All automatic, remotely controlled, or monitored vital systems addressed in 46 CFR Part 62 must have
approved Design Verification and Periodic Safety test procedures (PSTP) available onboard for testing prior to
issuance of the initial COI. Vessel using revision "H" of PSTPs, which has not been approved; revision"H" reflects the most current equipment, however the latest approve revision onboard was PSTP revision "E".
ACP Single Supplement, 3.1.14
74SOLAS II-1/31
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 8 October 2025
No resolution recorded
All exposed metal parts of electrical machines or equipment which are not intended to be "live" but are liable to become "live" under fault conditions, shall be earthed (grounded); and all electrical apparatus shall be so constructed and so installed that danger of injury in ordinary handling shall not exist. Multiple motor controllers and electric motors identified with missing or broken ground wire in engine room.
74SOLAS II-I/27(a)(i)(1)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 8 October 2025
No resolution recorded
Wiring shall be supported in such a manner as to avoid chafing or other injury. Shaft seal oil level sensor wiring exposed and improper termination.
74SOLAS II-1/27(a)(2)(vi)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 8 October 2025
No resolution recorded
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. When in ROS status, vessel has minimum crew and maneuverability. Prior to activation, vessel must conduct fire and abandon ship drills, lower lifeboats into the water, and put all safety gear at location to the satisfaction of the attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 8 October 2025
No resolution recorded
Before the ship leaves port, all life-saving appliances
shall be in working order and ready for immediate use.
When in ROS status, vessel has minimum crew and
maneuverability. Prior to activation, vessel must
conduct fire and abandon ship drills, lower lifeboats
into the water, and put all safety gear at location to
the satisfaction of the attending Marine Inspector.
SOLAS 74 III/26(a)(ii)
Action required: 701 - Prior to carriage of passengers/cargo
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 10 December 2024
Resolved
Fire fighting systems and appliances shall be kept in good working order. Marine inspector observed a ruptured pipe in the firemain line IVO frame 21 of the embarkation deck ramp.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 December 2024
Resolution: Recieved Class report that damaged fire main piping was cropped, renewed and hydrostatically tested, opp test sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 10 December 2024
Resolved
The International Load Line Certificate shall not be delivered to the ship until the officer or surveyor acting under the provisions of article 13 of the present convention has certified that the marks are correctly and permanently indicated on the ship's sides. Marine inspector observed missing authority mark while walking along side vessel
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 11 December 2024
Resolution: Recieved Class report attesting to the markings on the Plimsoll were restored, sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 19 October 2022
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Crew was unable to start the port life boat.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 November 2022
Resolved 1 November 2022
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 19 October 2022
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. All four line throwing appliances on the vessel are expired.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 2 November 2022
Resolved 1 November 2022
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 19 October 2022
Resolved
Emergency lighting at every boat station on deck and
oversides, in all alleyways, stairways and exits, in the
main machinery space and main generation space, on the
navigating bridge and in the chart room shall be
adequate for a period of 6 hours. Vessel's emergency
lighting did not function in various locations
throughout the vessel to include: officers galley,
escape trunk outside of engine room and all lifesaving
appliance embarkation areas.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 November 2022
Resolved 1 November 2022
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 October 2022
Resolved
The Administration shall be satisfied that adequate arrangements are in place to ensure that the performance of equipment in chapter V is maintained. Various navigation light bulbs are burned out with no spares
available on-board the vessel.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 November 2022
Resolved 1 November 2022
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 19 October 2022
Resolved
Each operation described in paragraph 2 of this regulation shall be fully recorded without delay in the Oil Record Book Part I. Each completed operation shall be signed by the officer or officer in charge of the operations concerned and each completed page shall be signed by the master of ship. Vessels ORB has 6 pages that were not being signed by the master of ship.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 November 2022
Resolved 1 November 2022
01 - Certificates & Documentation › 013 - Documents › Garbage record book
Issued 19 October 2022
Resolved
Each completed page of the Garbage Record Book shall be signed by the master of ship. Vessel’s Garbage Record Book most current completed page was not signed.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 November 2022
Resolved 1 November 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 October 2022
Resolved
All electrical apparatus shall be so constructed and so installed that the danger of injury in ordinary handling shall not exist. Vessel has exposed wires on the #2 Piston C/W Pump.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2022
Resolved 1 November 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Equipment (including exemption)
Issued 19 October 2022
Resolved
A certificate called a Cargo Ship Safety Certificate may be issued after an initial or renewal survey to a cargo ship that complies with the relevant requirements. Vessel's Form E is showing an incorrect number of liferafts listed. Prior to sailing foreign vessel must have a correct CSSE Certificate on board.
