CAPE WASHINGTON
Freight Ship · Ro-Ro Cargo Ship class · USCG East District (CGD-E) · Other hulls named CAPE WASHINGTON
CAPE WASHINGTON is a freight ship. The Coast Guard has recorded 104 inspections since 1994, most recently in June 2026, along with 114 deficiencies — 2 with no resolution recorded —, 1 operational control and 3 casualty investigations between 2018 and 2019.
Records from 1994 to 2026. Most recent: inspection, 25 June 2026.
- Built
- Not recorded
- Last inspected
- 25 June 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Inspections
- 104
- Deficiencies
- 114 recorded · 2 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 3 investigations · 2018–2019
Identity
992285
7826178 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WRGH
387208
Flag
UNITED STATES
303932000 (licence lapsed)
Maury page id
psix-387208
Inspections, by type
…with no type recorded22
Years with a record
30 calendar years (1994–2026)
The 104 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.
Documentation record
Registered dimensions (L × B × D)650.0 ft × 105.8 ft × 44.5 ft
Registered tonnagegross 51,960 / net 36,090
ITC dimensions (L × B × D)650.0 ft × 105.8 ft × 44.5 ft
ITC tonnageNot recorded
BuilderNot recorded
Hull materialSteel
PropulsionDiesel Direct
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNORFOLK, VA
Trade endorsementsRegistry
DocumentationValid · issued 13 February 2026 · expires 28 February 2027
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it51960 - Regulatory (Subpart C or D), Gross Ton
53652 - Displacement, Gross Ton
31355 - Dead Weight, Gross Ton
36090 - Regulatory (Subpart C or D), Net Ton
53652 - Displacement, Gross Ton
31355 - Dead Weight, Gross Ton
36090 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WRGHMMSI 303932000 · expired · compulsorily equipped · granted 13 May 2002, cancelled 14 July 2012
WRGHMMSI 303932000 · expired · compulsorily equipped · granted 2 November 1993, cancelled 2 November 1998
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 104
25 June 2026
ACP Additional Oversight – Risk Assessment
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8410179
11 December 2025
Deficiency Check · Annual Inspection · ACP Annual Oversight
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8281735
15 August 2025
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8210458
7 August 2025
In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8204349
19 February 2025
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8081269
7 February 2025
Deficiency Check · In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8075659
2 December 2024
Deficiency Check · ACP COI Oversight · Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8034746
5 November 2024
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8029800
7 October 2024
In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8015316
28 August 2024
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8009785
3 July 2024
In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7948403
24 June 2024
Administrative Inspection · In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7942287
19 June 2024
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7938315
30 January 2024
Deficiency Check · In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7839364
13 October 2023
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7808026
15 September 2023
Administrative Inspection · Re-Inspection · ACP COI Oversight · MTSA/ISPS Verification · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7790153
12 January 2023
Permit to Proceed
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7622140
16 September 2022
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7560152
13 July 2022
In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7506016
3 May 2022
In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7442894
1 March 2022
Deficiency Check · Administrative Inspection · In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7403617
9 November 2021
In-Service Inspection · ACP Annual Oversight · Annual Inspection · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7348548
16 September 2021
In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7313400
27 August 2021
In-Service Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7300201
19 February 2021
In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7142947
24 September 2020
MTSA/ISPS Verification · Annual Inspection · ACP Annual Oversight
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7066856
24 October 2019
ACP Annual Oversight · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6845736
9 October 2019
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6831522
20 September 2019
In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6818702
12 July 2019
Deficiency Check · In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6746926
18 April 2019
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6665909
19 December 2018
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6600476
19 December 2018
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6624369
17 December 2018
Annual Inspection · MTSA Verification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6599715
6 June 2018
In-Service Inspection · Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6435703
5 June 2018
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6436265
26 May 2018
In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6424548
22 September 2017
COI Inspection · MTSA/ISPS Verification · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6270712
7 August 2017
Drydock Exam · Administrative Inspection · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6240853
2 August 2017
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6237284
24 August 2016
ACP Annual Oversight
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5981841
4 September 2015
ACP Annual Oversight
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5726626
27 August 2014
DAPI Audit · ACP Annual Oversight
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4966193
25 June 2012
In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4356409
22 July 2011
ACP Annual Oversight · DAPI Audit
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4090665
23 September 2010
MTSA/ISPS Verification · Deficiency Check · ACP Annual Oversight
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3855475
15 April 2009
MTSA Verification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3453239
26 August 2008
ACP Annual Oversight
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3357572
3 June 2008
Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3226395
2 June 2008
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3231646
7 October 2005
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2513683
1 September 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2480843
1 September 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2480869
9 August 2005
ACP Periodic Oversight
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2457188
3 May 2005
MTSA/ISPS Verification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2347978
25 October 2004
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2227832
16 September 2004
ACP Annual Oversight
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2197976
26 July 2004
ACP Annual Oversight
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2197900
