None recorded without a removal date

Identity

7803815 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
387455
Flag
RUSSIA
—
Maury page id
psix-387455

Inspections, by type

…with no type recorded4
Years with a record 4 calendar years (1995–2004)
The 9 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 22 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it12363 - Convention (Subpart B), Gross Ton
4065 - Convention (Subpart B), Net Ton
9606 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 9

18 May 2004 Damage Survey
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2073172
17 May 2004 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2107094
20 February 2004 Deficiency Check · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2009813
26 September 2003 Re-Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1913908
24 June 2003 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1825494
18 June 2003 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1820949
17 December 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 398488
16 December 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 142934
19 December 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 385883

Deficiency record · 24

Engineering › Diesel Engine (propulsion-direct drive)
Issued 18 May 2004 Resolved
Main Engine stall in transit out of Pascagoula harbor. Vessel must make repair and have class verify Safety Construction Cert. before departure.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 May 2004
Resolution: Engine repairs carried out under the supervision of ABS surveyors [name withheld] and Carlissa D. Wiley.
Lifesaving › Lifeboat
Issued 26 September 2003 Resolved
Exhaust leaks from port and starboard lifeboat engines to be repaired to the satisfaction attending CG inspector prior to re-entry into next U.S. port. Excessive exhaust manifold leaks make lifeboat usability questionable. Solas allships . Solas 60/I/REG10. LEGACY COMPONENT DESC: Exhaust Pipe
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 19 February 2004
Resolution: No Leaks detected. Ran both lifeboat engines, all sat.
Construction/Loadline › Structures
Issued 26 September 2003 Resolved
Port lifeboat embarkation walkway members to be repaired as new including missing strake prior to re-entry into next U.S. Port. ILLC 66 Annex I/15 LEGACY COMPONENT DESC: Deck Plating
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 19 February 2004
Resolution: Embarkation walks in working condition, capable of safe and proper service.
Navigation
Issued 18 June 2003 Resolved
DID NOT HAVE A COPY OF INLAND RULES OF THE ROAD. 33 CFR 164.30 LEGACY COMPONENT DESC: INLAND RULE OF THE ROAD
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 June 2003
Resolution: Verified that vessel has received a copy of Inland rules of the road.
Engineering › Sea-water System (primary cooling)
Issued 18 June 2003 Resolved
VESSEL TO REPLACE GLANDS ON STARBOARD SIDE SALT WATER PUMP WHICH IS LEAKING. REPLACE TO THE SATISFACTION OF FLAG STATE REP AND US COAST GUARD. SOLAS 60 REG 21. LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Due 2 July 2003
Resolved 26 September 2003
Resolution: Received RMRS# 772240 dated 7/25/03 by class surveyor V. Kirejev O. Serdyuk attesting to satifactory repairs.
Engineering › Sea-water System (primary cooling)
Issued 18 June 2003 Resolved
VESSEL TO REPAIR GATE VALVE FROM SECONDARY SEA CHEST TO STARBOARD SIDE SALT WATER PUMP WHICH IS LEAKING. REPLACE TO THE SATISFACTION OF FLAG STATE REP AND USCG. SOLAS 60 REG 21. LEGACY COMPONENT DESC: Sea Chest
Condition: Improper/Lack of Maintenance
Due 2 July 2003
Resolved 26 September 2003
Resolution: Received RMRS# 772240 dated 7/25/03 by class surveyor V. Kirejev O. Serdyuk attesting to satisfactory repairs.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 18 June 2003 Resolved
REPAIR WATER LEAKS COMING FROM MAIN ENGINE CYLINDERS TO THE SATISFACTION OF FLAG STATE REP AND USCG. SOLAS 60 REG 21. LEGACY COMPONENT DESC: Cylinder Head
Condition: Unknown
Due 26 September 2003
Resolved 26 September 2003
Resolution: Received RMRS# 772240 dated 7/25/03 by class surveyor V. Kirejev O. Serdyuk attesting to satisfactory repairs.
Engineering
Issued 18 June 2003 Resolved
NOTED EXCESSIVE LEAKING FROM DETERIORATED PIPING FROM ELECTRICAL BOILER LEADING OUT OF ENGINE ROOM. REPLACE PIPING TO THE SATISFACTION OF FLAG STATE REP AND USCG. SOLAS 60 REG 21.
Due 2 July 2003
Resolved 26 September 2003
