Records from 2016 to 2026. Most recent: inspection, 25 June 2026.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 25 June 2026
Resolved
Every inflatable liferaft shall be serviced at intervals not exceeding 12 months and at an approved servicing station which is competent to service them, maintains proper servicing facilities, and uses only properly trained personnel. Liferaft servicing was due 3 JUN 2026. Ship has ordered servicing prior to commencing inspection. 74 SOLAS (24)III / 20.8
Action required: 17 - Rectify deficiencies prior to departure
Due 25 June 2026
Resolved 6 July 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 25 June 2026
Resolved
All life-saving appliances and arrangements shall comply with the applicable requirements of the Code. Except as otherwise stated, the normal equipment of every life boat shall consist of a food ration totaling not less than 10,000 kJ for each person the lifeboat is permitted to accommodate, kept in airtight packaging and be stored in a watertight container. The vessel currently has 38 of the required 42 rations. Vessel restricted to carriage of no more than 38 persons till rectified.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 July 2026
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 25 June 2026
Resolved
A fixed fire-extinguishing system required by paragraph 5 below may be any of the following systems: a fixed gas fire-extinguishing system complying with the provisions of the fire safety systems code. At each location there shall be clear instructions relating to the operation of the system having regard to the safety of personnel. The instructions for the EDG's fixed CO2 system had instructions for local and remote operation posted at both locations, which could lead to potential confusion in the event of an emergency.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 July 2026
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 25 June 2026
Resolved
Means shall be provided to close all openings which may admit air to or allow gas toescape from a protected space. Above and aft of the door for the EDG there is a small hole in the bulkhead. 74 SOLAS (97)
II-2/5.1.4
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 July 2026
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 25 June 2026
Resolved
In a ship for which oil fuel is used the arrangements for the storage, distribution and use of the oil fuel shall be such as to ensure the safety of the ship and persons on board. Fuel leak detected at he fuel strainer supplying generators 1,2, and 3. Excessive oil observed in the lifeboat engine space. 74 SOLAS (97) II-2/15.2
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 July 2026
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 25 June 2026
Resolved
Fire integrity of bulkheads and decks mentioned elsewhere in this part, the minimum fire integrity of bulkheads and decks shall be as prescribed in table 58.1 and 58.2. The A-60 ceiling panel forward of frame 100 on the port side hull was found hanging. Aft of this location there are approximately 10 panels that have minor damage/wear.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 July 2026
01 - Certificates & Documentation › 013 - Documents › Unattended Machinery Spaces (UMS) Evidence
Issued 25 June 2026
Resolved
Measures shall be taken to the satisfaction of the administration to ensure that the equipment is functioning in a reliable manner and the satisfactory arrangements are made for regular inspections and routine tests to ensure continuous reliable operation. PSTP is inaccurate for low level alarm on steering, unable to perform PSTP for power failure on steering pumps. 74 SOLAS (04)
II-1/46.1
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 July 2026
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 15 January 2026
Resolved
Any ship of 10,000 gross tonnage and above shall be fitted with oil filtering equipment complying with paragraph 7 of this regulation. Vessel's OWS was not operational. Vessel's crew believes this is related to the sample line solenoid.
MARPOL 73/78 1/14.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 January 2026
Resolved 28 January 2026
Resolution: Crew replaced solenoid. ABS attested to proper operation of OWS.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 January 2026
Resolved
Cables and wiring shall be supported in such a manner as to avoid chafing or other damage. In the vessel's steering gear a new outlet was found installed the wire for which was supported by plastic wire ties.
74 SOLAS (04) II-1/45.5.5
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 January 2026
Resolved 28 January 2026
Resolution: ABS attested to proper installation of wires.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 15 January 2026
Resolved
The official number of the vessel, preceded by the abbreviation •NO.• must be marked in block-type Arabic numerals not less than three inches in height on some clearly visible interior structural part of the hull. The number must be permanently affixed to the vessel so that alteration, removal, or replacement would be obvious. Official number is not permanently affixed.