3 June 2004
MTSA/ISPS Verification
Physical examination · Commandant (CG-CVC) · Activity 2087425
21 May 2004
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2094733
29 January 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1996171
27 August 2003
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1894434
25 August 2003
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1935230
7 August 2003
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1900066
15 November 2002
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1708495
3 October 2002
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1690247
18 September 2002
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1657548
17 January 2002
Examination of Repairs · Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1479461
16 October 2001
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1393662
27 February 2001
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1362006
17 March 2000
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 50272
3 March 2000
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1376154
17 December 1999
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1048025
8 December 1999
Damage Survey · Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1421766
7 September 1999
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1119087
17 February 1999
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1455683
6 October 1998
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 801656
15 September 1998
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 798885
10 September 1998
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1408170
3 March 1998
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1422992
8 October 1997
Examination of Repairs
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1108359
6 October 1997
Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1422922
7 March 1997
Type not recorded
No type recorded · Activities Europe · Activity 214952
7 March 1997
Type not recorded
No type recorded · Activities Europe · Activity 222354
7 March 1997
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 227758
5 March 1997
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 230511
5 March 1997
Re-Inspection · Deficiency Check
Physical examination · Activities Europe · Activity 1374888
3 March 1997
Type not recorded
No type recorded · Activities Europe · Activity 17984
15 January 1997
Drydock Extension
Administrative · Activities Europe · Activity 1098330
31 October 1996
Administrative
Administrative · Activities Europe · Activity 1165709
15 August 1996
Type not recorded
No type recorded · Activities Europe · Activity 170719
23 July 1996
Deficiency Check
Physical examination · Activities Europe · Activity 1086146
10 July 1996
Administrative
Administrative · Activities Europe · Activity 1087097
15 April 1996
Deficiency Check
Physical examination · Activities Europe · Activity 1078020
6 March 1996
COI Inspection
Physical examination · Activities Europe - OLD · USCG Northeast District (CGD-NE) · Activity 1374523
22 January 1996
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 876936
17 November 1995
Deficiency Check
Physical examination · Activities Europe - OLD · USCG Northeast District (CGD-NE) · Activity 1380348
30 August 1995
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 1095616
19 April 1995
Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1168547
27 February 1995
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 61558
15 February 1995
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1163178
19 September 1994
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 13852
11 May 1994
Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 859722
5 April 1994
Hull Examination · Initial Certification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1167790
Deficiency record · 114
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 25 June 2026
Resolved
Every inflatable liferaft shall be serviced at intervals not exceeding 12 months and at an approved servicing station which is competent to service them, maintains proper servicing facilities, and uses only properly trained personnel. Liferaft servicing was due 3 JUN 2026. Ship has ordered servicing prior to commencing inspection. 74 SOLAS (24)III / 20.8
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 25 June 2026
Resolved
All life-saving appliances and arrangements shall comply with the applicable requirements of the Code. Except as otherwise stated, the normal equipment of every life boat shall consist of a food ration totaling not less than 10,000 kJ for each person the lifeboat is permitted to accommodate, kept in airtight packaging and be stored in a watertight container. The vessel currently has 38 of the required 42 rations. Vessel restricted to carriage of no more than 38 persons till rectified.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 25 June 2026
Resolved
A fixed fire-extinguishing system required by paragraph 5 below may be any of the following systems: a fixed gas fire-extinguishing system complying with the provisions of the fire safety systems code. At each location there shall be clear instructions relating to the operation of the system having regard to the safety of personnel. The instructions for the EDG's fixed CO2 system had instructions for local and remote operation posted at both locations, which could lead to potential confusion in the event of an emergency.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 25 June 2026
Resolved
Means shall be provided to close all openings which may admit air to or allow gas toescape from a protected space. Above and aft of the door for the EDG there is a small hole in the bulkhead. 74 SOLAS (97)
II-2/5.1.4
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 25 June 2026
Resolved
In a ship for which oil fuel is used the arrangements for the storage, distribution and use of the oil fuel shall be such as to ensure the safety of the ship and persons on board. Fuel leak detected at he fuel strainer supplying generators 1,2, and 3. Excessive oil observed in the lifeboat engine space. 74 SOLAS (97) II-2/15.2
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 25 June 2026
Resolved
Fire integrity of bulkheads and decks mentioned elsewhere in this part, the minimum fire integrity of bulkheads and decks shall be as prescribed in table 58.1 and 58.2. The A-60 ceiling panel forward of frame 100 on the port side hull was found hanging. Aft of this location there are approximately 10 panels that have minor damage/wear.
01 - Certificates & Documentation › 013 - Documents › Unattended Machinery Spaces (UMS) Evidence
Issued 25 June 2026
Resolved
Measures shall be taken to the satisfaction of the administration to ensure that the equipment is functioning in a reliable manner and the satisfactory arrangements are made for regular inspections and routine tests to ensure continuous reliable operation. PSTP is inaccurate for low level alarm on steering, unable to perform PSTP for power failure on steering pumps. 74 SOLAS (04)
II-1/46.1
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 15 January 2026
Resolved
Any ship of 10,000 gross tonnage and above shall be fitted with oil filtering equipment complying with paragraph 7 of this regulation. Vessel's OWS was not operational. Vessel's crew believes this is related to the sample line solenoid.
