← All vessels
HERCULES 250
HERCULES 250 is a 1974 mobile offshore drilling unit. The Coast Guard has recorded 75 inspections since 1983, most recently in April 2009, along with 211 deficiencies and 1 operational control.
Records from 1983 to 2009. Most recent: inspection, 20 April 2009.
- Built
- 1974
- Last inspected
- 20 April 2009
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 211 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8755510 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
HO9039
387865
Flag
LIBERIA
—
Maury page id
psix-387865
Inspections, by type
…with no type recorded21
Years with a record
26 calendar years (1983–2009)
The 75 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.
Documentation record
Tonnage as PSIX records it5288 - Regulatory (Subpart C or D), Gross Ton
1586 - Regulatory (Subpart C or D), Net Ton
1586 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 75
20 April 2009
COC-MODU Annual
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3543262
7 March 2009
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3429205
26 March 2008
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3171873
18 January 2008
COC-MODU Renew
Type not classified · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3131405
5 July 2007
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2984185
11 May 2007
Administrative Inspection
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2953534
25 April 2007
COC-MODU Annual
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2915317
25 April 2007
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2915535
20 January 2006
COC-MODU Renew
Type not classified · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2569586
25 July 2005
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2466948
3 April 2005
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2336571
24 February 2005
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2347707
28 January 2005
COC-MODU Annual
Type not classified · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2282424
16 September 2004
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2197283
20 January 2004
Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2000367
28 March 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1764369
20 March 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1760145
4 February 2003
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1739686
14 February 2002
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1633460
23 June 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1068637
26 April 2001
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1063080
20 March 2001
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1064581
17 February 2001
Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1470297
10 June 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 818760
8 March 2000
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1046111
2 March 2000
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1046880
17 February 2000
Letter of Compliance (Initial/Renewal)
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1468553
14 February 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 816168
15 April 1999
Deficiency Check · Letter of Compliance (Initial/Renewal)
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1388744
30 March 1998
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1364647
10 March 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 785503
23 January 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 101302
24 October 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 778353
24 October 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 778741
22 August 1997
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 784965
21 July 1997
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1115370
20 June 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2268
31 March 1997
Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1371814
27 March 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1091584
26 August 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 150258
12 July 1996
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1089797
4 June 1996
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1086338
10 April 1996
Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1371390
21 April 1995
Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1355206
4 October 1994
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 870559
15 September 1994
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 869271
15 September 1994
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 870043
23 May 1994
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1169533
21 April 1994
Letter of Compliance (Initial/Renewal)
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1405552
11 December 1993
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 102461
20 October 1993
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 43126
17 October 1993
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 113204
8 October 1993
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 25891
26 April 1993
Certificate of Compliance · Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 825794
19 March 1993
Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1426766
31 October 1991
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1312785
9 April 1991
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 927812
6 December 1990
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 912154
24 October 1990
Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1234276
24 October 1989
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 897764
23 January 1989
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1210218
6 December 1988
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 899165
25 October 1988
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1205260
25 January 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1326036
3 December 1987
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1008113
24 October 1987
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1331556
1 March 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1017666
25 October 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1004131
4 November 1985
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1299751
4 November 1985
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1302213
24 October 1985
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1300344
30 October 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1284405
18 April 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1281361
20 July 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 967394
14 April 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1274907
Deficiency record · 211
Lifesaving › Lifeboat › Safety Belt
Issued 20 April 2009
Resolved
Lifeboat #2 (Port) was fouind in poor shape.
Required lifeboat to be repaired/replaced to original manufactures specifications. Downgraded lifeboat max POB from 50 nto 41.
Construction/Loadline › Hull › Side Shell
Issued 11 May 2007
Resolved
Vessel's buoyant tank in the mat has a fracture causing vessel to list. In accordance with ABS Load Line temporary certificate and vessel's tow plan, the vessel is to transit to Gulf Copper Shipyard, TX to affect permanent repairs to fracture on buoyant tank prior to departure.
Fire Fighting › Fixed Fire Detection System › Manually Operated Call Points
Issued 20 January 2006
Resolved
Repair fire alarm panel and fire alarm contact makers associated with same system to the satisafaction of flag state/class society. Submit reports to the Coast Guard.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 20 January 2006
Resolved
Revise fire control plan to accurately reflect items on rig to include IMO symbology and color structural fire protection to the satisfaction of flag state/ class society. Submit report to Coast Guard.
Electrical › Electric Generation Source (emergency)
Issued 20 January 2004
Resolved
Load test emergency batteries per 46 CFR 109.211
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 20 January 2004
Resolved
Submit EEP for USCG approval.
Deck/Cargo › Cargo Transfer (solid)
Issued 20 January 2004
Resolved
Provide documentation that cranes have been examined and accepted by the Flag State.
Documentation › Safety/Response Plans/Programs
Issued 20 January 2004
Resolved
Provide a Flag State approved SOPEP. LEGACY COMPONENT DESC: SOPEP
Lifesaving › Lifeboat
Issued 20 January 2004
Resolved
Repair lifeboat #1 exhaust oil leak. LEGACY COMPONENT DESC: Propulsion Engine
Fire Fighting › Fixed Deck Foam System
Issued 20 January 2004
Resolved
Have Flag State address the lack of a helideck foam system per 79 MODU Code 9.11.2.2.