46 CFR 67.121
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 February 2026
Resolved 28 January 2026
Resolution: Permanently affixed.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 7 February 2025
No resolution recorded
Every crew member shall participate in at least one abandon ship drill and one fire drill every month; when a new crew is engaged, these drills shall be held before sailing. Upon activation, conduct fire and abandon ship drills to the satisfaction of the attending Marine Inspector. This will include observing the the rescue
boat and free-fall lifeboat being maneuvered in the water, unless this has been carried out with the CG in attendance within the past 3 months. 74 SOLAS III/19.3.2
Action required: 17 - Rectify deficiencies prior to departure
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 7 February 2025
No resolution recorded
No vessel may be operated unless it has in its service and on board, the complement required by the certificate of inspection. Upon activation, provide MMC for FOS crew to the satisfaction of the attending Marine Inspector. 46 CFR 15.515
Action required: 17 - Rectify deficiencies prior to departure
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 2 December 2024
Resolved
Where "A" Class divisions are pierced for the passage of electric cables, pipes,trunks, ducts, etc., for girders, beams or other structures, arrangements shall be made to ensure that the fire resistance is not impaired, subject to the provisions of paragraph (g) of this regulation. The penetration located under the main panel in the fire control station was not properly arranged to ensure fire resistance. 74 SOLAS II-2/23(a)
Condition: Improper/Lack of Maintenance
Due 3 January 2025
Resolved 13 January 2025
Resolution: Received confirmation from class that they had verified closure of penetration with finding 1413.
01 - Certificates & Documentation › 011 - Ships Certificates › Safety Management Certificate (SMC/ ISM)
Issued 3 July 2024
Resolved
74 SOLAS IX 6.2
A ship required to hold a certificate issued pursuant to the provisions of regulation 4.3 shall be subject to control in accordance with the provisions of regulation XI/4. For this purpose such certificate shall be treated as a certificate issued under regulation I/12 or I/13. Vessel’s Safety Management Certificate has been revoked following ISM audit.
Action required: 30 - Ship detained
Resolved 28 August 2024
Resolution: Vessel completed a ISM-SMC Interim audit and new operator was issued an interim ISM-SMC certificate.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 3 July 2024
Resolved
74 SOLAS 2020 II-2 14.2.1
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: fire detection and fire alarm systems. It was found that vessel’s found that cargo deck’s fire detection system was inoperable. During inspection it was discovered that the cargo fire detection system has not been working since 16 MAY 2024. The ship must maintain an hourly round among the cargo decks until the system is repaired.
Action required: 30 - Ship detained
Resolved 26 September 2024
Resolution: Recieved class report verifying that the vessel's cargo fire detection system is operational.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 25 June 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel reported leak in their fire main investigate source of leak and test entire system to the satisfaction of the attending marine inspector. 74 SOLAS I/11a
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 September 2024
Resolution: Found to be an open valve verfied by class.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 25 June 2024
Resolved
The means of control of any fixed gas fire-extinguishing system shall be readily accessible, simple to operate and shall be grouped together in as few locations as possible at positions not likely to be cut off by a fire in a protected space. At each location there shall be clear instructions relating to the operation of the system having regard to the safety of personnel. The instructions posted for the low pressure CO2 system do not provide clear instructions for the operation of the system. In addition the master valve was found locked crew stated the only person with the key is the chief engineer. 74 SOLAS II-2 4.1.1.1.1
FSS Chp 5.2.1.3.3 17ac
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 September 2024
Resolution: Verfied to be corrected by class.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 24 June 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to sea without danger to the ship or persons on board. The vessel reported a breach in the vessel's hull with water ingression into the vessel. The following requirements are to be followed and rectified to the satisfaction of the attending marine inspector and the vessel's RO:
1. Identify and control the source of the leak.
2. Secure the space where the leak is occurring.
3. Make hourly rounds of the space to ensure water ingress does not increase beyond what is currently occurring.
4. Staff the vessel with adequate personnel to dewater the vessel in the case of an emergency. 74 SOLAS I/11a 17ac
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 September 2024
Resolution: Verfied to not be a crack but a leak from a pipe above the spot in the hull.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 19 June 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board.
Vessel reported a leak in their ballast piping system.
Temporary patch/plug has been put in place.
SOLAS I/11(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 November 2024
Resolution: IT WAS REPLACED, the elbow from the No.1 Port Ballast Pump. A new elbow was installed and the pump was operated with new piping in place.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 16 April 2024
Resolved
Each berthing area shall be equipped with information regarding reporting of sexual assault and sexual harassment that meets 46 USC 11101. In each washing space there shall be information regarding procedures...
The required information is not posted in all necessary spaces. See CVC Policy Letter 23-04 for amplifying information.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 November 2024
Resolution: ABS verified postage of SASH signage. Finding number 1382.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 16 April 2024
Resolved
Information regarding all access and use of the vessel's master key shall be recorded in a log book. Crew not included on the list described in subsection (a)(2) shall not have access to or use of the master key unless in an emergency and shall immediately notify the master and owner of the vessel following use of such key.
A master key control log is not being maintained up to
date onboard. Additionally, the current CGS SMS policy
regarding master key control authorizes various shoreside personnel and other crew members temporary use of the master key to perform work related functions and completion of an assigned task, respectively. This is not permitted under the statute. See CVC Policy Letter 23-06 for amplifying information.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 September 2024
Resolution: This deficiency was issued to the previous operator and does not apply to the current operator.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 31 January 2024
Resolved
The Company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements that may be established by the Company.
