← All vessels
FRIO KYKNOS
FRIO KYKNOS is a 1994 freight ship. The Coast Guard has recorded 24 inspections since 1994, most recently in July 2011, along with 15 deficiencies and 6 operational controls.
Records from 1994 to 2011. Most recent: operational control imposed, 4 July 2011.
- Built
- 1994
- Last inspected
- 4 July 2011
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 15 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9035072 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9HA3408
388152
Flag
LIBERIA
—
Maury page id
psix-388152
Inspections, by type
…with no type recorded18
Years with a record
12 calendar years (1994–2011)
The 24 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.
Documentation record
Tonnage as PSIX records it6082 - Convention (Subpart B), Gross Ton
4061 - Convention (Subpart B), Net Ton
7197 - Dead Weight, Ton
10946 - Displacement, Ton
4061 - Convention (Subpart B), Net Ton
7197 - Dead Weight, Ton
10946 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 24
4 July 2011
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4068603
23 December 2008
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3380165
16 December 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3380830
15 December 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3380191
12 December 2008
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3379168
11 December 2008
ISPS II Exam · Ballast Water Examination · Deficiency Check · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3376422
5 December 2008
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3375312
12 May 2004
Ballast Water Examination · Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2064514
7 July 2003
Security Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1838677
3 July 2003
Annual Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1834031
8 May 2002
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1614300
7 May 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 289662
9 May 2000
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 277563
26 January 2000
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 273914
25 June 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 416581
25 August 1997
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 407188
4 November 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 396998
15 July 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 674671
15 July 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 674673
15 July 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 719131
17 June 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 392550
26 December 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 386209
1 July 1994
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 368255
30 January 1994
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 364158
Deficiency record · 15
Engineering › Steering Gear System › Actuator
Issued 23 December 2008
Resolved
The vessel was granted a deviation to enter the Lower Mississippi River with a malfunctioning steering gear.
Engineering › Steering Gear System › Actuator
Issued 11 December 2008
Resolved
0936 - Steering Gear - While conducting operational test of steering gear, steering system would not respond while in remote operation on pump #2 in both hand and NFU modes. Local steering test satisfactory. Class to attest to proper operation of steering system prior to departure.
Lifesaving › Inflatable Liferafts › Not on Board
Issued 8 December 2008
Resolved
Vessel agent called to notify Sector Delaware Bay that the vessel lost an inflatable liferaft overboard during heavy weather on their transit to our port.
Engineering › Diesel Engine (auxiliary)
Issued 12 May 2004
Resolved
FOUND SOFT PATCH ON SALT WATER INLET PIPING FOR #2 SHIP SERVICE GENERATOR INTER COOLER.
Electrical › Electric Supply System (service)
Issued 12 May 2004
Resolved
EXPOSED WIRING PROTRUDING FROM REAR OF CONTROL PANEL IN ENGINE ROOM'S MAIN CONTROL. LEGACY COMPONENT DESC: Cable
Lifesaving › Lifeboat Equipment
Issued 8 May 2002
Resolved
PORT LIFEBOAT 3 RATIONS VACCUM SEAL UNSAT, STBD LIFEBOAT 6 RATIONS VACCUM SEAL UNSAT; 9 TOTAL RATIONS. VIOLATION OF SOLAS 74/78 CH.III REG.41/8.1.2 LEGACY COMPONENT DESC: Food Ration
Electrical
Issued 26 January 2000
Resolved
Prove proper operation of emergency generator automatic start utilizing #1 battery bank. (Auto start w/ battery bank #2 Sat.)
Lifesaving
Issued 26 January 2000
Resolved
Provide proper means to lower port lifeboat utilizing internal releasing wire.
Documentation
Issued 26 January 2000
Resolved
Provide updated qualification information for Oiler-Min Swe and Bosun-Tin Moe as current licenses have expired.
Documentation
Issued 17 June 1996
Resolved
PRIOR TO DEPARTURE, VESSEL MUST PROVIDE A DANGEROUS CARGO MANIFEST FOR THE AUTOMOBILES IT'S CARRYING AS CARGO.
Lifesaving
Issued 26 December 1995
Resolved
PRIOR TO DEPARTING PORT OF TAMPA, REPLACE BATTERIES OR OBTAIN WATER LIGHT IN RING BUOY, PORTSIDE LIFEBOAT DECK.
Lifesaving
Issued 26 December 1995
Resolved
PRIOR TO DEPARTING PORT OF TAMPA, INSTALL WEAK LINKS FOR BOTH PORT AND STBDLIFERAFTS. _x001C_
Fire Fighting
Issued 26 December 1995
Resolved
PRIOR TO DEPARTING PORT OF TAMPA, PROVIDE SPANNER WRENCHES AT EACH FIRE HOSE STATION.
Documentation
Issued 26 December 1995
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Deck/Cargo
Issued 26 December 1995
Resolved
PRIOR TO DEPARTING PORT OF TAMPA, REMOVE AND PROPERLY STOW PAINT CURRENTLYBEING STOWED IN AFT STEERING.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.