← All vessels
MASTER ENDEAVOUR
MASTER ENDEAVOUR is a 1979 freight ship. The Coast Guard has recorded 6 inspections since 2001, most recently in January 2003, along with 39 deficiencies and 3 operational controls.
Records from 2001 to 2003. Most recent: operational control imposed, 15 January 2003.
- Built
- 1979
- Last inspected
- 15 January 2003
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 39 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7707102 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3EUN7
387836
Flag
PANAMA
—
Maury page id
psix-387836
Inspections, by type
The 6 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 23 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it2580 - Regulatory (Subpart C or D), Gross Ton
1595 - Regulatory (Subpart C or D), Net Ton
4029 - Dead Weight, Ton
1595 - Regulatory (Subpart C or D), Net Ton
4029 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 6
15 January 2003
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1730957
18 December 2002
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1720579
4 November 2002
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1701761
7 August 2002
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1658500
6 December 2001
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 296139
6 December 2001
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1487818
Deficiency record · 39
Pollution Prevention/Response › Prevention Equipment
Issued 4 November 2002
Resolved
Vessel has no written Waste Management Plan. Vessel to provide IAW Marpol/V/9 & 33 CFR 151.57 LEGACY COMPONENT DESC: Garbage/Waste Management Plan
Personnel › Certificates/Documents/Licenses
Issued 4 November 2002
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Pollution Prevention/Response › Prevention Equipment
Issued 4 November 2002
Resolved
SOPEP not approved & dated as such by flag state or designated Rep. Also contact #s are outdated and incorrect. Prior to departure and or Bunkering. MARPOL 73/78/Annex I/Reg 26 LEGACY COMPONENT DESC: SOPEP
Communications › Radio Communications
Issued 4 November 2002
Resolved
Provide evidence of EPIRB Registration and Expiration dates for Battery, & Hydrostatic release.
SOLAS 74 (Amended) IV/1 & V/7. LEGACY COMPONENT DESC: EPIRB
Communications › Radio Communications
Issued 4 November 2002
Resolved
Noted Emergency Battery room and steering to have jumper cble connections. Vessel to provide fixed Connection. Also battery box on top of Pilot house is wasted. Provide new box. Also provide suitable guard & housing for bare bulb and wiring.
SOLAS 60 II/Reg 27. LEGACY COMPONENT DESC: Emergency Source of Power
Lifesaving › Lifeboat
Issued 4 November 2002
Resolved
Noted unsuitable repairs to lifeboats. Wet putty & paint in old grab rail holes, delamination of old fiberglass, no markings. Lifeboats to be properly repaired and float tested in presence of USCG. Also Lifeboat winch foundation/Portside wasted. SOLAS 60/5
SOLAS 74 amended/III/31 LEGACY COMPONENT DESC: Hull
Lifesaving › Hand Flares
Issued 4 November 2002
Resolved
Vessel Missing Safety Distress Equipment (12 Flares, and 1 Line Throwing Gun)
SOLAS 74 Amended III/6.3 LEGACY COMPONENT DESC: Quantity
Accommodation/Occupational Safety › Medical/First Aid
Issued 4 November 2002
Resolved
Vessel does not have a Hospital Space and Suitable Medicine.
ILO 147 LEGACY COMPONENT DESC: Hospital Space
Accommodation/Occupational Safety › Washroom/Toilet
Issued 4 November 2002
Resolved
Vessel does not have hot water.
ILO 147 LEGACY COMPONENT DESC: Hot and Cold Running Water
Communications › Radio Communications
Issued 4 November 2002
Resolved
GMDSS is not Currently Operational. LEGACY COMPONENT DESC: GMDSS
Electrical › Lighting (emergency)
Issued 4 November 2002
Resolved
Emergency lighting is not operational.
SOLAS 60 III/19 (a) LEGACY COMPONENT DESC: Lighting Fixture
Lifesaving › Inflatable Liferafts
Issued 4 November 2002
Resolved
Provide proof Hydrostatic release has been serviced. Expiration dates need to be permanently stamped.
SOLAS 74(amended) III/19.9.1 LEGACY COMPONENT DESC: Hydrostatic Release Unit
Engineering › Sea-water System (primary cooling)
Issued 4 November 2002
Resolved
In Engine Room replace: A )Discharge Pipe for Auxillary S/W pump. B) Replace and blankoff old S/W Sewage supply line.