Electrical › Lighting (emergency)
Issued 20 January 2004
Resolved
Repair the following battery operated E-lights. Outside of lifeboat #1, and in Rec/TV room. LEGACY COMPONENT DESC: Battery Operated Lantern
Fire Fighting › International Shore Connection › Bolts
Issued 20 January 2004
Resolved
Provide bolts for international shore connection.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 20 January 2004
Resolved
Ensure stairway doors are self closing. 79 MODU Code 9.2.3
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 January 2004
Resolved
Repair electrical wires leading into dryer exhaust booster fans in laundry room.
Electrical › Electrical Distribution System (service)
Issued 20 January 2004
Resolved
Re-mount J-box behind washer in laundry room. LEGACY COMPONENT DESC: Junction Box
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 20 January 2004
Resolved
Clean E-light lens near ladder in weight room.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 20 January 2004
Resolved
Make instructions clear at CO2 system manual release stations for the EMD/pump room, generators 1-3.
Construction/Loadline › Structures
Issued 20 January 2004
Resolved
Secure port aft store room deck cover leading into the void. LEGACY COMPONENT DESC: Manhole
Engineering › Diesel Engine (auxiliary)
Issued 20 January 2004
Resolved
Re-wrap DC generator exhaust insulation. LEGACY COMPONENT DESC: Piping (exhaust)
Electrical › Electrical Distribution System (service)
Issued 20 January 2004
Resolved
Replace cover on J-box near exhaust. LEGACY COMPONENT DESC: Junction Box
Engineering › Lubricating Oil Service System
Issued 20 January 2004
Resolved
Remove/clean excessive oil in pan under DC generators and bilge
Electrical › Electric Supply System (service)
Issued 20 January 2004
Resolved
On #1 mud pump, reseal electrical wire to chain oiler motor. LEGACY COMPONENT DESC: Cable
Electrical › Lighting (emergency)
Issued 20 January 2004
Resolved
Clean or replace lens cover on E-light in pump room. LEGACY COMPONENT DESC: Battery Operated Lantern
Fire Fighting › Fixed Fire Detection System
Issued 20 January 2004
Resolved
Ensure the automatic fire detection system is tested to the satisfaction of the Flag State.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure
Issued 20 January 2004
Resolved
Replace portable fire Ext. #32.
Fire Fighting › Firemans Outfit
Issued 20 January 2004
Resolved
Provide spare SCBA bottle for fire locker #1. LEGACY COMPONENT DESC: Self-Contained Breathing Apparatus
Documentation › Manuals/Policy Documentation
Issued 20 January 2004
Resolved
Provide flag state approval for Ops Manual.
Accommodation/Occupational Safety › Ventilation
Issued 20 January 2004
Resolved
Adjust mud pit doors to ensure self closing.
Electrical › Electrical Distribution System (service)
Issued 20 January 2004
Resolved
Provide grounding straps for motors in pit room. LEGACY COMPONENT DESC: Grounding Conductor
Electrical › Lighting (emergency)
Issued 20 January 2004
Resolved
Remove plastic wrap and clean E-light in stbd p-tank room. LEGACY COMPONENT DESC: Battery Operated Lantern
Engineering › Fuel Oil Storage/Transfer System
Issued 20 January 2004
Resolved
Repair fuel line leak, and leaking weld on day tank. LEGACY COMPONENT DESC: Tank
Electrical › Electrical Distribution System (service)
Issued 20 January 2004
Resolved
Replace grounding straps on fuel pump 1 & 2 and transfer pump to day tank. LEGACY COMPONENT DESC: Grounding Conductor
Engineering › Compressed Air System (control)
Issued 20 January 2004
Resolved
Re-seal air line to BOP remote station
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 20 January 2004
Resolved
Free-up bolts for change room vent cover.
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 6 February 2003
Resolved
Provide battery powered embarkation lights at life rafts in accordance with para. 7.I. of enclosure 1 to NVIC 3-88 Ch. 1.
Navigation › Collision/Grounding Avoidance
Issued 6 February 2003
Resolved
Prove proper operation of obstruction lights including synchronization.
Electrical
Issued 6 February 2003
Resolved
Prior to drilling prove mud pit room ventalation and all purged enclosures on drill floor.
Lifesaving
Issued 4 February 2003
Resolved
Prior to drilling conduct fire and boat drills in the presence of a CG Marine Inspector.
Electrical
Issued 17 February 2001
Resolved
INSTALL TWO BATTERY OPERATED E-LIGHTS IN THE PORT AND STARBOARD P TANK ROOMS.
Engineering
Issued 17 February 2001
Resolved
INSTALL FLEXIBLE METALLIC COUPLING ON FUEL LINE IN THE PORT ENGINE ROOM.
Fire Fighting
Issued 17 February 2001
Resolved
PROVIDE PROPER ACCESS TO PULL STATION AT CO2 BOTTLES.
Electrical
Issued 17 February 2001
Resolved
REMOVE DEAD END WIRE IN OVERHEAD IN PORTSIDE ENGINE ROOM.
Fire Fighting
Issued 17 February 2001
Resolved
PROVE PROPER OPERATION OF FIRE ALARM SYSTEM. FIRE ALARM PULL STATION SOUNDED ABANDON SHIP SIGNAL.
Electrical
Issued 17 February 2000
Resolved
Provide closures (locks) for all power panels that are missing throughout rig.
Electrical
Issued 17 February 2000
Resolved
Replace painted breaker in distribution panel located in the emergency generator room.
Electrical
Issued 17 February 2000
Resolved
Provide necessary light covers for all crew bunks that are missing.
