Records from 1998 to 2009. Most recent: operational control imposed, 31 July 2009.
Inspection history · 11
30 July 2009
Deficiency Check · ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3549983
2 February 2007
MARPOL Annex I Examination · Ballast Water Examination · PII Safety Exam · MARPOL Annex V Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2865958
12 January 2004
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1982893
8 May 2003
Annual Inspection · Ballast Water Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1789488
11 January 2002
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1477844
8 January 2002
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1474723
14 May 2000
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 277843
9 June 1999
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 429508
2 February 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 52975
2 February 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 424883
5 June 1998
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 417075
Lifesaving › Lifeboat › Propulsion Starting System
Issued 30 July 2009
Resolved
Starboard lifeboat motor found not able to start. Prove proper opwration of both port & starboard life boats to the satisfaction of attending class surveyor. Vessel crew used parts of port lifeboat to fix starboard lifeboat. SOLAS 74 amd. (2004 cons ed) Chapter III, Reg. 31 Action: 30a
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 August 2009
Resolution: PSCO attended vessel with Flag Representative and verified proper operation of both lifeboats motors in the water.
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 30 July 2009
Resolved
Emergency generator has soft patch on main lube oil supply line. Vessel to make permanent repairs to main lube oil line to satisfaction of attending class surveyor. SOLAS 74 amd. (2004 cons ed) Chapter I, Reg. 11 Action: 30a
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 August 2009
Resolution: Class and Flag reports recieved attesting to permanent repair made to the piping.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 30 July 2009
Resolved
Oily water separator auto stop device (3-way valve) not operable. upon 15 PPM alarm system would continue to pump oily water mixture overboard. Prove proper operation oily water separator and automatic stopping device to the satisfaction of attending class surveyor. MARPOL 73/78 Annex I, Reg. 14.7 Action: 30a
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 August 2009
Resolution: PSCO attended vessel with Flag Representative and verified proper operation.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 30 July 2009
No resolution recorded
Vessel failed to follow the Safety Management System with regard to reporting leaking shaft seal, holed lube oil line on emergency generator, damaged windows, holes in main deck and inoperable OWS as required by vessel SMS sections SOM-AD012.5.5.2 & SOM-TD005.4.3.6 Recommend ISM audit be conducted to the satisfactiono9f the Recognized Organization. SOLAS74am (04Ed) IX/3 ISM Part A 10
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 5 August 2009 — due date passed with no resolution recorded
Construction/Loadline › Structures › Superstructure
Issued 30 July 2009
Resolved
Two windows found shattered on board. Ensure windows are weather tight to the satisfaction of attending class surveyor. windows in question are cabin #10B & engineer's dressing room. ICLL 66 Reg. 18 Action: 70a
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 August 2009
Resolution: Recieved Class and [name withheld] stating repairs made.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 30 July 2009
Resolved
Two cement patches found on main deck aft of cargo hold #5. Repairs to be completed to the satisfaction of attending class surveyor. ICLL 66 Reg. 1 Action: 17a
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 August 2009
Resolution: Condition of Class issued. Permanent repairs to be completed at next port of call, but no later than 30SEP09.
Stability › Watertight Integrity › General
Issued 30 July 2009
Resolved
The shaft tube stern seal was found oil leaking into the engine room. Stern tube seal to be repaired to the satisfaction of attending class surveyor. SOLAS 74 amd. (2004 cons ed) Chapter I, Reg. 11 Action: 17a
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 August 2009
Resolution: Resolved by class report as follows: Maker''s instruction for stern tube seal allows total oil leakage of not more than 12 liters per day. C/E alleged only 0.5 liters leaking per day while underway. No leakage found at seal. Condition acceptable.
Fire Fighting › Nozzles › Number
Issued 2 February 2007
Resolved
Vessel is missing 02 fire hose nozzles and 01 fire hose in the engine room. Vessel must replace the missing fire hose nozzles and hose.
Action required: 705 - Other - as specified
Due 9 February 2007
Resolved 9 February 2007
Resolution: Received class report from BV satisfying requirement
Construction/Loadline › Structures › Door
Issued 2 February 2007
Resolved
Two of the Vessel's weather tight doors, located at the port side of the funnel deck leading to a fan room and on the second deck of the superstructure, cannot be closed properly and do not provide weather tight integrity. Vessel must repair both doors to the satisfaction of the attending classification society.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 12 February 2007
Resolved 9 February 2007
Resolution: Received class report from BV satisfying requirement.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 2 February 2007
Resolved
One off the ship's fire suits is torn and badly deteriorated. Vessel must replace the fire man's suit.
Action required: 705 - Other - as specified
Due 9 February 2007
Resolved 9 February 2007
Resolution: Received class report from BV satisfying requirement
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 2 February 2007
Resolved
During the PSCO's inspection of the oily water separator, the three way shut off valve did not go through its full range of motion. The Chief Engineer could not clarify if this operation was acceptable. The vessel must prove that the three way valve is operating correctly.
Action required: 705 - Other - as specified
Due 9 February 2007
Resolved 9 February 2007
Resolution: Received class report from BV satisfying requirement.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 2 February 2007
Resolved
The Vessel could not demonstrate audible and visual alarms on the bridge in event of a power failure to any one of the steering gear power units.
Action required: 17 - Rectify deficiencies prior to departure
Due 2 February 2007
Resolved 9 February 2007
Resolution: Received class report from BV satisfying requirement
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 2 February 2007
Resolved
The vessel could not demonstrate audible and visual alarms on the bridge in the event of a failure of electrical power supply to the control system.
Action required: 17 - Rectify deficiencies prior to departure
Due 2 February 2007
Resolved 9 February 2007
Resolution: Received class report from BV satisfying requirement
Electrical › Electric Generation Source (service) › Generator
Issued 2 February 2007
Resolved
The #1 and #3 SSDG's have numerous oil leaks coating the engine with oil.
Action required: 705 - Other - as specified
Due 9 February 2007
Resolved 9 February 2007
Resolution: Received class report from BV satisfying requirement
Documentation
Issued 14 May 2000
Resolved
OIL TRANSFER PROCEDURE, CONTENTS 33 U.S.C. 1321
Condition: Unknown
Due 28 December 2000
Resolved 28 December 2000
Accommodation/Occupational Safety
Issued 14 May 2000
Resolved
MARINE SANITATION DEVICE IS NOT PROPLERY LABELED
Condition: Unknown
Due 28 December 2000
Resolved 28 December 2000