MAURY USCG vessel records Sign in
← All vessels

HERCULES 250

HERCULES 250 is a 1974 mobile offshore drilling unit. The Coast Guard has recorded 75 inspections since 1983, most recently in April 2009, along with 211 deficiencies and 1 operational control.

Records from 1983 to 2009. Most recent: inspection, 20 April 2009.

Built
1974
Last inspected
20 April 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8755510 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
HO9039
387865
Flag
LIBERIA
—
Maury page id
psix-387865

Inspections, by type

…with no type recorded21
Years with a record 26 calendar years (1983–2009)
The 75 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it5288 - Regulatory (Subpart C or D), Gross Ton
1586 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 75

20 April 2009 COC-MODU Annual
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3543262
7 March 2009 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3429205
26 March 2008 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3171873
18 January 2008 COC-MODU Renew
Type not classified · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3131405
5 July 2007 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2984185
11 May 2007 Administrative Inspection
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2953534
25 April 2007 COC-MODU Annual
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2915317
25 April 2007 Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2915535
20 January 2006 COC-MODU Renew
Type not classified · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2569586
25 July 2005 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2466948
3 April 2005 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2336571
24 February 2005 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2347707
28 January 2005 COC-MODU Annual
Type not classified · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2282424
16 September 2004 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2197283
20 January 2004 Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2000367
28 March 2003 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1764369
20 March 2003 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1760145
4 February 2003 Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1739686
14 February 2002 Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1633460
23 June 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1068637
26 April 2001 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1063080
20 March 2001 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1064581
17 February 2001 Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1470297
10 June 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 818760
8 March 2000 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1046111
2 March 2000 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1046880
17 February 2000 Letter of Compliance (Initial/Renewal)
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1468553
14 February 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 816168
15 April 1999 Deficiency Check · Letter of Compliance (Initial/Renewal)
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1388744
30 March 1998 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1364647
10 March 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 785503
23 January 1998 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 101302
24 October 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 778353
24 October 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 778741
22 August 1997 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 784965
21 July 1997 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1115370
20 June 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2268
31 March 1997 Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1371814
27 March 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1091584
26 August 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 150258
12 July 1996 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1089797
4 June 1996 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1086338
10 April 1996 Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1371390
21 April 1995 Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1355206
4 October 1994 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 870559
15 September 1994 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 869271
15 September 1994 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 870043
23 May 1994 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1169533
21 April 1994 Letter of Compliance (Initial/Renewal)
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1405552
11 December 1993 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 102461
20 October 1993 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 43126
17 October 1993 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 113204
8 October 1993 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 25891
26 April 1993 Certificate of Compliance · Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 825794
19 March 1993 Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1426766
31 October 1991 Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1312785
9 April 1991 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 927812
6 December 1990 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 912154
24 October 1990 Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1234276
24 October 1989 Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 897764
23 January 1989 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1210218
6 December 1988 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 899165
25 October 1988 Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1205260
25 January 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1326036
3 December 1987 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1008113
24 October 1987 Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1331556
1 March 1987 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1017666
25 October 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1004131
4 November 1985 Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1299751
4 November 1985 Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1302213
24 October 1985 Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1300344
30 October 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1284405
18 April 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1281361
20 July 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 967394
14 April 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1274907

Deficiency record · 211

Lifesaving › Lifeboat › Safety Belt
Issued 20 April 2009 Resolved
Lifeboat #2 (Port) was fouind in poor shape. Required lifeboat to be repaired/replaced to original manufactures specifications. Downgraded lifeboat max POB from 50 nto 41.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 July 2009
Resolution: Received written documentation from OIM that the lifebaot was replaced with a refurbished lifeboat.
Construction/Loadline › Hull › Side Shell
Issued 11 May 2007 Resolved
Vessel's buoyant tank in the mat has a fracture causing vessel to list. In accordance with ABS Load Line temporary certificate and vessel's tow plan, the vessel is to transit to Gulf Copper Shipyard, TX to affect permanent repairs to fracture on buoyant tank prior to departure.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 June 2007
Resolution: Received attestation from Certificate Issuing Authority that satisfactory repairs have been made and that the Hull remains in class.
Fire Fighting › Fixed Fire Detection System › Manually Operated Call Points
Issued 20 January 2006 Resolved
Repair fire alarm panel and fire alarm contact makers associated with same system to the satisafaction of flag state/class society. Submit reports to the Coast Guard.
Action required: 705 - Other - as specified
Due 27 January 2006
Resolved 25 April 2007
Resolution: Received report from ABS via TODCO stating new fire alarm panel installed and tested satisfactorily.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 20 January 2006 Resolved
Revise fire control plan to accurately reflect items on rig to include IMO symbology and color structural fire protection to the satisfaction of flag state/ class society. Submit report to Coast Guard.
Action required: 705 - Other - as specified
Due 20 February 2006
Resolved 25 April 2007
Resolution: Received report from ABS via TODCO approving fire control plan.
Electrical › Electric Generation Source (emergency)
Issued 20 January 2004 Resolved
Load test emergency batteries per 46 CFR 109.211
Due 20 January 2004
Resolved 9 February 2004
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 20 January 2004 Resolved
Submit EEP for USCG approval.
Due 20 January 2004
Resolved 23 January 2004
Deck/Cargo › Cargo Transfer (solid)
Issued 20 January 2004 Resolved
Provide documentation that cranes have been examined and accepted by the Flag State.
Due 20 January 2004
Resolved 1 March 2004
Documentation › Safety/Response Plans/Programs
Issued 20 January 2004 Resolved
Provide a Flag State approved SOPEP. LEGACY COMPONENT DESC: SOPEP
Due 20 January 2004
Resolved 4 February 2004
Lifesaving › Lifeboat
Issued 20 January 2004 Resolved
Repair lifeboat #1 exhaust oil leak. LEGACY COMPONENT DESC: Propulsion Engine
Due 20 January 2004
Resolved 9 February 2004
Fire Fighting › Fixed Deck Foam System
Issued 20 January 2004 Resolved
Have Flag State address the lack of a helideck foam system per 79 MODU Code 9.11.2.2.
Due 20 January 2004
Resolved 9 February 2004
Resolution: LI responded that the foam system is not required without fueling...........
Electrical › Lighting (emergency)
Issued 20 January 2004 Resolved
Repair the following battery operated E-lights. Outside of lifeboat #1, and in Rec/TV room. LEGACY COMPONENT DESC: Battery Operated Lantern
Due 20 January 2004
Resolved 9 February 2004
Fire Fighting › International Shore Connection › Bolts
Issued 20 January 2004 Resolved
Provide bolts for international shore connection.
Due 20 January 2004
Resolved 21 January 2004
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 20 January 2004 Resolved
Ensure stairway doors are self closing. 79 MODU Code 9.2.3
Due 20 January 2004
Resolved 21 January 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 January 2004 Resolved
Repair electrical wires leading into dryer exhaust booster fans in laundry room.
