Records from 2016 to 2026. Most recent: inspection, 24 June 2026.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 19
24 June 2026
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8405918
10 June 2025
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8145669
12 November 2024
Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8033825
8 May 2024
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7908514
6 June 2023
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7704619
7 November 2022
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7602541
17 March 2022
COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7422918
11 May 2021
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7194635
17 November 2020
Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7096731
14 July 2020
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7006320
14 June 2019
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6714148
5 November 2018
Administrative Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6574687
5 June 2018
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6434601
19 April 2018
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6394685
10 May 2017
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6163462
15 February 2017
COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6088739
1 November 2016
Administrative Inspection · Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6033069
26 May 2016
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5888238
29 March 2016
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5842891
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 June 2026
Resolved
At least one ring life buoy must be fitted with a lifeline. If more than one ring life buoy is carried, at least one must not have a lifeline attached. Each lifeline on a ring life buoy must:(1) Be buoyant;(2) Be of at least 18.3 meters (60 feet) in length;(3) Be non-kinking;(4) Have a diameter of at least 7.9 millimeters (5/16 inch);(5) Have a breaking strength of at least 5 kilonewtons (1,124 pounds); and(6) Be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light. MI observed the ring life buoy's lifeline (and grabline) to be deteriorated and showing signs of fraying.
Cite: 46 CFR 180.70(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 July 2026
Resolution: Received photographic evidence of a new lifeline attached to the lifering
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 June 2026
Resolved
The material specification shall show that the rigid nonmetallic material possesses characteristics adequate for its intended service and environment and shall be approved for use by the Officer in Charge, Marine Inspection. MI observed the nonmetallic piping for the engine's transmission system was not replaced in-kind nor did it contain SAE J1942 approval markings. Provide current nonmetallic piping specifications to the OCMI for review along with a report from the engine manufacturer allowing the current nonmetallic piping material to be used instead of original material.
Cite: 46 CFR 182.40-1(4)
"Old T"
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 July 2026
Resolution: Operator submitted proof of new line meeting J1942 requirements
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 June 2025
Resolved
Vessels described by 46 CFR 175.110(c) must have interconnected fire detection system in compliance with 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. MI observed no fire detection system in forward accommodation space. Vessel shall install fire detection device.
46 CFR 181.405(c)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 June 2025
Resolution: Received photographic evidence of smoke detector installation. all sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 May 2024
Resolved
A Vessel of 12 meters or more in lenght shall be provided with a whistle. The sound signaling device on board was found to be inoperable. Recommended repair or replace.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 May 2024
Resolution: Vessel rep sent video proof of functional sound signaling device.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 29 May 2024
Resolved
Each vessel certificated to operate on an oceans route in warm water must be provided with life floats of an aggregate capacity that will accommodate at least 100% of the total number of persons permitted on board. The Life Float was found with holes in the structure and the life line was degraded. Recommened replace or repair Life Float and life line through approved means.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2024
Resolved 26 November 2024
Resolution: New life float installed meeting minimum passenger capacity.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 29 May 2024
Resolved
At least one ring life buoy must be fitted with a lifeline. Each lifeline on a ring life buoy must have a breaking strength of at least 5 kilo-newtons (1,124 pounds). The life line was found degraded and frayed. Recommend Repair or replace through approved means.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2024
Resolved 26 November 2024
Resolution: Life buoy line replaced. Observed in person at drydock.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 May 2024
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. The stenciling was found faded and worn. Recommend re-stencil the deck to properly indicate location of fuel shut-off.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2024
Resolved 26 November 2024
Resolution: Fuel shut-offs properly labeled and clearly marked, witnessed in person during drydock.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 6 June 2023
Resolved
When a marine employer determines that a casualty or incident is, or is likely to become, an SMI, the marine employer must ensure that the following alcohol and drug testing is conducted: Alcohol testing must be conducted on each individual engaged or employed on board the vessel who is directly involved in the SMI. The alcohol testing of each individual must be conducted within 2 hours of when the SMI occurred, unless precluded by safety concerns directly related to the incident. Vessel was missing alcohol testing swabs. Vessel is limited to operating no more than 2 hours away from an alcohol testing location.
