Records from 2005 to 2026. Most recent: inspection, 2 March 2026.
Inspection history · 18
2 March 2026
Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8295227
29 May 2025
COI Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8139850
15 August 2024
Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7975765
19 March 2024
Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7881596
3 August 2023
Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7738858
29 August 2022
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7547815
7 March 2022
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7407044
19 July 2021
Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7258845
28 May 2020
COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6962416
22 April 2020
Deadweight Survey · Plan Review "T" Boat
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6972050
21 February 2020
Internal Structural Exam · Deficiency Check · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6917005
25 September 2019
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6820679
19 June 2019
Drydock Exam · Deficiency Check · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6719444
19 June 2019
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6723650
29 November 2018
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6589218
7 August 2017
COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6232995
21 February 2017
Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6092445
7 November 2016
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6041379
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 August 2024
Resolved
Vessel's COI is listed with required portable fire extinguishing equipment. 01 portable fire extinguisher 80 B:C found partially discharged. Vessel required a 2:A or larger portable fire extinguisher. 46CFR181.30-1
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2024
Resolved 16 August 2024
Resolution: O/O replaced partially used portable fire extinguisher with a new 4A, 80B:C and placed in service on the vsl.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 August 2022
Resolved
An adult life jacket must be provided for each person. Veseel has 80 adult life jackets and is required to have 81 as per COI. Vessel limited to 80 persons on board until additional life jacket is placed in service. 46 CFR 180.71
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2022
Resolved 1 September 2022
Resolution: MI verified additional lifejacket put in service on vessel.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 29 August 2022
Resolved
Each vessel that operated on the high seas must have an EPIRB installed to automatically float free and activate. Vessel's hydrostatic release is expired. Restricted to operating within 3 miles of shore until replacement hydrostatic release unit for the EPIRB has been installed and inspected. 46 CFR 180.64
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2022
Resolved 1 September 2022
Resolution: MI verified new hydrostatic release for the vessel's EPIRB purchased and put into service on vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 July 2021
Resolved
All vessels shall be provided with an approved adult type life preserver for each person carried. Vessel is authorized a total of 78 passengers and three crew. Vessel is currently equipped with 77 adult life jackets. Vessel's passenger count is limited to 74 adult passengers until four new adult life preserves have been placed on board the vessel to the satisfaction of the attending marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 August 2021
Resolved 30 September 2021
Resolution: Verified presence of 04 additional adult life jackets on board vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 October 2019
Resolved
Connections must be made to battery terminals with permanent type connectors. Battery connections are loose.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 November 2019
Resolved 11 October 2019
Resolution: Installed lock washers
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 October 2019
Resolved
Batteries must be secured to protect against shifting. Need straps for battery boxes, not secured.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 November 2019
Resolved 11 October 2019
Resolution: Installed battery straps
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 October 2019
Resolved
This part is intended to provide a minimum standard of regulations for electrical installations and equipment that will result in a vessel that is reasonably safe from fire caused by and/or originating from electrical equipment. Port engine has exposed wiring from insulation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 November 2019
Resolved 11 October 2019
Resolution: cut and spliced chaffed wire
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 October 2019
Resolved
A vessel not required to have a power driven fire pump must have at least three 9.5 liter (2 1/2 gallon) buckets, with attached lanyard. Missing one 2 1/2 gallon bucket.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2019
Resolved 23 October 2019
Resolution: Replaced fire bucket
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 October 2019
Resolved
At least one ring life buoy must be fitted with a lifeline. Missing the lifeline.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2019
Resolved 28 May 2020
Resolution: Verified lifeline is provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 October 2019
Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 3 feet in length but not more than 6 feet. Lanyard too long.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2019
Resolved 28 May 2020
Resolution: Verified line for floating waterlight is correct length.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 October 2019
Resolved
Each portable fire extinguisher on a vessel must be of an approved type. Each extinguisher needs proper bracket for their mounts.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 November 2019
Resolved 28 May 2020
Resolution: Verified fire extinguishers are provided with approved brackets.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 October 2019
Resolved
Connections must be made to battery terminals with permanent type connects. Wing nuts are not permanent type.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 November 2019
Resolved 23 October 2019
Resolution: Replaced wing nuts
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 October 2019
Resolved
Life ring buoys ust be approved in accordance with 46 CFR 160.50. Ring buoy needs new retro reflective tape (aft buoy). Provide proper mounting for ring buoys.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 November 2019
Resolved 28 May 2020
Resolution: Verified ring buoy is provided with a proper bracket.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 October 2019
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personal injury. Fuel pump leaking.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 23 October 2019
Resolved 11 October 2019
Resolution: Replaced leaking fuel pump. below third party conducted repair.
Quickie Marine & Fiberglass Repair
1723 Signal Point Road Unit C
SC 29412 US
[phone withheld]
[email withheld]
www.quickboatservice.com
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 November 2018
Resolved
Place in service nine (9) USCG approved Type I PFDs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 December 2018
Resolved 4 December 2018
Resolution: Nine USCG Type I PFDs were placed in service.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 29 November 2018
Resolved
Replace expired medications.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 December 2018
Resolved 4 December 2018
Resolution: New medications were purchased and placed in service.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 November 2018
Resolved
Show proper operation of the port running light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 December 2018
Resolved 4 December 2018
Resolution: Port light was replaced.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 29 November 2018
Resolved
Provide current nautical chart for operating area.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 December 2018
Resolved 4 December 2018
Resolution: A current chart was purchased and placed in service.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 7 August 2017
Resolved
Place in service 23 Adult size Type-I USCG approved PFDs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 September 2017
Resolved 28 August 2017
Resolution: Vessel owner purchased and placed in service 23 USCG approved Adult Type-I PFDs.
Navigation › Piloting/Steering › Gyro Compass
Issued 7 November 2016
Resolved
Compass light extinguished
Due 22 November 2016
Resolved 14 November 2016
Resolution: Replace light
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 7 November 2016
Resolved
Line wasted
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 November 2016
Resolved 14 November 2016
Resolution: Replaced lifeline
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 7 November 2016
Resolved
Reflective tape worn
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 November 2016
Resolution: Replaced tape
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 7 November 2016
Resolved
14 Lifejackets needed reflective tape
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 November 2016
Resolution: Replaced lifejackets
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 7 November 2016
Resolved
10 lifejackets torn/wasted
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 November 2016
Resolution: Replaced lifejackets
Unknown
Issued 7 November 2016
Resolved
Outdated first aid kit
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 November 2016
Resolution: New first aid kit installed