Due 20 January 2004
Resolved 21 January 2004
Electrical › Electrical Distribution System (service)
Issued 20 January 2004 Resolved
Re-mount J-box behind washer in laundry room. LEGACY COMPONENT DESC: Junction Box
Due 20 January 2004
Resolved 9 February 2004
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 20 January 2004 Resolved
Clean E-light lens near ladder in weight room.
Due 20 January 2004
Resolved 21 January 2004
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 20 January 2004 Resolved
Make instructions clear at CO2 system manual release stations for the EMD/pump room, generators 1-3.
Due 20 January 2004
Resolved 9 February 2004
Construction/Loadline › Structures
Issued 20 January 2004 Resolved
Secure port aft store room deck cover leading into the void. LEGACY COMPONENT DESC: Manhole
Due 20 January 2004
Resolved 21 January 2004
Engineering › Diesel Engine (auxiliary)
Issued 20 January 2004 Resolved
Re-wrap DC generator exhaust insulation. LEGACY COMPONENT DESC: Piping (exhaust)
Due 20 January 2004
Resolved 9 February 2004
Electrical › Electrical Distribution System (service)
Issued 20 January 2004 Resolved
Replace cover on J-box near exhaust. LEGACY COMPONENT DESC: Junction Box
Due 20 January 2004
Resolved 21 January 2004
Engineering › Lubricating Oil Service System
Issued 20 January 2004 Resolved
Remove/clean excessive oil in pan under DC generators and bilge
Due 20 January 2004
Resolved 9 February 2004
Electrical › Electric Supply System (service)
Issued 20 January 2004 Resolved
On #1 mud pump, reseal electrical wire to chain oiler motor. LEGACY COMPONENT DESC: Cable
Due 20 January 2004
Resolved 21 January 2004
Electrical › Lighting (emergency)
Issued 20 January 2004 Resolved
Clean or replace lens cover on E-light in pump room. LEGACY COMPONENT DESC: Battery Operated Lantern
Due 20 January 2004
Resolved 9 February 2004
Fire Fighting › Fixed Fire Detection System
Issued 20 January 2004 Resolved
Ensure the automatic fire detection system is tested to the satisfaction of the Flag State.
Due 20 January 2004
Resolved 9 February 2004
Resolution: LI response
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure
Issued 20 January 2004 Resolved
Replace portable fire Ext. #32.
Due 20 January 2004
Resolved 21 January 2004
Fire Fighting › Firemans Outfit
Issued 20 January 2004 Resolved
Provide spare SCBA bottle for fire locker #1. LEGACY COMPONENT DESC: Self-Contained Breathing Apparatus
Due 20 January 2004
Resolved 9 February 2004
Documentation › Manuals/Policy Documentation
Issued 20 January 2004 Resolved
Provide flag state approval for Ops Manual.
Due 20 January 2004
Resolved 9 February 2004
Resolution: LI accepted ABS''s review.
Accommodation/Occupational Safety › Ventilation
Issued 20 January 2004 Resolved
Adjust mud pit doors to ensure self closing.
Due 20 January 2004
Resolved 9 February 2004
Electrical › Electrical Distribution System (service)
Issued 20 January 2004 Resolved
Provide grounding straps for motors in pit room. LEGACY COMPONENT DESC: Grounding Conductor
Due 20 January 2004
Resolved 9 February 2004
Electrical › Lighting (emergency)
Issued 20 January 2004 Resolved
Remove plastic wrap and clean E-light in stbd p-tank room. LEGACY COMPONENT DESC: Battery Operated Lantern
Due 20 January 2004
Resolved 21 January 2004
Engineering › Fuel Oil Storage/Transfer System
Issued 20 January 2004 Resolved
Repair fuel line leak, and leaking weld on day tank. LEGACY COMPONENT DESC: Tank
Due 20 January 2004
Resolved 9 February 2004
Electrical › Electrical Distribution System (service)
Issued 20 January 2004 Resolved
Replace grounding straps on fuel pump 1 & 2 and transfer pump to day tank. LEGACY COMPONENT DESC: Grounding Conductor
Due 20 January 2004
Resolved 9 February 2004
Engineering › Compressed Air System (control)
Issued 20 January 2004 Resolved
Re-seal air line to BOP remote station
Due 20 January 2004
Resolved 9 February 2004
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 20 January 2004 Resolved
Free-up bolts for change room vent cover.
Due 20 January 2004
Resolved 21 January 2004
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 6 February 2003 Resolved
Provide battery powered embarkation lights at life rafts in accordance with para. 7.I. of enclosure 1 to NVIC 3-88 Ch. 1.
Due 6 March 2003
Resolved 25 January 2005
Resolution: Lights have been installed.
Navigation › Collision/Grounding Avoidance
Issued 6 February 2003 Resolved
Prove proper operation of obstruction lights including synchronization.
Due 26 February 2003
Resolved 7 March 2003
Electrical
Issued 6 February 2003 Resolved
Prior to drilling prove mud pit room ventalation and all purged enclosures on drill floor.
Due 1 July 2003
Resolved 7 March 2003
Lifesaving
Issued 4 February 2003 Resolved
Prior to drilling conduct fire and boat drills in the presence of a CG Marine Inspector.
Due 1 July 2003
Resolved 7 March 2003
Electrical
Issued 17 February 2001 Resolved
INSTALL TWO BATTERY OPERATED E-LIGHTS IN THE PORT AND STARBOARD P TANK ROOMS.
Condition: Unknown
Due 17 February 2001
Resolved 17 February 2001
Engineering
Issued 17 February 2001 Resolved
INSTALL FLEXIBLE METALLIC COUPLING ON FUEL LINE IN THE PORT ENGINE ROOM.
Condition: Unknown
Due 17 February 2001
Resolved 17 February 2001
Fire Fighting
Issued 17 February 2001 Resolved
PROVIDE PROPER ACCESS TO PULL STATION AT CO2 BOTTLES.
Condition: Unknown
Due 17 February 2001
Resolved 17 February 2001
Electrical
Issued 17 February 2001 Resolved
REMOVE DEAD END WIRE IN OVERHEAD IN PORTSIDE ENGINE ROOM.
Condition: Unknown
Due 17 February 2001
Resolved 17 February 2001
Fire Fighting
Issued 17 February 2001 Resolved
PROVE PROPER OPERATION OF FIRE ALARM SYSTEM. FIRE ALARM PULL STATION SOUNDED ABANDON SHIP SIGNAL.
Condition: Unknown
Due 17 February 2001
Resolved 17 February 2001
Electrical
Issued 17 February 2000 Resolved
Provide closures (locks) for all power panels that are missing throughout rig.
Condition: Unknown
Due 17 February 2000
Resolved 17 February 2000
Electrical
Issued 17 February 2000 Resolved
Replace painted breaker in distribution panel located in the emergency generator room.
Condition: Unknown
Due 17 February 2000
Resolved 17 February 2000
Electrical
Issued 17 February 2000 Resolved
Provide necessary light covers for all crew bunks that are missing.
Condition: Unknown
Due 17 February 2000
Resolved 17 February 2000
Electrical
Issued 17 February 2000 Resolved
Provide junction box for telephone speaker located in the lower level change room.