Resolution: Received RMRS# 772240, dated 7/25/03 by class surveyor V. Kirejev o. Serdyuk attesting to satisfactory repairs.
Engineering › Shafting/Propeller Arrangements
Issued 18 June 2003 Resolved
REPAIR LEAK IN PIPE FITTINGS ON SHAFT. REPAIR TO THE SATISFACTION OF FLAG STATE REP AND USCG. SOLAS 60 REG 9
Condition: Unknown
Due 2 July 2003
Resolved 26 September 2003
Resolution: Received RMRS# 772240, dated 7/25/03 by class surveyor V. Kirejev O. Serdyuk attesting to staisfactory repairs.
Electrical › Electric Generation Source (emergency)
Issued 18 June 2003 Resolved
MUST REPAIR LEAKS ON EMERGENCY GENERATOR TO SATISFACTION TO FLAG STATE REP AND USCG. SOLAS 60 REG 60
Condition: Unknown
Due 2 July 2003
Resolved 26 September 2003
Resolution: Received RMRS# 772240, dated 7/25/03 by class surveyor V. Kirejev O. Serdyuk attesting to satisfactory repairs.
Lifesaving › Lifeboat
Issued 18 June 2003 Resolved
PORT SIDE LIFEBOAT DID NOT START. MUST REPAIR TO THE SATISFACTION OF THE USCG. SOLAS 60 III/8 (b)(c). LEGACY COMPONENT DESC: Propulsion Starting System
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 June 2003
Resolution: Port side lifeboat started and run to satisfaction of USCG.
Lifesaving
Issued 17 December 1996 Resolved
Make permanent repairs to the hole located on the lower port side of the port lifeboat._x001C_ See SOLAS 74 (Amended) III/19.2_x001C_ _x001C_
Condition: Unknown
Due 20 December 1996
Resolved 23 December 1996
Lifesaving
Issued 17 December 1996 Resolved
Repair the exhaust leak located on the starboard lifeboat._x001C_ See SOLAS 74 (Amended) III/19.2
Condition: Unknown
Due 20 December 1996
Resolved 23 December 1996
Lifesaving
Issued 17 December 1996 Resolved
Provide 45 additional liters of water for each lifeboat._x001C_ See SOLAS 60 III/11_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 December 1996
Resolved 23 December 1996
Lifesaving
Issued 17 December 1996 Resolved
Renew retro-reflective tape on all lifejackets._x001C_ See SOLAS 74 (Amended) III/30.2.7_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 January 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 17 December 1996 Resolved
Renew as original the deteriorated sea water piping located on the supply and discharge side of the auxiliary sea water pump located on the starboardside lower level of the engine room._x001C_ See SOLAS 74 (Amended) I/11(a)_x001C_
Condition: Unknown
Due 4 January 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 17 December 1996 Resolved
Install on the port and starboard bridge wings a quick release mechanism for the ring buoys, self-igniting smoke, and self-activating light._x001C_ See SOLAS 60 III/21(g)_x001C_ _x001C_
Condition: Unknown
Due 20 December 1996
Resolved 23 December 1996
Documentation
Issued 19 December 1995 Resolved
PROVIDE ONBOARD LIFESAVING APPLIANCE TRAINING MANUAL._x001C_ _x001C_ _x001C_ SOLAS 74/78 REG.51
Condition: Unknown
Due 18 December 1996
Resolved 18 December 1996
Fire Fighting
Issued 19 December 1995 Resolved
RENEW BROKEN FIREMAIN PIPING SUPPORTS ON PORT and STARBORD SIDE MAIN DECK.
Condition: Unknown
Due 29 December 1995
Resolved 9 January 1996
Electrical
Issued 19 December 1995 Resolved
MAKE ELECTRICAL CONNECTIONS ON FUEL OIL PURIFERS MOUNT OR SECURE ELECTRICALJUNCTION BOX LOCATED AT FOREWARD PURIFIER TO SATISFACTION OF CLASS. PROVIDECLASS REPORT._x001C_ SOLAS 60,II-26
Condition: Unknown
Due 29 December 1995
Resolved 9 January 1996
Electrical
Issued 19 December 1995 Resolved
MAKE LIGHT IN PAINT LOCKER EXPLOSIVE PROOF_x001C_ _x001C_ _x001C_ SOLAS 60,II-26
Condition: Unknown
Due 19 December 1995
Resolved 9 January 1996
Lifesaving
Issued 19 December 1995 Resolved
RENEW LIFELINES BECKETED AQROUND OUTSIDE OF STARBOARD SIDE LIFEBOAT._x001C_ PROVIDE CLASS REPORT._x001C_ _x001C_ SOLAS, 60 III REG.7
Condition: Unknown
Due 29 December 1995
Resolved 31 December 1995
Documentation
Issued 19 December 1995 Resolved
DEMONSTRATE THAT VESSEL IS IN COMPLIANCE WITH STATURORY REQUIREMENTS OF_x001C_ SOLAS,MARPOL,LOADLINE. PROVIDE COPIES OF IOPP,LOADLINE,SLC,SLR, CLASSIFICATION DOCUMENT TO COASTGUARD PRIOR TO DEPARTURE._x001C_ SOLAS 60,I REG 12
Condition: Unknown
Due 29 December 1995
Resolved 31 December 1995
Fire Fighting
Issued 19 December 1995 Resolved
PROVIDE FIXED FIRE FIGHTING SYSTEM PROTECTION FOR PAINT LOCKER TO SATISFACTION OF CLASS SOCIETY. PROVIDE CLASS REPORT TO LOCAL COAST GUARD._x001C_ PROVIDE PORTABLE EXTINGUISHER OUTSIDE OF LOCKER IN INTERIM PERIOD
Condition: Unknown
Due 19 January 1996
Resolved 31 December 1995