Electrical
Issued 17 February 2000
Resolved
Provide junction box for telephone speaker located in the lower level change room.
Electrical
Issued 17 February 2000
Resolved
Provide wire ties in support of #2 lifeboat winch.
Electrical
Issued 17 February 2000
Resolved
Remove toggle switch from junction box located outside of reefer room_x001C_ (Alarm is for person trapped inside of space and shall have no means to isolate.)
Fire Fighting
Issued 17 February 2000
Resolved
Provide fire hoses of sufficient length to project a jet of water to paint locker area (I.A.W. 1979 IMO Code 9.4.3 para. 1 & 2.)
Electrical
Issued 17 February 2000
Resolved
Install blank cover for exposed wires located in power panel #7.
Electrical
Issued 17 February 2000
Resolved
Properly secure wires in overhead with metal tie wraps within mud room.
Engineering
Issued 17 February 2000
Resolved
Remove dirty oil from D/C generator space bilges and properly dispose of same.
Electrical
Issued 17 February 2000
Resolved
Install blank cover or spare breaker to cover opening in power panel #8.
Accommodation/Occupational Safety
Issued 17 February 2000
Resolved
Properly secure oil drums located in storage room.
Electrical
Issued 15 April 1999
Resolved
REMOVE DEAD-END WIRES INSIDE DRILLERS CONSOLE ON DRILL FLOOR.
Construction/Loadline
Issued 15 April 1999
Resolved
RE-AJUST DOGS ON HATCHES THROUGHOUT RIG TO ENSURE PROPER OPERATION AND CLOSURE.
Electrical
Issued 15 April 1999
Resolved
ENSURE PROPER OPERATION OF EMERGENCY SHUTDOWN FOR BOTH EMD GENERATORS.
Engineering
Issued 15 April 1999
Resolved
POST FUEL OIL TRANSFER PROCEDURES AT TRANSFER STATIONS.
Lifesaving
Issued 15 April 1999
Resolved
PROVE MATERIAL CONDITION OF ALL FOUR PRESSURE VESSELS ON RIG(BY HYDRO TESTING TO 1.5 TIMES THE SAFETIES RELIEF SETTING) TO THE SATISFACTION OF THE AMERICAN BUREAU OF SHIPPING & PROVIDE COPY OF ABS REPORT TO THE [name withheld], TX.
Construction/Loadline
Issued 30 March 1998
Resolved
MAKE STRUCTURAL AND PIPING REPAIRS IN ACCORDANCE WITH WORKLIST ISSUED ON 30MAR98 (REF NARRATIVE SUPPLEMENT). ALL REPAIRS TO BE COMPLETED TO THE SATISFACTION OF THE CLASSIFICATION SOCIETY. FINAL REPAIR SURVEY REPORT TO BE SUBMITTED TO MSO MORGAN CITY.
Fire Fighting
Issued 30 March 1998
Resolved
CROP AND RENEW WASTED AND HOLED PIPING AT FIRE STATION NO. 1 AND NO. 2.
Lifesaving
Issued 30 March 1998
Resolved
CONDUCT LIFEBOAT RELEASE GEAR TEST UNDER A LOAD OF 1.1 TIMES THE TOTAL MASSOF THE LIFEBOAT WHEN LOADED WITH ITS FULL COMPLEMENT OF PERSONS AND EQUIPMENT.
Lifesaving
Issued 30 March 1998
Resolved
IMPLEMENT POLICY TO CONDUCT LINETHROWING APPLIANCE TRAINING EVERY THREE MONTHS AND INSPECT THE EPIRB EVERY MONTH. LOG EACH TRAINING SESSION AND EPIRB INSPECTION.
Electrical
Issued 30 March 1998
Resolved
REPAIR AND CONDUCT SATISFACTORY TEST OF THE REVERSE POWER RELAY SYSTEM ON A/C GENERATOR NO. 1.
Fire Fighting
Issued 30 March 1998
Resolved
PLACE FIRE RESISTANT GLOVES IN EACH FIREMAN'S OUTFIT.
Accommodation/Occupational Safety
Issued 30 March 1998
Resolved
MAKE ACCOMMODATIONS MEET THE SIZE OF SLEEPING SPACES REQUIREMENTS OF 46 CFR108.201 AND THE BERTH AND LOCKER REQUIREMENTS OF 46 CFR 108.203. NOTE: NINE PERSONNEL ARE IMPROPERLY ACCOMMODATED IN A SINGLE SPACE.
Lifesaving
Issued 30 March 1998
Resolved
IMPLEMENT POLICY FOR OFFSHORE INSTALLATION MANAGER TO ENTER A STATEMENT IN THE LOGBOOK STATING ADEQUATE REASONS FOR NOT CONDUCTING REQUIRED OPERATIONS(46 CFR 109.213 (h)(2)). NOTE: THE LIFEBOATS WERE NOT OPERATED IN THE WATER FROM JUNE TO DECEMBER, 1997.
Accommodation/Occupational Safety
Issued 31 March 1997
Resolved
HOOK UP DRYER VENT IN LOWER LAUNDRY ROOM
Fire Fighting
Issued 31 March 1997
Resolved
REPAIR/REPLACE LEAKING VALVE AT FIRE STATION #8
Navigation
Issued 31 March 1997
Resolved
CLEAN RUNNING LIGHT LENSES TO PROVE PROPER OPERATION
Fire Fighting
Issued 31 March 1997
Resolved
MAKE REPAIRS AS NOTED IN DEFICIENCY REPORT OF 15MAR97 TO FIRE DETECTION SYSTEM AND FIRE FIGHTING EQUIPMENT OR PROVE THEY ARE NOT REQUIRED
Lifesaving
Issued 31 March 1997
Resolved
PROVIDE HYDROSTATIC TESTING OF SPARE SCBA CANNISTERS
Fire Fighting
Issued 31 March 1997
Resolved
REPAIR LEAK TO VALVE ON FIRE STATION #5.