Condition: Unknown
Due 17 February 2000
Resolved 17 February 2000
Electrical
Issued 17 February 2000 Resolved
Provide wire ties in support of #2 lifeboat winch.
Condition: Unknown
Due 17 February 2000
Resolved 17 February 2000
Electrical
Issued 17 February 2000 Resolved
Remove toggle switch from junction box located outside of reefer room_x001C_ (Alarm is for person trapped inside of space and shall have no means to isolate.)
Condition: Unknown
Due 17 February 2000
Resolved 17 February 2000
Fire Fighting
Issued 17 February 2000 Resolved
Provide fire hoses of sufficient length to project a jet of water to paint locker area (I.A.W. 1979 IMO Code 9.4.3 para. 1 & 2.)
Condition: Unknown
Due 17 February 2000
Resolved 17 February 2000
Electrical
Issued 17 February 2000 Resolved
Install blank cover for exposed wires located in power panel #7.
Condition: Unknown
Due 17 February 2000
Resolved 17 February 2000
Electrical
Issued 17 February 2000 Resolved
Properly secure wires in overhead with metal tie wraps within mud room.
Condition: Unknown
Due 17 February 2000
Resolved 17 February 2000
Engineering
Issued 17 February 2000 Resolved
Remove dirty oil from D/C generator space bilges and properly dispose of same.
Condition: Unknown
Due 17 February 2000
Resolved 17 February 2000
Electrical
Issued 17 February 2000 Resolved
Install blank cover or spare breaker to cover opening in power panel #8.
Condition: Unknown
Due 17 February 2000
Resolved 17 February 2000
Accommodation/Occupational Safety
Issued 17 February 2000 Resolved
Properly secure oil drums located in storage room.
Condition: Unknown
Due 17 February 2000
Resolved 17 February 2000
Electrical
Issued 15 April 1999 Resolved
REMOVE DEAD-END WIRES INSIDE DRILLERS CONSOLE ON DRILL FLOOR.
Condition: Unknown
Due 15 April 1999
Resolved 15 April 1999
Construction/Loadline
Issued 15 April 1999 Resolved
RE-AJUST DOGS ON HATCHES THROUGHOUT RIG TO ENSURE PROPER OPERATION AND CLOSURE.
Condition: Unknown
Due 15 April 1999
Resolved 15 April 1999
Electrical
Issued 15 April 1999 Resolved
ENSURE PROPER OPERATION OF EMERGENCY SHUTDOWN FOR BOTH EMD GENERATORS.
Condition: Unknown
Due 15 April 1999
Resolved 15 April 1999
Engineering
Issued 15 April 1999 Resolved
POST FUEL OIL TRANSFER PROCEDURES AT TRANSFER STATIONS.
Condition: Unknown
Due 15 April 1999
Resolved 15 April 1999
Lifesaving
Issued 15 April 1999 Resolved
PROVE MATERIAL CONDITION OF ALL FOUR PRESSURE VESSELS ON RIG(BY HYDRO TESTING TO 1.5 TIMES THE SAFETIES RELIEF SETTING) TO THE SATISFACTION OF THE AMERICAN BUREAU OF SHIPPING & PROVIDE COPY OF ABS REPORT TO THE [name withheld], TX.
Condition: Unknown
Due 15 April 1999
Resolved 15 April 1999
Construction/Loadline
Issued 30 March 1998 Resolved
MAKE STRUCTURAL AND PIPING REPAIRS IN ACCORDANCE WITH WORKLIST ISSUED ON 30MAR98 (REF NARRATIVE SUPPLEMENT). ALL REPAIRS TO BE COMPLETED TO THE SATISFACTION OF THE CLASSIFICATION SOCIETY. FINAL REPAIR SURVEY REPORT TO BE SUBMITTED TO MSO MORGAN CITY.
Condition: Unknown
Due 30 March 1998
Resolved 30 March 1998
Fire Fighting
Issued 30 March 1998 Resolved
CROP AND RENEW WASTED AND HOLED PIPING AT FIRE STATION NO. 1 AND NO. 2.
Condition: Unknown
Due 30 March 1998
Resolved 30 March 1998
Lifesaving
Issued 30 March 1998 Resolved
CONDUCT LIFEBOAT RELEASE GEAR TEST UNDER A LOAD OF 1.1 TIMES THE TOTAL MASSOF THE LIFEBOAT WHEN LOADED WITH ITS FULL COMPLEMENT OF PERSONS AND EQUIPMENT.
Condition: Unknown
Due 30 March 1998
Resolved 30 March 1998
Lifesaving
Issued 30 March 1998 Resolved
IMPLEMENT POLICY TO CONDUCT LINETHROWING APPLIANCE TRAINING EVERY THREE MONTHS AND INSPECT THE EPIRB EVERY MONTH. LOG EACH TRAINING SESSION AND EPIRB INSPECTION.
Condition: Unknown
Due 30 March 1998
Resolved 30 March 1998
Electrical
Issued 30 March 1998 Resolved
REPAIR AND CONDUCT SATISFACTORY TEST OF THE REVERSE POWER RELAY SYSTEM ON A/C GENERATOR NO. 1.
Condition: Unknown
Due 30 March 1998
Resolved 30 March 1998
Fire Fighting
Issued 30 March 1998 Resolved
PLACE FIRE RESISTANT GLOVES IN EACH FIREMAN'S OUTFIT.
Condition: Unknown
Due 30 March 1998
Resolved 30 March 1998
Accommodation/Occupational Safety
Issued 30 March 1998 Resolved
MAKE ACCOMMODATIONS MEET THE SIZE OF SLEEPING SPACES REQUIREMENTS OF 46 CFR108.201 AND THE BERTH AND LOCKER REQUIREMENTS OF 46 CFR 108.203. NOTE: NINE PERSONNEL ARE IMPROPERLY ACCOMMODATED IN A SINGLE SPACE.
Condition: Unknown
Due 30 March 1998
Resolved 30 March 1998
Lifesaving
Issued 30 March 1998 Resolved
IMPLEMENT POLICY FOR OFFSHORE INSTALLATION MANAGER TO ENTER A STATEMENT IN THE LOGBOOK STATING ADEQUATE REASONS FOR NOT CONDUCTING REQUIRED OPERATIONS(46 CFR 109.213 (h)(2)). NOTE: THE LIFEBOATS WERE NOT OPERATED IN THE WATER FROM JUNE TO DECEMBER, 1997.
Condition: Unknown
Due 30 March 1998
Resolved 30 March 1998
Accommodation/Occupational Safety
Issued 31 March 1997 Resolved
HOOK UP DRYER VENT IN LOWER LAUNDRY ROOM
Condition: Unknown
Due 10 April 1997
Resolved 5 June 1997
Fire Fighting
Issued 31 March 1997 Resolved
REPAIR/REPLACE LEAKING VALVE AT FIRE STATION #8
Condition: Unknown
Due 10 April 1997
Resolved 5 June 1997
Navigation
Issued 31 March 1997 Resolved
CLEAN RUNNING LIGHT LENSES TO PROVE PROPER OPERATION
Condition: Unknown
Due 10 April 1997
Resolved 5 June 1997
Fire Fighting
Issued 31 March 1997 Resolved
MAKE REPAIRS AS NOTED IN DEFICIENCY REPORT OF 15MAR97 TO FIRE DETECTION SYSTEM AND FIRE FIGHTING EQUIPMENT OR PROVE THEY ARE NOT REQUIRED
Condition: Unknown
Due 10 April 1997
Resolved 5 June 1997
Lifesaving
Issued 31 March 1997 Resolved
PROVIDE HYDROSTATIC TESTING OF SPARE SCBA CANNISTERS
Condition: Unknown
Due 10 April 1997
Resolved 5 June 1997
Fire Fighting
Issued 31 March 1997 Resolved
REPAIR LEAK TO VALVE ON FIRE STATION #5.