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 November 2022
Resolved 1 November 2022
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 19 October 2022
Resolved
Structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in these divisions shall be kept in good order so as to ensure their required performance if a fire occurs. In both the LP CO2 Room and the emergency generator room the vessel is utilizing two different penetration materials for a single cable run.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 November 2022
Resolved 1 November 2022
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 19 October 2022
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. When in ROS status, vessel has minimum crew and maneuverability. Prior to activation, vessel must conduct fire and abandon ship drills, lower lifeboats into the water, and put all safety gear at location to the satisfaction of the attending Marine Inspector.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 November 2022
Resolved 19 May 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 19 October 2022
Resolved
The company should identify equipment the operational failure of which may result in hazardous situations. The SMS should provide for specific measures aimed at promoting the reliability of such equipment. Vessel’s SMS system requires the calibration of critical gauges. This calibration is currently overdue by 90 days and while conducting a machinery walk through noted a broken gauge on the No 1 Ballast Pump for reading PSIG.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 November 2022
Resolved 1 November 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 21 October 2021
Resolved
All exposed metal parts of electrical machines or equipment which are not intended to be “live” but are liable to become “live” under fault conditions, shall be earthed (grounded); and all electrical apparatus shall be so constructed and so installed that the danger of injury in ordinary handling shall not exist. Vessel is showing a ground on the 440VAC switchboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 December 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 October 2021
Resolved
Accumulator batteries shall be suitably housed, and compartments used primarily for their accommodation shall be properly constructed and efficiently ventilated. Vessel’s battery box for the GMDSS equipment is rusted out with various holes on the bottom edges.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 December 2021
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 21 October 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations and to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel has two portable accommodation modules (PAM). Both have multiple holes in modules completely through to the deck. Furniture is not secured within and one head is out of commission. PAM’s can not be occupied by personnel until repaired.
Action required: 705 - Other - as specified
Resolved 3 March 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 21 October 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations and to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Knife-edge on window leading into the Technician’s Room is so severely deteriorated that no seal is formed.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 December 2021
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 21 October 2021
Resolved
Every crew member shall participate in at least one abandon ship drill and one fire drill every month. When a new crew is engaged, these drills shall be held before sailing. When vessel becomes activated must conduct drills to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Resolved 21 July 2022
Resolution: Conducted fire and abandonship drills.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 21 October 2021
Resolved
All lifeboats shall be monthly turned out from their stowed position, without any persons on board if weather and sea conditions so allow. Vessel is moored stbd-side-to and unable to lower stbd lifeboat. Prior to activation vessel must exercise lifeboats to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Resolved 22 July 2022
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 21 October 2021
Resolved
Fire extinguishing appliances in new and existing cargo ships shall be kept in good order and available for immediate use at all times during the voyage. Vessel’s fire pump would not immediately turn on upon testing. After various attempts vessel was able to start and test fire pump.
Action required: 10 - Deficiency Rectified
Resolved 21 October 2021
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 19 October 2021
Resolved
Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. Vessel is unable to make any announcements to the entire ship due to a non functioning public address system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2022
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 16 March 2021
Resolved
The general principle governing the provision of lifeboats, life rafts and buoyant apparatus in a ship to which this chapter applies is that they shall be readily available in case of emergency. Vessel's STBD lifeboat propeller shaft packing was found sticking and binding, resulting in engine stall. Vessel's crew provided water flow lubrication through the cutlass bearing, causing lifeboat to operate satisfactory, as designed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 March 2021
Resolved 16 March 2021
Resolution: Vessel's engineers provided water to the shaft packing, effectively lubricating the system, resolving the issue to the attending marine inspector's satisfaction.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 24 September 2020
Resolved
The purpose of this Chapter is to require the fullest practicable degree of fire protection, fire detection and fire extinction in ships. The following basic principles underlie the Regulations in this Chapter and are embodied in the Regulations as appropriate, having regard to the type of ships and the potential fire hazard involved: containment and extinction of any fire in the space of origin.
