Records from 1993 to 2005. Most recent: inspection, 10 February 2005.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Construction/Loadline
Issued 25 August 2003
No resolution recorded
HAIRLINE FRACTURES P/S FUEL TANKS WAY OF CHINE WELDMENT, MOST PROBABLE CAUSE METAL FATIGUE IN VIC OF HEAT AFFECTED ZONE OF WELDMENT. LEGACY COMPONENT DESC: Hull Plating
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 October 2003 — due date passed with no resolution recorded
Construction/Loadline › Hull
Issued 25 August 2003
Resolved
HULL INSERT FAILED AFT BUTT WELD. LACK OF SIDEWALL FUSION AND ROOT PENETRATION. LEGACY COMPONENT DESC: Hull Plating
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 August 2003
Resolved 25 August 2003
Resolution: CRK.
Stability
Issued 25 August 2003
No resolution recorded
Vessel is restricted from operating after 31Oct03 pending the results of a deadweight survey and stability letter for a particular route approved by the Marine Safety Center. Due date: 31Oct03.
Due 31 October 2003 — due date passed with no resolution recorded
Communications › Radio Communications
Issued 14 May 2003
Resolved
Provide a copy of the FCC Safety Certificate
Due 23 August 2003
Resolved 13 August 2003
Communications › Radio Communications
Issued 14 May 2003
Resolved
Provide a copy of the FCC Operator Permit
Due 23 August 2003
Resolved 13 August 2003
Communications › Radio Communications
Issued 14 May 2003
Resolved
The vessel is restricted to 20 NM from shore till proof of operation of the MF radio
Due 13 August 2003
Resolved 13 August 2003
Engineering › Bilge Water Management System
Issued 1 March 2002
Resolved
Provide overboard discharge valves in electric submersible bilge pumps. LEGACY COMPONENT DESC: Valve
Condition: Improper Installation
Due 10 March 2002
Resolved 4 March 2002
Accommodation/Occupational Safety › Ventilation
Issued 1 March 2002
Resolved
Provide plan for approval of engine room/F/O tank space ventilation. Upon approval install ventilation LEGACY COMPONENT DESC: Engine Room Ventilation
Condition: Improper Installation
Due 15 May 2002
Resolved 14 June 2002
Resolution: Ventilation was later located requiring no further action
Construction/Loadline › Structures
Issued 1 March 2002
Resolved
Provide plan for approval of adequate access to E/R. When approved, install same. LEGACY COMPONENT DESC: Machinery Space Opening
Condition: Improper Installation
Due 15 May 2002
Resolved 14 June 2002
Construction/Loadline › Markings
Issued 1 March 2002
Resolved
Provide label for max passengers on upper deck. LEGACY COMPONENT DESC: Max passengers
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 March 2002
Navigation › Piloting/Steering
Issued 1 March 2002
Resolved
Provide current Coast Pilot and Light list LEGACY COMPONENT DESC: Coast Guard Light List
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 March 2002
Resolved 5 March 2002
Lifesaving › Lifebuoys
Issued 1 March 2002
Resolved
Provide retro-reflective tape and 60 ft lifeline to lifering LEGACY COMPONENT DESC: Buoyant Lifeline
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 March 2002
Communications › Radio Communications
Issued 1 March 2002
Resolved
Provide documentation of registration with NOAA LEGACY COMPONENT DESC: EPIRB
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 March 2002
Communications › Internal Communications System
Issued 1 March 2002
Resolved
Provide additional PA system speaker LEGACY COMPONENT DESC: Public Address system
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 March 2002
Engineering › Fuel Oil Service System
Issued 1 March 2002
Resolved
Remove lock on bathroom doors to allow acess to emergency F/O shut-off valves, or provide exceptable alternative method for F/O shut-off requirement. LEGACY COMPONENT DESC: Valve
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 March 2002
Lifesaving › Lifejacket/PFD (Type I)
Issued 1 March 2002
Resolved
Properly mark location of PFD's LEGACY COMPONENT DESC: Marking
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 March 2002
Fire Fighting
Issued 1 March 2002
Resolved
Provide additional fire bucket LEGACY COMPONENT DESC: Fire bucket
Condition: Unknown
Due 18 March 2002
Resolved 14 March 2002
Stability › Watertight Integrity
Issued 1 March 2002
Resolved
Provide placards for watertight hatches and door LEGACY COMPONENT DESC: Watertight door/hatch placard
Condition: Improper/Lack of Maintenance
Due 18 March 2002
Resolved 14 March 2002
Stability › Watertight Integrity
Issued 1 March 2002
Resolved
Free all operating dogs on aft watertight door. LEGACY COMPONENT DESC: Securing dogs on hatches
Condition: Improper/Lack of Maintenance
Due 18 March 2002
Resolved 14 March 2002
Construction/Loadline › Markings
Issued 1 March 2002
Resolved
Provide loading mark as specified in 46 CFR 185.602 (d) LEGACY COMPONENT DESC: Draft Marks/Indicating System
Condition: Improper/Lack of Maintenance
Due 25 April 2002
Resolved 14 June 2002
Operations/Management › Drills/Instruction
Issued 1 March 2002
Resolved
Post emergency procedures LEGACY COMPONENT DESC: Emergency procedures
Due 18 March 2002
Resolved 14 March 2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 1 March 2002
Resolved
Main engines and ancillary equipment are deteriorated and could result in mechanical failure. Deterioration is due to fwd engine room acsess plate being left uncovered while underway. Engines will require considerable preparation and cleaning for determination of material condition. LEGACY COMPONENT DESC: Overall condition
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2002
Resolved 14 June 2002
Stability › Watertight Integrity
Issued 1 March 2002
Resolved
Sea valves were not internally inspected in Tampa during hull modifications, all other hull inspection items were checked. Valves will be inspected prior to June 10 2002 by MSO Miami personnel. LEGACY COMPONENT DESC: Main engine and generator sea valves
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 May 2002
Resolved 14 June 2002
Lifesaving
Issued 20 November 2001
Resolved
DEMONSTRATE UNDERWAY PASSENGER TRANSFER PROCEDURES IN THE PRESENCE OF A CG MARINE INSPECTOR PRIOR TO TRANSFERRING PASSENGERS AT SEA.