MARPOL 73/78 1/14.2
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 January 2026
Resolved
Cables and wiring shall be supported in such a manner as to avoid chafing or other damage. In the vessel's steering gear a new outlet was found installed the wire for which was supported by plastic wire ties.
74 SOLAS (04) II-1/45.5.5
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 15 January 2026
Resolved
The official number of the vessel, preceded by the abbreviation •NO.• must be marked in block-type Arabic numerals not less than three inches in height on some clearly visible interior structural part of the hull. The number must be permanently affixed to the vessel so that alteration, removal, or replacement would be obvious. Official number is not permanently affixed.
46 CFR 67.121
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 7 February 2025
No resolution recorded
Every crew member shall participate in at least one abandon ship drill and one fire drill every month; when a new crew is engaged, these drills shall be held before sailing. Upon activation, conduct fire and abandon ship drills to the satisfaction of the attending Marine Inspector. This will include observing the the rescue
boat and free-fall lifeboat being maneuvered in the water, unless this has been carried out with the CG in attendance within the past 3 months. 74 SOLAS III/19.3.2
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 7 February 2025
No resolution recorded
No vessel may be operated unless it has in its service and on board, the complement required by the certificate of inspection. Upon activation, provide MMC for FOS crew to the satisfaction of the attending Marine Inspector. 46 CFR 15.515
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 2 December 2024
Resolved
Where "A" Class divisions are pierced for the passage of electric cables, pipes,trunks, ducts, etc., for girders, beams or other structures, arrangements shall be made to ensure that the fire resistance is not impaired, subject to the provisions of paragraph (g) of this regulation. The penetration located under the main panel in the fire control station was not properly arranged to ensure fire resistance. 74 SOLAS II-2/23(a)
01 - Certificates & Documentation › 011 - Ships Certificates › Safety Management Certificate (SMC/ ISM)
Issued 3 July 2024
Resolved
74 SOLAS IX 6.2
A ship required to hold a certificate issued pursuant to the provisions of regulation 4.3 shall be subject to control in accordance with the provisions of regulation XI/4. For this purpose such certificate shall be treated as a certificate issued under regulation I/12 or I/13. Vessel’s Safety Management Certificate has been revoked following ISM audit.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 3 July 2024
Resolved
74 SOLAS 2020 II-2 14.2.1
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: fire detection and fire alarm systems. It was found that vessel’s found that cargo deck’s fire detection system was inoperable. During inspection it was discovered that the cargo fire detection system has not been working since 16 MAY 2024. The ship must maintain an hourly round among the cargo decks until the system is repaired.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 25 June 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel reported leak in their fire main investigate source of leak and test entire system to the satisfaction of the attending marine inspector. 74 SOLAS I/11a
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 25 June 2024
Resolved
The means of control of any fixed gas fire-extinguishing system shall be readily accessible, simple to operate and shall be grouped together in as few locations as possible at positions not likely to be cut off by a fire in a protected space. At each location there shall be clear instructions relating to the operation of the system having regard to the safety of personnel. The instructions posted for the low pressure CO2 system do not provide clear instructions for the operation of the system. In addition the master valve was found locked crew stated the only person with the key is the chief engineer. 74 SOLAS II-2 4.1.1.1.1
FSS Chp 5.2.1.3.3 17ac
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 24 June 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to sea without danger to the ship or persons on board. The vessel reported a breach in the vessel's hull with water ingression into the vessel. The following requirements are to be followed and rectified to the satisfaction of the attending marine inspector and the vessel's RO:
1. Identify and control the source of the leak.
2. Secure the space where the leak is occurring.
3. Make hourly rounds of the space to ensure water ingress does not increase beyond what is currently occurring.
4. Staff the vessel with adequate personnel to dewater the vessel in the case of an emergency. 74 SOLAS I/11a 17ac
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 19 June 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board.
Vessel reported a leak in their ballast piping system.
Temporary patch/plug has been put in place.
SOLAS I/11(a)
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 16 April 2024
Resolved
Each berthing area shall be equipped with information regarding reporting of sexual assault and sexual harassment that meets 46 USC 11101. In each washing space there shall be information regarding procedures...
The required information is not posted in all necessary spaces. See CVC Policy Letter 23-04 for amplifying information.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 16 April 2024
Resolved
Information regarding all access and use of the vessel's master key shall be recorded in a log book. Crew not included on the list described in subsection (a)(2) shall not have access to or use of the master key unless in an emergency and shall immediately notify the master and owner of the vessel following use of such key.
A master key control log is not being maintained up to
date onboard. Additionally, the current CGS SMS policy
regarding master key control authorizes various shoreside personnel and other crew members temporary use of the master key to perform work related functions and completion of an assigned task, respectively. This is not permitted under the statute. See CVC Policy Letter 23-06 for amplifying information.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 31 January 2024
Resolved
The Company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements that may be established by the Company.
There are technical and operational deficiencies noted in the original inspection report/835V (dated 1/31/24, pgs. 1-20) that indicate a serious failure / lack of effectiveness of implementation of the safety management system.
