Records from 1993 to 2010. Most recent: inspection, 6 December 2010.
Inspection history · 39
6 December 2010
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3899340
8 July 2008
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3251192
11 October 2007
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3077631
17 January 2007
MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2857163
28 August 2006
ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2761759
12 December 2005
Ballast Water Examination · PII Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2549840
26 September 2005
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2501566
15 June 2005
Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2391157
7 April 2005
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2328696
16 March 2005
ISPS II Exam
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2311498
16 March 2005
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2311983
3 March 2005
Ballast Water Examination · PII Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2302599
27 September 2004
ISPS II Exam
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2206771
5 January 2004
Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1975615
20 October 2003
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1932428
14 June 2003
Special Interest Vessel
Type not classified · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1817026
28 March 2003
Re-Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1764503
27 March 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1764129
25 March 2003
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1762666
25 March 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1762897
10 January 2003
Ballast Water Examination · Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1728691
13 December 2002
Deficiency Check · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1718405
6 September 2002
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1672044
9 August 2002
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1658590
7 January 2002
Passenger/Freight Vessel Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1476185
31 May 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 290181
9 October 2000
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 283562
16 December 1999
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 435856
10 December 1999
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 436163
17 June 1999
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 429689
14 October 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 421261
6 March 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 509093
30 January 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 400044
7 June 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 391914
14 February 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 715929
23 January 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 387141
26 April 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 537965
15 October 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 477248
27 April 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 455224
Lifesaving › Launching Appliances › Winch Brake
Issued 9 March 2005
Resolved
Class Society survyer to attest to proper operation of the launching arrangment of the port and stbd lifeboats. When tested the port lifeboat dead man break did not work properly and one of the fwd sheaves did not rotate.
Action required: 705 - Other - as specified
Due 23 March 2005
Resolved 7 April 2005
Resolution: Received classification survey report attesting to repairs.
Engineering › Generator (propulsion-electric)
Issued 15 October 2003
Resolved
All ships service generators have duct tape and plastic wrap temporary gaskets on the turbocharger scavaging air intake piping.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 November 2003
Resolved 3 January 2004
Resolution: Received Class report attesting to satisfactory repairs to ship service generators.
Fire Fighting › Fire Pumps
Issued 15 October 2003
Resolved
Main fire pump foundation bolts and shaft packing are loose, causing excessive water leakage. Solas 74 (unammended) II-2/5 LEGACY COMPONENT DESC: Gland Sealing
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 November 2003
Resolved 3 January 2004
Resolution: Received Class report attesting to satisfactory repairs to aft shiv guide on port side lifeboat davit.
Lifesaving › Lifeboat
Issued 15 October 2003
Resolved
Port and Starboard lifeboats are extremely waterlogged. Fiberglass is soft and blistered. Solas 74 (unammended) III/5 LEGACY COMPONENT DESC: Hull
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 November 2003
Resolved 3 January 2004
Resolution: Received Class report attesting to satisfactory repairs to port and starboard lifeboat fiberglass.
Lifesaving › Launching Appliances
Issued 15 October 2003
Resolved
Aft shiv guide on port side aft lifeboat davit is damaged and misaligned. Solas 74 (unamended) III/36 LEGACY COMPONENT DESC: Davit
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 November 2003
Resolved 3 January 2004
Resolution: Received Class report attesting to satisfactory repairs to main fire pump foundation and shaft packing.
Engineering › Freshwater Generation System
Issued 9 August 2002
Resolved
Make permanent repairs to the wasted and holed salt water feed line to the evaporator, stbd side, forward, bottom deck of the engine room to the satisfaction of class prior to 09Sep02. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 September 2002
Resolved 12 December 2002
Resolution: CORRECTED VIA CLASS REPORT.
Engineering
Issued 10 December 1999
Resolved
REPAIR PORT SIDE HEAVY FUEL OIL PUMP AS ORIGINAL.
Condition: Unknown
Due 2 November 2000
Resolved 2 November 2000
Engineering
Issued 10 December 1999
Resolved
CLEAN COALESORS ON OILY WATER SEPERATOR.
Condition: Unknown
Due 2 November 2000
Resolved 2 November 2000
Construction/Loadline
Issued 10 December 1999
Resolved
CLEAN ENGINE ROOM BILGES AND BULKHEADS OF EXCESS OILY WASTE AND PUMP TO HOLDING TANK.