There are technical and operational deficiencies noted in the original inspection report/835V (dated 1/31/24, pgs. 1-20) that indicate a serious failure / lack of effectiveness of implementation of the safety management system.
An external SMC audit, at least equivalent in scope to a renewal audit, is required to be carried out by the RO (ABS) prior to the vessel's departure from port.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2024
Resolved 30 April 2024
Resolution: Additional SMC audit was carried out on 3/12/24, resulting in 1 MNC and 4 NCs. Received confirmation from ABS on 4/30 that the MNC has been downgraded and a short-term SMC issued until 7/15/24.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 31 January 2024
Resolved
Before the ship leaves port, all life-saving equipment shall be in working order and ready for immediate use.
Primary steering for free fall lifeboat found to be inoperable during in-water test.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2024
Resolved 29 April 2024
Resolution: Received ABS report no. 6243011, which in finding no. 1303 reports that the primary steering for the FFLB was proven fully operational to the satisfaction of the attending ABS surveyor.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 31 January 2024
Resolved
Any ship of >10,000 gross tons shall be fitted with oil filtering equipment, approved by the Administration, with alarm arrangements, etc.
The full and proper functionality of the OWS/OCM could not be demonstrated, as the ppm could not be reduced below 35-40 when tested.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2024
Resolved 28 June 2024
Resolution: Proper operation was proven during ABS attendance and recorded in report #6421334.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 31 January 2024
Resolved
Every oil fuel pipe, which, if damaged, would allow oil to escape from a storage, settling, or daily service tank shall be fitted with a valve capable of being closed from a safe position outside the space concerned in the event of a fire occurring in the space.
Proper operation of the quick closing valves for the oil system could not be demonstrated at this time. Additionally, the PSTP for testing of these valves is inaccurate when compared with the actual onboard arrangement. Prove proper operation of all quick closing valves and revise the PSTP to reflect the onboard arrangements.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2024
Resolved 29 April 2024
Resolution: Received ABS report no. 6243011, which in finding no. 1306 reports that quick-closing valves are proven operational. Revisions to PSTP still pend and are covered under finding no. 1293.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 31 January 2024
Resolved
The ISM Company should ensure that inspections are held at appropriate intervals and appropriate corrective action is taken.
Vibration analysis and thermography was carried out in September 2023 as part of post dry-dock sea trial, with multiple serious/unsatisfactory findings noted. Additionally, a large percentage of equipment included on the report was listed as either OOC or not run, and therefore readings not taken. All items noted in need of repair to be addressed, and readings to be taken for missing items, with rectification of any new/additional findings. Provide the results of updated/new report to both ABS and CG.
*UPDATE*
29 May 2024
Appropriate measure have been taken to correct outstanding items for vibration/themograpy. Once vessel activates, contractor will attend to reconduct surveys and verify corrective action. Changed from 17 to 705.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2024
Resolved 5 November 2024
Resolution: IT WAS RE-INSPECTED, the fast rescue boat davit was repaired and operation was demonstrated
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 31 January 2024
Resolved
An efficient bilge piping pumping system shall be provided.
The proper operation of the emergency bilge suction could not be demonstrated. No venturi effect/suction noted with the eductor running.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2024
Resolved 29 April 2024
Resolution: Received ABS report no. 6243011, which in finding no. 1307 reports that the emergency bilge system was proven fully operational to the satisfactoin of the attending ABS surveyor.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 31 January 2024
Resolved
The ISM Company should ensure that inspections are held at appropriate intervals and appropriate corrective action is taken.
The latest lube oil analysis report from Tribologik noted multiple critical conditions. Additionally, most all sampling history does not indicate a sample within the past 6 months. Appropriate action to be taken for all noted items, and oil analysis taken for missing/overdue items, with rectification of any new/additional findings. Provide the results to both ABS and CG.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2024
Resolved 27 November 2024
Resolution: ABS reported finding 1352 closed.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 31 January 2024
Resolved
Fire-fighting systems and appliances shall be kept in good working order.