Condition: Unknown
Due 10 April 1997
Resolved 5 June 1997
Engineering
Issued 31 March 1997 Resolved
REPLACE CRACKED FUEL LINES ON ALL GENERATORS
Condition: Unknown
Due 10 April 1997
Resolved 5 June 1997
Engineering
Issued 31 March 1997 Resolved
PROVE OPERATION OF REMOTE SHUTDOWN FOR FUEL OIL SHUTDOWN PUMPS
Condition: Unknown
Due 10 April 1997
Resolved 5 June 1997
Electrical
Issued 31 March 1997 Resolved
PLACE BLANK OVER MISSING BREAKER IN PANEL ON EMERGENCY GENERATOR SWITCHBOARD
Condition: Unknown
Due 10 April 1997
Resolved 5 June 1997
Fire Fighting
Issued 31 March 1997 Resolved
LABEL ALL ALARM LIGHTS AND BELLS OR HORNS PROPERLY
Condition: Unknown
Due 10 April 1997
Resolved 5 June 1997
Fire Fighting
Issued 31 March 1997 Resolved
REPAIR ALL WASTED FIREMAIN AND SALTWATER PIPING TO THE FIREMAIN SYSTEM AND HAVE CLASS INSPECT REPAIRS. SUBMIT REPORT FROM CLASS TO COAST GUARD OF APPROVED REPAIRS.
Condition: Unknown
Due 10 April 1997
Resolved 5 June 1997
Accommodation/Occupational Safety
Issued 31 March 1997 Resolved
LOG DISCHARGES OF FOOD WASTE IN GARBAGE DISCHARGE LOG
Condition: Unknown
Due 10 April 1997
Resolved 5 June 1997
Construction/Loadline
Issued 31 March 1997 Resolved
PROVIDE GASKET AND REPAIR KNIFE EDGE HATCH COAMING TO STBD SACK ROOM HATCH
Condition: Unknown
Due 10 April 1997
Resolved 5 June 1997
Unknown
Issued 31 March 1997 Resolved
AT NEXT RIG MOVE TEST OPERATION OF TOTAL RIG SHUTDOWN
Condition: Unknown
Due 10 April 1997
Resolved 5 June 1997
Lifesaving
Issued 31 March 1997 Resolved
PROVIDE LIGHTSTICKS FOR BOTH LIFEBOAT COMPASSES
Condition: Unknown
Due 10 April 1997
Resolved 5 June 1997
Lifesaving
Issued 31 March 1997 Resolved
PROVIDE REPLACEMENT PROVISIONS FOR 8 REJECTED (#2 LIFEBOAT), 9 REJECTED(#1 LIFEBOAT
Condition: Unknown
Due 10 April 1997
Resolved 5 June 1997
Lifesaving
Issued 31 March 1997 Resolved
REMOVE LINE FROM QUICK RELEASE RING BUOY STATIONS, MOVE TO MAIN DECK RING BUOY STATIONS.
Condition: Unknown
Due 10 April 1997
Resolved 5 June 1997
Lifesaving
Issued 10 April 1996 Resolved
LABEL ALL ALARMS AND SIRENS (AUDIBLE AND VISUAL).
Condition: Unknown
Due 11 May 1996
Resolved 4 June 1996
Electrical
Issued 10 April 1996 Resolved
RESOLVE ALL EXCESSIVE OIL LEAKS ON BOTH AC GENERATORS.
Condition: Unknown
Due 13 July 1996
Resolved 13 July 1996
Fire Fighting
Issued 10 April 1996 Resolved
PROVIDE OPERATING INTRUCTIONS AT CO2 CYLINDERS FOR MACHINERY SPACES.
Condition: Unknown
Due 11 May 1996
Resolved 4 June 1996
Construction/Loadline
Issued 10 April 1996 Resolved
REPAIR SPRUNG WATERTIGHT DOOR #20 AND #28 PRIOR TO NEXT RIG MOVE.
Condition: Unknown
Due 13 July 1996
Resolved 13 July 1996
Documentation
Issued 10 April 1996 Resolved
PROVIDE A LIST OF ALL EXEMPTIONS GRANTED BY PANAMA FOR THE RIG'S IMO MODU CODE.
Condition: Unknown
Due 13 July 1996
Resolved 13 July 1996
Accommodation/Occupational Safety
Issued 10 April 1996 Resolved
REPAIR/REPLACE DAMAGED EMERGENCY ESCAPE LADDER ON STBD BOW.
Condition: Unknown
Due 11 May 1996
Resolved 4 June 1996
Construction/Loadline
Issued 10 April 1996 Resolved
REPAIR/REPLACE WASTED BULKHEAD TO PAINT LOCKER.
Condition: Unknown
Due 11 May 1996
Resolved 4 June 1996
Fire Fighting
Issued 10 April 1996 Resolved
PROVIDE PANTS FOR FIREMAN'S OUTFITS.
Condition: Unknown
Due 25 April 1996
Resolved 4 June 1996
Fire Fighting
Issued 10 April 1996 Resolved
PROVIDE REPORT FROM CLASS SOCIETY ON REPAIRS AND SUBSEQUENT TESTING OF FIXED CO2 SYSTEM FOR MACHINERY SPACES.
Condition: Unknown
Due 13 July 1996
Resolved 13 July 1996
Fire Fighting
Issued 10 April 1996 Resolved
REPAIR HOLES IN CO2 BRANCH LINE BY MUDPIT ROOM WATERTIGHT DOOR #6.
Condition: Unknown
Due 13 July 1996
Resolved 13 July 1996
Construction/Loadline
Issued 10 April 1996 Resolved
PLUG OPEN BULKHEAD PENETRATIONS (2) BY MUDPIT ROOM WATERTIGHT DOOR #6.
Condition: Unknown
Due 13 July 1996
Resolved 13 July 1996
Accommodation/Occupational Safety
Issued 10 April 1996 Resolved
LABEL CONTROLLERS FOR BOTH FIRE PUMPS.
Condition: Unknown
Due 13 July 1996
Resolved 13 July 1996
Fire Fighting
Issued 10 April 1996 Resolved
RESOVLE LEAKING NOZZLE AND VALVE STEM AT FIRE STATION #10.
Condition: Unknown
Due 13 July 1996
Resolved 13 July 1996
Fire Fighting
Issued 10 April 1996 Resolved
REPAIR/REPLACE PARTS AS NECESSARY TO MAKE FIXED CO2 SYSTEM FOR MACHINERY SPACES OPERATIONAL.
