MAURY USCG vessel records Sign in
← All vessels

OURO DO BRASIL

OURO DO BRASIL is a 1993 freight ship. The Coast Guard has recorded 50 inspections since 1993, most recently in December 2025, along with 10 deficiencies and 5 operational controls, 1 with no removal date recorded.

Records from 1993 to 2025. Most recent: inspection, 3 December 2025.

Built
1993
Last inspected
3 December 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

9018646 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
388402
Flag
LIBERIA
—
Maury page id
psix-388402

Inspections, by type

…with no type recorded18
Years with a record 27 calendar years (1993–2025)
The 50 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.

Documentation record

Tonnage as PSIX records it26716 - Displacement, Ton
19519 - Dead Weight, Ton
15218 - Simplified, Gross Ton
15218 - Convention (Subpart B), Gross Ton
4566 - Convention (Subpart B), Net Ton
4566 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 50

3 December 2025 PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8271539
14 October 2022 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7577608
11 October 2022 PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7571253
8 December 2021 PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7357671
16 January 2021 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7123233
27 January 2020 PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6890588
20 August 2019 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6789249
27 June 2019 PII Safety Exam · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6727052
17 May 2019 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6686183
22 January 2019 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6613222
10 December 2018 ISPS II Exam · Deficiency Check · Ballast Water Examination · PII Safety Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6590961
28 September 2017 ISPS II Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6273553
24 July 2017 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6212582
20 July 2017 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6214842
9 January 2017 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6068317
11 October 2016 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6020340
7 May 2016 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5871153
20 January 2016 ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 5800201
5 October 2015 ISPS II Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5734771
6 October 2014 ISPS II Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4999785
19 August 2014 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4990357
15 May 2012 Administrative Inspection · Ballast Water Examination · ISPS III Exam · Random ISPS/MTSA/PSC · NPV Safety Exam · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4308269
25 July 2011 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4093833
25 January 2011 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3932468
15 January 2011 Administrative Inspection · Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3927077
21 March 2010 Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3699635
7 April 2009 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3447960
29 August 2008 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3312308
25 August 2008 ISPS I Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3308537
17 February 2008 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3148832
7 February 2008 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3143452
2 October 2007 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3070232
21 September 2007 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3062661
11 October 2006 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2797045
9 August 2005 Ballast Water Examination · ISPS III Exam · NPV Safety Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2457171
12 October 2004 MARPOL Annex I Examination · NPV Safety Exam · STCW 95 Exam · ILO-147 Exam · MARPOL Annex V Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2218753
9 September 2004 ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2191321
15 April 2004 Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2045240
14 April 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2044494
11 September 2002 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1674293
10 June 2002 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1628664
19 June 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 291130
21 April 2001 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 289388
14 April 2000 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 276539
27 December 1998 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 423971
21 February 1997 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 400707
16 February 1996 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 387929
10 April 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 365911
1 October 1993 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 361176
14 June 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 526845

Deficiency record · 10

07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 16 January 2021 Resolved
The machinery shall be installed to reduce to a minimum any dangers to persons onboard, due regard being paved to hot surfaces and other hazards. PSCO noticed the #2 lube oil purifier was leaking and being contained by a plastic container underneath flange connection.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 January 2021
Resolved 14 October 2022
Resolution: Class report recieved indicating deficiency was cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 10 December 2018 Resolved
05111 Before the ship leaves port and at all times during the voyage, all life saving appliances shall be in working order and ready for immediate use. PSCO observed liferaft hydrostatic release unit installed for EPIRB rather than the appropriate EPIRB hydrostatic release unit. 74SOLAS(2014) III/20.2
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 December 2018
Resolution: Received class report. New EPIRB hydrostatic release installed.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 10 December 2018 Resolved
07124 The function of the detection system shall be periodically tested to the satisfaction of the administration by means of equipment producing hot air at the appropriate temperature to which the detector is designed to respond. PSCO observed improper heating detector testing device on board for appropriate testing temperature of heat detectors. 74 SOLAS (1997) II-2/ 13.1.13
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 May 2019
Resolution: Witnessed satisfactory equipment.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 10 December 2018 Resolved
15108 the safety management system should include procedures ensuring that non conformities, accidents, and hazardous situations are reported to the company, investigated and analyzed with the objective of imposing safety and pollution prevention. PSCO observed no requisitions for required heat detector testing equipment that meets heat detector design temperature testing parameters. 74 SOLAS (2014) IX/3.1 ISM Code Part A 9.1
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 May 2019
Resolution: Witnessed satisfactory equipment.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Resources and personnel
Issued 10 December 2018 Resolved
15105 a vessel equipped with ballast water tank that operates in the waters of the United States must maintain a ballast water management plan that has been developed specifically for the vessel and that will allow those responsible for the plans implementation to understand and follow the vessel's ballast water management strategy and comply with the requirements of this subpart. Vessel's ballast water management plan does not include all of the necessary provisions listed in 33CFR151 subpart D. 33CFR151.2050(g)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 January 2019
Resolution: Vessel amended BWP to include use of thier approved BWTS under the newer version of 33CFR151.2050.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 15 May 2012 Resolved
0220 - Certificate of Competency - Port State Control officers shall be able to verify that all seafarers on board required to be certified hold appropriate certification. Master of vessel currently does not have his license of certification aboard vessel. -STCW (95) Reg. I/4.1.1. 17c
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 May 2012
Resolution: Rcv''''d a copy of the Master''''s current License from the Ship''''s company. Reviewed applicable information and compared to the Master''''s Endorsement for certification. All SAT. Advised Master of requirement to maintain original license/endorsement o
Lifesaving › Launching Appliances › Release Mechanism
Issued 15 January 2011 Resolved
0610 Each freefall lifeboat shall be fitted with a release system which shall be so arranged as to release the boat under any condition of loading from no load up to at least 200% of the normal load. Release system for the lifeboat is inoperable. SOLAS 74 (2009 Con. Ed) Chap. III Reg 34, LSA Code Chap. IV reg. 4.7.6.2. 17ac
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 January 2011
Resolution: The release mechanism for the lifeboat has been fixed and a class report was provided.
Lifesaving › Launching Appliances › Release Mechanism
Issued 15 January 2011 Resolved
0610 Before the ship leaves port and at all times during the voyage, all life saving appliances shall be in working order and ready for immediate use. For 10 days during vessels voyage, the freefall lifeboat was unsafe for use. SOLAS 74 (2009 Cons. Ed.) chap. III Reg 20.2 17ac
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 January 2011
Resolution: The lifeboat is now in working order. A class report was provided.
Navigation › Collision/Grounding Avoidance › Radar
Issued 17 February 2008 Resolved
3CM Radar found inoperable.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 17 February 2008
Resolved 29 August 2008
Resolution: Witnessed proper operation of the 3CM Radar, was also provided a copy of the class report asttesting to the proper operation of the 3CM Radar.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 11 October 2006 Resolved
9900 - Submit vessel response plan to U. S. Coast Guard for review. Obtain approval letter (or interim letter of approval) from U. S. Coast Guard Headquarters. Coast Guard and Marine Transportation Act of 2004. (50c)
Action required: 705 - Other - as specified
Due 11 November 2006
Resolved 13 October 2006
Resolution: Cleared deficiency based on guidance from G-PCV-1. Vesssel is provisionally in compliance.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.