Condition: Unknown
Due 30 November 2001
Resolved 1 March 2002
Resolution: No longer applicable, vessel to operate in Miami.
Construction/Loadline
Issued 20 November 2001
Resolved
PROVIDE APPROVED PLANS FOR HULL MODIFICATIONS.
Condition: Unknown
Due 30 November 2001
Resolved 1 March 2002
Resolution: Approved plans for hull modifications observed by MSO Miami inspector.
Lifesaving
Issued 20 November 2001
Resolved
COMPLETE NEW-TO-ZONE INSPECTION FOR TAMPA PRIOR TO PLACING VESSEL IN SERVICE.
Condition: Unknown
Due 30 November 2001
Resolved 1 March 2002
Resolution: No longer applicable, vessel to operate in Miami.
Accommodation/Occupational Safety
Issued 6 June 2001
Resolved
Provide 4" rail courses, or an alternative acceptable to OCMI, as required by 46 CFR 177.900.
Condition: Unknown
Due 10 March 2002
Resolved 7 March 2002
Resolution: Netting has been installed on all deck periphery railings
Documentation
Issued 6 June 2001
Resolved
Provide current training logbook as required by 46 CFR 185.420.
Condition: Unknown
Due 6 July 2001
Resolved 1 March 2002
Documentation
Issued 6 June 2001
Resolved
Provide voyage plan in accordance with 46 CFR 185.503 prior to carrying passengers.
Condition: Unknown
Due 7 June 2001
Resolved 1 March 2002
Resolution: No longer applicable, vessel to operate in Miami with Limited Coastwise Route.
Documentation
Issued 6 June 2001
Resolved
Provide valid FCC Station License, FCC Safety Certificate and FCC Marine Radio Operator Permit as required by 46 CFR 80.
Condition: Unknown
Due 6 July 2001
Resolved 1 March 2002
Lifesaving
Issued 6 June 2001
Resolved
Provide proof of enrollment in drug and alcohol program in accordance with 46 CFR 15. Correct prior to carrying passengers.
Condition: Unknown
Due 7 June 2001
Resolved 1 March 2002
Documentation
Issued 6 June 2001
Resolved
Provide valid operator's license as required by 46 CFR 15. Correct prior to carrying passengers.
Condition: Unknown
Due 7 June 2001
Resolved 1 March 2002
Lifesaving
Issued 6 June 2001
Resolved
Provide passenger safety orientation as required by 46 CFR 185.506. Correct prior to carrying passengers.
Condition: Unknown
Due 7 June 2001
Resolved 1 March 2002
Documentation
Issued 6 June 2001
Resolved
Provide crew and passenger list as required by 46 CFR 185.502. Correct prior to carrying passengers.
Condition: Unknown
Due 7 June 2001
Resolved 1 March 2002
Lifesaving
Issued 6 June 2001
Resolved
Conduct fire drill and man overboard drill to satisfaction of Coast Guard inspector as required by 46 CFR 185.520. Correct prior to carrying passengers.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 March 2002
Construction/Loadline
Issued 6 June 2001
Resolved
Properly weld underside seams of bits forward of collision bulkhead, both sides.
Condition: Unknown
Due 1 April 2003
Resolved 8 March 2002
Construction/Loadline
Issued 6 June 2001
Resolved
Provide vessel's name on bow as required by 46 CFR 67.123.
Condition: Unknown
Due 6 July 2001
Resolved 4 March 2003
Accommodation/Occupational Safety
Issued 6 June 2001
Resolved
Provide 39.5" rails on all decks open to passengers as required by 46 CFR 177.900.
Condition: Unknown
Due 10 March 2002
Resolved 1 March 2002
Documentation
Issued 1 November 1995
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 1 December 1995
Resolved 29 November 1995
Navigation
Issued 1 November 1995
Resolved
PROVE PROPER OPERATION OF THE STERN NAVIGATION LIGHT.
Condition: Unknown
Due 1 December 1995
Resolved 6 December 1995
Engineering
Issued 1 November 1995
Resolved
PROVIDE AND INSTALL MACHINERY GUARDS OVER BOTH MAIN ENGINE TO JET PUMP DRIVE SHAFTS.
Condition: Unknown
Due 1 December 1995
Resolved 6 December 1995
Documentation
Issued 1 November 1995
Resolved
PROVIDE A "SENIOR DECK HAND LETTER" AND KEEP ON BOARD VESSEL.
Condition: Unknown
Due 1 December 1995
Resolved 6 December 1995
Documentation
Issued 1 November 1995
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 1 November 1995
Resolved 1 November 1995
Electrical
Issued 1 November 1995
Resolved
STENCIL SHORE-TIE/GENERATOR BREAKER SWITCH "CAUTION MORE THAN ONE SOURCE OFPOWER" IAW 46 CFR 183.10-10(C).
Condition: Unknown
Due 1 December 1995
Resolved 6 December 1995