Condition: Unknown
Due 16 April 1996
Resolved 4 June 1996
Fire Fighting
Issued 10 April 1996 Resolved
TEST ALL HEAT DETECTORS IN MACHINERY SPACES.
Condition: Unknown
Due 13 July 1996
Resolved 13 July 1996
Navigation
Issued 10 April 1996 Resolved
REPAIR FAULTY OBSTRUCTION LIGHT ON PORT LEG.
Condition: Unknown
Due 11 May 1996
Resolved 4 June 1996
Electrical
Issued 10 April 1996 Resolved
REPAIR/REPLACE BROKEN LATCH TO ELECTRICAL PANEL "EL1-9" ON MAINDECK OF QUARTERS.
Condition: Unknown
Due 11 May 1996
Resolved 4 June 1996
Fire Fighting
Issued 10 April 1996 Resolved
PROVIDE WHEELED CO2 EXTINGUISHER ON HELODECK IN ACCORDANCE WITH IMO MODE CODE.
Condition: Unknown
Due 11 May 1996
Resolved 4 June 1996
Accommodation/Occupational Safety
Issued 10 April 1996 Resolved
REPLACE WASTED DECK PLATING AT BASE OF EMERGENCY ESCAPE LADDER ON PORT LEG.
Condition: Unknown
Due 11 May 1996
Resolved 4 June 1996
Electrical
Issued 10 April 1996 Resolved
INSTALL AN EMERGENCY LIGHT IN PORTSIDE QUARTERS MAINDECK PASSAGEWAY.
Condition: Unknown
Due 13 July 1996
Resolved 13 July 1996
Fire Fighting
Issued 10 April 1996 Resolved
CROP AND RENEW WASTED FIREMAIN PIPING AT FIRE STATION #6.
Condition: Unknown
Due 13 July 1996
Resolved 13 July 1996
Fire Fighting
Issued 10 April 1996 Resolved
REPLACE AS NECESSARY ALL EXCESSIVELY SCRATCHED LENS TO SELF-CONTAINED BREATHING APPARTUSES.
Condition: Unknown
Due 11 May 1996
Resolved 4 June 1996
Accommodation/Occupational Safety
Issued 10 April 1996 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 11 May 1996
Resolved 4 June 1996
Lifesaving
Issued 10 April 1996 Resolved
DETERMINE CONDITION AND SERVICEABILITY OF WASTED PORTSIDE LIFEBOAT DAVIT STRUCTURE AND PROVIDE SUBSEQUENT REPORT TO MSO PORT ARTHUR.
Condition: Unknown
Due 11 May 1996
Resolved 4 June 1996
Lifesaving
Issued 10 April 1996 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 11 May 1996
Resolved 4 June 1996
Electrical
Issued 21 April 1995 Resolved
REPAIR RED ROTATING WARNING BEACON FOR GENERAL ALARM SYSTEM IN EMD MOTOR ROOM SPACE.
Condition: Unknown
Due 1 July 1995
Resolved 24 May 1995
Electrical
Issued 21 April 1995 Resolved
INSTALL WARNING PLACARDS BY RED WARNING ROTATING BEACONS STATING "WHEN THE GENERAL ALARM SOUNDS GO TO YOUR STATIONS".
Condition: Unknown
Due 1 July 1995
Resolved 24 May 1995
Construction/Loadline
Issued 21 April 1995 Resolved
REMOVE EXCESSIVE AMOUNT OF OIL AND WATER IN MOTORROOM BILGES AND UNDER MAINGENERATOR UNITS.
Condition: Unknown
Due 1 July 1995
Resolved 24 May 1995
Electrical
Issued 21 April 1995 Resolved
INSTALL A GENERAL ALARM BELL OR A RED WARNING ROTATING BEACON LIGHT FIXTUREBY NUMBER 2 EMD GENERATOR.
Condition: Unknown
Due 1 July 1995
Resolved 24 May 1995
Fire Fighting
Issued 21 April 1994 Resolved
Install new CO2 horn for mud room.
Condition: Unknown
Due 23 May 1994
Resolved 23 May 1994
Unknown
Issued 21 April 1994 Resolved
Submit cover sheet of approved construction portfolio.
Condition: Unknown
Due 21 April 1994
Resolved 21 April 1994
Unknown
Issued 21 April 1994 Resolved
Provide documentation from class society for port crane inspection status.
Condition: Unknown
Due 23 May 1994
Resolved 23 May 1994
Unknown
Issued 21 April 1994 Resolved
Repair outboard side of port crane deck walk.
Condition: Unknown
Due 23 May 1994
Resolved 23 May 1994
Fire Fighting
Issued 19 March 1993 Resolved
INSTALL MISSING CO2 CYLINDAR FOR FIXED SYSTEM IN ENGINE ROOM.
Condition: Unknown
Due 24 March 1993
Resolved 24 March 1993
Lifesaving
Issued 19 March 1993 Resolved
PROVE FLAG STATE ACCEPTANCE OF PROVISIONS, EQUIPMENT, STRUCTURE, AND WINCHES FOR BOTH LIFEBOATS.
Condition: Unknown
Due 19 March 1993
Resolved 19 March 1993
Unknown
Issued 19 March 1993 Resolved
CLEAR ALL OUTSTANDING REQUIREMENTS ISSUED TO PREVIOUS OWNER/OPERATOR; REFERENCE CASES MI89033493 AND MI91032739.
Condition: Unknown
Due 19 March 1993
Resolved 19 March 1993
Electrical
Issued 19 March 1993 Resolved
PROVE PROPER OPERATION OF LOSS OF PURGE ALARMS FOR ELECTRICAL EQUIPMENT ON DRILLER'S CONSOLE AND DRILL FLOOR.
Condition: Unknown
Due 19 March 1993
Resolved 19 March 1993
Lifesaving
Issued 19 March 1993 Resolved
PROVE FLAG STATE ACCEPTANCE OF STBD LIFE BOAT AND DAVIT WEIGHT TEST.
Condition: Unknown
Due 19 March 1993
Resolved 19 March 1993
Lifesaving
Issued 19 March 1993 Resolved
PUT ALL PROVISIONS/EQUIPMENT IN LIFEBOATS.
Condition: Unknown
Due 19 March 1993
Resolved 19 March 1993
Electrical
Issued 19 March 1993 Resolved
PROVE PROPER OPERATION OF EMERGENCY GENERATOR OVERSPEED TRIP.
