MAURY USCG vessel records Sign in
← All vessels

MUSASHI GLORIA

MUSASHI GLORIA is a 1992 tank ship. The Coast Guard has recorded 9 inspections since 1994, most recently in October 2004, along with 5 deficiencies and 4 operational controls.

Records from 1994 to 2004. Most recent: inspection, 14 October 2004.

Built
1992
Last inspected
14 October 2004
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9012886 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
387929
Flag
JAPAN
—
Maury page id
psix-387929

Inspections, by type

…with no type recorded4
Years with a record 3 calendar years (1994–2004)
The 9 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 22 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it42341 - Convention (Subpart B), Gross Ton
15519 - Convention (Subpart B), Net Ton
49255 - Dead Weight, Ton
66138 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 9

14 October 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2221030
14 October 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2221056
1 October 2004 COC-GAS Annual · ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2211138
27 October 2003 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1937469
17 September 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1906863
12 August 2003 Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1875981
3 October 1994 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 370918
3 October 1994 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 862605
3 October 1994 Letter of Compliance (Initial/Renewal)
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1363109

Deficiency record · 5

Pollution Prevention/Response › Prevention Equipment
Issued 12 August 2003 Resolved
Repair and prove operation of the OWS 15ppm sensor and alarm to the satisfaction of the Flag Administration. MARPOL Annex I LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 August 2003
Resolution: Rcvd NKK class report.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 12 August 2003 Resolved
Repair airlock doors for motor room to ensure they are self closing and gas tight. IGC 3.6
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 August 2003
Resolution: Rcvd NKK class report.
Deck/Cargo
Issued 12 August 2003 Resolved
Calibrate and prove proper operation of the fixed gas detection system. IGC 13.6.6
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 August 2003
Resolution: Rcvd NKK class report.
Documentation › Certificates/Documents
Issued 12 August 2003 Resolved
Correct SOLAS Safety Equipment Cert. Record of Equipment to reflect the liferaft required by SOLAS III/31.1.4. LEGACY COMPONENT DESC: Cargo Ship Safety Equipment Certificate
Action required: 15 - Rectify deficiencies by next port
Resolved 15 August 2003
Resolution: Rcvd NKK class report.
Engineering › Fuel Oil Storage/Transfer System
Issued 12 August 2003 Resolved
Install remote fuel cut-off valve for emergency generator fuel tank. Tank cap. >500 L SOLAS II-2/15.2.5, SOLAS interpretations FP42/7/1 LEGACY COMPONENT DESC: Valve
Action required: 15 - Rectify deficiencies by next port
Resolved 15 August 2003
Resolution: Rcvd NKK class report of remote valve installation.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.