Condition: Unknown
Due 2 November 2000
Resolved 2 November 2000
Documentation
Issued 14 October 1998
Resolved
PROVIDE ON BOARD STCW ENDORSEMENTS BY FLAG STATE FOR ALL OFFICERS LICENSES.STCW 78 II/2
Condition: Unknown
Due 19 November 1998
Resolved 20 October 1998
Construction/Loadline
Issued 14 October 1998
Resolved
RENEW/REPAIR ALL DETERIORATED/SEIZED WATERTIGHT DOORS THROUGHOUT VESSEL._x001C_ ILLC 66 ANNEX 1/12
Condition: Unknown
Due 19 November 1998
Resolved 20 October 1998
Lifesaving
Issued 30 January 1997
Resolved
MAKE PERMANENT REPAIRS TO GALLEY REEFER INTERIOR DOOR HANDLES. (ILO 147)
Condition: Unknown
Due 4 February 1997
Resolved 20 February 1997
Lifesaving
Issued 30 January 1997
Resolved
PROVE PROPER OPERATION OF PORT AND STARBOARD LIFEBOAT DAVIT LIMIT SWITCHES.(SOLAS 74 (UNAMENDED), CH. III, REG. 36(k)._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 January 1997
Resolved 31 January 1997
Lifesaving
Issued 30 January 1997
Resolved
MASTER UNABLE TO PERFORM SHIPBOARD SAFETY PROCEDURES._x001C_ (SOLAS (AMENDED), CH. XI., REG. 4)_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 February 1997
Resolved 20 February 1997
Lifesaving
Issued 30 January 1997
Resolved
GALLEY REEFER ALARMS INOPERABLE. (ILO 147)_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 February 1997
Resolved 20 February 1997
Lifesaving
Issued 23 January 1996
Resolved
VERIFY PRESENCE/CONDITION OF FIREBOATS (4 EACH) AND EQUIPMENT TO EACH LIFEBOAT IN ACCORDANCE WITH SOLAS 74 (AMENDED) III.41.8
Condition: Unknown
Due 2 February 1996
Resolved 14 February 1996
Lifesaving
Issued 23 January 1996
Resolved
CONDUCT SATISFACTORY FIRE AND ABANDON SHIP DRILL TO THE SATISFACTION OF THEATTENDING US COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 2 February 1996
Resolved 14 February 1996
Electrical
Issued 23 January 1996
Resolved
SECURE/MOUNT PROPERLY ELECTRICAL BOX PORTSIDE BOAT DECK. SOLAS 60 II/27
Condition: Unknown
Due 2 February 1996
Resolved 14 February 1996
Fire Fighting
Issued 23 January 1996
Resolved
LOCATE AND MOUNT FIRE EXTINGUISHER ON PORT SIDE BOAT DECK IN WAY OF VENTILATION COMPARTMENT HATCH. SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 2 February 1996
Resolved 14 February 1996
Electrical
Issued 23 January 1996
Resolved
PROVE BATTERY START ON EMERGENCY GENERATIOR. GENERATOR WOULD NOT START WITH BATTERY BANK. SOLAS 60 II/26
Condition: Unknown
Due 2 February 1996
Resolved 14 February 1996
Lifesaving
Issued 23 January 1996
Resolved
PROVIDE FOR REVIEW, INSTRUCTIONS FOR ONBOARD MAINTENANCE OF LIFESAVING APPLIANCES IN ACCORDANCE WITH SOLAS 74 (AMENDED) III/19.3/52
Condition: Unknown
Due 31 January 1997
Resolved 31 January 1997
Lifesaving
Issued 23 January 1996
Resolved
PROVE OPERATION OF QUICK RELEASE LIFEBOUYS LOCATED ON PORT AND STARBOARD BRIDGE WINGS. LIFEBOUYSARE OF INSUFFICIENT WEIGHT TO LAUNCH SMOKE SIGNAL CANISTER. SOLAS 74(AMENDED)III/19
Condition: Unknown
Due 2 February 1996
Resolved 14 February 1996
Electrical
Issued 23 January 1996
Resolved
IDENTIFY/CLEAR ELECTRICAL GROUND ON MAIN SWITCH BOARD SECTION 7 AND GROUNDSON THE GENERATOR SWITCH BOARD. SOLAS 60 II/27
Condition: Unknown
Due 2 February 1996
Resolved 14 February 1996
Navigation
Issued 23 January 1996
Resolved
CONDUCT SATISFACTORY STEERING AND EMERGENCY STEERING DRILL TO THE SATISFACTION OF THE ATTENDING US COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 2 February 1996
Resolved 14 February 1996
Fire Fighting
Issued 23 January 1996
Resolved
SECURE/MOUNT FIRE BLANKET CONTAINERS IN ACCORDANCE WITH APPROVED FIRE_x001C_ CONTROL PLAN. SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 2 February 1996
Resolved 14 February 1996
Fire Fighting
Issued 23 January 1996
Resolved
REPAIR/RENEW MOUNTING BRACKET TO FIREMAIN SYSTEM PIPING IN WAY OF #34 HYDRANT. SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 2 February 1996
Resolved 14 February 1996
Navigation
Issued 23 January 1996
Resolved
REPAIR ECHO DEPTH SOUNDING RECORDING DEVICE 33 C.F.R. 164.35(i).