Condition: Unknown
Due 19 March 1993
Resolved 19 March 1993
Fire Fighting
Issued 31 October 1991 Resolved
PROVIDE PROPER SEAL FOR PAINT LOCKER AROUND DOOR AND HOLES IN SIDE BULKHEAD._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 October 1991
Resolved 31 October 1991
Deck/Cargo
Issued 31 October 1991 Resolved
PROVIDE CRANE CERTIFICATES INDICATING ANNUAL AND FIVE YEAR LOAD TEST INSPECTION._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 October 1991
Resolved 31 October 1991
Documentation
Issued 31 October 1991 Resolved
REVISE THE OPERATION MANUAL TO MEET 46 CFR 109.121._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 October 1991
Resolved 31 October 1991
Fire Fighting
Issued 31 October 1991 Resolved
PROPERLY CALIBRATE BOTH OXYGEN METERS REQUIRED FOR THE FIREMAN'S OUTFITS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 October 1991
Resolved 31 October 1991
Lifesaving
Issued 31 October 1991 Resolved
PROPERLY LABEL ALL REQUIRED INFORMATION ON #1 AND #2 LIFEBOATS WITH 3 INCHLETTERS WITH EXCEPTION OF 1.5 INCH LETTERS FOR BOAT CAPACITY._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 October 1991
Resolved 31 October 1991
Lifesaving
Issued 31 October 1991 Resolved
REPAIR LIMIT SWITCHES ON #1 LIFEBOAT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 October 1991
Resolved 31 October 1991
Deck/Cargo
Issued 31 October 1991 Resolved
MAKE APPROVED REPAIRS TO EXCESSIVE PITTING ON BULK TANKS LOCATED ON THE UPPER DECK. PROVIDE CERTIFICATES OF QUALIFIED WELDERS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 October 1991
Resolved 31 October 1991
Engineering
Issued 31 October 1991 Resolved
PROVIDE PROOF OF INTERNAL INSPECTION OR HYDROSTATIC TEST OF ALL PRESSURE VESSELS AND TESTING OF RELIEF VALVES BY ABS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 October 1991
Resolved 31 October 1991
Fire Fighting
Issued 31 October 1991 Resolved
PROVIDE GAUGING REPORT OF ALL THE FIRE MAIN PIPING IN THE AREA OF THE PRIMARY FIRE PUMP._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 October 1991
Resolved 31 October 1991
Documentation
Issued 31 October 1991 Resolved
UPDATE HAZARDOUS LOCATION PLAN TO INDICATE ENTIRE DRILL FLOOR AS CLASS I DIVISION II AREA EXCEPT FOR FIVE (5) FOOT RADIUS AROUND ROTARY TABLE WHICH WILL INDICATE A CLASS I DIVISION I AREA. _x001C_ _x001C_
Condition: Unknown
Due 31 October 1991
Resolved 31 October 1991
Unknown
Issued 6 December 1990 Resolved
PLACE ONBOARD FLOAT FREE SURVIVAL CRAFT PER IMO CODE SECTION 10.1.1.2 FOR 100 PERCENT OF PERSONS ALLOWED ONBOARD.
Condition: Unknown
Due 6 December 1990
Resolved 6 December 1990
Unknown
Issued 24 October 1990 Resolved
MAKE PERMANENT REPAIRS TO PORT CRANE RAILING WHERE WASTED.
Condition: Unknown
Due 24 October 1990
Resolved 24 October 1990
Unknown
Issued 24 October 1990 Resolved
REMOVE LOCK-BACK MECHANISMS FROM SELF-CLOSING WATERTIGHT DOORS IN MUDPIT ROOM.
Condition: Unknown
Due 24 October 1990
Resolved 24 October 1990
Unknown
Issued 24 October 1990 Resolved
PLACE ONBOARD FLOAT FREE SURVIVAL CRAFT PER IMO MODU CODE SEC.10.1.1.2 FOR 100 PERCENT OF PERSONS ALLOWED ONBOARD, OR PRESENT FROM HOME ADMINISTRATIONDOCUMENTATION THAT PRESENT ARRANGEMENT IS EQUIVALENT TO OR IS EXEMPT FROM IMO MODU CODE REQUIREMENT.
Condition: Unknown
Due 24 October 1990
Resolved 24 October 1990
Unknown
Issued 24 October 1990 Resolved
REPLACE ALL PLASTIC FIRE HOSES WITH RUBBER LINED AND UL/FM APPROVED.
Condition: Unknown
Due 24 October 1990
Resolved 24 October 1990
Electrical
Issued 24 October 1989 Resolved
PROPERLY END THE STANDBY GENERATOR HEATER CABLES.
Condition: Unknown
Due 24 October 1989
Resolved 24 October 1989
Electrical
Issued 24 October 1989 Resolved
REPAIR THE KICK PIPES ON THE PORT SIDE OF THE DRILL HOUSE.
Condition: Unknown
Due 24 October 1989
Resolved 24 October 1989
Electrical
Issued 24 October 1989 Resolved
REPAIR THE KICK PIPE FOR MUD SUPPLY FAN.
Condition: Unknown
Due 24 October 1989
Resolved 24 October 1989
Accommodation/Occupational Safety
Issued 24 October 1989 Resolved
SUPPLY APPROVED SAFETY BELTS.
Condition: Unknown
Due 24 October 1989
Resolved 24 October 1989
Deck/Cargo
Issued 24 October 1989 Resolved
MAKE CRANES AVALABLE FOR ANNUAL INSPECTION.
Condition: Unknown
Due 24 October 1989
Resolved 24 October 1989
Electrical
Issued 24 October 1989 Resolved
PROVIDE LOSS OF PURGE ALARMS ON THE 480V EXPLOSION PROOF STYLE & JUCTION BOXES ON THE DRILL FLOOR.
Condition: Unknown
Due 24 October 1989
Resolved 24 October 1989
Documentation
Issued 24 October 1989 Resolved
PROVIDE AN APPROVED CONSTRUCTION PORTFOLIE.
Condition: Unknown
Due 24 October 1989
Resolved 24 October 1989
Electrical
Issued 24 October 1989 Resolved
INSTALL AND POUR EYS ON THE MOTOR
Condition: Unknown
Due 24 October 1989
Resolved 24 October 1989
Construction/Loadline
Issued 24 October 1989 Resolved
REPAIR THE SOUNDING TUBE ON THE STBD SIDE OF THE MAIN DECK.
Condition: Unknown
Due 24 October 1989
Resolved 24 October 1989
Electrical
Issued 24 October 1989 Resolved
POUR THE EYS FITTING ON THE #2 SHALE SHAKER MOTOR
Condition: Unknown
Due 24 October 1989
Resolved 24 October 1989
Fire Fighting
Issued 24 October 1989 Resolved
HYDROSTATIC TEST THE CO2 BOTTLES FOR THE PAINT LOCKER AND GREASE LOCKER FLOOR SYSTEM.
Condition: Unknown
Due 24 October 1989
Resolved 24 October 1989
Electrical
Issued 24 October 1989 Resolved
INSTALL A LOSS OF PURGE ALARM ON THE DRILL FLOOR SOUND POWERED PHONE.
Condition: Unknown
Due 24 October 1989
Resolved 24 October 1989
Electrical
Issued 24 October 1989 Resolved
REPAIR OR RENEW THE GAS DETECTOR PANEL LOSS OF PURGE ALARM ON THE DRILL FLOOR.
Condition: Unknown
Due 24 October 1989
Resolved 24 October 1989
Electrical
Issued 24 October 1989 Resolved
INSTALL AND POUR A TRIPLE PUMP STARTER EYS (KOOMEY)
Condition: Unknown
Due 24 October 1989
Resolved 24 October 1989
Electrical
Issued 24 October 1989 Resolved
INSTALL A LOSS OF PURGE ALARM ON THE AMP METER BOX ON THE DRILLERS CONSOLE.
