← All vessels

CANYON EXPLORER

CANYON EXPLORER is a 1993 passenger vessel (inspected). The Coast Guard has recorded 55 inspections since 1993, most recently in June 2025, along with 57 deficiencies and 3 casualty investigations between 2006 and 2015.

Records from 1993 to 2025. Most recent: inspection, 23 June 2025.

Built
1993
Last inspected
23 June 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDQ4344
388722
Flag
UNITED STATES
368424660
Maury page id
psix-388722

Inspections, by type

…with no type recorded10
Years with a record 29 calendar years (1993–2025)
The 55 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)65.0 ft × 18.0 ft × 6.5 ft
Registered tonnagegross 50 / net 40
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDEFENDER YACHT CORPORATION · MIAMI, FL, UNITED STATES · built 1993
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portGULF SHORES, AL
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 18 June 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it50 - Simplified, Gross Ton
40 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ4344MMSI 368424660 · active · compulsorily equipped · granted 18 June 2025, expires 18 June 2035
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 55

23 June 2025 Simplified Stability Test · Initial Certification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8165629
11 June 2025 Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8057243
28 February 2023 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7649649
2 March 2022 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7411851
19 May 2021 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7201010
20 May 2020 Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6952805
15 October 2019 Damage Survey · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6836789
22 February 2019 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6630822
2 May 2018 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6400674
21 February 2018 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6359056
23 July 2017 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6220116
7 March 2017 Annual Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6100735
21 April 2016 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5859698
29 July 2015 Damage Survey · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5199733
28 July 2015 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5202278
21 May 2014 Annual Inspection · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4848476
23 January 2012 DAPI Audit · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4229966
27 October 2010 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3879105
2 June 2008 Drydock Exam · Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3219123
30 May 2007 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2946418
25 June 2006 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2696249
1 June 2006 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2667315
16 June 2005 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2377212
13 October 2004 Deficiency Check · Examination of Repairs · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2201322
16 June 2003 Hull Examination · Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1824850
30 September 2002 Damage Survey
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1682141
28 May 2002 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1626120
14 August 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 22847
24 July 2001 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1069138
24 July 2001 Examination of Repairs
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1070481
5 July 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 688
4 June 2001 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1362274
26 May 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 180651
18 July 2000 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1365891
22 June 2000 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 97296
26 August 1999 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 780597
13 July 1999 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1375851
16 June 1998 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1364786
16 June 1998 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1364787
6 June 1998 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 64085
19 November 1997 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1108541
8 September 1997 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 785539
10 April 1997 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1394736
4 June 1996 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 52253
17 April 1996 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 38795
5 March 1996 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1412955
8 March 1995 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1442235
21 February 1995 Plan Review "T" Boat
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 847879
5 August 1994 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 58108
8 March 1994 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 854432
19 October 1993 Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1152266
9 September 1993 Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1141438
9 September 1993 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1141922
8 July 1993 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1154197
23 June 1993 Plan Review "T" Boat · Initial Certification · Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1459024