Condition: Unknown
Due 10 June 1996
Resolved 10 June 1996
Fire Fighting
Issued 23 January 1996
Resolved
PROVIDE UPDATED FIRE CONTROL PLAN TO INCLUDE PARTICULARS OF THE FIRE DETECTION AND FIRE ALARM SYSTEM, FIRE SUPPRESSION SYSTEM, THE FIRE EXTINGTUISHING APPLIANCES, INTERNATIONAL SHORETIE CONNECTION AND VENTILATIONS SYSTEMS. SOLAS 74 (AMENDED) II-2/20
Condition: Unknown
Due 10 June 1996
Resolved 10 June 1996
Fire Fighting
Issued 23 January 1996
Resolved
PROVIDE FOR REVIEW, INSTRUCTIONS FOR MAINTENANCE AND OPERATION OF ALL INSTALLATIONS/EQUIPMENT FOR FIRE FIGHTING AND CONTAINMENT OF FIRE IN ACCORDANCE WITH SOLAS 74(AMENDED) II-2/20
Condition: Unknown
Due 10 June 1996
Resolved 10 June 1996
Electrical
Issued 23 January 1996
Resolved
REPLACE/REPAIR MOUNTING BRACKETS FOR LIGHT FIXTURES THROUGHOUT SHIP'S_x001C_ WEATHER DECKS. SEE SOLAS 60/27
Condition: Unknown
Due 10 June 1996
Resolved 10 June 1996
Fire Fighting
Issued 23 January 1996
Resolved
REPAIR/RENEW VENT CLOSURES ON TOP OF #2 DECK HOUSE. SEE SOLAS 60 II/47(A)
Condition: Unknown
Due 10 June 1996
Resolved 10 June 1996
Fire Fighting
Issued 23 January 1996
Resolved
SERVICE ALL SEMI-PORTABLE FOAM FIRE EXTINGUISHERS LOCATED IN ENGINE ROOM. SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 2 February 1996
Resolved 14 February 1996
Fire Fighting
Issued 23 January 1996
Resolved
PROVIDE TO EACH FIRE STATION NECESSARY TOOL TO COUPLE FIRE HOSE WITH NOZZLE/HYDRANT. SEE SOLAS 60 II/56(F)
Condition: Unknown
Due 10 June 1996
Resolved 10 June 1996
Electrical
Issued 23 January 1996
Resolved
RENEW COOLING LINE HOSES TO EMERGENCY GENERATIOR. HOSE COUPLINGS ARE DETERIORATED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 February 1996
Resolved 14 February 1996
Fire Fighting
Issued 23 January 1996
Resolved
SERVICE FIXED CO2 FIRE SUPPRIESSION SYSTEM FOR PAINT LOCKER BY AN AUTHORIZED SERVICING COMPANY TO ENSURE CYLINDER, PIPING AND RELEASE MECHANISM ARE IN GOOD CONDITION AND AVAILABLE FOR IMMEDIATE USE. SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 2 February 1996
Resolved 14 February 1996
Engineering
Issued 23 January 1996
Resolved
REPAIR/RENEW DETERIORATED PIPING TO THE BOILER DAY TANK.