Condition: Unknown
Due 24 October 1989
Resolved 24 October 1989
Electrical
Issued 24 October 1989 Resolved
PROVIDE A LOSS OF PURGE ALARM ON THE SOUND POWERED PHONE IN THE SHALE SHAKER AREA.
Condition: Unknown
Due 24 October 1989
Resolved 24 October 1989
Unknown
Issued 6 December 1988 Resolved
REPAIR LEAK IN SALT WATER LINE IN STARBOARD SACK STORAGE ROOM.
Condition: Unknown
Due 6 December 1988
Resolved 6 December 1988
Unknown
Issued 6 December 1988 Resolved
MOVE ALL NON EXPLOSIVE PROOF EQUIPMENT BEYOND 10 FT FROM THE MUD PIT DOORS;MOVE AGITATOR CONTROLLER ON PORT SIDE AND OUTLET ON THE STARBOARD SIDE.
Condition: Unknown
Due 6 December 1988
Resolved 6 December 1988
Unknown
Issued 6 December 1988 Resolved
CORRECT THE PRESSURE PROBLEM WITH THE #3 FIRE HOSE STATION PIPING OR GATE VALVE.
Condition: Unknown
Due 6 December 1988
Resolved 6 December 1988
Construction/Loadline
Issued 25 October 1988 Resolved
NON-SKID THE HELO DECK.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Deck/Cargo
Issued 25 October 1988 Resolved
CHANGE THE FUEL LINES ON THE TWO CRANES TO AN APPROVED HOSE FOR FUEL OIL SERVICE WHICH IS FIRE PROOF.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Unknown
Issued 25 October 1988 Resolved
CLEAN THE GREASE TRAP AND DUCT WORK FOR THE GALLEY HOOD.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Unknown
Issued 25 October 1988 Resolved
OPEN FOR INTERNAL INSPECTION THE FOLLOWING AIR RECEIVERS: NO.3 CEMENT, NO.1 & 4 DRY MUD, AND THE DRILL FLOOR AIR RECEIVER.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Electrical
Issued 25 October 1988 Resolved
MAKE ALL WIRING IN THE MUD PIT SUITABLE FOR CLASS I DIV I (ARMORED). HAZARDOUS AREA PLAN STANDARD IS API 500.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Unknown
Issued 25 October 1988 Resolved
REPLACE MISSING DOGS ON CEMENT TANKS.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Electrical
Issued 25 October 1988 Resolved
DEMONSTRATE OPERATION OF LOCAL AND REMOTE SHUT OFFS FOR MOST FORWARD FUEL PUMP.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Electrical
Issued 25 October 1988 Resolved
PROVIDE BLANKS FOR 120-208V DISTRIBUTION PANEL.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Fire Fighting
Issued 25 October 1988 Resolved
CORRECT THE PRESSURE PROBLEM WITH THE #3 FIRE HOSE STATION PIPING OR GATE VALVE.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Documentation
Issued 25 October 1988 Resolved
PRESENT OIL RECORD BOOK, OIL TRANSFER PROCEDURES DOCUMENTATION OF HYDROSTATIC TEST OF OIL TRANSFER HOSES, AND DESIGNATED PERSON IN CHARGE AS REQUIRED BY 33 CFR 151 & 33 CFR 155.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Electrical
Issued 25 October 1988 Resolved
REPAIR REVERSE POWER RELAY FOR #2 GENERATOR.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Electrical
Issued 25 October 1988 Resolved
REMOVE ALL DISCONNECTED WIRING OVER THE DRILLERS CONSOLE.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Electrical
Issued 25 October 1988 Resolved
DEMONSTRATE THE PROPER OPERATION OF THE #2 GENERATOR.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Unknown
Issued 25 October 1988 Resolved
ULTRASONICALLY GAUGE THE PITTED AREAS ON TOP OF CEMENT TANKS. PROVIDE U1A FORMS ON CONSTRUCTION DATA SCANTLING.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Electrical
Issued 25 October 1988 Resolved
MAKE ALL BULKHEAD PENETRATIONS IN THE MUD PIT SUITABLE FOR CLASS I DIV I.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Unknown
Issued 25 October 1988 Resolved
PROVIDE AIR PURGE FOR SHELL SHAKER AREA PHONE.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Unknown
Issued 25 October 1988 Resolved
REPAIR LEAK IN SALT WATER LINE IN STARBOARD SACK STORAGE ROOM
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Electrical
Issued 25 October 1988 Resolved
MOVE ALL NON EXPLOSIVE PROOF EQUIPMENT BEYOND 10 FT FROM THE MUD PIT DOORS;MOVE AGITATOR CONTROLLER ON PORT SIDE AND OUTLET ON THE STARBOARD SIDE.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Construction/Loadline
Issued 25 October 1988 Resolved
RENEW SUPPORTS FOR FENDER BASKETS.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Construction/Loadline
Issued 25 October 1988 Resolved
REPLACE HINGE PINS AS NECESSARY ON THE WATER TIGHT HATCHES ON THE MAIN DECK.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Electrical
Issued 25 October 1988 Resolved
PROVIDE SUITABLE POWER SUPPLY CABLE FOR THE LOGGERS SHACK.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Electrical
Issued 25 October 1988 Resolved
SECURE ALL WIRES ABOVE THE DRILLERS CONSOLE WITH METAL BANDING. 5/8 INCH BANDS ARE REQUIRED FOR PVC TYPE CABLES.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Documentation
Issued 25 October 1988 Resolved
RESUBMIT THE OPERATIONS MANUAL TO THE FLAG STATE REPRESENTATIVE FOR REAPPROVAL.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Fire Fighting
Issued 24 October 1987 Resolved
PROVIDE EVIDENCE THAT THE DISCHARGE HOSE ON THE DELO DECK B-V FIRE EXTINGUISHER WAS SATISFATORILY TESTED PER 46 CFR 147 OR REPLACE THE SAME APPROPIATELY.
Condition: Unknown
Due 24 October 1987
Resolved 24 October 1987
Fire Fighting
Issued 24 October 1987 Resolved
DEMONSTRATE A PETOT TUBE PRESSURE READING OF NOT LESS THAN FORTY PSI WHILE TWO HYDRANTS ARE DISHCARGNG SIMULTANEOUSLY.
Condition: Unknown
Due 24 October 1987
Resolved 24 October 1987
Electrical
Issued 24 October 1987 Resolved
PROVE PROPER OPERATION OF THE STAND BY GENERATOR AND CONDUCT TWO HOUR REQUIRED TESTING UNDER LOAD.
Condition: Unknown
Due 24 October 1987
Resolved 24 October 1987
Fire Fighting
Issued 24 October 1987 Resolved
PROVIDE EVIDENCE DEMONSTRATING THAT THE NITROGEN BOTTLE FOR THE HELO DECK B-V FIRE EXTINGUISHER HAS BEEN HYDROSTATICALLY TESTED.
