COLORADO KING I

Built
1993
Last inspected
8 September 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 8 September 2025
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCO9994
387330
Flag
UNITED STATES
Maury page id
psix-387330

Documentation record

Registered dimensions (L × B × D)49.0 ft × 18.0 ft × 3.0 ft
Registered tonnagegross 50 / net 45
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPADDLE KING · YUMA, AZ, UNITED STATES · built 1993
Hull materialAluminum
PropulsionDiesel
Hull shapeBox
Hull configurationMonohull
Hailing portYUMA, AZ
Endorsements, as the file codes themcw_un
DocumentationValid · issued 22 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it50 - Simplified, Gross Ton
45 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 12 inspections, each with its date, unit and type; 18 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 12

8 September 2025 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8179676
14 April 2025 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8095099
9 November 2024 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8034432
29 March 2024 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7890749
8 January 2023 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7620627
8 February 2022 Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7387469
25 October 2021 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7329141
22 September 2020 Internal Structural Exam · Drydock Exam · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7071732
16 November 2019 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6850205
26 December 2018 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6602817
8 January 2018 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6323220
16 December 2016 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6045539

Deficiency record · 18

03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 8 September 2025 Resolved
Forward engine compartment bulkhead was found with a cut-out hole, re-weld and make bulkhead watertight.
Action required: 705 - Other - as specified
Resolved 15 September 2025
Resolution: Bulkhead re-welded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 September 2025 Resolved
Port paddle wheel structure found to be cracked, make appropriate weld repairs.
Action required: 705 - Other - as specified
Resolved 15 September 2025
Resolution: Crack re-welded.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 September 2025 Resolved
Electrical extension cord found permanently installed in engine compartment, remove extension cord.
Action required: 705 - Other - as specified
Resolved 15 September 2025
Resolution: Cord removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 November 2024 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. Paddle wheel could not produce propulsion. Belt came off of pulley causing loss of propulsion. Provide operational propulsion. 46 CFR 182.100
Action required: 10 - Deficiency Rectified
Resolved 9 November 2024
Resolution: New belt installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 March 2024 Resolved
All cables for electrical installations must meet 46 CFR 111.60-1 and 111.60.11 for marine applications. 12 volt batteries use welding cables as primary power supply. Vessel operator must provide evidence that cables are allowed for marine use IAW federal regulations or replace in kind with approved battery cabling.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2024
Resolved 21 May 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 March 2024 Resolved
Vessel operators required to notify USCG when a marine casualty occurs IAW 46 CFR 185.202. Upon reviewing vessel log books noted two occasions when vessel was involved in minor marine casualties without notification to USCG. Vessel operator educated on notification procedures for marine casualties by USCG Marine Inspectors.
Action required: 10 - Deficiency Rectified
Resolved 29 March 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 January 2023 Resolved
At least one ring life buoy must be equipped with a lifeline. Ring buoy was not equipped with a lifeline. Acquire lifeline for ring buoy that is buoyant, non-kinking, of at least 60 feet in length, have a breaking strength of at least 1,124 pounds, and be of dark color or of a type resistant to deterioration from UV light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2023
Resolved 16 March 2023
Resolution: Received picture of correction.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 January 2023 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Adult and child size life jackets were mixed together. Adequately separate all adult and child life jackets and appropriately label each life jacket container.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 January 2023
Resolved 14 April 2025
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 8 January 2023 Resolved
Two (02) portable fire extinguishers were not mounted with manufacturer approved mounts. Mount extinguishers with manufacturer approved mounts.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 January 2023
Resolved 14 April 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 January 2023 Resolved
Each small battery installation must be located in a well ventilated space and protected from falling objects. Provide an adequate cover for the battery installation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2023
Resolved 14 April 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 8 February 2022 Resolved
Paddle wheels found to be misaligned with port being inoperable. Align paddle wheels and repair port propulsion.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 February 2022
Resolution: Aligned paddle wheels and replaced shaft key allowing for full operation of propulsion machinery.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 8 February 2022 Resolved
Unable to complete operational test of steering due to paddle wheel alignment. Complete steering test in the presence of Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 February 2022
Resolution: Paddle wheels were aligned and full operational test of steering was performed.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 22 September 2020 Resolved
Emergency drills shall be conducted prior to operating.
Action required: 705 - Other - as specified
Resolved 21 August 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 26 December 2018 Resolved
Annual insepction lasped.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 January 2023
Resolution: Vessel completed annual inspection.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 January 2018 Resolved
Provide serviceable first aid kit
Action required: 705 - Other - as specified
Due 8 February 2018
Resolved 8 February 2018
Navigation › Piloting/Steering › Marine Charts
Issued 8 January 2018 Resolved
Provide charts for area of operation
Action required: 705 - Other - as specified
Due 8 February 2018
Resolved 8 February 2018
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 8 January 2018 Resolved
Provide fire ext brackets
Action required: 705 - Other - as specified
Due 8 February 2018
Resolved 8 February 2018
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 8 January 2018 Resolved
Provide garbage plan
Action required: 705 - Other - as specified
Due 8 February 2018
Resolved 8 February 2018

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.