Records from 1997 to 2008. Most recent: inspection, 9 April 2008.
Inspection history · 28
9 April 2008
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3180426
24 January 2008
Random ISPS/MTSA/PSC · MARPOL Annex V Examination · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3135375
6 December 2007
Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 3110909
12 July 2007
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2992631
26 May 2007
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2946207
23 May 2007
Ballast Water Examination · MARPOL Annex V Examination · ISPS II Exam · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2938013
11 September 2006
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2775561
1 August 2006
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2732887
12 July 2006
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2710480
9 July 2006
MARPOL Annex I Examination · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2706339
4 April 2006
Random ISPS/MTSA/PSC
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2616170
15 February 2006
Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 2585569
2 August 2005
ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2448459
19 May 2004
MARPOL Annex I Examination · MTSA/ISPS Verification · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2071892
27 April 2004
Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2053659
27 April 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2058128
26 April 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2052693
24 April 2004
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2051637
12 March 2004
MTSA/ISPS Verification
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2023290
5 December 2003
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1966069
4 December 2003
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1962645
15 April 2003
Annual Inspection · Ballast Water Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1774278
31 May 2002
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1628765
18 March 2002
Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1494325
13 February 2002
Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1486304
12 December 2001
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 296110
19 September 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1071614
15 October 1997
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 408979
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 24 January 2008
Resolved
Vessel's Main Engine #5 and #9 Jacket Lines are leaking down on both sides of engine due to cold temperature, which results in the bilge level alarm to activate. Make permanent repairs within 45 days to the satisfaction of Class.
Action required: 705 - Other - as specified
Due 8 March 2008
Resolved 9 March 2008
Resolution: Rcvd fax report, deficiency was identified and corrected during vessel''s dry dock in Singapore (3 March 08 to 27 March 08).
Engineering › Steam Boiler (auxiliary/waste heat) › Chemical Feed
Issued 24 January 2008
Resolved
Vessel has erected a plastic bucket to mix chemicals and freshwater for boiler feed pumps, complete with a fresh water line welded from fresh water pipe. Make permanent and better means to safely transport chemicals and fresh water to pumps within 45 days to the satisfaction of Class.
Action required: 705 - Other - as specified
Due 8 March 2008
Resolved 9 March 2008
Resolution: Rcvd fax report, deficiency was identified and corrected during vessel''s dry dock in Singapore (3 March 08 to 27 March 08).
Engineering › Freshwater Generation System › Piping
Issued 23 May 2007
Resolved
While conducting a walk through of the Engine Room it was noticed that the Fresh Water Generator was excessively corroded around it's flanges and piping. Additionally there were multiple soft patches on the piping and fittings. The vessel is to make permanent repairs or obtain a Condition of Class.
Action required: 705 - Other - as specified
Due 23 June 2007
Resolved 12 July 2007
Resolution: Received Class Report #MMI0740125 from attending Lloyds Surveyor. Report of Survey stated that all related pipework and fittings have been renewed. The system was pressure tested and found satisfactory.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 9 July 2006
Resolved
Drain line for OWS has been repaired by a fiberglass wrap. Prior to next US Port, after going foreign, make proper repairs to the satisfaction of Class.
Action required: 705 - Other - as specified
Resolved 1 August 2006
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 9 July 2006
Resolved
Ships engineers using Formazine to calibrate the Oil Content Meter (OCM Model FOCUS 1500A). Ships managers are aware that Formazine may not be an acceptable to calibrate (See email dated 23 April 2005). Prior to the ships return to the US after sailing foreign, provide proof from both Class and the manufacture of the OCM, that Formazine is acceptable or provide proof of other acceptable means
Action required: 705 - Other - as specified
Resolved 11 September 2006
Resolution: Received electronic confirmation from managers with attachment from Lloyd''s Register #GZU0620182, showing that OCM has been replaced.
Fire Fighting › Means of Escape › Doorways
Issued 4 April 2006
Resolved
Bridge doors are padlocked, preventing means of escape
SOLAS II-2 13.3.3.1
Action required: 15 - Rectify deficiencies by next port
Resolved 9 July 2006
Fire Fighting › Emergency Fire Pumps
Issued 27 April 2004
Resolved
The Emergency Fire Pump is unable to prime its own suction, it must be manually primed by one of the crew. LEGACY COMPONENT DESC: Pressure
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 April 2004
Resolved 28 April 2004
Resolution: A condition of class has been issued to have a crew member manually prime the Emergency Fire Pump until proper suction is obtained under an emergency situation. Permanent repairs shall be conducted at the ship''''s next port-Rotterdam.
Fire Fighting › Fire Pumps › Pumpshaft
Issued 27 April 2004
Resolved
The coupling between the motor and the shaft is wasted, therefore rendering the #2 fire pump inoperable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 April 2004
Resolved 28 April 2004
Resolution: The coupling was renewed, and the #2 fire pump was tested to the satisfaction of class.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 27 April 2004
Resolved
The OWS three way valve is frozen, and stuck in the open position, therefore rendering the OWS inoperable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 April 2004
Resolved 28 April 2004
Resolution: The OWS three way valve was overhauled, and the seal ring was renewed. The OWS was tested to the satisfaction of class.