MAURY USCG vessel records Sign in
← All vessels

KAMCHATSKIY PROLIV

KAMCHATSKIY PROLIV is a 1981 freight ship. The Coast Guard has recorded 13 inspections since 1993, most recently in December 2009, along with 24 deficiencies and 1 operational control.

Records from 1993 to 2009. Most recent: inspection, 29 December 2009.

Built
1981
Last inspected
29 December 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8228476 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
387254
Flag
RUSSIA
—
Maury page id
psix-387254

Inspections, by type

…with no type recorded4
Years with a record 11 calendar years (1993–2009)
The 13 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.

Documentation record

Tonnage as PSIX records it13518 - Regulatory (Subpart C or D), Gross Ton
13518 - Convention (Subpart B), Gross Ton
5906 - Regulatory (Subpart C or D), Net Ton
20350 - Dead Weight, Ton
22287 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 13

29 December 2009 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3656263
4 January 2008 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3121373
7 January 2007 Deficiency Check
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2851563
5 October 2006 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2769761
15 March 2005 ISPS II Exam · Ballast Water Examination · PII Safety Exam · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2310666
8 March 2004 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2020725
9 September 2003 Ballast Water Examination · Re-Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1901079
26 June 2003 Annual Inspection · Ballast Water Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1826402
29 October 2002 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1697594
25 June 2002 Annual Inspection · Ballast Water Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1635709
20 January 2000 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 273795
28 September 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 383110
15 April 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 483786