Condition: Unknown
Due 2 February 1996
Resolved 14 February 1996
Electrical
Issued 23 January 1996
Resolved
PROVE OPERATION OF EMERGENCY LIGHTING THROUGHOUT VESSEL. SOLAS 60 III/38
Condition: Unknown
Due 2 February 1996
Resolved 14 February 1996
Fire Fighting
Issued 23 January 1996
Resolved
PROVE OPERATION OF FIREMAIN RELIEF VALVE SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 2 February 1996
Resolved 14 February 1996
Documentation
Issued 23 January 1996
Resolved
PROVID ONBOARD VESSEL VALID LOADLINE CERTIFICATE.
Condition: Unknown
Due 2 February 1996
Resolved 14 February 1996
Navigation
Issued 23 January 1996
Resolved
PROVIDE ONBOARD FOR REVIEW, UP-TO-DATE CHARTS FOR THE GULFPORT, [name withheld]._x001C_ _x001C_
Condition: Unknown
Due 2 February 1996
Resolved 14 February 1996
Documentation
Issued 23 January 1996
Resolved
PROVIDE ONBOARD FOR REVIEW, OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 2 February 1996
Resolved 14 February 1996
Navigation
Issued 23 January 1996
Resolved
PROVIDE ONBOARD FOR REVIEW, NAVIGATIONAL PUBLICATIONS FOR U.S. WATERS AND INTEDED VOYAGE. US COAST PILOT, SAILING DIRECTION, COAST GUARD LIGHT LIST.
Condition: Unknown
Due 2 February 1996
Resolved 14 February 1996
Navigation
Issued 23 January 1996
Resolved
INCLUDE WARNING STATEMENT TO MANEUVERING FACT SHEET POSTED ON BRIDGE.
Condition: Unknown
Due 2 February 1996
Resolved 14 February 1996
Fire Fighting
Issued 23 January 1996
Resolved
REPAIR/REPLACE ISOLATION VALVE TO FIRE MAIN SYSTEM PORT SIDE BOAT DECK IN WAY OF VENTILATION COMPARTMENT. SOLAS 74 (AMENDED) II-2/21_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 February 1996
Resolved 14 February 1996
Electrical
Issued 23 January 1996
Resolved
PROPERLY SECURE BATTERIES IN BATTERY LOCKER AND IN EMERGENCY GENERATIOR ROOM. SOLAS 60 II/27(A)(viii)
Condition: Unknown
Due 2 February 1996
Resolved 14 February 1996
Fire Fighting
Issued 23 January 1996
Resolved
REPAIR/REPLACE DETERIORATED FIRE HOSE STATION BOXES THROUGHOUT VESSEL. SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 2 February 1996
Resolved 14 February 1996
Electrical
Issued 23 January 1996
Resolved
RPLACE/RENEW DEFECTED LIGHTS, PROTECTIVE GLASS SHIELD, METALLIC GUARDS AND BLOWN BULBS TO LIGHT FIXTURES THROUGHOUT VESSEL
Condition: Unknown
Due 2 February 1996
Resolved 14 February 1996
Fire Fighting
Issued 23 January 1996
Resolved
SERVICE ALL PORTABLE EXTINGUISHERS BY AN APPROVED/RECOGNIZED SERVICING FACILITY/COMPANY. NOTED NUMEROUS EXTINGUISHERS THROUGHOUT VESSEL THAT WERENEEDING MAINTENANCE. SOLAS 74(AMENDED) II-2/21
Condition: Unknown
Due 2 February 1996
Resolved 14 February 1996
Lifesaving
Issued 23 January 1996
Resolved
PROVIDE FOR REVIEW TRAINING MANUAL FOR LIFESAVING APPLIANCES. SOLAS 74 (AMENDED) III/183.2/51
Condition: Unknown
Due 2 February 1996
Resolved 14 February 1996
Lifesaving
Issued 23 January 1996
Resolved
REMOVE EXCESS OIL ON DECKS AND IN CONTAINMENTS IN THE FOLLOWING AREAS: HYDRAULIC PUMP ROOMS LOCATED IN DECK HOUSES, STEERING GEAR CONTAINMENT AREA, BOILER FLATS, IN THE VICINITY OF FUEL OIL/LUBE OIL PURIFIERS, DESIGNATED SMOKE ROOM IN DECK HOUSE 3.