Engineering
Issued 31 March 1997
Resolved
REPLACE CRACKED FUEL LINES ON ALL GENERATORS
Engineering
Issued 31 March 1997
Resolved
PROVE OPERATION OF REMOTE SHUTDOWN FOR FUEL OIL SHUTDOWN PUMPS
Electrical
Issued 31 March 1997
Resolved
PLACE BLANK OVER MISSING BREAKER IN PANEL ON EMERGENCY GENERATOR SWITCHBOARD
Fire Fighting
Issued 31 March 1997
Resolved
LABEL ALL ALARM LIGHTS AND BELLS OR HORNS PROPERLY
Fire Fighting
Issued 31 March 1997
Resolved
REPAIR ALL WASTED FIREMAIN AND SALTWATER PIPING TO THE FIREMAIN SYSTEM AND HAVE CLASS INSPECT REPAIRS. SUBMIT REPORT FROM CLASS TO COAST GUARD OF APPROVED REPAIRS.
Accommodation/Occupational Safety
Issued 31 March 1997
Resolved
LOG DISCHARGES OF FOOD WASTE IN GARBAGE DISCHARGE LOG
Construction/Loadline
Issued 31 March 1997
Resolved
PROVIDE GASKET AND REPAIR KNIFE EDGE HATCH COAMING TO STBD SACK ROOM HATCH
Unknown
Issued 31 March 1997
Resolved
AT NEXT RIG MOVE TEST OPERATION OF TOTAL RIG SHUTDOWN
Lifesaving
Issued 31 March 1997
Resolved
PROVIDE LIGHTSTICKS FOR BOTH LIFEBOAT COMPASSES
Lifesaving
Issued 31 March 1997
Resolved
PROVIDE REPLACEMENT PROVISIONS FOR 8 REJECTED (#2 LIFEBOAT), 9 REJECTED(#1 LIFEBOAT
Lifesaving
Issued 31 March 1997
Resolved
REMOVE LINE FROM QUICK RELEASE RING BUOY STATIONS, MOVE TO MAIN DECK RING BUOY STATIONS.
Lifesaving
Issued 10 April 1996
Resolved
LABEL ALL ALARMS AND SIRENS (AUDIBLE AND VISUAL).
Electrical
Issued 10 April 1996
Resolved
RESOLVE ALL EXCESSIVE OIL LEAKS ON BOTH AC GENERATORS.
Fire Fighting
Issued 10 April 1996
Resolved
PROVIDE OPERATING INTRUCTIONS AT CO2 CYLINDERS FOR MACHINERY SPACES.
Construction/Loadline
Issued 10 April 1996
Resolved
REPAIR SPRUNG WATERTIGHT DOOR #20 AND #28 PRIOR TO NEXT RIG MOVE.
Documentation
Issued 10 April 1996
Resolved
PROVIDE A LIST OF ALL EXEMPTIONS GRANTED BY PANAMA FOR THE RIG'S IMO MODU CODE.
Accommodation/Occupational Safety
Issued 10 April 1996
Resolved
REPAIR/REPLACE DAMAGED EMERGENCY ESCAPE LADDER ON STBD BOW.
Construction/Loadline
Issued 10 April 1996
Resolved
REPAIR/REPLACE WASTED BULKHEAD TO PAINT LOCKER.
Fire Fighting
Issued 10 April 1996
Resolved
PROVIDE PANTS FOR FIREMAN'S OUTFITS.
Fire Fighting
Issued 10 April 1996
Resolved
PROVIDE REPORT FROM CLASS SOCIETY ON REPAIRS AND SUBSEQUENT TESTING OF FIXED CO2 SYSTEM FOR MACHINERY SPACES.
Fire Fighting
Issued 10 April 1996
Resolved
REPAIR HOLES IN CO2 BRANCH LINE BY MUDPIT ROOM WATERTIGHT DOOR #6.
Construction/Loadline
Issued 10 April 1996
Resolved
PLUG OPEN BULKHEAD PENETRATIONS (2) BY MUDPIT ROOM WATERTIGHT DOOR #6.
Accommodation/Occupational Safety
Issued 10 April 1996
Resolved
LABEL CONTROLLERS FOR BOTH FIRE PUMPS.
Fire Fighting
Issued 10 April 1996
Resolved
RESOVLE LEAKING NOZZLE AND VALVE STEM AT FIRE STATION #10.
Fire Fighting
Issued 10 April 1996
Resolved
REPAIR/REPLACE PARTS AS NECESSARY TO MAKE FIXED CO2 SYSTEM FOR MACHINERY SPACES OPERATIONAL.
Fire Fighting
Issued 10 April 1996
Resolved
TEST ALL HEAT DETECTORS IN MACHINERY SPACES.
Navigation
Issued 10 April 1996
Resolved
REPAIR FAULTY OBSTRUCTION LIGHT ON PORT LEG.
Electrical
Issued 10 April 1996
Resolved
REPAIR/REPLACE BROKEN LATCH TO ELECTRICAL PANEL "EL1-9" ON MAINDECK OF QUARTERS.