ICLL 66 Annex I/22 LEGACY COMPONENT DESC: Pump
Engineering › Generator (propulsion-electric)
Issued 4 November 2002
Resolved
Provide machinery guards for rotating machinery on Main Ship Generator & Emergency Fire Pump.
SOLAS 60 II/27
Engineering › Generator (propulsion-electric)
Issued 4 November 2002
Resolved
Provide covers for back of Main Switch Board or means to prevent access.
SOLAS 74(amended) II-1/26.1 LEGACY COMPONENT DESC: Circuit Board
Accommodation/Occupational Safety › Washroom/Toilet
Issued 4 November 2002
Resolved
Noted (2) toilets secured in Port. This leaves only (1) toilet for 10 personnel. Toilets are to be made to not drain directly overboard. Vessel to repair at least one toilet and 2 washbasins.
ILO 147 LEGACY COMPONENT DESC: Number Per Persons
Stability › Watertight Integrity
Issued 4 November 2002
Resolved
Noted main deck watertight hatches for steering, paint locker, & pantry to be wasted and not watertight.
ILLC 66 Annex I/14 LEGACY COMPONENT DESC: Hatches
Accommodation/Occupational Safety › Ventilation
Issued 4 November 2002
Resolved
Provide means of closing down main ventilation for Engine Room. No Dampers noted.
SOLAS 74 II/47 LEGACY COMPONENT DESC: Dampers
Lifesaving › Embarkation Appliances/Stations
Issued 4 November 2002
Resolved
Main Embarkation no longer safe to use. Noted to be wasted and bent.
SOLAS 74/78 V/17 LEGACY COMPONENT DESC: Handholds
Engineering
Issued 4 November 2002
Resolved
Noted Fuel/IFO in Bilges. Remove and provide reciept for disposal. LEGACY COMPONENT DESC: Bilges
Construction/Loadline › Hull
Issued 4 November 2002
Resolved
Provide evidence that Flag/Class has addressed non-standard repair to significant hull compramise on vessel's Starboard Stern Quarter.
ILLC 66 Annex I/1 LEGACY COMPONENT DESC: Transverse Frame
Engineering › Generator (propulsion-electric)
Issued 4 November 2002
Resolved
Make repairs to bring #2 Main Ship Service Generator back in service.
SOLAS 60 I/11
Documentation › Safety Management System
Issued 4 November 2002
Resolved
Observed little evidence of a Safety Management System. Provide proof of Audits, Policy, Written Shipboard documentation, ect....
SOLAS 74/78 IX LEGACY COMPONENT DESC: Safety/Environmental Protection Policy
Engineering
Issued 6 December 2001
Resolved
Vessel to make available fueling stations for inspection.
Engineering
Issued 6 December 2001
Resolved
Vessel to provide proper operation of Generator #3.
Documentation
Issued 6 December 2001
Resolved
Vessel to provide actuall Safe Manning Certificate and complete crew(1st Eng.).
Construction/Loadline
Issued 6 December 2001
Resolved
Vessel to provide proof of ballast water management plan implimented.
Navigation
Issued 6 December 2001
Resolved
Vessel to repair main radar.
Lifesaving
Issued 6 December 2001
Resolved
Vessel to provide new reflective material for all life jackets and new vessel name.
Documentation
Issued 6 December 2001
Resolved
Vessel to display on fire control plan new location for international shoreconection.
Documentation
Issued 6 December 2001
Resolved
Vessel to provide garbage log book.
Electrical
Issued 6 December 2001
Resolved
Vessel to replace all missing light covers throught ship.(Engine room, Cabins, Forecastls, etc.)
Electrical
Issued 6 December 2001
Resolved
Vessel to reinstall/remove electrical wiring with proper outlets-recepticaloutlets, connection lugs, and or remove from spaces if not in use throughout ship.
Fire Fighting
Issued 6 December 2001
Resolved
Vessel to replace/install bulkhead, overhead sheeting throught ship.
Accommodation/Occupational Safety
Issued 6 December 2001
Resolved
Vessel to replace porthole windows.
Accommodation/Occupational Safety
Issued 6 December 2001
Resolved
When in-port vessel to lock bathroom-head-waterclosets, at deck 3 portside aft. (Piping leads directly out to sea)
Lifesaving
Issued 6 December 2001
Resolved
Vessle to reinstall/patch holes from missing eye bolts and capsized safety bars on port side lifeboat.
Lifesaving
Issued 6 December 2001
Resolved
Vessel to provide proof of registration of EPIRB.
Navigation
Issued 6 December 2001
Resolved
Vessel to provide maneuvering fact sheet with warning statement.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.