations › Weld
Issued 22 December 2010
Resolved
1499 - Other (Prop & Aux Machinery) - The crew has modified the ship exhaust system by adding an extra pump outside the smoke stack that pumps out the exhaust in order to assist blowers - SOLAS 2004 Cons Ed. Ch I/II
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 8 March 2007
Resolved
Vessel had only one line throwing apparatus. Vessel is required to have four line throwing apparatus before departure. (17c) SOLAS Chapter 3, Regulation 18.
Operations/Management › Drills/Instruction › Fire
Issued 8 March 2007
Resolved
Ran fire drill in galley. The following deficiencies were noted: (1) Space Isolation: Doors were not closed in immediate area of fire drill, only closing of doors came from automatic release from bridge (which only closed 14 doors throughout the vessel), (2) Inadequate fire hose length: fireteam used hose from messdeck vice thru aft galley door, and (3) Fireman's outfit not properly donned.
Deck/Cargo
Issued 30 April 2001
Resolved
PROVIDE MECHANICAL CLOSURE DEVICES FOR ALL SMALL DISCHARGE CONTAINMENTS ON MAIN DECK. 33 CFR 155.320
Fire Fighting
Issued 30 April 2001
Resolved
REPAIR/REPLACE #2 FIRE PUMP HOUSING FOR SHAFT PACKING (BROKEN BOLT HOLDER).PROVIDE CLASS REPORT ATTESTING TO REPAIR NO LATER THAN 30MAY01._x001C_ SOLAS 74 (AMENDED)II- 2/21
Construction/Loadline
Issued 30 April 2001
Resolved
MAKE PERMANENT REPAIR TO RAW WATER COOLING PIPE BETWEEN PUMP AND MAIN ENGINE. NOTED LARGE SOFT PATCH. SOLAS 74/II-1._x001C_
Deck/Cargo
Issued 30 April 2001
Resolved
REPLACE MAIN GENERATOR VENT OIL CONTAINMENT. NOTED OIL ON LIFEBOAT DECK BEHIND ENGINE ROOM VENTILATION FM EXHAUST.
Fire Fighting
Issued 30 April 2001
Resolved
INSTALL SELF-CLOSING MECHANISM ON ALL DOORS FOR EMERGENCY ESCAPE FROM ENGINE ROOM. NOTED SEVERAL "ESCAPE/FIRE CLASS A" DOORS SWINGING FREELY._x001C_ SOLAS 74(AMENDED)II-2/II_x001C_ CORRECT PRIOR TO DEPARTURE FROM THE PORT OF PASCAGOULA, MISSISSIPPI.
Navigation
Issued 30 April 2001
Resolved
REPLACE OUTDATED PASCAGOULA CHART W/ LATEST EDITION. CORRECT PRIOR TO DEPARTURE FROM THE PORT OF PASCAGOULA, MISSISSIPPI._x001C_ 33 CFR 164.33
Fire Fighting
Issued 30 April 2001
Resolved
ADJUST SELF CLOSING DEVICE TO MAIN ENGINE ROOM DOOR. (THIS DOOR IS PRIMARY FIRE DOOR). REPAIR PRIOR TO DEPARTURE FROM PORT OF PASCAGOULA. MISSISSIPPI.SOLAS 74 (AMENDED II-2/II_x001C_ _x001C_
Electrical
Issued 23 November 1999
Resolved
LIGHT COVERS FOR ALL GALLEY LIGHTS MISSING. REPLACE COVERS AS PER SOLAS 74UNAMENDED II-1 REG 27(a).
Accommodation/Occupational Safety
Issued 11 October 1996
Resolved
TOILET FOR SICK BAY INOPERABLE, NOT IN COMPLIANCE WITH ILO 147.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National