MAURY USCG vessel records Sign in
← All vessels

COLORADO KING I

COLORADO KING I is a 1993 passenger vessel (inspected). The Coast Guard has recorded 39 inspections since 1993, most recently in September 2025, along with 65 deficiencies and 1 casualty investigation in 2006.

Records from 1993 to 2025. Most recent: inspection, 8 September 2025.

Built
1993
Last inspected
8 September 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCO9994
387330
Flag
UNITED STATES
—
Maury page id
psix-387330

Inspections, by type

…with no type recorded2
Years with a record 29 calendar years (1993–2025)
The 39 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)49.0 ft × 18.0 ft × 3.0 ft
Registered tonnagegross 50 / net 45
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPADDLE KING · YUMA, AZ, UNITED STATES · built 1993
Hull materialAluminum
PropulsionDiesel
Hull shapeBox
Hull configurationMonohull
Hailing portYUMA, AZ
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 22 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it50 - Simplified, Gross Ton
45 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCO9994MMSI not assigned · expired · voluntarily equipped · granted 1 December 1994, cancelled 5 February 2005
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 39

8 September 2025 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8179676
14 April 2025 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8095099
9 November 2024 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8034432
29 March 2024 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7890749
8 January 2023 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7620627
8 February 2022 Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7387469
25 October 2021 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7329141
22 September 2020 Internal Structural Exam · Drydock Exam · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7071732
16 November 2019 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6850205
26 December 2018 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6602817
8 January 2018 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6323220
16 December 2016 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6045539
13 October 2015 Hull Examination · COI Inspection · Internal Structural Exam · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5731643
7 September 2011 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4138364
21 October 2010 DAPI Audit · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3863151
3 December 2009 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3643404
26 November 2008 Internal Structural Exam · Annual Inspection · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3370001
19 November 2007 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3097610
3 February 2006 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2586407
1 November 2005 Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2504018
30 August 2005 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2480890
18 January 2005 Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2273780
2 November 2004 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2257687
18 October 2004 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2223130
17 August 2004 Internal Structural Exam · Drydock Extension
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2157123
8 July 2004 Administrative Inspection
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2126099
21 December 2003 Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1951466
20 December 2002 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1718286
3 December 2001 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1399746
12 January 2000 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1418646
16 September 1999 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1440193
17 November 1998 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1446705
9 September 1998 Drydock Extension
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 799335
11 May 1998 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1427518
2 April 1997 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1364065
26 March 1996 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1360492
17 May 1995 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1380241
2 April 1994 Deficiency Check · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 859392
11 August 1993 Hull Examination · Initial Certification · Plan Review "T" Boat
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1385114