An external SMC audit, at least equivalent in scope to a renewal audit, is required to be carried out by the RO (ABS) prior to the vessel's departure from port.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 31 January 2024
Resolved
Before the ship leaves port, all life-saving equipment shall be in working order and ready for immediate use.
Primary steering for free fall lifeboat found to be inoperable during in-water test.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 31 January 2024
Resolved
Any ship of >10,000 gross tons shall be fitted with oil filtering equipment, approved by the Administration, with alarm arrangements, etc.
The full and proper functionality of the OWS/OCM could not be demonstrated, as the ppm could not be reduced below 35-40 when tested.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 31 January 2024
Resolved
Every oil fuel pipe, which, if damaged, would allow oil to escape from a storage, settling, or daily service tank shall be fitted with a valve capable of being closed from a safe position outside the space concerned in the event of a fire occurring in the space.
Proper operation of the quick closing valves for the oil system could not be demonstrated at this time. Additionally, the PSTP for testing of these valves is inaccurate when compared with the actual onboard arrangement. Prove proper operation of all quick closing valves and revise the PSTP to reflect the onboard arrangements.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 31 January 2024
Resolved
The ISM Company should ensure that inspections are held at appropriate intervals and appropriate corrective action is taken.
Vibration analysis and thermography was carried out in September 2023 as part of post dry-dock sea trial, with multiple serious/unsatisfactory findings noted. Additionally, a large percentage of equipment included on the report was listed as either OOC or not run, and therefore readings not taken. All items noted in need of repair to be addressed, and readings to be taken for missing items, with rectification of any new/additional findings. Provide the results of updated/new report to both ABS and CG.
*UPDATE*
29 May 2024
Appropriate measure have been taken to correct outstanding items for vibration/themograpy. Once vessel activates, contractor will attend to reconduct surveys and verify corrective action. Changed from 17 to 705.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 31 January 2024
Resolved
An efficient bilge piping pumping system shall be provided.
The proper operation of the emergency bilge suction could not be demonstrated. No venturi effect/suction noted with the eductor running.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 31 January 2024
Resolved
The ISM Company should ensure that inspections are held at appropriate intervals and appropriate corrective action is taken.
The latest lube oil analysis report from Tribologik noted multiple critical conditions. Additionally, most all sampling history does not indicate a sample within the past 6 months. Appropriate action to be taken for all noted items, and oil analysis taken for missing/overdue items, with rectification of any new/additional findings. Provide the results to both ABS and CG.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 31 January 2024
Resolved
Fire-fighting systems and appliances shall be kept in good working order.
Multiple fire station hydrant valves found leaking by when the fire main was energized, including in shaft tunnel, steering flat (station #96), engine room (station #93), fire station 53, and fire station 26. These fire hydrant valves to be repaired or replaced, and ABS to subsequently carry out complete walkdown of fire main while energized to confirm all hydrant valves are in proper working order.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 January 2024
Resolved
Relief valves for air receivers marked as last tested in 2018, for auxiliary boiler in 2018, and for exhaust gas boiler in 2017 (all >5 years ago). Associated work order in NSE listed as overdue by >200 days. All of these relief valves shall be tested, and proper relieving setpoints verified, to the satisfaction of the attending ABS surveyor.
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 31 January 2024
Resolved
The vessel does not currently hold a valid IOPP certificate. ABS removed the IOPP and issued a SOF due to onboard engine room piping arrangements not complying with the MARPOL I/12.3 requirements (see ABS finding 1205). However, holding an IOPP is mandatory for vessels enrolled in ACP and to comply with 33 CFR requirements. Make necessary modifications to piping arrangements onboard to comply with MARPOL I/12.3 amendments and regain IOPP certificate.
*Update*
29 May 2024
Vessel has contracted company to complete repairs and make piping modification bilge piping. Changed from 17 to 705. Once repairs are made then deficiency will be closed.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 31 January 2024
Resolved
A minimum of 2 two-way portable radiotelephone apparatus for each fire party for fire-fighters communication shall be carried on board, of the explosion-proof or intrinsically safe type.
No firefighter radios that are properly rated for use in hazardous area currently provided onboard.
*UPDATE*
05 June 2024
Vessel has procured radios for use in hazardous area. Changed from 17 to 705. Will clear once ABS attending surveyor has approved and operationally tested satifactory.
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 31 January 2024
Resolved
Every ship shall be provided with a main steering gear to the satisfaction of the Administration.
There is a steering alarm on the main steering stand on the navigation bridge that cannot be cleared and is of unknown origin/cause.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 31 January 2024
Resolved
Fire protection systems shall be kept in good working order to ensure their required performance if a fire occurs.
The vent damper and cargo hold fan indicator panel on the bridge has multiple indicator lights burnt out, and the low oil level light is constantly illuminated. Replace all burnt out bulbs. Determine and correct cause of low oil level alarm.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 31 January 2024
Resolved
The following navigation lights are not properly functioning at this time:
• aft anchor lower on main nav light panel
• aft anchor port lower on main nav light panel
• multiple lights on the 'Christmas tree' panel
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 31 January 2024
Resolved
The protection of openings and penetrations in fire-resisting divisions shall be kept in good order so as to ensure their required performance if a fire occurs.