Fire Fighting
Issued 10 April 1996
Resolved
PROVIDE WHEELED CO2 EXTINGUISHER ON HELODECK IN ACCORDANCE WITH IMO MODE CODE.
Accommodation/Occupational Safety
Issued 10 April 1996
Resolved
REPLACE WASTED DECK PLATING AT BASE OF EMERGENCY ESCAPE LADDER ON PORT LEG.
Electrical
Issued 10 April 1996
Resolved
INSTALL AN EMERGENCY LIGHT IN PORTSIDE QUARTERS MAINDECK PASSAGEWAY.
Fire Fighting
Issued 10 April 1996
Resolved
CROP AND RENEW WASTED FIREMAIN PIPING AT FIRE STATION #6.
Fire Fighting
Issued 10 April 1996
Resolved
REPLACE AS NECESSARY ALL EXCESSIVELY SCRATCHED LENS TO SELF-CONTAINED BREATHING APPARTUSES.
Accommodation/Occupational Safety
Issued 10 April 1996
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Lifesaving
Issued 10 April 1996
Resolved
DETERMINE CONDITION AND SERVICEABILITY OF WASTED PORTSIDE LIFEBOAT DAVIT STRUCTURE AND PROVIDE SUBSEQUENT REPORT TO MSO PORT ARTHUR.
Lifesaving
Issued 10 April 1996
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Electrical
Issued 21 April 1995
Resolved
REPAIR RED ROTATING WARNING BEACON FOR GENERAL ALARM SYSTEM IN EMD MOTOR ROOM SPACE.
Electrical
Issued 21 April 1995
Resolved
INSTALL WARNING PLACARDS BY RED WARNING ROTATING BEACONS STATING "WHEN THE GENERAL ALARM SOUNDS GO TO YOUR STATIONS".
Construction/Loadline
Issued 21 April 1995
Resolved
REMOVE EXCESSIVE AMOUNT OF OIL AND WATER IN MOTORROOM BILGES AND UNDER MAINGENERATOR UNITS.
Electrical
Issued 21 April 1995
Resolved
INSTALL A GENERAL ALARM BELL OR A RED WARNING ROTATING BEACON LIGHT FIXTUREBY NUMBER 2 EMD GENERATOR.
Fire Fighting
Issued 21 April 1994
Resolved
Install new CO2 horn for mud room.
Unknown
Issued 21 April 1994
Resolved
Submit cover sheet of approved construction portfolio.
Unknown
Issued 21 April 1994
Resolved
Provide documentation from class society for port crane inspection status.
Unknown
Issued 21 April 1994
Resolved
Repair outboard side of port crane deck walk.
Fire Fighting
Issued 19 March 1993
Resolved
INSTALL MISSING CO2 CYLINDAR FOR FIXED SYSTEM IN ENGINE ROOM.
Lifesaving
Issued 19 March 1993
Resolved
PROVE FLAG STATE ACCEPTANCE OF PROVISIONS, EQUIPMENT, STRUCTURE, AND WINCHES FOR BOTH LIFEBOATS.
Unknown
Issued 19 March 1993
Resolved
CLEAR ALL OUTSTANDING REQUIREMENTS ISSUED TO PREVIOUS OWNER/OPERATOR; REFERENCE CASES MI89033493 AND MI91032739.
Electrical
Issued 19 March 1993
Resolved
PROVE PROPER OPERATION OF LOSS OF PURGE ALARMS FOR ELECTRICAL EQUIPMENT ON DRILLER'S CONSOLE AND DRILL FLOOR.
Lifesaving
Issued 19 March 1993
Resolved
PROVE FLAG STATE ACCEPTANCE OF STBD LIFE BOAT AND DAVIT WEIGHT TEST.
Lifesaving
Issued 19 March 1993
Resolved
PUT ALL PROVISIONS/EQUIPMENT IN LIFEBOATS.
Electrical
Issued 19 March 1993
Resolved
PROVE PROPER OPERATION OF EMERGENCY GENERATOR OVERSPEED TRIP.