Condition: Unknown
Due 24 October 1987
Resolved 24 October 1987
Electrical
Issued 24 October 1987 Resolved
MAKE THE LOSS OF PURGE ALARM ON THE DRILLERS CONSOLE OPERABLE.
Condition: Unknown
Due 24 October 1987
Resolved 24 October 1987
Lifesaving
Issued 24 October 1987 Resolved
PROVIDE EVIDENCE INDICATING THAT THE CARBON DIOXIDE INFLATION CYLINDERS FOR THE RIGHTING BAG ON BOTH (PORT AND STARBOARD) CAPSULES HAVE BEEN SATISFACTORILY HYDROSTATICALLY TESTD.
Condition: Unknown
Due 24 October 1987
Resolved 24 October 1987
Fire Fighting
Issued 24 October 1987 Resolved
REPLACE EX-607 (2Q80) HOSE ON B-V FIRE EXTINGUISHER FOR HELO DECK WITH SWITCHABLE HOSE. (THIS APPLIES TO NEW UNIT, NOT THE B-V MENTIONED IN ITEM 3)
Condition: Unknown
Due 24 October 1987
Resolved 24 October 1987
Lifesaving
Issued 24 October 1985 Resolved
PROVIDE 12 PARACHUTE FLARES TO LIFEBOAT #1. 46 CFR 108.503.
Condition: Unknown
Due 24 October 1985
Resolved 24 October 1985
Lifesaving
Issued 24 October 1985 Resolved
PROVIDE 150 FOUR OZ WATER PACKETS TO LIFEBOAT #1 AND #2. 46 CFR 108.503.
Condition: Unknown
Due 24 October 1985
Resolved 24 October 1985
Navigation
Issued 24 October 1985 Resolved
MAKE OPERATIONAL THE NORTHEAST CORNER OBSTRUCTION LIGHT. COLREGS 33 CFR 81.
Condition: Unknown
Due 24 October 1985
Resolved 24 October 1985
Lifesaving
Issued 24 October 1985 Resolved
PROVIDE BEWARE OF THE TAIL ROTOR AT EACH ACCESS TO THE HELO DECK. 46 CFR 108.653(C).
Condition: Unknown
Due 24 October 1985
Resolved 24 October 1985
Lifesaving
Issued 24 October 1985 Resolved
MAKE PERMANENT REPAIRS TO FORWARD FLIGHT DECK NETTING. 46 CFR 108.235(C).
Condition: Unknown
Due 24 October 1985
Resolved 24 October 1985
Deck/Cargo
Issued 24 October 1985 Resolved
PROVIDE AN OPERATIONAL BOOM ANGLE INDICATOR. 46 CFR 108.601.
Condition: Unknown
Due 24 October 1985
Resolved 24 October 1985
Deck/Cargo
Issued 24 October 1985 Resolved
MAKE OPERATIONAL FUEL OIL TRANSFER PUMP REMOTE SHUTDOWN. 46 CFR 58.01.
Condition: Unknown
Due 24 October 1985
Resolved 24 October 1985
Lifesaving
Issued 24 October 1985 Resolved
RENEW LIFEBOAT FALLS ON #1 AND #2 LIFEBOAT. 46 CFR 108.507
Condition: Unknown
Due 24 October 1985
Resolved 24 October 1985
Construction/Loadline
Issued 24 October 1985 Resolved
RENEW THE SALT WATER COOLING SUPPLY LINES ON BOTH EMD DIESELS. 46 CFR 58.10.
Condition: Unknown
Due 24 October 1985
Resolved 24 October 1985
Electrical
Issued 24 October 1985 Resolved
MAKE OPERATIONAL THE VENTILATION REMOTE SHUTDOWN. 46 CFR 111.103.
Condition: Unknown
Due 24 October 1985
Resolved 24 October 1985
Lifesaving
Issued 24 October 1985 Resolved
PROVIDE ONE LIFE PRESERVER TO LIFEBOAT #2. 46 CFR 108.503.
Condition: Unknown
Due 24 October 1985
Resolved 24 October 1985
Fire Fighting
Issued 30 October 1984 Resolved
MAKE PERMANENT REPAIRS TO FIXED CO2 EXTINGUISHER SYSTEM SERVING MACHINERY SPACES.
Condition: Unknown
Due 30 October 1984
Resolved 30 October 1984
Unknown
Issued 30 October 1984 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE MODU TELEDYNE RIG 17, O.N. NEW002THE BELOW LISTED ITEMS ARE TO BE COMPLIED WITH BY 30 NOVEMBER 1984.
Condition: Unknown
Due 30 October 1984
Resolved 30 October 1984
Lifesaving
Issued 30 October 1984 Resolved
PROVIDE TWELVE (12) HAND HELD PARACHUTE FLARES AND WATERTIGHT STORAGE CON- TAINMENT. 46 CFR 108.521.
Condition: Unknown
Due 30 October 1984
Resolved 30 October 1984
Lifesaving
Issued 30 October 1984 Resolved
PROVIDE THE FOLLOWING EQUIPMENT FOR THE NO. 1 LIFEBOAT: SIGNAL MIRROR, 450 CANS OF WATER, BOARDING LADDER, 46 CFR 94.20-10.
Condition: Unknown
Due 30 October 1984
Resolved 30 October 1984
Electrical
Issued 30 October 1984 Resolved
REPAIR OR REPLACE GENERAL ALARM BELLS AT PORT STERN TACKING HOUSE, AFTER QUATERS SUPERSTRUCTURE AND MUD PITS.
Condition: Unknown
Due 30 October 1984
Resolved 30 October 1984
Lifesaving
Issued 30 October 1984 Resolved
PROVIDE THE FOLLOWING EQUIPMENT FOR THE NO. 2 LIFEBOAT: 450 CANS OF WATER, BOARDING LADDER.
Condition: Unknown
Due 30 October 1984
Resolved 30 October 1984
Unknown
Issued 14 April 1983 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL TELEDYNE RIG 17, VIN= NEW002
Condition: Unknown
Due 14 April 1983
Resolved 14 April 1983
Unknown
Issued 14 April 1983 Resolved
SUBMIT PROPOSAL FOR PERMANENT REPAIR OF GAUGING IN BOW LEG (AT 166 LEVEL) TO [name withheld].
Condition: Unknown
Due 14 April 1983
Resolved 14 April 1983
Unknown
Issued 14 April 1983 Resolved
MAKE PORT MUD PIT DUMP VALVE AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 14 April 1983
Resolved 14 April 1983
Unknown
Issued 14 April 1983 Resolved
SUBMIT COPY OF GAUGING REPORT FOR RIG LEGS (AT 35 FT. AND 45 FT LEVEL) AND NO. 3P TANK (BULKHEAD COMMON TO ACTIVE MUD PIT) TO [name withheld].
Condition: Unknown
Due 14 April 1983
Resolved 14 April 1983
Unknown
Issued 14 April 1983 Resolved
CONDUCT UNDERWATER INSPECTION OF MAT SIDES, SKIRT AND BOTTOM.
Condition: Unknown
Due 14 April 1983
Resolved 14 April 1983

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.