Multiple fire station hydrant valves found leaking by when the fire main was energized, including in shaft tunnel, steering flat (station #96), engine room (station #93), fire station 53, and fire station 26. These fire hydrant valves to be repaired or replaced, and ABS to subsequently carry out complete walkdown of fire main while energized to confirm all hydrant valves are in proper working order.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2024
Resolved 29 May 2024
Resolution: Items have been repaired and verified by the attending ABS surveyor.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 January 2024
Resolved
Relief valves for air receivers marked as last tested in 2018, for auxiliary boiler in 2018, and for exhaust gas boiler in 2017 (all >5 years ago). Associated work order in NSE listed as overdue by >200 days. All of these relief valves shall be tested, and proper relieving setpoints verified, to the satisfaction of the attending ABS surveyor.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2024
Resolved 28 June 2024
Resolution: The noted relief valves were sent ashore to be serviced. These valves were tested and proven fully operational and properly marked to the satisfaction of the attending surveyor prior to re-installation onboard. Report number 6421334
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 31 January 2024
Resolved
The vessel does not currently hold a valid IOPP certificate. ABS removed the IOPP and issued a SOF due to onboard engine room piping arrangements not complying with the MARPOL I/12.3 requirements (see ABS finding 1205). However, holding an IOPP is mandatory for vessels enrolled in ACP and to comply with 33 CFR requirements. Make necessary modifications to piping arrangements onboard to comply with MARPOL I/12.3 amendments and regain IOPP certificate.
*Update*
29 May 2024
Vessel has contracted company to complete repairs and make piping modification bilge piping. Changed from 17 to 705. Once repairs are made then deficiency will be closed.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2024
Resolved 27 November 2024
Resolution: IT WAS REPAIRED, the IOPP piping bilge and sludge arrangement was submitted to ABS and a review letter was issued. Piping was installed and tested to comply with approved drawings. SOVC IOPP and Supplement A were issue
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 31 January 2024
Resolved
A minimum of 2 two-way portable radiotelephone apparatus for each fire party for fire-fighters communication shall be carried on board, of the explosion-proof or intrinsically safe type.
No firefighter radios that are properly rated for use in hazardous area currently provided onboard.
*UPDATE*
05 June 2024
Vessel has procured radios for use in hazardous area. Changed from 17 to 705. Will clear once ABS attending surveyor has approved and operationally tested satifactory.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2024
Resolved 23 July 2024
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 31 January 2024
Resolved
Every ship shall be provided with a main steering gear to the satisfaction of the Administration.
There is a steering alarm on the main steering stand on the navigation bridge that cannot be cleared and is of unknown origin/cause.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2024
Resolved 29 April 2024
Resolution: Received ABS report no. 6243011, which in finding no. 1310 reports that the steering system was proven fully operational and free of alarms at this time to the satisfaction of the attending ABS surveyor. Determined to be operator error to not reset alarm.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 31 January 2024
Resolved
Fire protection systems shall be kept in good working order to ensure their required performance if a fire occurs.
The vent damper and cargo hold fan indicator panel on the bridge has multiple indicator lights burnt out, and the low oil level light is constantly illuminated. Replace all burnt out bulbs. Determine and correct cause of low oil level alarm.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2024
Resolved 5 June 2024
Resolution: Item has been corrected and witnessed by attending ABS surveyor.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 31 January 2024
Resolved
The following navigation lights are not properly functioning at this time:
• aft anchor lower on main nav light panel
• aft anchor port lower on main nav light panel
• multiple lights on the 'Christmas tree' panel
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2024
Resolved 29 April 2024
Resolution: Received ABS report no. 6243011, which in finding no. 1311 reports that the noted navigation lights were proven fully operational to the satisfaction of the attending ABS surveyor.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 31 January 2024
Resolved
The protection of openings and penetrations in fire-resisting divisions shall be kept in good order so as to ensure their required performance if a fire occurs.
Multiple cable penetrations found to have missing or improper firestop/sealing, including in the following locations:
• In the cabinets for the newly installed radars at the deck penetration
• Underneath the GMDSS suite and VDR box at the deck penetration
• At the bulkhead above the door going into room 380
• At the bulkhead into room 341 (laundry)
• At the bulkhead into room 430
• At the deck penetration for the fire detection panel in the ballast control room
The above list is not to be interpreted as all-inclusive. A complete survey of penetrations of fire rated boundaries is required to be carried out by ABS or a third party, and any issues corrected. Provide the survey/inspection results to the CG for their review and concurrence.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2024
Resolved 28 June 2024
Resolution: IT WAS VERIFIED, all noted MCTs are packed and sealed. Report # 6421334
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 31 January 2024
Resolved
Mechanical appliances for washing/toilet spaces shall be kept in good working order.
Accommodation exhaust fan for toilets is locked out/tagged out, motor partially disassembled, and belt for fan motor missing.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2024
Resolved 5 June 2024
Resolution: Item was cleared by attending ABS surveyor.
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 31 January 2024
Resolved
Fire Control Plans shall be kept up to date.