Multiple cable penetrations found to have missing or improper firestop/sealing, including in the following locations:
• In the cabinets for the newly installed radars at the deck penetration
• Underneath the GMDSS suite and VDR box at the deck penetration
• At the bulkhead above the door going into room 380
• At the bulkhead into room 341 (laundry)
• At the bulkhead into room 430
• At the deck penetration for the fire detection panel in the ballast control room
The above list is not to be interpreted as all-inclusive. A complete survey of penetrations of fire rated boundaries is required to be carried out by ABS or a third party, and any issues corrected. Provide the survey/inspection results to the CG for their review and concurrence.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 31 January 2024
Resolved
Mechanical appliances for washing/toilet spaces shall be kept in good working order.
Accommodation exhaust fan for toilets is locked out/tagged out, motor partially disassembled, and belt for fan motor missing.
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 31 January 2024
Resolved
Fire Control Plans shall be kept up to date.
Rev G of the Fire Control Plan was found to have multiple inaccuracies. ABS shall carry out full onboard verification of the FCP, revisions to be made and re-approved as necessary.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 31 January 2024
Resolved
The muster list shall specify substitutes for key persons who may become disabled.
Substitution for key personnel is not listed on the station bill posted on the navigation bridge.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 31 January 2024
Resolved
Fire protection systems shall be kept in good working order to ensure their required performance if a fire occurs.
The vent damper and cargo hold fan indicator panel in the ballast control room has multiple inop indicator
lights. Replace all inop indicator lights.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 31 January 2024
Resolved
Waste receptables shall be constructed of non-combustible material with no openings in the sides or bottom.
Plastic trash cans found in use throughout the accommodation spaces, along with some in the engine room, with various combustible trash inside. Per MSC Circular 1120, plastic waste receptacles are only allowed if used solely for wet waste, glass bottles, and metal cans and are suitably marked.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 31 January 2024
Resolved
The maintenance hatch going down to the bow thruster room has a gap with light coming through. ABS to confirm watertight or weathertight requirements on LL-11-D, and appropriate repairs to be made as needed.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 31 January 2024
Resolved
Maintenance, testing, and inspection of life-saving appliances shall be carried in a manner having due regard to ensuring reliability of such appliances.
The 3 year pressure testing of the immersion suits was last carried out on 08 January 2021 and is now overdue
(annual testing of several older suits overdue in 1/22).
10 - Safety of Navigation › N/A - No Subsystem › Pilot ladders and hoist/pilot transfer arrangements
Issued 31 January 2024
Resolved
Pilot ladder winch reel as currently arranged does not meet the applicable statutory requirements. The pilot ladder is not secured at deck level >915mm horizontally inward from the ship’s side, and weight of pilot ladder can still be partially hanging on the reel. ABS to carry out full evaluation of onboard pilot embarkation arrangements against the applicable requirements. The above-noted and any additional discrepancies identified by ABS to be addressed.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 31 January 2024
Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard.
The HPU for the cargo vent dampers has multiple leaks with diapers and a bucket arranged to catch leaks. Additionally, the electrical junction box cover is off, with exposed wires.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 31 January 2024
Resolved
Before the ship leaves port, all life-saving equipment shall be in working order.
High-pressure hydraulic lines running from the HPU to
the FFLB davit have multiple loose or missing support brackets, causing the lines to vibrate excessively.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 31 January 2024
Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard.
In the pipe tunnel, near the split aft of the emergency fire pump room, there is a significant amount of standing hydraulic oil. Identify the source(s) of the leak(s) and clean up the standing oil.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 31 January 2024
Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard.
There is pooled hydraulic oil in the bilge in the bow thruster room. Identify the source(s) of the leak(s) and clean up the standing oil.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 31 January 2024
Resolved
The following emergency lights were found inoperable during testing of e-lighting while on EDG power:
• Light at top of stairwell heading down towards galley
• Light in ballast control room near the exterior door
• Light in LPCO2 room near the door
Additionally, there was no e-lighting in the two storage compartments (aft, port side) for the fireman’s outfits on 12 deck.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 31 January 2024
Resolved
Fire hazards are to be minimized.
Multiple areas of oil-soaked lagging and pipe insulation found in the engine room, purifier room, and provision refrigeration equipment compartment. Any oil-soaked lagging or insulation to be replaced; painting is not permitted.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Incinerator incl. operations and operating manual
Issued 31 January 2024
Resolved
The incinerator shall be properly and fully decommissioned if no longer in use. At present:
-Containment for incinerator fuel oil tank vent is holed
-Fuel tank appears still partially full, but quick
closing valve is not hooked up. Fuel lines need to be
disconnected and blanked off.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 31 January 2024
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use.
• On the starboard LPCO2 tank there is visible corrosion on an approximately 1 inch diameter line coming off the inboard end near where the refrigeration coils enter the tank. Provide a report of thickness gauging or other nondestructive testing in order for ABS and CG to assess the condition of this section of piping and suitability for continued service.