Deficiency record · 65

03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 8 September 2025 Resolved
Forward engine compartment bulkhead was found with a cut-out hole, re-weld and make bulkhead watertight.
Action required: 705 - Other - as specified
Resolved 15 September 2025
Resolution: Bulkhead re-welded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 September 2025 Resolved
Port paddle wheel structure found to be cracked, make appropriate weld repairs.
Action required: 705 - Other - as specified
Resolved 15 September 2025
Resolution: Crack re-welded.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 September 2025 Resolved
Electrical extension cord found permanently installed in engine compartment, remove extension cord.
Action required: 705 - Other - as specified
Resolved 15 September 2025
Resolution: Cord removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 November 2024 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. Paddle wheel could not produce propulsion. Belt came off of pulley causing loss of propulsion. Provide operational propulsion. 46 CFR 182.100
Action required: 10 - Deficiency Rectified
Resolved 9 November 2024
Resolution: New belt installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 March 2024 Resolved
All cables for electrical installations must meet 46 CFR 111.60-1 and 111.60.11 for marine applications. 12 volt batteries use welding cables as primary power supply. Vessel operator must provide evidence that cables are allowed for marine use IAW federal regulations or replace in kind with approved battery cabling.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2024
Resolved 21 May 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 March 2024 Resolved
Vessel operators required to notify USCG when a marine casualty occurs IAW 46 CFR 185.202. Upon reviewing vessel log books noted two occasions when vessel was involved in minor marine casualties without notification to USCG. Vessel operator educated on notification procedures for marine casualties by USCG Marine Inspectors.
Action required: 10 - Deficiency Rectified
Resolved 29 March 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 January 2023 Resolved
At least one ring life buoy must be equipped with a lifeline. Ring buoy was not equipped with a lifeline. Acquire lifeline for ring buoy that is buoyant, non-kinking, of at least 60 feet in length, have a breaking strength of at least 1,124 pounds, and be of dark color or of a type resistant to deterioration from UV light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2023
Resolved 16 March 2023
Resolution: Received picture of correction.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 January 2023 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Adult and child size life jackets were mixed together. Adequately separate all adult and child life jackets and appropriately label each life jacket container.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 January 2023
Resolved 14 April 2025
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 8 January 2023 Resolved
Two (02) portable fire extinguishers were not mounted with manufacturer approved mounts. Mount extinguishers with manufacturer approved mounts.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 January 2023
Resolved 14 April 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 January 2023 Resolved
Each small battery installation must be located in a well ventilated space and protected from falling objects. Provide an adequate cover for the battery installation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2023
Resolved 14 April 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 8 February 2022 Resolved
Paddle wheels found to be misaligned with port being inoperable. Align paddle wheels and repair port propulsion.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 February 2022
Resolution: Aligned paddle wheels and replaced shaft key allowing for full operation of propulsion machinery.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 8 February 2022 Resolved
Unable to complete operational test of steering due to paddle wheel alignment. Complete steering test in the presence of Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 February 2022
Resolution: Paddle wheels were aligned and full operational test of steering was performed.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 22 September 2020 Resolved
Emergency drills shall be conducted prior to operating.
Action required: 705 - Other - as specified
Resolved 21 August 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 26 December 2018 Resolved
Annual insepction lasped.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 January 2023
Resolution: Vessel completed annual inspection.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 January 2018 Resolved
Provide serviceable first aid kit
Action required: 705 - Other - as specified
Due 8 February 2018
Resolved 8 February 2018
Navigation › Piloting/Steering › Marine Charts
Issued 8 January 2018 Resolved
Provide charts for area of operation
Action required: 705 - Other - as specified
Due 8 February 2018
Resolved 8 February 2018
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 8 January 2018 Resolved
Provide fire ext brackets
Action required: 705 - Other - as specified
Due 8 February 2018
Resolved 8 February 2018