Rev G of the Fire Control Plan was found to have multiple inaccuracies. ABS shall carry out full onboard verification of the FCP, revisions to be made and re-approved as necessary.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2024
Resolved 27 November 2024
Resolution: FCP verified by ABS
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 31 January 2024
Resolved
The muster list shall specify substitutes for key persons who may become disabled.
Substitution for key personnel is not listed on the station bill posted on the navigation bridge.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2024
Resolved 29 April 2024
Resolution: Received ABS report no. 6243011, which in finding no. 1346 reports that the ROS station bill was posted. Recommend follow-up at future CG attendance to confirm that posted station bills list substitution for key personnel
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 31 January 2024
Resolved
Fire protection systems shall be kept in good working order to ensure their required performance if a fire occurs.
The vent damper and cargo hold fan indicator panel in the ballast control room has multiple inop indicator
lights. Replace all inop indicator lights.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2024
Resolved 5 June 2024
Resolution: Item has been cleared by attending ABS surveyor.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 31 January 2024
Resolved
Waste receptables shall be constructed of non-combustible material with no openings in the sides or bottom.
Plastic trash cans found in use throughout the accommodation spaces, along with some in the engine room, with various combustible trash inside. Per MSC Circular 1120, plastic waste receptacles are only allowed if used solely for wet waste, glass bottles, and metal cans and are suitably marked.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2024
Resolved 5 June 2024
Resolution: Item has been verified complete by attending ABS surveyor.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 31 January 2024
Resolved
The maintenance hatch going down to the bow thruster room has a gap with light coming through. ABS to confirm watertight or weathertight requirements on LL-11-D, and appropriate repairs to be made as needed.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2024
Resolved 5 June 2024
Resolution: ABS surveyor attested that the hatch was not required to be weathertight on the LL-11-D but should be modified to show some degree of water tightness. Hatch has been repaired and updates to LL-11-D were submitted to ABS engineering for approval.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 31 January 2024
Resolved
Maintenance, testing, and inspection of life-saving appliances shall be carried in a manner having due regard to ensuring reliability of such appliances.
The 3 year pressure testing of the immersion suits was last carried out on 08 January 2021 and is now overdue
(annual testing of several older suits overdue in 1/22).
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2024
Resolved 29 April 2024
Resolution: Received ABS report no. 6243011, which in finding no. 1346 reports that periodical 3rd party testing of the immersion suits was carried out (servicing report dated 15Apr24).
10 - Safety of Navigation › N/A - No Subsystem › Pilot ladders and hoist/pilot transfer arrangements
Issued 31 January 2024
Resolved
Pilot ladder winch reel as currently arranged does not meet the applicable statutory requirements. The pilot ladder is not secured at deck level >915mm horizontally inward from the ship’s side, and weight of pilot ladder can still be partially hanging on the reel. ABS to carry out full evaluation of onboard pilot embarkation arrangements against the applicable requirements. The above-noted and any additional discrepancies identified by ABS to be addressed.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2024
Resolved 25 June 2024
Resolution: Received approved plans from ABS engineering and verified repairs have been made to pilot ladder arrangements.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 31 January 2024
Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard.
The HPU for the cargo vent dampers has multiple leaks with diapers and a bucket arranged to catch leaks. Additionally, the electrical junction box cover is off, with exposed wires.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2024
Resolved 29 April 2024
Resolution: Received ABS report no. 6243011, which in finding no. 1317 reports that the cargo vent HPU was proven free of leakage and junction box cover found installed to the satisfaction of the attending ABS surveyor.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 31 January 2024
Resolved
Before the ship leaves port, all life-saving equipment shall be in working order.
High-pressure hydraulic lines running from the HPU to
the FFLB davit have multiple loose or missing support brackets, causing the lines to vibrate excessively.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2024
Resolved 5 June 2024
Resolution: Attending ABS surveyor attested that corrections have been made.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 31 January 2024
Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard.
In the pipe tunnel, near the split aft of the emergency fire pump room, there is a significant amount of standing hydraulic oil. Identify the source(s) of the leak(s) and clean up the standing oil.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2024
Resolved 26 September 2024
Resolution: Recieved class report stating area cleaned.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 31 January 2024
Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard.
There is pooled hydraulic oil in the bilge in the bow thruster room. Identify the source(s) of the leak(s) and clean up the standing oil.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2024
Resolved 27 November 2024
Resolution: Bow thruster room verified clean, however still identifying source of leak. Additional requirement placed on the vessel by ABS for monitoring.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 31 January 2024
Resolved
The following emergency lights were found inoperable during testing of e-lighting while on EDG power:
• Light at top of stairwell heading down towards galley
• Light in ballast control room near the exterior door
• Light in LPCO2 room near the door
Additionally, there was no e-lighting in the two storage compartments (aft, port side) for the fireman’s outfits on 12 deck.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2024
Resolved 29 April 2024
Resolution: Received ABS report no. 6243011, which in finding no. 1321 reports that all noted emergency lights had their bulbs replaced and were proven fully operational to the satisfaction of the attending ABS surveyor.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 31 January 2024
Resolved
Fire hazards are to be minimized.