Fire Fighting
Issued 31 October 1991
Resolved
PROVIDE PROPER SEAL FOR PAINT LOCKER AROUND DOOR AND HOLES IN SIDE BULKHEAD._x001C_ _x001C_ _x001C_
Deck/Cargo
Issued 31 October 1991
Resolved
PROVIDE CRANE CERTIFICATES INDICATING ANNUAL AND FIVE YEAR LOAD TEST INSPECTION._x001C_ _x001C_ _x001C_
Documentation
Issued 31 October 1991
Resolved
REVISE THE OPERATION MANUAL TO MEET 46 CFR 109.121._x001C_ _x001C_ _x001C_ _x001C_
Fire Fighting
Issued 31 October 1991
Resolved
PROPERLY CALIBRATE BOTH OXYGEN METERS REQUIRED FOR THE FIREMAN'S OUTFITS._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 31 October 1991
Resolved
PROPERLY LABEL ALL REQUIRED INFORMATION ON #1 AND #2 LIFEBOATS WITH 3 INCHLETTERS WITH EXCEPTION OF 1.5 INCH LETTERS FOR BOAT CAPACITY._x001C_ _x001C_ _x001C_
Lifesaving
Issued 31 October 1991
Resolved
REPAIR LIMIT SWITCHES ON #1 LIFEBOAT._x001C_ _x001C_ _x001C_ _x001C_
Deck/Cargo
Issued 31 October 1991
Resolved
MAKE APPROVED REPAIRS TO EXCESSIVE PITTING ON BULK TANKS LOCATED ON THE UPPER DECK. PROVIDE CERTIFICATES OF QUALIFIED WELDERS._x001C_ _x001C_ _x001C_
Engineering
Issued 31 October 1991
Resolved
PROVIDE PROOF OF INTERNAL INSPECTION OR HYDROSTATIC TEST OF ALL PRESSURE VESSELS AND TESTING OF RELIEF VALVES BY ABS._x001C_ _x001C_ _x001C_
Fire Fighting
Issued 31 October 1991
Resolved
PROVIDE GAUGING REPORT OF ALL THE FIRE MAIN PIPING IN THE AREA OF THE PRIMARY FIRE PUMP._x001C_ _x001C_ _x001C_
Documentation
Issued 31 October 1991
Resolved
UPDATE HAZARDOUS LOCATION PLAN TO INDICATE ENTIRE DRILL FLOOR AS CLASS I DIVISION II AREA EXCEPT FOR FIVE (5) FOOT RADIUS AROUND ROTARY TABLE WHICH WILL INDICATE A CLASS I DIVISION I AREA. _x001C_ _x001C_
Unknown
Issued 6 December 1990
Resolved
PLACE ONBOARD FLOAT FREE SURVIVAL CRAFT PER IMO CODE SECTION 10.1.1.2 FOR 100 PERCENT OF PERSONS ALLOWED ONBOARD.
Unknown
Issued 24 October 1990
Resolved
MAKE PERMANENT REPAIRS TO PORT CRANE RAILING WHERE WASTED.
Unknown
Issued 24 October 1990
Resolved
REMOVE LOCK-BACK MECHANISMS FROM SELF-CLOSING WATERTIGHT DOORS IN MUDPIT ROOM.
Unknown
Issued 24 October 1990
Resolved
PLACE ONBOARD FLOAT FREE SURVIVAL CRAFT PER IMO MODU CODE SEC.10.1.1.2 FOR 100 PERCENT OF PERSONS ALLOWED ONBOARD, OR PRESENT FROM HOME ADMINISTRATIONDOCUMENTATION THAT PRESENT ARRANGEMENT IS EQUIVALENT TO OR IS EXEMPT FROM IMO MODU CODE REQUIREMENT.
Unknown
Issued 24 October 1990
Resolved
REPLACE ALL PLASTIC FIRE HOSES WITH RUBBER LINED AND UL/FM APPROVED.
Electrical
Issued 24 October 1989
Resolved
PROPERLY END THE STANDBY GENERATOR HEATER CABLES.
Electrical
Issued 24 October 1989
Resolved
REPAIR THE KICK PIPES ON THE PORT SIDE OF THE DRILL HOUSE.
Electrical
Issued 24 October 1989
Resolved
REPAIR THE KICK PIPE FOR MUD SUPPLY FAN.
Accommodation/Occupational Safety
Issued 24 October 1989
Resolved
SUPPLY APPROVED SAFETY BELTS.
Deck/Cargo
Issued 24 October 1989
Resolved
MAKE CRANES AVALABLE FOR ANNUAL INSPECTION.
Electrical
Issued 24 October 1989
Resolved
PROVIDE LOSS OF PURGE ALARMS ON THE 480V EXPLOSION PROOF STYLE & JUCTION BOXES ON THE DRILL FLOOR.
Documentation
Issued 24 October 1989
Resolved
PROVIDE AN APPROVED CONSTRUCTION PORTFOLIE.
Electrical
Issued 24 October 1989
Resolved
INSTALL AND POUR EYS ON THE MOTOR
Construction/Loadline
Issued 24 October 1989
Resolved
REPAIR THE SOUNDING TUBE ON THE STBD SIDE OF THE MAIN DECK.
Electrical
Issued 24 October 1989
Resolved
POUR THE EYS FITTING ON THE #2 SHALE SHAKER MOTOR
Fire Fighting
Issued 24 October 1989
Resolved
HYDROSTATIC TEST THE CO2 BOTTLES FOR THE PAINT LOCKER AND GREASE LOCKER FLOOR SYSTEM.
Electrical
Issued 24 October 1989
Resolved
INSTALL A LOSS OF PURGE ALARM ON THE DRILL FLOOR SOUND POWERED PHONE.
Electrical
Issued 24 October 1989
Resolved
REPAIR OR RENEW THE GAS DETECTOR PANEL LOSS OF PURGE ALARM ON THE DRILL FLOOR.
Electrical
Issued 24 October 1989
Resolved
INSTALL AND POUR A TRIPLE PUMP STARTER EYS (KOOMEY)
Electrical
Issued 24 October 1989
Resolved
INSTALL A LOSS OF PURGE ALARM ON THE AMP METER BOX ON THE DRILLERS CONSOLE.
Electrical
Issued 24 October 1989
Resolved
PROVIDE A LOSS OF PURGE ALARM ON THE SOUND POWERED PHONE IN THE SHALE SHAKER AREA.
Unknown
Issued 6 December 1988
Resolved
REPAIR LEAK IN SALT WATER LINE IN STARBOARD SACK STORAGE ROOM.
Unknown
Issued 6 December 1988
Resolved
MOVE ALL NON EXPLOSIVE PROOF EQUIPMENT BEYOND 10 FT FROM THE MUD PIT DOORS;MOVE AGITATOR CONTROLLER ON PORT SIDE AND OUTLET ON THE STARBOARD SIDE.
