MAURY USCG vessel records Sign in
← All vessels

FOLEGANDROS

FOLEGANDROS is a 1992 tank ship. The Coast Guard has recorded 40 inspections since 1993, most recently in February 2010, along with 5 deficiencies and 6 operational controls, 2 with no removal date recorded.

Records from 1993 to 2010. Most recent: inspection, 18 February 2010.

Built
1992
Last inspected
18 February 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
2 with no removal date recorded

Identity

8917467 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
387706
Flag
GREECE
—
Maury page id
psix-387706

Inspections, by type

…with no type recorded24
Years with a record 17 calendar years (1993–2010)
The 40 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it29506 - Simplified, Gross Ton
29506 - Convention (Subpart B), Gross Ton
11650 - Simplified, Net Ton
11650 - Convention (Subpart B), Net Ton
55345 - Displacement, Ton
45425 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SEBAROK SPIRIT Tank Ship · MISLE 392334 · 7 July 2003 · activity 1838170GT INDEPENDENCE Tank Ship · MISLE 482386 · 7 July 2003 · activity 1838170AMAZON EXPLORER Tank Ship · MISLE 586914 · 7 July 2003 · activity 1838170B.F.T. NO. 38 Tank Barge · MISLE 53105 · 18 April 1994 · activity 447093

Inspection history · 40

18 February 2010 Ballast Water Examination · ISPS II Exam · COC-TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3681696
13 February 2010 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3679527
12 July 2009 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3532273
13 January 2009 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3393347
9 January 2009 ISPS II Exam · MARPOL Annex V Examination · MARPOL Annex I Examination · PII Safety Exam · COC-TVE Renew · Ballast Water Examination · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3388953
7 January 2008 ISPS II Exam · COC-TVE Annual · MARPOL Annex I Examination · MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex II Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3124794
14 May 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2930369
20 February 2007 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2874587
1 January 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2848741
13 June 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2678645
7 June 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2673534
15 November 2005 COC-TVE Annual · ISPS II Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2533665
18 February 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2295550
18 February 2005 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2295610
17 October 2004 ISPS III Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2220131
17 June 2004 MTSA/ISPS Verification · NPV Safety Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2101857
14 May 2004 MTSA/ISPS Verification
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2064718
19 April 2004 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2047845
3 April 2004 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2037746
31 March 2004 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2131296
24 July 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1859521
7 July 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1838170
3 July 2003 Ballast Water Examination · Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1834132
20 June 2002 Certificate of Compliance · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1633992
17 September 2001 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1480494
29 May 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 290549
23 March 2000 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 275848
23 March 2000 Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 818337
11 July 1998 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 417966
15 October 1997 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 408866
30 June 1997 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 405113
31 May 1997 Type not recorded
No type recorded · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 524823
4 June 1996 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 391672
25 March 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 389350
29 May 1995 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 378793
13 March 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 376143
18 April 1994 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 447093
18 April 1994 Tank Vessel Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 856810
9 September 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 360813
22 April 1993 MARPOL Annex I Examination · Certificate of Compliance
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1148765

Deficiency record · 5

Engineering › Sea-water System (primary cooling) › Piping
Issued 9 January 2009 Resolved
#3 generator salt water cooling line has temporary fiberglass patch. Make repairs to original condition to satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 January 2009
Resolution: Vessel provided classification survey report to USCG on 1/11/2009 correcting the issued deficiency. Lube Oil Cooler Salt Water line has been replaced by a new one.
Lifesaving › Emergency Outfit › Breathing Apparatus
Issued 9 January 2009 Resolved
EEBD in cargo pump room was out of service/calibration. Service, Recalibrate or Replace this EEBD.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 January 2009
Resolution: EEBD was serviced by Unitor representative while inspection team was on board. EEBD found to be satisfactory.
Deck/Cargo
Issued 29 May 2001 Resolved
Vessel could not demonstrate operation of "loss of power" alarm for cargo tank overfill alarms.
Condition: Unknown
Due 8 June 2001
Resolved 8 June 2001
Engineering
Issued 29 May 2001 Resolved
Main engine #1 cylinder has minor cooling water leak.
Condition: Unknown
Due 8 June 2001
Resolved 8 June 2001
Documentation
Issued 23 March 2000 Resolved
PAINT STOWED IN FORECASTLE BOSIN STORES, SPACE DOES HAVE WATER SPRAY AND EXPLOSION PROOF FIXTURIES BUT NOT LABLED ON THE FIRE PLAN. VESSEL TO HAVE CLASS APPROVE SPACE FOR STOWAGE OF PAINT AND CORRECT FIRE CONTROL PLAN.
Condition: Unknown
Due 20 April 2000
Resolved 20 April 2000

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.