MAURY USCG vessel records Sign in
← All vessels

APL AMAZONITE

APL AMAZONITE is a 1992 freight ship. The Coast Guard has recorded 28 inspections since 1997, most recently in April 2008, along with 9 deficiencies and 2 operational controls.

Records from 1997 to 2008. Most recent: inspection, 9 April 2008.

Built
1992
Last inspected
9 April 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9007958 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
387419
Flag
SINGAPORE
—
Maury page id
psix-387419

Inspections, by type

…with no type recorded13
Years with a record 9 calendar years (1997–2008)
The 28 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it49716 - Convention (Subpart B), Gross Ton
49716 - Regulatory (Subpart C or D), Gross Ton
20645 - Convention (Subpart B), Net Ton
59604 - Dead Weight, Ton
78315 - Displacement, Ton
20645 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CAP SAN RAPHAEL Freight Ship · MISLE 562281 · 31 May 2002 · activity 1628765

Inspection history · 28

9 April 2008 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3180426
24 January 2008 Random ISPS/MTSA/PSC · MARPOL Annex V Examination · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3135375
6 December 2007 Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 3110909
12 July 2007 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2992631
26 May 2007 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2946207
23 May 2007 Ballast Water Examination · MARPOL Annex V Examination · ISPS II Exam · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2938013
11 September 2006 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2775561
1 August 2006 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2732887
12 July 2006 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2710480
9 July 2006 MARPOL Annex I Examination · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2706339
4 April 2006 Random ISPS/MTSA/PSC
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2616170
15 February 2006 Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 2585569
2 August 2005 ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2448459
19 May 2004 MARPOL Annex I Examination · MTSA/ISPS Verification · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2071892
27 April 2004 Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2053659
27 April 2004 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2058128
26 April 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2052693
24 April 2004 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2051637
12 March 2004 MTSA/ISPS Verification
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2023290
5 December 2003 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1966069
4 December 2003 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1962645
15 April 2003 Annual Inspection · Ballast Water Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1774278
31 May 2002 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1628765
18 March 2002 Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1494325
13 February 2002 Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1486304
12 December 2001 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 296110
19 September 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1071614
15 October 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 408979

Deficiency record · 9

Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 24 January 2008 Resolved
Vessel's Main Engine #5 and #9 Jacket Lines are leaking down on both sides of engine due to cold temperature, which results in the bilge level alarm to activate. Make permanent repairs within 45 days to the satisfaction of Class.
Action required: 705 - Other - as specified
Due 8 March 2008
Resolved 9 March 2008
Resolution: Rcvd fax report, deficiency was identified and corrected during vessel''s dry dock in Singapore (3 March 08 to 27 March 08).
Engineering › Steam Boiler (auxiliary/waste heat) › Chemical Feed
Issued 24 January 2008 Resolved
Vessel has erected a plastic bucket to mix chemicals and freshwater for boiler feed pumps, complete with a fresh water line welded from fresh water pipe. Make permanent and better means to safely transport chemicals and fresh water to pumps within 45 days to the satisfaction of Class.
Action required: 705 - Other - as specified
Due 8 March 2008
Resolved 9 March 2008
Resolution: Rcvd fax report, deficiency was identified and corrected during vessel''s dry dock in Singapore (3 March 08 to 27 March 08).
Engineering › Freshwater Generation System › Piping
Issued 23 May 2007 Resolved
While conducting a walk through of the Engine Room it was noticed that the Fresh Water Generator was excessively corroded around it's flanges and piping. Additionally there were multiple soft patches on the piping and fittings. The vessel is to make permanent repairs or obtain a Condition of Class.
Action required: 705 - Other - as specified
Due 23 June 2007
Resolved 12 July 2007
Resolution: Received Class Report #MMI0740125 from attending Lloyds Surveyor. Report of Survey stated that all related pipework and fittings have been renewed. The system was pressure tested and found satisfactory.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 9 July 2006 Resolved
Drain line for OWS has been repaired by a fiberglass wrap. Prior to next US Port, after going foreign, make proper repairs to the satisfaction of Class.
Action required: 705 - Other - as specified
Resolved 1 August 2006
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 9 July 2006 Resolved
Ships engineers using Formazine to calibrate the Oil Content Meter (OCM Model FOCUS 1500A). Ships managers are aware that Formazine may not be an acceptable to calibrate (See email dated 23 April 2005). Prior to the ships return to the US after sailing foreign, provide proof from both Class and the manufacture of the OCM, that Formazine is acceptable or provide proof of other acceptable means
Action required: 705 - Other - as specified
Resolved 11 September 2006
Resolution: Received electronic confirmation from managers with attachment from Lloyd''s Register #GZU0620182, showing that OCM has been replaced.
Fire Fighting › Means of Escape › Doorways
Issued 4 April 2006 Resolved
Bridge doors are padlocked, preventing means of escape SOLAS II-2 13.3.3.1
Action required: 15 - Rectify deficiencies by next port
Resolved 9 July 2006
Fire Fighting › Emergency Fire Pumps
Issued 27 April 2004 Resolved
The Emergency Fire Pump is unable to prime its own suction, it must be manually primed by one of the crew. LEGACY COMPONENT DESC: Pressure
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 April 2004
Resolved 28 April 2004
Resolution: A condition of class has been issued to have a crew member manually prime the Emergency Fire Pump until proper suction is obtained under an emergency situation. Permanent repairs shall be conducted at the ship''''s next port-Rotterdam.
Fire Fighting › Fire Pumps › Pumpshaft
Issued 27 April 2004 Resolved
The coupling between the motor and the shaft is wasted, therefore rendering the #2 fire pump inoperable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 April 2004
Resolved 28 April 2004
Resolution: The coupling was renewed, and the #2 fire pump was tested to the satisfaction of class.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 27 April 2004 Resolved
The OWS three way valve is frozen, and stuck in the open position, therefore rendering the OWS inoperable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 April 2004
Resolved 28 April 2004
Resolution: The OWS three way valve was overhauled, and the seal ring was renewed. The OWS was tested to the satisfaction of class.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.