Unknown
Issued 6 December 1988
Resolved
CORRECT THE PRESSURE PROBLEM WITH THE #3 FIRE HOSE STATION PIPING OR GATE VALVE.
Construction/Loadline
Issued 25 October 1988
Resolved
NON-SKID THE HELO DECK.
Deck/Cargo
Issued 25 October 1988
Resolved
CHANGE THE FUEL LINES ON THE TWO CRANES TO AN APPROVED HOSE FOR FUEL OIL SERVICE WHICH IS FIRE PROOF.
Unknown
Issued 25 October 1988
Resolved
CLEAN THE GREASE TRAP AND DUCT WORK FOR THE GALLEY HOOD.
Unknown
Issued 25 October 1988
Resolved
OPEN FOR INTERNAL INSPECTION THE FOLLOWING AIR RECEIVERS: NO.3 CEMENT, NO.1 & 4 DRY MUD, AND THE DRILL FLOOR AIR RECEIVER.
Electrical
Issued 25 October 1988
Resolved
MAKE ALL WIRING IN THE MUD PIT SUITABLE FOR CLASS I DIV I (ARMORED). HAZARDOUS AREA PLAN STANDARD IS API 500.
Unknown
Issued 25 October 1988
Resolved
REPLACE MISSING DOGS ON CEMENT TANKS.
Electrical
Issued 25 October 1988
Resolved
DEMONSTRATE OPERATION OF LOCAL AND REMOTE SHUT OFFS FOR MOST FORWARD FUEL PUMP.
Electrical
Issued 25 October 1988
Resolved
PROVIDE BLANKS FOR 120-208V DISTRIBUTION PANEL.
Fire Fighting
Issued 25 October 1988
Resolved
CORRECT THE PRESSURE PROBLEM WITH THE #3 FIRE HOSE STATION PIPING OR GATE VALVE.
Documentation
Issued 25 October 1988
Resolved
PRESENT OIL RECORD BOOK, OIL TRANSFER PROCEDURES DOCUMENTATION OF HYDROSTATIC TEST OF OIL TRANSFER HOSES, AND DESIGNATED PERSON IN CHARGE AS REQUIRED BY 33 CFR 151 & 33 CFR 155.
Electrical
Issued 25 October 1988
Resolved
REPAIR REVERSE POWER RELAY FOR #2 GENERATOR.
Electrical
Issued 25 October 1988
Resolved
REMOVE ALL DISCONNECTED WIRING OVER THE DRILLERS CONSOLE.
Electrical
Issued 25 October 1988
Resolved
DEMONSTRATE THE PROPER OPERATION OF THE #2 GENERATOR.
Unknown
Issued 25 October 1988
Resolved
ULTRASONICALLY GAUGE THE PITTED AREAS ON TOP OF CEMENT TANKS. PROVIDE U1A FORMS ON CONSTRUCTION DATA SCANTLING.
Electrical
Issued 25 October 1988
Resolved
MAKE ALL BULKHEAD PENETRATIONS IN THE MUD PIT SUITABLE FOR CLASS I DIV I.
Unknown
Issued 25 October 1988
Resolved
PROVIDE AIR PURGE FOR SHELL SHAKER AREA PHONE.
Unknown
Issued 25 October 1988
Resolved
REPAIR LEAK IN SALT WATER LINE IN STARBOARD SACK STORAGE ROOM
Electrical
Issued 25 October 1988
Resolved
MOVE ALL NON EXPLOSIVE PROOF EQUIPMENT BEYOND 10 FT FROM THE MUD PIT DOORS;MOVE AGITATOR CONTROLLER ON PORT SIDE AND OUTLET ON THE STARBOARD SIDE.
Construction/Loadline
Issued 25 October 1988
Resolved
RENEW SUPPORTS FOR FENDER BASKETS.
Construction/Loadline
Issued 25 October 1988
Resolved
REPLACE HINGE PINS AS NECESSARY ON THE WATER TIGHT HATCHES ON THE MAIN DECK.
Electrical
Issued 25 October 1988
Resolved
PROVIDE SUITABLE POWER SUPPLY CABLE FOR THE LOGGERS SHACK.
Electrical
Issued 25 October 1988
Resolved
SECURE ALL WIRES ABOVE THE DRILLERS CONSOLE WITH METAL BANDING. 5/8 INCH BANDS ARE REQUIRED FOR PVC TYPE CABLES.
Documentation
Issued 25 October 1988
Resolved
RESUBMIT THE OPERATIONS MANUAL TO THE FLAG STATE REPRESENTATIVE FOR REAPPROVAL.
Fire Fighting
Issued 24 October 1987
Resolved
PROVIDE EVIDENCE THAT THE DISCHARGE HOSE ON THE DELO DECK B-V FIRE EXTINGUISHER WAS SATISFATORILY TESTED PER 46 CFR 147 OR REPLACE THE SAME APPROPIATELY.
Fire Fighting
Issued 24 October 1987
Resolved
DEMONSTRATE A PETOT TUBE PRESSURE READING OF NOT LESS THAN FORTY PSI WHILE TWO HYDRANTS ARE DISHCARGNG SIMULTANEOUSLY.
Electrical
Issued 24 October 1987
Resolved
PROVE PROPER OPERATION OF THE STAND BY GENERATOR AND CONDUCT TWO HOUR REQUIRED TESTING UNDER LOAD.