Fuel leaks discovered on #3 Ship Service Diesel Generator, while in operation, on external piping for #2 & #3 cylinders.
74 SOLAS (Unamend) II-2/2(e)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2020
Resolved 2 December 2020
Resolution: Deficiency rectified to the satisfaction of the attending ABS surveyor.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 September 2020
Resolved
All exposed metal parts of electrical machines components which are not intended to be "live" but are liable to become "live" under fault conditions, shall be earthed (grounded); and all electrical apparatus shall be so constructed and so installed that danger of injury in ordinary handling shall not exist.
Main switchboard 220V L3 phase ground detection system not functioning to manufacturer's specifications.
74 SOLAS (Unamend) II-1/27(a)(i)(1)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 October 2020
Resolved 2 December 2020
Resolution: Deficiency rectified to the satisfaction of the attending ABS surveyor.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 24 September 2020
Resolved
Every oil fuel pipe from a storage, settling or daily service tank situated above the double bottom shall be fitted with a cock or valve capable of being closed from outside the space concerned in the event of a fire arising in the space in which such tanks are situated.
Incinerator Main Diesel Oil (MDO) tank remote operated valve failed to close upon remote activation.
74 SOLAS (Unamend) II-2/54(c)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2020
Resolved 2 December 2020
Resolution: Deficiency rectified to the satisfaction of the attending ABS surveyor.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 24 September 2020
Resolved
Plans and alterations shall be kept up to date, any alterations being recorded thereon as soon as practicable.
Structural fire protection, on bulkheads in machinery space supply ventilation rooms, is severely dilapidated and/or missing.
74 SOLAS (Uamaned)II-2/4
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 October 2020
Resolved 2 December 2020
Resolution: Deficiency accepted as a condition of class.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 September 2020
Resolved
All electrical apparatus shall be so constructed and so installed that danger of injury in ordinary and so installed that danger of injury in ordinary handling shall not exist.
SSDG #3 wires exposed near DG HT JW pumps.
74 SOLAS (Unamend) II-1/27(a)(i)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2020
Resolved 2 December 2020
Resolution: Deficiency rectified to the satisfaction of the attending ABS surveyor.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 September 2020
Resolved
All electrical apparatus shall be so constructed and so installed that danger of injury in ordinary and so installed that danger of injury in ordinary handling shall not exist.
Junction box for #2 ballast pump is cracked, having an exposed portion.
74 SOLAS (Unamend) II-1/27(a)(i)(1)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 October 2020
Resolved 2 December 2020
Resolution: Deficiency rectified to the satisfaction of the attending ABS surveyor.
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 24 September 2020
Resolved
After any survey of the ship under Regulations 7, 8, 9 or 10 of this Chapter has been completed, no change shall be made in the structural arrangements, machinery equipment, etc. covered by the survey without the sanction of the Administration.
Visual alarm light positioned in the lower fwd level of of the machinery space is out.
Push button for fire alarm in fire control room is missing cover glass.
Low hydraulic oil light indicator at local steering control station is out.
74 SOLAS (Unamend) I/11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2020
Resolved 2 December 2020
Resolution: Deficiency rectified to the satisfaction of the attending ABS surveyor.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 24 September 2020
Resolved
The company and the ship shall comply with the requirements of the International Safety Management Code. For the purpose of this regulation, the requirements of the Code shall be treated as mandatory.
The company shall establish procedures to ensure that the ship is maintained in conformity with the provisions of the company. In meeting these requirements, the company shall ensure that: inspections are held at appropriate intervals, any non-conformity is reported, with its possible cause, if known, appropriate corrective action is taken, records of these activities are maintained.
PSTP's state that the SSDG's are to shutdown upon the jacket water reaching 92.3 degrees Celsius. While using dry-well to heat JW shutdown RTD's, shutdown failed to activate for all 3 SSDG's.