• On the small-diameter line leading from the CO2 pilot bottle for the incinerator, there is a section of piping just above the manual release cabinet with visible corrosion. Provide a report of thickness gauging or other nondestructive testing in order for ABS and CG to assess the condition of this section of piping and suitability for continued service.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 31 January 2024
Resolved
The master, owner, operator, agent or person in charge of any vessel equipped with ballast tanks that operates in the waters of the United States must maintain a ballast water management plan that has been developed specifically for the vessel and that will allow those responsible for the plan’s implementation to understand and follow the vessel’s BWM strategy and comply with the requirements of this subpart.
The vessel’s ballast water management plan available onboard at time of inspection, dated August 2013, is out-of-date / incorrect. Specifically, it states that ballast water exchange is still a permissible ballast water management method for the vessel, but for vessels such as the Cape Washington that are past the implementation schedule in 151.2035, ballast water exchange is no longer a permissible management option. Revise the ballast water management plan to the satisfaction of the CG.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 31 January 2024
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: structural fire protection.
The following issues with structural fire protection were found during the inspection:
• A section of the SFP has been folded back in the radio room.
• SFP missing on overhead above fire damper access panel R15Q across from the hospital.
• A section of SFP is missing near the door of room 370 (air condition center).
• A section of SFP is missing in the overhead in the passageway near the entrance to room 430 (electrical switchboard room).
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 31 January 2024
Resolved
The following fire protection systems shall be kept in good order as to ensure their required performance if a fire occurs: penetrations and openings in fire-resisting divisions.
The following issues with fire dampers were identified:
• The second from port side fire damper for room 218 (rec room) sticks when pulled.
• Hydraulic room oil cooler intake and exhaust vents
have dry-rotted gaskets on the vent dampers.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 31 January 2024
Resolved
Electrical installations shall ensure the safety of crew and ship from electrical hazards.
The following electrical issues were identified during the course of the inspection:
• Backup batteries for the GMDSS suite not properly secured/strapped down.
• An extension cord is plugged into a 220V outlet in the passageway across from room 374, that goes to a step-down transformer to power a route. To be removed or hard-wired.
• Junction box on aft bulkhead of EDG spacing facing the freefall lifeboat is missing its cover and with exposed wires.
• Bonding wires missing on multiple cargo hold fan enclosures on 12 deck.
• The cable/wiring run for the emergency fire pump near the motor itself is not properly supported.
• Port side steering pump controller hanging by wires.
• Sewage tank level junction box missing cover.
• Dead end wiring in the EDG overhead that runs outside the EDG to a junction box that is wide open.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 31 January 2024
Resolved
For remote hand operation of watertight doors, an audible alarm shall be configured to sound when the door is moving.
The audible alarm for the class 2 watertight door for the pipe tunnel does not properly annunciate when activated.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 January 2024
Resolved
A synchroscope is required as part of equipment and instrumentation for switchboards.
Synchroscope reset light on switchboard for SSDG #5 is inoperable.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 January 2024
Resolved
No change shall be made in the machinery, equipment, and other items covered by the survey without the sanction of the Administration.
There are flex hoses for the fuel priming system for some of the SSDGs with apparently field-welded fittings. ABS to assess if current arrangement is suitable for
intended application.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 31 January 2024
Resolved
Fuel oil service tank no. 24 has an unlabeled valve on a fuel line that is missing the handle and thus cannot be closed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 31 January 2024
Resolved
There is evidence of a repair with ‘red-hand’ on a drain line in the overhead of the uppermost cargo hold, aft, amidships area.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 31 January 2024
Resolved
The two radars are not hooked up to the Uninterrupted Power Supply (UPS).
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 30 January 2024
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use.
The emergency fire pump has a significant seal leak when running.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 September 2023
Resolved
Coast Guard acceptance of automated systems to replace specific personnel or to reduce overall crew requirements is predicated upon a planned maintenance program including routine maintenance, inspection, and testing to ensure the continued safe operation of the vessel. Onboard ship procedures for testing automation did not align with approved PSTPs. Vessel cannot reduce overall crew requirements (PUMS) until changes to PSTPs are submitted and approved.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 3 May 2022
Resolved
Each Administration shall require each company to ensure that [.1] each seafarer assigned to any of its ships holds an appropriate certificate in accordance with the provisions of the Convention and [.2] its ships are manned in compliance with the applicable safe manning requirements of the Administration.
Upon activation, provide MMCs for FOS crew to the satisfaction of the attending Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 1 March 2022
Resolved
Maintenance, testing, and inspections of FFA shall be carried out based on guidelines developed by the Organization. This requires hydrostatic tests of fixed CO2 cylinders at 10 year intervals.
FPS report job # 3204064 for fixed CO2 system of 7/21/2021 indicates that cylinder #s 33399 and KT-106572 were both hydroed in 2009 (EDG room). Both pilot bottles for reefer spaces and fire and hydraulic room were last hydroed in 07/2011. These dates all exceed the 10 year required periodicity.