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 8 January 2018 Resolved
Provide garbage plan
Action required: 705 - Other - as specified
Due 8 February 2018
Resolved 8 February 2018
Lifesaving › Lifebuoys › Serviceable
Issued 13 October 2015 Resolved
Ring buoy worn. Provide adequate lifering with line attached.
Condition: Improper/Lack of Maintenance
Due 13 November 2015
Resolved 13 November 2015
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 September 2011 Resolved
Provide contents in first aid kit as per 46 CFR 160.041
Condition: Improper/Lack of Maintenance
Due 7 October 2011
Resolved 2 November 2011
Resolution: Replaced all expired items in first aid kit.
Engineering › Steering Gear System › Pump
Issued 7 September 2011 Resolved
Prove proper operation of steering system
Action required: 705 - Other - as specified
Due 12 October 2011
Resolved 2 November 2011
Resolution: Proved proper operation of steering system.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 21 October 2010 Resolved
Renew or hydrostatic test all portable fire extinguishers. (1-B1 and 4-BII's)
Action required: 705 - Other - as specified
Due 21 November 2010
Resolved 27 October 2010
Fire Fighting › Fire Bucket › Lanyard
Issued 21 October 2010 Resolved
Renew lanyards on fire buckets to reach the water from the upper deck.
Action required: 705 - Other - as specified
Due 21 November 2010
Resolved 1 November 2010
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 21 October 2010 Resolved
Properly mark child size life preservers storage with 14.
Action required: 705 - Other - as specified
Due 21 November 2010
Resolved 1 November 2010
Engineering › Steering Gear System › Hydraulic Hose
Issued 21 October 2010 Resolved
Renew broken chain support for propulsion hydraulic hoses
Action required: 705 - Other - as specified
Due 21 November 2010
Resolved 1 November 2010
Engineering › Lubricating Oil Service System › Gauge
Issued 21 October 2010 Resolved
Renew engine oil pressure gauge at the operating station
Action required: 705 - Other - as specified
Due 21 November 2010
Resolved 1 November 2010
Electrical › Electric Supply System (service) › Battery Installation
Issued 21 October 2010 Resolved
Install batteries in boxes with covers. (Plastic battery boxes)
Action required: 705 - Other - as specified
Due 21 November 2010
Resolved 1 November 2010
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 21 October 2010 Resolved
Properly attach grounding strap for the fuel oil tank fill tube.
Action required: 705 - Other - as specified
Due 21 November 2010
Resolved 1 November 2010
Electrical › Electric Generation Source (service) › Switch
Issued 21 October 2010 Resolved
Properly cover back of battery switch
Action required: 705 - Other - as specified
Due 21 November 2010
Resolved 1 November 2010
Electrical › Electric Generation Source (service) › Conductor
Issued 21 October 2010 Resolved
Remove or properly install the yellow wire with alligator clip to a on/off switch.
Action required: 705 - Other - as specified
Due 21 November 2010
Resolved 1 November 2010
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 21 October 2010 Resolved
Provide company policy and locate/identify a SAP (substance abuse professional) in the Yume area.
Action required: 705 - Other - as specified
Due 21 November 2010
Resolved 22 November 2010
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 October 2010 Resolved
Provide aspirin for the first aid kit
Action required: 705 - Other - as specified
Due 21 November 2010
Resolved 4 November 2010
Communications › Alarms/Indicators › Bilge Alarm
Issued 3 December 2009 Resolved
Properly label bilge alarms in pilot house IAW 46CFR182.530
Action required: 705 - Other - as specified
Due 3 January 2010
Resolved 17 August 2010
Construction/Loadline › Penetrations › Flange Pad
Issued 3 December 2009 Resolved
Cap Port and Starboard thru holes on bow 46CFR179.350
Action required: 705 - Other - as specified
Due 3 January 2010
Resolved 17 August 2010
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 3 December 2009 Resolved
Renew expired first aid items
Action required: 705 - Other - as specified
Due 3 January 2010
Resolved 6 January 2010
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 3 December 2009 Resolved
Provide floating line for ring buoy IAW 46CFR180.70
Action required: 705 - Other - as specified
Due 3 January 2010
Resolved 3 December 2009
Resolution: Corrected
Documentation › Logs/Records › Logbook (official)
Issued 3 December 2009 Resolved
Log drills quarterly IAW 46CFR185.520 and 46CFR185.524
Action required: 705 - Other - as specified
Due 3 January 2010
Resolved 3 December 2009
Engineering › Bilge Water Management System › Interface Detector
Issued 1 November 2005 Resolved
Prove proper operation (audible and visual) of engine space bilge alarm IAW 46CFR 182.530 (Old T not exempt).
Action required: 705 - Other - as specified
Due 1 December 2005
Resolved 2 November 2005
Resolution: Demonstrated proper operation of bilge alarm.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 November 2005 Resolved
Properly shield portside nav. light (red) with proper arc of visibility IAW Inland Nav Rules (46CFR183.420 & 33 CFR 84).
Action required: 705 - Other - as specified
Due 1 December 2005
Resolved 9 November 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Valve
Issued 1 November 2005 Resolved