74 SOLAS (14) IX/3.1
ISM Code Part A/10.1 + 10.2
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 October 2020
Resolved 2 December 2020
Resolution: Deficiency rectified to the satisfaction of the attending ABS surveyor.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 24 September 2020
Resolved
Every crew member shall participate in at least one abandon ship and one fire drill every month and a drill shall take place within 24 hours for a 25% crew change.
Conduct abandon ship and fire drill in the presence of CG MI's.
74 SOLAS (14) III/19.3.2
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 October 2021
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 18 September 2019
Resolved
PA system inoperable.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 18 September 2019
Resolved 23 September 2019
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 18 September 2019
Resolved
#11 and #14 cargo fan pneumatic rams for dmapner opening are inoperable.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 18 September 2019
Resolved 16 June 2020
Resolution: ABS provided class report (Class No: 1231.0) attesting to the proper repair and operation of the #11 and #14 cargo fan dampers. Cleared.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 18 September 2019
Resolved
Noted an L2 ground fault on the emergency diesel generator switchboard
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 18 September 2019
Resolved 23 September 2019
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 18 September 2019
Resolved
A-60 insulation at frame 42 starboard engine room separated from frame.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 18 September 2019
Resolved 23 September 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 18 September 2019
Resolved
#3 port double bottom man hole cover not watertight.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 18 September 2019
Resolved 23 September 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 18 September 2019
Resolved
Main engine exhaust gas temperature sensor inoperable. Alarm was faded alarm list.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 18 September 2019
Resolved 23 September 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 18 September 2019
Resolved
#1 HFO purifier leaking and lagging soaked through.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 18 September 2019
Resolved 23 September 2019
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 18 September 2019
Resolved
Diesel oil purifier has a leak at the flanged connection.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 18 September 2019
Resolved 23 September 2019
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 18 September 2019
Resolved
#2 Ships service generator has a fuel leak.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 18 September 2019
Resolved 23 September 2019
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 18 September 2019
Resolved
Port steering gear has a phase failure alarm and is unable to clear.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 18 September 2019
Resolved 23 September 2019
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 18 September 2019
Resolved
The A-60 door leading to the Tech Room will not close and latch.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 18 September 2019
Resolved 23 September 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 18 September 2019
Resolved
The window knife edge for the Tech Room is wasted through.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 September 2019
Resolved 23 September 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 September 2019
Resolved
Noted portable fire extinguishers placed in the wrong brackets, brackets too large for the installed extinguishers.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 18 September 2019
Resolved 23 September 2019
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 18 September 2019
Resolved
Fire alarm panel on the bridge has 8 zones and only 6 are labeled.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 18 September 2019
Resolved 23 September 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 18 September 2019
Resolved
Retroreflective material on both lifeboats requires replacement.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 September 2019
10 - Safety of Navigation › N/A - No Subsystem › Signalling lamp
Issued 18 September 2019
Resolved
There is no power to the bridge wings for the signaling lamp. The lamp can only be utilized on the battery pack.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 18 September 2019
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 18 September 2019
Resolved
Float light batteries expired. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 18 September 2019
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 27 November 2018
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. De-lamination and water saturation of the fiberglass on sections of the floors of both lifeboats has occurred.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 December 2018
Resolution: Attended vsl - confirmed tech report and visually inspected repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 November 2018
Resolved
At each inspection for certification and periodic inspection, the marine inspector shall conduct such tests and inspections of the main propulsion and auxiliary machinery and its associated equipment, including the fluid control systems, as he feels necessary to check safe operations. Technical publications for the completion of machinery testing were not available onboard the vessel, and such testing could not be completed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 December 2018
Resolution: Reviewed tech pubs & conducted required testing IAW same.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 October 2018
Resolved
Complete ABS listed conditions of class # 1015, 1010, 1007, 1004, 1003 prior to continuation of CG inspection.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 10 December 2018
Resolved 27 November 2018
Resolution: Class report onboard vessel confirms rectification of above items.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 29 October 2018
Resolved
Fire extinguishing appliances in new and existing passenger ships and cargo ships shall be kept in good order and available for immediate use at all times during the voyage. Bridge fire alarm panel is showing an unexplained "trouble" alarm in Zone 9.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 December 2018
Resolution: Attended vsl - Reviewed Tech report & confirmed trouble alarm no longer active.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 29 October 2018
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: Structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in these divisions. A-60 fire door for the emergency generator space on the starboard side did not close and latch properly.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 December 2018
Resolution: Checked fire doors and confirmed appropriate closure & maintenance of A60 Boundary.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 29 October 2018
Resolved
Every company should develop, implement and maintain a safety management system which includes the following functional requirements: Instructions and procedures to ensure safe operation of ships and protection of the environment in compliance with relevant international and flag state legislation. Mandate external ISM audit based on findings from deficiencies # 1 (lifesaving maintenance program) and 2 (lack of technical publications) listed above.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 December 2018
Resolution: Confirmed ISM Audit completion by ABS. Recv'd copy of report & reviewed items included in audit.