74 SOLAS 20 II-2/14.2.2.1
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 1 March 2022
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: structural fire protection, including fire-resisting divisions, and protections of openings and protections in these divisions.
Double leaf FSD in passageway near library is missing self-closure device and door cannot close and latch. Also, paint locker door does not fully dog and seal.
74 SOLAS 20 II-2/14.2.1.1.1
02 - Structural Conditions › N/A - No Subsystem › Loading/Ballast condition
Issued 1 March 2022
Resolved
The condition of the ship and its equipment shall be maintained to conform with regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board.
Ballast tank TLIs are not fully functional. Additionally, multiple ballast valves reported to be malfunctioning, difficult to operate, and/or wired or piped in opposite way.
74 SOLAS 20 I/11 (a)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 November 2021
Resolved
All electrical apparatus shall be so constructed and so installed that danger of injury in ordinary handling shall not exist [(a)(i)(1)]. Wiring shall be supported in such a manner as to avoid chafing or other injury [(a)(vi)].
Found transformer in shared space between rooms 426 and 427 extremely warm to touch. This transformer has been wired into a distribution panel in room 430 with wiring passing through SFP boundary in overhead. Noted wire run sitting on top of false overhead in passageway near room 430, outside of cable tray.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 9 November 2021
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: [.1] structural fire protection.
Section of SFP in overhead of shared space between rooms 426 and 427 has been previously removed and not reinstalled.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 17 October 2019
Resolved
Every crew member shall participate in at least one abandon ship drill and one fire drill every
month. The drills of the crew shall take place within 24 h of the ship leaving a port if more than 25%
of the crew have not participated in abandon ship and fire drills on board that particular ship in
the previous month. Upon activation and prior to getting underway, conduct satisfactory fire and abandon ship drills. SOLAS (2014) III/19.3.2
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 17 October 2019
Resolved
Every officer in charge of a navigational watch serving on a seagoing ship of 500 gross tonnage or more shall hold a certificate of competency. Every officer in charge of an engineering watch in a manned engine-room or designated duty engineer officer in a periodically unmanned engine-room of a seagoing ship powered by main propulsion machinery of 750kw or more shall hold a certificate of competency. Upon activation and prior to getting underway, provide crew license and documents IAW vessel COI. STCW II/1, and III/1
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 December 2018
Resolved
Provide a Repair Proposal to address the leak in the vessel's Low Pressure CO2 System. The Repair Proposal should include causative factor and satisfactory corrective action(s). In addition, a Service Tech Report will be provided to this office attesting to the satisfactory repairs and proper operation of the Low Pressure CO2 system.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 17 December 2018
Resolved
Upon activation and Prior to getting underway, provide cew liceses and documents IAW COI.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 17 December 2018
Resolved
Upon activation and Prior to getting underway, Conduct satisfactory fire and boat drills.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 26 June 2018
Resolved
Provide proof of and verify crew license, documents.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 26 May 2018
Resolved
Master could not provide original MMC. Provide a master with an MMC to the satsfaction of Class and CG.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 26 May 2018
Resolved
Complete Fire and Abandonship drills.
Stability › Watertight Integrity › General
Issued 25 June 2012
Resolved
Forward engineroom Port and Stbd watertight doors in process of being repaired. Prove proper operation of both doors and alarm systems in local and remote.
Fire Fighting › Fire Pumps › Arrangement
Issued 25 June 2012
Resolved
Repair discharge gauge for main fire pump.
Operations/Management › Drills/Instruction › Fire
Issued 23 September 2010
Resolved
Demonstrate Fire and Abandon ship drills to the satisfaction of the attending marine Inspector prior to getting underway.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 23 September 2010
Resolved
Provide curent licenses, TWIC and documents for all crew members.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 26 August 2008
Resolved
Provide wiring schematics for #1 and #2 Steering gear controlers.
Engineering › Lubricating Oil Service System › Piping
Issued 26 August 2008
Resolved
Make repairs to HFO leakin port pipe tunnel.
Engineering › Lubricating Oil Service System › Pump
Issued 26 August 2008
Resolved
Remove bucket of oil in containment and make repairs to flange to prevent continued leaking.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 26 August 2008
Resolved
Remove clamps from F.O. piping flange and make repairs to prevent leaking.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Nozzle, Injection (fuel injection)
Issued 26 August 2008
Resolved
Replace missing bolts for the F.O. pumps H.P. leak-off lines on #1 SSDG.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Valve
Issued 26 August 2008
Resolved
Make repairs to the EDG shutdown cable and demonstrate proper shutdown of engine.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 26 August 2008
Resolved
Povide all licenses and certificates and documents for all crew members prior to departure from port of baltimore.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 26 August 2008
Resolved
Complete a satisfactory abandom ship drill prior to departure from port of Baltimore.
Stability › Watertight Integrity › General
Issued 3 June 2008
Resolved
Due to coupling failure of hydraulic hose to stbd. side watertight door ram (stern ramp), door is stuck in the open position, unable to be closed. Replace coupling and hose. Make repairs and prove proper operation prior to operation to satisfaction of class (ABS) or USCG Marine Inspector.