Multiple areas of oil-soaked lagging and pipe insulation found in the engine room, purifier room, and provision refrigeration equipment compartment. Any oil-soaked lagging or insulation to be replaced; painting is not permitted.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2024
Resolved 26 September 2024
Resolution: Oil soaked lagging verified to be removed and replaced by class.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Incinerator incl. operations and operating manual
Issued 31 January 2024
Resolved
The incinerator shall be properly and fully decommissioned if no longer in use. At present:
-Containment for incinerator fuel oil tank vent is holed
-Fuel tank appears still partially full, but quick
closing valve is not hooked up. Fuel lines need to be
disconnected and blanked off.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2024
Resolved 5 June 2024
Resolution: Item has been verified complete by attending ABS surveyor.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 31 January 2024
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use.
• On the starboard LPCO2 tank there is visible corrosion on an approximately 1 inch diameter line coming off the inboard end near where the refrigeration coils enter the tank. Provide a report of thickness gauging or other nondestructive testing in order for ABS and CG to assess the condition of this section of piping and suitability for continued service.
• On the small-diameter line leading from the CO2 pilot bottle for the incinerator, there is a section of piping just above the manual release cabinet with visible corrosion. Provide a report of thickness gauging or other nondestructive testing in order for ABS and CG to assess the condition of this section of piping and suitability for continued service.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2024
Resolved 5 November 2024
Resolution: IT WAS RE-INSPECTED, the service supplier report for the LP CO2 system. The piping in question was replaced and radiographic shots were taken to demonstrate pipe thickness for standing piping in question.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 31 January 2024
Resolved
The master, owner, operator, agent or person in charge of any vessel equipped with ballast tanks that operates in the waters of the United States must maintain a ballast water management plan that has been developed specifically for the vessel and that will allow those responsible for the plan’s implementation to understand and follow the vessel’s BWM strategy and comply with the requirements of this subpart.
The vessel’s ballast water management plan available onboard at time of inspection, dated August 2013, is out-of-date / incorrect. Specifically, it states that ballast water exchange is still a permissible ballast water management method for the vessel, but for vessels such as the Cape Washington that are past the implementation schedule in 151.2035, ballast water exchange is no longer a permissible management option. Revise the ballast water management plan to the satisfaction of the CG.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2024
Resolved 5 June 2024
Resolution: Revisions have been completed to meet the requirements of 33 CFR 151.2035.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 31 January 2024
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: structural fire protection.
The following issues with structural fire protection were found during the inspection:
• A section of the SFP has been folded back in the radio room.
• SFP missing on overhead above fire damper access panel R15Q across from the hospital.
• A section of SFP is missing near the door of room 370 (air condition center).
• A section of SFP is missing in the overhead in the passageway near the entrance to room 430 (electrical switchboard room).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2024
Resolved 28 June 2024
Resolution: The missing/damaged areas of structural fire protection were repaired/replaced to the satisfaction of the attending Surveyor. ABS report # 6421334
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 31 January 2024
Resolved
The following fire protection systems shall be kept in good order as to ensure their required performance if a fire occurs: penetrations and openings in fire-resisting divisions.
The following issues with fire dampers were identified:
• The second from port side fire damper for room 218 (rec room) sticks when pulled.
• Hydraulic room oil cooler intake and exhaust vents
have dry-rotted gaskets on the vent dampers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2024
Resolved 5 June 2024
Resolution: Item has been cleared by the attending ABS surveyor.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 31 January 2024
Resolved
Electrical installations shall ensure the safety of crew and ship from electrical hazards.
The following electrical issues were identified during the course of the inspection:
• Backup batteries for the GMDSS suite not properly secured/strapped down.
• An extension cord is plugged into a 220V outlet in the passageway across from room 374, that goes to a step-down transformer to power a route. To be removed or hard-wired.
• Junction box on aft bulkhead of EDG spacing facing the freefall lifeboat is missing its cover and with exposed wires.
• Bonding wires missing on multiple cargo hold fan enclosures on 12 deck.
• The cable/wiring run for the emergency fire pump near the motor itself is not properly supported.
• Port side steering pump controller hanging by wires.
• Sewage tank level junction box missing cover.