Engineering › Freshwater System (jacketwater cooling) › Pump
Issued 21 March 2018
Resolved
Install machinery guards on high water jacket pump
Condition: Improper/Lack of Maintenance
Due 21 April 2018
Resolved 18 April 2018
Resolution: Machinery guards were installed on the high jacket water pump to the satisfaction of the attending surveyor.
Engineering › Freshwater System (jacketwater cooling) › Pump
Issued 21 March 2018
Resolved
3 pieces of machinery located at frame 41 needing machinery guards
Condition: Improper/Lack of Maintenance
Due 21 April 2018
Resolved 18 April 2018
Resolution: The three pieces of machinery were fitted with machinery guards to the satisfaction of the attending surveyor.
Electrical › Lighting (service) › Lighting Branch Circuit
Issued 21 March 2018
Resolved
Replace all loose wiring located in Emergency generator room and engine room
Condition: Improper/Lack of Maintenance
Due 21 April 2018
Resolved 18 April 2018
Resolution: All loose wiring was repaired or replaced to the satisfaction of the attending surveyor.
Engineering › Lubricating Oil Service System › Purifier
Issued 21 March 2018
Resolved
Oil purifier room needs to be clean of excessive amounts of build up oil on bulkheads and in the bilge; All 835's were given to be done within 30 days after issuing date.
Condition: Invalid
Due 21 April 2018
Resolved 23 April 2018
Resolution: The oil purifier room bulkhead and bilge was cleaned to the satisfaction of the attending surveyor.
Construction/Loadline › Penetrations › Bottom Plug
Issued 21 March 2018
Resolved
Vessel failed to maintain Class A fire protection by way of deck penetration in the radio room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 April 2018
Resolved 18 April 2018
Resolution: The penetatrions were sealed to the satisfaction of the attending surveryor.
Lifesaving › Inflatable Buoyant Apparatus › Serviceable
Issued 21 March 2018
Resolved
Vessel failed to maintain life saving appliances in good working order, i.e. life buoy makings and retro. Water lights not working.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 April 2018
Resolved 18 April 2018
Resolution: The life buoys, light, and life jacket retro were found to be in good working order by the attending surveyor.
Construction/Loadline › Structures › Door
Issued 21 March 2018
Resolved
Vessel failed to maintain the required Class A fire boundary on door D-50-A
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 April 2018
Resolved 18 April 2018
Resolution: The boundary door was adjusted to the satisfaction of the attending surveyor.
Deck/Cargo › Mooring/Anchoring › Brake
Issued 21 March 2018
Resolved
Vessel brake pads on mooring winch found near failure, pads should be replaced prior to vessel movement.
Due 22 April 2018
Resolved 29 September 2018
Resolution: ABS has taken appropiate actions to rectify damaged pads. Pads have been ordered and installation arrangements have been made.
Operations/Management › Drills/Instruction › Not Conducted
Issued 31 July 2017
Resolved
Conduct fire, abandon ship and security drills to the satisfaction of attending Marine Inspector. 46 CFR 199.180
Action required: 17 - Rectify deficiencies prior to departure
Due 31 July 2017
Resolved 7 August 2017
Resolution: Witnessed satifactory fire & boat drills.
Lifesaving › Inflatable Liferafts › Carriage Requirement
Issued 31 July 2017
Resolved
Lifesaving appliances were on board but not on station. All lifesaving appliances must be placed on station to the satisfaction of attending MI.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 July 2017
Resolved 7 August 2017
Resolution: Conducted inservice inspection, equipment on station.