MAURY USCG vessel records Sign in
← All vessels

SUN ROSE

SUN ROSE is a 1993 tank ship. The Coast Guard has recorded 19 inspections since 1993, most recently in November 2007, along with 8 deficiencies and 3 operational controls.

Records from 1993 to 2007. Most recent: operational control imposed, 3 November 2007.

Built
1993
Last inspected
2 November 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9011076 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
387283
Flag
UNKNOWN
—
Maury page id
psix-387283

Inspections, by type

…with no type recorded10
Years with a record 8 calendar years (1993–2007)
The 19 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it52525 - Regulatory (Subpart C or D), Gross Ton
28208 - Regulatory (Subpart C or D), Net Ton
95621 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 19

2 November 2007 MARPOL Annex V Examination · ISPS II Exam · MARPOL Annex I Examination · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3091730
27 February 2003 Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1746911
29 August 2002 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1668451
29 July 2002 Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1653625
9 June 2002 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1628315
9 June 2002 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1628321
4 February 2002 Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1483809
16 August 2001 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 292856
9 February 2001 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 286509
8 February 2001 Tank Vessel Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1062828
26 March 1996 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 390307
26 March 1996 Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1084096
10 November 1995 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 384518
11 April 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 377992
16 May 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 515354
16 May 1994 Tank Vessel Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 858205
11 December 1993 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 502181
17 September 1993 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 361018
24 May 1993 Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 829305

Deficiency record · 8

Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Pump
Issued 2 November 2007 Resolved
Vsl unable to demonstrate proper operation of ODME.
Action required: 705 - Other - as specified
Resolved 9 November 2007
Resolution: The vessel provided a Class report attesting to the proper operation of the ODME.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 2 November 2007 Resolved
Vsl cargo tank overfill audible alarm is not operating in the cargo control room.
Action required: 705 - Other - as specified
Resolved 9 November 2007
Resolution: The vessel submitted a Class report attesting to the proper operation of the overfill audible alarm.
Engineering › Diesel Engine (propulsion-direct drive) › Crankshaft
Issued 2 November 2007 Resolved
Vsl's main engine has a significant lube oil leak coming from rear seal.
Action required: 705 - Other - as specified
Resolved 9 November 2007
Resolution: The vessel submitted a Class report stating the vessel is safe to sail until next dry dock period.
Engineering › Steam System (auxiliary) › Piping
Issued 2 November 2007 Resolved
Vsl has steam leak on cargo heating line on deck at Vsl has steam leak on cargo heating line on deck at # 6 port cargo tank.
Action required: 705 - Other - as specified
Resolved 9 November 2007
Resolution: The vessel submitted a Class report attesting to the proper operation of the cargo heating line.
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 2 November 2007 Resolved
Vsl crew drained and open the deck water seal to manually operate low water alarm on IGS.
Action required: 705 - Other - as specified
Resolved 3 November 2007
Resolution: Received class report attesting to correction to deck water seal deficiency.
Lifesaving › Lifejacket/PFD (Type I)
Issued 29 August 2002 Resolved
PFD lights had expired batteries. Issued requirement to replace lights prior to departure. Agent will fax invoice to USCG. LEGACY COMPONENT DESC: Lights
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 August 2002
Resolution: Fax copy of invoice received at ACYNY.
Navigation › Piloting/Steering
Issued 9 June 2002 Resolved
Issued LOD 02-004 by request for non funtional gyrocompass LEGACY COMPONENT DESC: Gyro Compass
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 14 June 2002
Resolution: Received letter from capt. stating that the gyrocompass has been repaired.
Unknown
Issued 26 March 1996 Resolved
PROVIDE CLASSIFICATION SOCIETY LETTER STATING THE VESSEL MEETS U.S. DOUBLE HULL REQUIREMENTS IN 33 CFR 157.10d.
Condition: Unknown
Due 23 May 1996
Resolved 23 May 1996

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.