• Dead end wiring in the EDG overhead that runs outside the EDG to a junction box that is wide open.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2024
Resolved 5 June 2024
Resolution: Item has been cleared by the attending ABS surveyor.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 31 January 2024
Resolved
For remote hand operation of watertight doors, an audible alarm shall be configured to sound when the door is moving.
The audible alarm for the class 2 watertight door for the pipe tunnel does not properly annunciate when activated.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2024
Resolved 29 April 2024
Resolution: Received ABS report no. 6243011, which in finding no. 1329 reports that the watertight door audible alarm was proven fully operational to the satisfaction of the attending ABS surveyor.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 January 2024
Resolved
A synchroscope is required as part of equipment and instrumentation for switchboards.
Synchroscope reset light on switchboard for SSDG #5 is inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2024
Resolved 5 June 2024
Resolution: Item has been repaired and cleared by attending ABS surveyor.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 January 2024
Resolved
No change shall be made in the machinery, equipment, and other items covered by the survey without the sanction of the Administration.
There are flex hoses for the fuel priming system for some of the SSDGs with apparently field-welded fittings. ABS to assess if current arrangement is suitable for
intended application.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2024
Resolved 28 June 2024
Resolution: Flexible hose and fittings were fabricated and installed in accordance with ABS rules for low-pressure fuel systems at this time and considered satisfactory. ABS report number 6421334
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 31 January 2024
Resolved
Fuel oil service tank no. 24 has an unlabeled valve on a fuel line that is missing the handle and thus cannot be closed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2024
Resolved 29 April 2024
Resolution: Received ABS report no. 6243011, which in finding no. 1331 reports that the tank no. 24 valve was replaced, labeled, and proven fully operational to the satisfaction of the attending ABS surveyor.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 31 January 2024
Resolved
There is evidence of a repair with ‘red-hand’ on a drain line in the overhead of the uppermost cargo hold, aft, amidships area.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2024
Resolved 29 April 2024
Resolution: Received ABS report no. 6243011, which in finding no. 1332 reports that the section of drain piping was cropped/renewed to the satisfaction of the attending ABS surveyor.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 31 January 2024
Resolved
The two radars are not hooked up to the Uninterrupted Power Supply (UPS).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2024
Resolved 5 June 2024
Resolution: Radars have been reconnected to UPS and cleared by the attending ABS surveyor.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 30 January 2024
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use.
The emergency fire pump has a significant seal leak when running.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2024
Resolved 29 April 2024
Resolution: Received ABS report no. 6243011, which in finding no. 1304 reports that the emergency fire pump was overhauled and proven free of leakage to the satisfaction of the attending ABS surveyor.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 September 2023
Resolved
Coast Guard acceptance of automated systems to replace specific personnel or to reduce overall crew requirements is predicated upon a planned maintenance program including routine maintenance, inspection, and testing to ensure the continued safe operation of the vessel. Onboard ship procedures for testing automation did not align with approved PSTPs. Vessel cannot reduce overall crew requirements (PUMS) until changes to PSTPs are submitted and approved.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 27 November 2024
Resolution: Finding 1293.3
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 3 May 2022
Resolved
Each Administration shall require each company to ensure that [.1] each seafarer assigned to any of its ships holds an appropriate certificate in accordance with the provisions of the Convention and [.2] its ships are manned in compliance with the applicable safe manning requirements of the Administration.
Upon activation, provide MMCs for FOS crew to the satisfaction of the attending Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 October 2023
Resolution: MMC checks of FOS crew were carried out by Sector Mobile as part of COI-renewal exam at completion of dry dock.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 1 March 2022
Resolved
Maintenance, testing, and inspections of FFA shall be carried out based on guidelines developed by the Organization. This requires hydrostatic tests of fixed CO2 cylinders at 10 year intervals.
FPS report job # 3204064 for fixed CO2 system of 7/21/2021 indicates that cylinder #s 33399 and KT-106572 were both hydroed in 2009 (EDG room). Both pilot bottles for reefer spaces and fire and hydraulic room were last hydroed in 07/2011. These dates all exceed the 10 year required periodicity.
74 SOLAS 20 II-2/14.2.2.1
Action required: 15 - Rectify deficiencies by next port
Resolved 10 March 2022
Resolution: Received ABS report no. 5181668. It is reported that cylinder # 33399 & the pilot bottles for the hydraulic control room were sent ashore for hydrotesting & then reinstalled onboard. Other mentioned cylinders found w/ in-date hydros stamped on bottles.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 1 March 2022
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: structural fire protection, including fire-resisting divisions, and protections of openings and protections in these divisions.
Double leaf FSD in passageway near library is missing self-closure device and door cannot close and latch. Also, paint locker door does not fully dog and seal.