Deficiency record · 24

Fire Fighting › Fixed Halon Fire Extinguishing System › Nozzle
Issued 5 October 2006 Resolved
Halon nozzles were mising in #3 reefer hold.
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 January 2007
Resolution: The halon nozzles in #3 reefer hold have been replace/installed.
Lifesaving › Lifeboat › Hull
Issued 8 March 2004 Resolved
NOTED EXCESSIVE BUBBLING OF FIBERGLASS (NOT JUST GELCOAT.) PUNCHED HOLE IN ONE BLISTER WHICH LEAKED WATER AND OIL. AT MINIMUM BLISTERS WILL NEED TO BE REPAIRED BY CERTIFIED COMPANY. ALSO REPAIRS TO THE KEEL HAVE SEPARATED. FLAG REP TO ATTEST TO CONDITIONS OF LIFEBOATS. LEGACY COMPONENT DESC: Hull
Action required: 15 - Rectify deficiencies by next port
Resolved 15 March 2005
Resolution: Cleared deficiency. Member noted no concerns regarding prevoiusly mentioned problems on fiberglass on lifeboat.
Fire Fighting › Fixed Halon Fire Extinguishing System › Quantity of Halon
Issued 8 March 2004 Resolved
FLAG REP TO DETERMINE MINIMUM LEVEL OF HALON REQUIRED AND LEVELS NOW IN TANKS. CURRENT GAUGES AND MARKINGS ARE NOT ADEQUATE. ONE TANK APPEARS LOW. FLAG REP TO PROVIDE REPORT ATTESTING TO CORRECTION.
Action required: 15 - Rectify deficiencies by next port
Resolved 15 March 2005
Resolution: Examined bottle levels. All tanks appear to be sat.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 26 June 2003 Resolved
Several fire extinguishers found without service labels, one under-charged. LEGACY COMPONENT DESC: Service
Due 25 July 2003
Resolved 9 September 2003
Resolution: Provided class surveyers report attesting to repairs.
Stability › Water on Deck
Issued 26 June 2003 Resolved
Standing water was found on deck on cabin 70. The deck drain was stopped and the screen clogged. Ensure deck drains are clean and clear.
Due 25 July 2003
Resolved 9 September 2003
Resolution: Provided class surveyers report attesting to repairs.
Electrical › Lighting (service)
Issued 26 June 2003 Resolved
More than 15 lights were inoperable in various closets, galley, dry stores and reefers. Ensure all fixtures operable. LEGACY COMPONENT DESC: Lighting Fixture
Due 25 July 2003
Resolved 9 September 2003
Resolution: Provided class survey report attesting to repairs.
Electrical › Lighting (service)
Issued 26 June 2003 Resolved
Many Light covers, gloges and guards missing throughout the ship, replace as required.
Due 25 July 2003
Resolved 9 September 2003
Resolution: Provided class survey report attesting to repairs.
Navigation › Collision/Grounding Avoidance
Issued 25 June 2002 Resolved
Inop ARPA/Primary radar. LEGACY COMPONENT DESC: Automatic Radar Plotting Aid (ARPA)
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 July 2002
Resolution: Rcvd class report
Documentation › Logs/Records
Issued 25 June 2002 Resolved
Required pre-arrival/entry tests not conducted in accordance with 33 CFR 164.25. LEGACY COMPONENT DESC: Logbook (official)
Action required: 705 - Other - as specified
Resolved 3 July 2002
Resolution: Rcvd class report
Personnel › Training
Issued 25 June 2002 Resolved
Crew unable to conduct basic fire drills. LEGACY COMPONENT DESC: Fire Fighting Basic
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 July 2002
Resolution: Rcvd class report
Fire Fighting › Fixed Fire Detection System
Issued 25 June 2002 Resolved
Fire detection system not operating properly. Various trouble lights stay lit. LEGACY COMPONENT DESC: Control Panel
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 July 2002
Resolution: Rcvd class report
Engineering › Steering Gear System
Issued 25 June 2002 Resolved
Structural fire protection missing/badly deteriorated above steering gear system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 July 2002
Resolved 3 July 2002
Resolution: Rcvd class report
Electrical › Electrical Distribution System (service)
Issued 25 June 2002 Resolved
Dead end wires in the vicinity of Oily Water Seperator. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 July 2002
Resolved 3 July 2002
Resolution: Rcvd class report
Accommodation/Occupational Safety › Occupational Safety
Issued 25 June 2002 Resolved
Loose deck plates in the engine room near Main Engine are a personnel hazard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 July 2002
Resolved 3 July 2002
Resolution: Rcvd class report
Navigation
Issued 20 January 2000 Resolved
PROVE OPERATION OF ARPA CAS SYSTEM FOR RADAR PRIOR TO DEPARTURE FROM PASCAGOULA, MISSISSIPPI. PROVIDE TECHNICIAN REPORTS ATTESTING TO ITS PROPER OPERATION TO USCG MSO MOBILE UPON REPAIR.
Condition: Unknown
Due 28 January 2000
Resolved 31 January 2000
Lifesaving
Issued 28 September 1995 Resolved
INSTALL RETROREFLECTIVE TAPE ON ALL LIFEBOATS IN ACCORDANCE WITH SOLAS 74 AMENDED III/30.2.7.
Condition: Unknown
Due 6 October 1995
Resolved 9 October 1995
Documentation
Issued 28 September 1995 Resolved
PROVIDE ON BOARD UP TO DATE MEDICAL RECORDS FOR REQUIRED VACCINATIONS FOR NUMEROUS CREW MEMBERS IN ACCORDANCE WITH ILO 147.
Condition: Unknown
Due 6 October 1995
Resolved 9 October 1995
Lifesaving
Issued 28 September 1995 Resolved
INSTALL NEW RETROREFLECTIVE TAPE ON ALL LIFE BUOYS IN ACCORDANCE WITH SOLAS74 AMENDED III/30.2.7.
Condition: Unknown
Due 6 October 1995
Resolved 9 October 1995
Lifesaving
Issued 28 September 1995 Resolved
PROPERLY SERVICE 10 INFLATABLE LIFERAFTS TO ACCOMPLISH ANNUAL REQUIREMENT IN ACCORDANCE WITH SOLAS 74 AMENDED III/19.8.1.
Condition: Unknown
Due 6 October 1995
Resolved 9 October 1995
Lifesaving
Issued 28 September 1995 Resolved
PROPERLY SERVICE ALL INFLATABLE LIFERAFT HYDROSTATIC RELEASES TO ACCOMPLISHANNUAL REQUIREMENT IN ACCORDANCE WITH SOLAS 74 AMENDED III/19.9.1.
Condition: Unknown
Due 6 October 1995
Resolved 9 October 1995
Fire Fighting
Issued 28 September 1995 Resolved
PROVIDE ACCECPTIBLE COPY OF SERVICE REPORT OR PROVIDE SERVICING FOR ALL PORTABLE FIRE EXTINGUISHERS TO SATISFY ANNUAL REQUIREMENT IN ACCORDANCE_x001C_ WITH SOLAS 74 AMENDED II-2/21.
Condition: Unknown
Due 6 October 1995
Resolved 9 October 1995
Fire Fighting
Issued 28 September 1995 Resolved
PROVIDE ON BOARD 10 SERVICEABLE FIRE HOSES WITH NOZZLES AND HYDRANT CONNECTORS IN ACCORDANCE WITH SOLAS 74 AMENDED II-2/21.
Condition: Unknown
Due 6 October 1995
Resolved 9 October 1995
Documentation
Issued 28 September 1995 Resolved
PROVIDE ON BOARD WRITTEN GARBAGE PLAN IN ACCORDANCE WITH MARPOL 73/78 ANNEXV/4.
Condition: Unknown
Due 6 October 1995
Resolved 9 October 1995
Lifesaving
Issued 28 September 1995 Resolved
PROVE PROPER OPERATION OF ALL LIFEBOAT ENGINES IN ACCORDANCE WITH SOLAS 74 AMENDED III/19.2.
Condition: Unknown
Due 6 October 1995
Resolved 9 October 1995

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.