Condition: Unknown
Due 2 February 1996
Resolved 14 February 1996
Engineering
Issued 23 January 1996
Resolved
REPAIR/RENEW DETERIORATED SEA WATER COOLING SUPPLY LINE TO MAIN ENGINE. PIPE PRESENTLY HAS A SOFT PATCH.
Condition: Unknown
Due 2 February 1996
Resolved 14 February 1996
Engineering
Issued 23 January 1996
Resolved
PROVE OPERATION OF THE OILY WATER SEPARATING EQUIPMENT. MARPOL 73/78 ANNEXI/16
Condition: Unknown
Due 2 February 1996
Resolved 14 February 1996
Accommodation/Occupational Safety
Issued 23 January 1996
Resolved
RENEW/REPAIR HANDRAILS THROUGHOUT VESSEL. HANDRAILS IN WAY OF RECREATIONALCOURT MISSING. ILL 66 R25
Condition: Unknown
Due 2 February 1996
Resolved 14 February 1996
Accommodation/Occupational Safety
Issued 23 January 1996
Resolved
RENEW/REPAIR AS ORIGHINAL MARINE SANITATION DEVICE. MSD HAS NUMEROUS HOLESIN TANKAND PIPING. BOTH MSD'S HAVE HOLED TANKS.
Condition: Unknown
Due 2 February 1996
Resolved 14 February 1996
Engineering
Issued 23 January 1996
Resolved
REPAIR VENT HEADS STARBOARD SIDE BRIDGE DECK IN WAY OF ENGINE ROOM HATCH.
Condition: Unknown
Due 2 February 1996
Resolved 14 February 1996
Lifesaving
Issued 23 January 1996
Resolved
POST MUSTER LIST AND EMERGENCY INSTRUCTIONS IN ENGINE ROOM. SOLAS 74 (AMENDED) III/8/53
Condition: Unknown
Due 2 February 1996
Resolved 14 February 1996
Lifesaving
Issued 23 January 1996
Resolved
PROVIDE ONBOARD 12 LIFEBOUYS IN ACCORDANCE WITH SAFETY EQUIPMENT CERTIFICATE SIX OF WHICH ARE REQUIRED TO HAVE WATER LIGHTS ATTACHED. SOLAS74 (AMENDED) III/7.1.13
Condition: Unknown
Due 2 February 1996
Resolved 14 February 1996
Lifesaving
Issued 23 January 1996
Resolved
INSTALL RETRO-REFLECTIVE MATERIAL TO ALL LIFEBOATS ONBOARD VESSEL IN ACCORDANCE SOLAS 74 (AMENDED) III/30.2.7
Condition: Unknown
Due 2 February 1996
Resolved 14 February 1996
Lifesaving
Issued 23 January 1996
Resolved
REMOVE ALL LIFESAVING AND FIREFIGHTING EQUIPMENT FROM VESSEL THAT IS UN- SERVICEABLE AND NOT IN WORKING CONDITION. FIRE EXTINGUISHERS LOCATED IN FORECASTLE. SOLAS 74 (AMENDED) II-2/21 / III/19.2
Condition: Unknown
Due 2 February 1996
Resolved 14 February 1996
Fire Fighting
Issued 23 January 1996
Resolved
PROVIDE HANGING BRACKETS FOR PORTABLE FIRE EXTINGUISHERS THROUGHOUT VESSEL.SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 2 February 1996
Resolved 14 February 1996
Fire Fighting
Issued 23 January 1996
Resolved
PROVIDE FIRE HOSE AND APPROVED FIRE NOZZLE TO EACH FIRE STATION THAT ARE INGOOD CONDITION AND AVAILABLE FOR IMMEDIATE USE. SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 2 February 1996
Resolved 14 February 1996
Fire Fighting
Issued 23 January 1996
Resolved
PROVIDE ONBOARD INTERNATIONAL SHORE CONNECTION IN ACCORDANCE WITH SOLAS 74 (AMENDED) II-2/19
Condition: Unknown
Due 2 February 1996
Resolved 14 February 1996