Fire Fighting
Issued 24 October 1987
Resolved
PROVIDE EVIDENCE DEMONSTRATING THAT THE NITROGEN BOTTLE FOR THE HELO DECK B-V FIRE EXTINGUISHER HAS BEEN HYDROSTATICALLY TESTED.
Electrical
Issued 24 October 1987
Resolved
MAKE THE LOSS OF PURGE ALARM ON THE DRILLERS CONSOLE OPERABLE.
Lifesaving
Issued 24 October 1987
Resolved
PROVIDE EVIDENCE INDICATING THAT THE CARBON DIOXIDE INFLATION CYLINDERS FOR THE RIGHTING BAG ON BOTH (PORT AND STARBOARD) CAPSULES HAVE BEEN SATISFACTORILY HYDROSTATICALLY TESTD.
Fire Fighting
Issued 24 October 1987
Resolved
REPLACE EX-607 (2Q80) HOSE ON B-V FIRE EXTINGUISHER FOR HELO DECK WITH SWITCHABLE HOSE. (THIS APPLIES TO NEW UNIT, NOT THE B-V MENTIONED IN ITEM 3)
Lifesaving
Issued 24 October 1985
Resolved
PROVIDE 12 PARACHUTE FLARES TO LIFEBOAT #1. 46 CFR 108.503.
Lifesaving
Issued 24 October 1985
Resolved
PROVIDE 150 FOUR OZ WATER PACKETS TO LIFEBOAT #1 AND #2. 46 CFR 108.503.
Navigation
Issued 24 October 1985
Resolved
MAKE OPERATIONAL THE NORTHEAST CORNER OBSTRUCTION LIGHT. COLREGS 33 CFR 81.
Lifesaving
Issued 24 October 1985
Resolved
PROVIDE BEWARE OF THE TAIL ROTOR AT EACH ACCESS TO THE HELO DECK. 46 CFR 108.653(C).
Lifesaving
Issued 24 October 1985
Resolved
MAKE PERMANENT REPAIRS TO FORWARD FLIGHT DECK NETTING. 46 CFR 108.235(C).
Deck/Cargo
Issued 24 October 1985
Resolved
PROVIDE AN OPERATIONAL BOOM ANGLE INDICATOR. 46 CFR 108.601.
Deck/Cargo
Issued 24 October 1985
Resolved
MAKE OPERATIONAL FUEL OIL TRANSFER PUMP REMOTE SHUTDOWN. 46 CFR 58.01.
Lifesaving
Issued 24 October 1985
Resolved
RENEW LIFEBOAT FALLS ON #1 AND #2 LIFEBOAT. 46 CFR 108.507
Construction/Loadline
Issued 24 October 1985
Resolved
RENEW THE SALT WATER COOLING SUPPLY LINES ON BOTH EMD DIESELS. 46 CFR 58.10.
Electrical
Issued 24 October 1985
Resolved
MAKE OPERATIONAL THE VENTILATION REMOTE SHUTDOWN. 46 CFR 111.103.
Lifesaving
Issued 24 October 1985
Resolved
PROVIDE ONE LIFE PRESERVER TO LIFEBOAT #2. 46 CFR 108.503.
Fire Fighting
Issued 30 October 1984
Resolved
MAKE PERMANENT REPAIRS TO FIXED CO2 EXTINGUISHER SYSTEM SERVING MACHINERY SPACES.
Unknown
Issued 30 October 1984
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE MODU TELEDYNE RIG 17, O.N. NEW002THE BELOW LISTED ITEMS ARE TO BE COMPLIED WITH BY 30 NOVEMBER 1984.
Lifesaving
Issued 30 October 1984
Resolved
PROVIDE TWELVE (12) HAND HELD PARACHUTE FLARES AND WATERTIGHT STORAGE CON- TAINMENT. 46 CFR 108.521.
Lifesaving
Issued 30 October 1984
Resolved
PROVIDE THE FOLLOWING EQUIPMENT FOR THE NO. 1 LIFEBOAT: SIGNAL MIRROR, 450 CANS OF WATER, BOARDING LADDER, 46 CFR 94.20-10.
Electrical
Issued 30 October 1984
Resolved
REPAIR OR REPLACE GENERAL ALARM BELLS AT PORT STERN TACKING HOUSE, AFTER QUATERS SUPERSTRUCTURE AND MUD PITS.
Lifesaving
Issued 30 October 1984
Resolved
PROVIDE THE FOLLOWING EQUIPMENT FOR THE NO. 2 LIFEBOAT: 450 CANS OF WATER, BOARDING LADDER.
Unknown
Issued 14 April 1983
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL TELEDYNE RIG 17, VIN= NEW002
Unknown
Issued 14 April 1983
Resolved
SUBMIT PROPOSAL FOR PERMANENT REPAIR OF GAUGING IN BOW LEG (AT 166 LEVEL) TO [name withheld].
Unknown
Issued 14 April 1983
Resolved
MAKE PORT MUD PIT DUMP VALVE AVAILABLE FOR INSPECTION.
Unknown
Issued 14 April 1983
Resolved
SUBMIT COPY OF GAUGING REPORT FOR RIG LEGS (AT 35 FT. AND 45 FT LEVEL) AND NO. 3P TANK (BULKHEAD COMMON TO ACTIVE MUD PIT) TO [name withheld].
Unknown
Issued 14 April 1983
Resolved
CONDUCT UNDERWATER INSPECTION OF MAT SIDES, SKIRT AND BOTTOM.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.