Construction/Loadline › Structures › Door
Issued 3 June 2008
Resolved
Class (ABS) to attest to approval of hydraulic hose and new coupling for watertight door, stbd side ram, prior to installation.
Lifesaving › Lifeboat
Issued 23 April 2002
Resolved
Demonstrate free fall lifeboat operation.
Operations/Management › Drills/Instruction
Issued 23 April 2002
Resolved
Demonstrate fire and lifeboat drills prior to carrying cargo to the satisfaction of an attending arine inspector. LEGACY COMPONENT DESC: Fire and Lifeboat
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 23 April 2002
Resolved
Complete system testing for all cargo holds and provide certification of system operation for the low pressure CO2 system. LEGACY COMPONENT DESC: Operating Controls
Fire Fighting › International Shore Connection › Flange
Issued 17 January 2002
Resolved
Provide two correct International shore connection fitiings.
Fire Fighting
Issued 27 February 2001
Resolved
DUE TO REMOVAL OF HOISTABLE DECKS WITHIN VEHICLE HOLDS, THE UPPER FIRE STATIONS/EXTINGUISHERS ARE INACCESSIBLE, RENDERING CURRENT FIRE CONT PLAN INVALID IN THESE AREAS. UPON COMPLETION OF VEHICLE DECK MODIFICATIONS, PROVIDE UPDATED, APPROVED FIRE CONTROL PLAN.
Lifesaving
Issued 17 February 1999
Resolved
Conduct a thourough inspection and make permanent repairs to the fiberglassand metal components as necessary in way of the lifting gear on the stern launched life boat and its associated attachment points. To be completed tothe satisfaction of the attending marine inspector and the cognizant OCMI.
Lifesaving
Issued 17 February 1999
Resolved
Conduct weight test to the new stern launched lifeboat cable that was installed 01APR99. Conduct weight test for lifeboat lifting gear. To be completed to the satisfaction of the attending marine inspector and the cognizant OCMI.
Unknown
Issued 3 March 1998
Resolved
PRIOR TO GETTING U/W, PROVIDE UPDATED MEDICINE IN HOSPITAL FOR INSPECTION BY USCG MARINE INSPECTOR.
Navigation
Issued 3 March 1998
Resolved
PRIOR TO GETTING U/W, PROVIDE UPDATED CHARTS & PUBS FOR INSPECTION BY USCG MARINE INSPECTOR.
Construction/Loadline
Issued 6 October 1997
Resolved
Hydrostatically test #2 port side tank and #3 starboard side tank, upon completion of firemain repairs.
Construction/Loadline
Issued 6 October 1997
Resolved
Prove proper operation of hydraulic ballast valve (NCV1012).
Construction/Loadline
Issued 6 October 1997
Resolved
Remove bilge suction bell mount (outboard) in #6 starboard, for bottom plate examination during drydock.
Fire Fighting
Issued 6 October 1997
Resolved
Hydrostatically test firemain, upon completion of pipe renewal.
Construction/Loadline
Issued 6 October 1997
Resolved
Renew sounding tube, #2 port.
Lifesaving
Issued 23 July 1996
Resolved
Conduct a full load weight test to both single point liferaft davits. Testto be conducted to the satisfaction of the attending Coast Guard Marine Inspector.
Construction/Loadline
Issued 6 March 1996
Resolved
Make permanent repairs to vent line in way of cement patch on starboard seawater strainer.
Lifesaving
Issued 6 March 1996
Resolved
Provide condition report and recommended repairs (if any) for crack in lifeboat hull.
Engineering
Issued 22 January 1996
Resolved
Provide machinery logs/problem reports and associated automation documents and materials for review in conjunction with conducting sea trial for approval of automation procedure to satifaction of attending inspector at time of 1996 COI.
Electrical
Issued 19 April 1995
Resolved
Install approved intrinsically safe or explosion proof light fixtures in the fwd and aft battery rooms and the paint locker as per 46CFR111.105-41 for battery rooms and 46CFR111.105-43 for paint lockers.
Accommodation/Occupational Safety
Issued 19 April 1995
Resolved
Install forced exhaust ventilation in paint locker 46CFR92.15-10(a)(b)(e).
Lifesaving
Issued 19 April 1995
Resolved
Install large radius rollers in rescue boat daqvit base to prevent cables from chaffing on davit base while lowering and raising the boat. structurally reinforce davit base opening for roller installation.
Accommodation/Occupational Safety
Issued 19 April 1995
Resolved
INSTALL EXHAUST VENT STACK FOR FWD BATTERY FOOM ONE METER ABOVE THE OVERHEAD OF THE BATTERY ROOM AS REQUIRED FOR MODERATE SIZE BATTERY, 46CFR111.15-10(d)(2)(i)(ii)(iii)(iv)._x001C_
Casualty record · 3
5 June 2018Routine · role: Involved in a Marine Casualty · activity 6436265
19 December 2018Routine · role: Involved in a Marine Casualty · activity 6624369
18 April 2019Routine · role: Involved in a Marine Casualty · activity 6665909
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.