46 CFR 4.06-3(a)(1)(i)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 June 2023
Resolution: provided photo evidence of new alcohol testing swabs
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 4 April 2022
Resolved
No marine employer shall engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer. New deckhand has not been enrolled in a drug consortium or passed a pre-employment drug test. Provide proof of enrollment in drug consortium and negative pre-employment drug test.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2022
Resolution: Rcvd documentation that deckhand was enrolled in drug consortium and completed pre-employment drug test.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 4 April 2022
Resolved
The marine employer shall ensure that all persons directly involved in a serious marine incident are chemically tested for evidence of dangerous drugs and alcohol in accordance with the requirements of 46 CFR 4.06. No alcohol testing strips/swabs were on board. Provide adequate number of alcohol testing strips.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2022
Resolution: Alcohol test strips were placed on board.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 April 2022
Resolved
Three (03) adult life jackets and one (01) child-size life jackets were lacking Type I retroflective material. Replace retro tape on identified life jackets. Passenger count is reduced to 7 passengers and 1 child.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 April 2022
Resolution: 3 new adult life jackets and 1 new child life jackets placed on board.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 11 May 2021
Resolved
Vessel must comply with FCC requirements for any radio installation; vessel's FCC radio telephony certificate was expired. Renew certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2021
Resolved 16 June 2021
Resolution: Obtained new FCC Safety Radiotelephony Certificate dated 6/14/2021.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 11 May 2021
Resolved
Each survival craft on a vessel must be in good working order and ready for immediate use. Life float light battery is expired. Renew battery.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2021
Resolved 2 June 2021
Resolution: Photos of newly installed batteries.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 11 May 2021
Resolved
A vessel must carry a first aid kit equivalent to 160.041; vessel first aid kit had expired ammonia inhalents and burn gel, replace item with non-expired items.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2021
Resolved 2 June 2021
Resolution: Photos of new required medical items.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 11 May 2021
Resolved
Vessel is required to meet mandatory testing requirements for drug and alcohol; alcohol swabs are expired. Replace swabs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2021
Resolved 2 June 2021
Resolution: Photos of new alcohol test strips.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 20 June 2019
Resolved
Valid FCC Marine Radio Operator Permit required on board. Provide valid FCC Permit.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2019
Resolved 2 July 2019
Resolution: Provided valid FCC Marine Radio Operator Permit
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 20 June 2019
Resolved
Vessel must carry up-to-date charts for operating area. Provide charts with applicable updates.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2019
Resolved 24 July 2019
Resolution: Vessel received up-to-date charts
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 20 June 2019
Resolved
Three 2.5 gallon buckets labeled "Fire Bucket" with lanyard required. Provide fire buckets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2019
Resolved 2 July 2019
Resolution: Provided three 2.5 gallon fire buckets with appropriate label and lanyards.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 20 June 2019
Resolved
Life float must have working water light approved under 161.010. Provide working water light.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2019
Resolved 2 July 2019
Resolution: Repaired waterlight and demonstrated proper operation
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 20 June 2019
Resolved
Vessel must have working navigational lights. Masthead light must be operational. Vessel is restricted to daytime operations until fixed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2019
Resolved 2 July 2019
Resolution: Repaired masthead light and demonstrated satisfactory operation
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 June 2019
Resolved
Required portable fire extinguishers must be in serviceable condition. Fire extinguisher on bridge is not fully charged. Provide suitable extinguisher.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2019
Resolved 2 July 2019
Resolution: Had fire extinguisher serviced and repaired seal leak
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 20 June 2019
Resolved
High water alarm must have an audible and visual indicator light. Provide working high water alarm.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2019
Resolved 2 July 2019
Resolution: Reapaired audio alarm so vessel now has audio and visual indicators of high water level.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 June 2019
Resolved
Reflective tape must be in working condition on life jackets. Provide new tape on 04 life jackets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2019
Resolved 2 July 2019
Resolution: Replaced reflective tape on lifejackets with new tape
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 June 2019
Resolved
Vessel must have name and hailing port marked on the stern. Renew vessel name and hailing port on stern.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2019
Resolved 2 July 2019
Resolution: Repainted fading vessel name and homeport on stern
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 8 May 2018
Resolved
Fixed CO2 fire extinguishig system is due for annual inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 June 2018
Resolved 30 May 2018
Resolution: Annual inspection conducted on fixed CO2 system.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 8 May 2018
Resolved
Portable fire extinguishers are due for annual inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 May 2018
Resolved 30 May 2018
Resolution: Annual inspection conducted on portable fire extinguishers.
Documentation › Markings/Placards › Lifejacket Placard
Issued 4 April 2017
Resolved
Provide placards containing instructions for the donning and use of the life jackets aboard the vessel (must be provided for child life jacket of different style). 46 CFR 185.516
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 May 2017
Resolved 4 April 2017
Resolution: Owner replaced different life jacket for one of same style as the rest to which the donning instructions applied. Donning instructions on board are adequate for all life jackets.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 4 April 2017
Resolved
Dispose of expired first aid kit items and replace contents IAW 46 CFR 160.041.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 May 2017
Resolved 10 May 2017
Resolution: New items purchased for med kit.
Stability › Weathertight Integrity › General
Issued 25 April 2016
Resolved
Rubber gaskets on weathertight doors are worn. Replace rubber gaskets on both head and operating station doors IAW 46 CFR 179.360.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 26 May 2016
Resolution: Rubber gaskets renewed on weathertight doors.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 25 April 2016
Resolved
EAP supervisor training not completed. Complete EAP training IAW 46 CFR 16.401.
Condition: Invalid
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 26 May 2016
Resolution: EAP Supervisor training verified completed.