74 SOLAS 20 II-2/14.2.1.1.1
Action required: 15 - Rectify deficiencies by next port
Resolved 10 March 2022
Resolution: Received ABS report no. 5181668. It is reported that self-closing device for double-leaf FSD was installed and proven functional. Paint locker door was adjusted and proven to be fully functional.
02 - Structural Conditions › N/A - No Subsystem › Loading/Ballast condition
Issued 1 March 2022
Resolved
The condition of the ship and its equipment shall be maintained to conform with regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board.
Ballast tank TLIs are not fully functional. Additionally, multiple ballast valves reported to be malfunctioning, difficult to operate, and/or wired or piped in opposite way.
74 SOLAS 20 I/11 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2022
Resolved 10 March 2022
Resolution: Received ABS report no. 5181668. It is reported that aft peak valves verified operational from control console and position indicators repaired/lights visible. TLIs reported to be a recent installation for BWTS vendor testing and are not considered req'd.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 November 2021
Resolved
All electrical apparatus shall be so constructed and so installed that danger of injury in ordinary handling shall not exist [(a)(i)(1)]. Wiring shall be supported in such a manner as to avoid chafing or other injury [(a)(vi)].
Found transformer in shared space between rooms 426 and 427 extremely warm to touch. This transformer has been wired into a distribution panel in room 430 with wiring passing through SFP boundary in overhead. Noted wire run sitting on top of false overhead in passageway near room 430, outside of cable tray.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 December 2021
Resolved 30 November 2021
Resolution: Accepted by ABS as statutory finding no. 1251. Update on 12/8/21: transformer and associated wiring reported as removed to satisfaction of attending ABS surveyor.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 9 November 2021
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: [.1] structural fire protection.
Section of SFP in overhead of shared space between rooms 426 and 427 has been previously removed and not reinstalled.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 December 2021
Resolved 30 November 2021
Resolution: Accepted by ABS as statutory finding no. 1252. Update on 12/8/21: structural fire protection reported as reinstalled to satisfaction of attending ABS surveyor.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 17 October 2019
Resolved
Every crew member shall participate in at least one abandon ship drill and one fire drill every
month. The drills of the crew shall take place within 24 h of the ship leaving a port if more than 25%
of the crew have not participated in abandon ship and fire drills on board that particular ship in
the previous month. Upon activation and prior to getting underway, conduct satisfactory fire and abandon ship drills. SOLAS (2014) III/19.3.2
Action required: 705 - Other - as specified
Resolved 27 August 2021
Resolution: Crew staffed up to FOS; observed satisfactory fire and abandon ship drills.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 17 October 2019
Resolved
Every officer in charge of a navigational watch serving on a seagoing ship of 500 gross tonnage or more shall hold a certificate of competency. Every officer in charge of an engineering watch in a manned engine-room or designated duty engineer officer in a periodically unmanned engine-room of a seagoing ship powered by main propulsion machinery of 750kw or more shall hold a certificate of competency. Upon activation and prior to getting underway, provide crew license and documents IAW vessel COI. STCW II/1, and III/1
Action required: 705 - Other - as specified
Resolved 27 August 2021
Resolution: Crew staffed up to FOS; carried out satisfactory checks of FOS crew documents.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 December 2018
Resolved
Provide a Repair Proposal to address the leak in the vessel's Low Pressure CO2 System. The Repair Proposal should include causative factor and satisfactory corrective action(s). In addition, a Service Tech Report will be provided to this office attesting to the satisfactory repairs and proper operation of the Low Pressure CO2 system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 December 2018
Resolved 12 February 2019
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 17 December 2018
Resolved
Upon activation and Prior to getting underway, provide cew liceses and documents IAW COI.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 17 December 2018
Resolved 10 January 2019
Resolution: Recieved ABS class report attesting to the satisfactory replacement of the Low PSI CO2 manhold cover gasket, and refill of CO2, system all sat.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 17 December 2018
Resolved
Upon activation and Prior to getting underway, Conduct satisfactory fire and boat drills.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 17 December 2018
Resolved 12 July 2019
Resolution: Witnessed satisfactory fire and boat drills.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 26 June 2018
Resolved
Provide proof of and verify crew license, documents.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 June 2018
Resolved 12 July 2019
Resolution: Verified crew licenses IAW COI manning requirements. All sat.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 26 May 2018
Resolved
Master could not provide original MMC. Provide a master with an MMC to the satsfaction of Class and CG.
Action required: 60 - Rectify deficiencies prior to movement
Due 26 May 2018
Resolved 27 May 2018
Resolution: Class ABS verified new master's MMC.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 26 May 2018
Resolved
Complete Fire and Abandonship drills.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 June 2018
Resolved 12 February 2019