Mark fuel oil shut off with operating instructions indicating location and direction to move. (46CFR185.608)
Action required: 705 - Other - as specified
Due 1 December 2005
Resolved 9 November 2005
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 18 January 2005 Resolved
Found vessel did not have COD on board, nor evidence that owner was in process of obtaining one. Required to correct IAW 46 CFR 67.7 & .313.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2005
Resolved 10 February 2005
Resolution: Verified new COD on board.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 18 January 2005 Resolved
Replace buoyant lifeline on ring buoy with proper type and length IAW 46 CFR 180.70(c).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 January 2005
Resolved 10 February 2005
Lifesaving › Visual Distress Signals (General) › Expired
Issued 18 January 2005 Resolved
Replace expired distress signals (flares) IAW 46 CFR 180.68(b).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 January 2005
Resolved 10 February 2005
Engineering › Fuel Oil Service System › Valve
Issued 18 January 2005 Resolved
Repair and prove proper operation of fuel shut-off valve operable from outside tank compartment IAW existing vessel reg 46 CFR 182.15-40 (Old T).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 January 2005
Resolved 10 February 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 18 January 2005 Resolved
Move masthead light to proper position IAW 33 CFR 84.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 January 2005
Resolved 10 February 2005
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 18 January 2005 Resolved
Renew Emergency Broadcast Instructions Placard IAW 46 CFR 184.506.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 January 2005
Resolved 10 February 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 January 2005 Resolved
Replace/refill missing and expired items in first aid kit IAW 46 CFR 184.710.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 February 2005
Resolved 10 February 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 18 January 2005 Resolved
Provide missing cover for overhead light on upper deck IAW existing (Old) T regs 46 CFR 183.01-5 and 46 CFR 183.01-15.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 February 2005
Resolved 10 February 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 January 2005 Resolved
Remove dead-end wires in engine space IAW existing (Old) T regs 46 CFR 183.01-5 and 46 CFR 183.01-15.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 February 2005
Resolved 10 February 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 January 2005 Resolved
Install metal supports no more than 24" apart on newly-installed electrical cable in #1 void IAW 46 CFR 183.340.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 February 2005
Resolved 10 February 2005
Documentation
Issued 3 December 2001 Resolved
Post COI pages for viewing by passengers.
Condition: Unknown
Due 1 April 2002
Resolved 20 December 2002
Lifesaving
Issued 3 December 2001 Resolved
Provide 3 smoke signals.
Condition: Unknown
Due 1 April 2002
Resolved 20 December 2002
Lifesaving
Issued 3 December 2001 Resolved
Replace expired items in first aid kit.
Condition: Unknown
Due 1 April 2002
Resolved 20 December 2002
Documentation
Issued 3 December 2001 Resolved
Post stability letter on bridge.
Condition: Unknown
Due 1 April 2002
Resolved 20 December 2002
Electrical
Issued 3 December 2001 Resolved
secure and cover STBD battery box.
Condition: Unknown
Due 1 April 2002
Resolved 20 December 2002
Documentation
Issued 3 December 2001 Resolved
FAX drug program information to MSO San Diego prior to 15 DEC01.
Condition: Unknown
Due 6 December 2001
Resolved 6 December 2001
Lifesaving
Issued 12 January 2000 Resolved
Renew distress signals.
Condition: Unknown
Due 1 February 2000
Resolved 26 January 2000
Lifesaving
Issued 2 April 1997 Resolved
have on board first aid kit per 46cfr 184.710
Condition: Unknown
Due 14 April 1997
Resolved 14 April 1997
Fire Fighting
Issued 2 April 1997 Resolved
have on board 3 2.5 gallon firebuckets
Condition: Unknown
Due 14 April 1997
Resolved 14 April 1997
Lifesaving
Issued 2 April 1997 Resolved
redo retroreflective tape on lifering buoy
Condition: Unknown
Due 14 April 1997
Resolved 14 April 1997
Navigation
Issued 26 March 1996 Resolved
provide .6 meter day shape. (anchor ball)
Condition: Unknown
Due 10 April 1996
Resolved 3 May 1996
Engineering
Issued 26 March 1996 Resolved
provide 30x30 flame screen on fuel tank vents
Condition: Unknown
Due 10 April 1996
Resolved 3 May 1996
Engineering
Issued 17 May 1995 Resolved
Provide flame screen for fuel tank vent and bonding strap between fuel fillpipe and fuel tank.
Condition: Unknown
Due 17 May 1995
Resolved 17 May 1995
Documentation
Issued 17 May 1995 Resolved
Provide information to prove compliance with random drug testing program. (Vessel will not operate until DEC 95.)
Condition: Unknown
Due 17 May 1995
Resolved 17 May 1995
Navigation
Issued 11 August 1993 Resolved
PROVE PROPER OPERATION OF NAVIGATION LIGHTS FAILURE INDICATOR AND ALARM. _x001C_ VESSEL LIMITED TO DAYLIGHT OPERATION UNTIL REQUIREMENT IS COMPLETED. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 August 1993
Resolved 11 August 1993

Casualty record · 1

3 February 2006Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2586407
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record