Deficiency record · 57

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 July 2025 Resolved
Rail courses or the equivalent must be installed between a top rail required by paragraph (a) of this section, and the deck so that no open space exists that is more than 305 millimeters (12 inches) high except: On passenger decks of a ferry or of a vessel on an excursion trip the following must be installed: Bulwarks, chain link fencing or wire mesh that has openings of not more than 4 inches in diameter: bars slats, rail courses, or equivalent spaced intervals of not more than 4 inches. MI observed embarkation station with 3 chains spaced out beyond required dimensions. 46 CFR 177.900
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 August 2025
Resolved 30 July 2025
Resolution: Received photograph of installed gate back aft. Uploaded in documents. Cleared def.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 21 July 2025 Resolved
A hatch exposed to the weather must be watertight, except that the following hatches may be weathertight: A hatch in a cabin top. 46 CFR 179.360
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2025
Resolved 23 July 2025
Resolution: Operator sent pictures of weather tight stripping installed. all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 March 2022 Resolved
Deadend wire found in fuel tank space coming out of pressure switch for generator attached to fixed gas system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 April 2022
Resolved 12 April 2022
Resolution: Pictures sent...[name withheld]
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 2 March 2022 Resolved
Need to re-install P/A speakers on aft deck area (passenger area)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 April 2022
Resolved 12 April 2022
Resolution: Pictures sent...[name withheld]
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 20 May 2020 Resolved
All fire fighting equipment o/b vessel must be annually serviced in accordance with regulations. All fire fighting equipment o/b vessel had expired annual servicing tags. Must rectify to the satisfaction of the CG Marine Inspector prior to carrying passengers.
Action required: 705 - Other - as specified
Due 29 May 2020
Resolved 27 May 2020
Resolution: Email of servicing record sent to CG Sector SD.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 20 May 2020 Resolved
All gauges must be 100% operational on all vessel equipment. Gauge on fire pump was not functioning past 10 PSI. Must replace gauge to satisfaction of the CG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2020
Resolved 12 June 2020
Resolution: Def rectified through email, [name withheld]
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 May 2020 Resolved
Fire hose had leaks while operating fire pump. Must replace fire hose to satisfaction of the CG Marine Inspector.
Action required: 705 - Other - as specified
Due 3 June 2020
Resolved 1 July 2020
Resolution: Item is on order, anticipate arrival on 01JUL2020, [name withheld], Deficiency must be rectified prior to the carriage of passengers. Pictures sent in from operator..Def cleared
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 15 October 2019 Resolved
Repairs to the hull that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. Provide repair proposal for damage caused by allision with canyon wall.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2019
Resolved 16 February 2020
Resolution: Received pictures and statement from licensed Captain attesting to seaworthiness of vessel hull. Changed def to 30 days
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 15 October 2019 Resolved
Replace navigation light damaged from allision. (Prior to operating at night)
Action required: 705 - Other - as specified
Due 15 October 2019
Resolved 18 October 2019
Resolution: Picture of repaired nav light received.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 27 February 2019 Resolved
Found small crack located in the forpeak comparment on the starboard side at the sheer line. Properly make repairs to the satifaction to the attending marine inspector. (gouge out and re-weld)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 April 2019
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 27 February 2019 Resolved
Found port and starboard outboard longitudinal stringers de-laminated at eh bilge. Make proper repairs to original condition.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 March 2019
Resolved 15 April 2019
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 27 February 2019 Resolved
Found vertical cracks and seeping water intrusion on port and starboard outboard main bilge stringer. All damage was located forward of main engines support. Provide repair plan for USCG approval and make proper repairs to original condition.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2019
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 27 February 2019 Resolved
Provide simple instructions for fixed fire fighting system in the fuel tank room.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2019
Resolved 15 April 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 February 2019 Resolved
Renew or repair raw water pump on starboard main engine.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 April 2019
Resolved 15 April 2019
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 2 May 2018 Resolved
Provide new shaft packing for both port and starboard shafts.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2018
Resolved 1 June 2018
Resolution: Added packing to eliminate leak.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 2 May 2018 Resolved
Make bulkhead between engine room and lazerette watertight.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2018
Resolved 1 June 2018
Resolution: Bulkhead repaired. Now watertight.
Engineering › Sea-water System (primary cooling) › Piping
Issued 2 May 2018 Resolved
Repair leaking jacket water coolong pipes.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2018
Resolved 1 June 2018
Resolution: New heat exchanger plates installed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 15 March 2017 Resolved
Renew stern light lens cover. Current cover is very dirty and faded causing a very weak illumination/display of lamp.
Due 15 April 2017
Resolved 7 July 2017
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 21 April 2016 Resolved
Properly label overhead life jacket stowage in lower accommodation space.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 May 2016
Resolved 31 May 2016
Resolution: Life jacket overhead properly labeled.
Fire Fighting › Fire Pumps › Pressure
Issued 21 April 2016 Resolved
Install pressure gauge on fire pump and prove proper operation
Condition: Improper/Lack of Maintenance
Due 27 May 2016
Resolved 31 May 2016
Resolution: New fire pump gauge installed and tested.
Electrical › Electric Generation Source (service) › Panelboard
Issued 21 April 2016 Resolved
Install the required gauges for onboard generators greater than 50 volts; ammeter, hertz meter
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 May 2016
Resolved 31 May 2016
Resolution: The proper gauges were install and verified.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 21 April 2016 Resolved
Crop and renew rotted sections of the aft main deck to include decking, fiberglass and overhead beams.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 June 2016
Resolved 10 June 2016
Resolution: The aft deck was gutted and totally renewed with wood and FRP to original condition.
Electrical › Electrical Distribution System (service) › Cable
Issued 21 May 2014 Resolved
Remove all dead end wiring from vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 June 2014
Resolved 12 August 2014
Engineering › Steering Gear System › Hydraulic Hose
Issued 23 January 2012 Resolved
Replace 2 hydraulic steering hoses.
Due 12 April 2012
Resolved 11 May 2012
Resolution: Replace two steering hoses.
Stability › Watertight Integrity › General
Issued 23 January 2012 Resolved
Repair port rudder post base, the base is leaking water at full speed while turning.
Condition: Improper/Lack of Maintenance
Due 12 April 2012
Resolved 11 May 2012
Resolution: re-bedded rudder post base.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 2 June 2008 Resolved
Remove Pressure switch from the engine and install outside the engine room
Action required: 705 - Other - as specified
Resolved 21 July 2008
Resolution: 21 July 2008: Received email and pictures of Pressure switches being removed and install outside engine room.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 1 June 2006 Resolved
Hydro test 2 CO2 bottles for the engine room, bottles are expired.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 June 2006
Resolved 9 June 2006
Resolution: CO2 bottles have been tested and installed.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 16 June 2005 Resolved
Weld cracked rails on aft boarding areas.
Due 23 July 2005
Resolved 22 July 2005
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 16 June 2005 Resolved
Provide additional support on aft boarding area
Due 23 July 2005
Resolved 15 July 2005
Engineering › Steering Gear System › Interlock
Issued 16 June 2005 Resolved
Ensure on/off switches for port and starboard bridge wing controls in pilot house function properly.
Due 23 July 2005
Resolved 22 July 2005
Engineering › Steering Gear System › Rudder Stock
Issued 13 October 2004 Resolved
During U/W examination of steering system, observed major leakage of seawater into steering compartment (lazarette) in way of hull at both rudder stock support brackets. Visible movement of brackets noted. Required permanent repairs to hull & rudder stock support brackets be made.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 January 2005
Resolution: Both port & stbd rudder stock support brackets completely replaced. See file attached to Vessel Critical Profile for details, including photos. Underway test found repair satisfactory.
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 October 2004 Resolved
Install metal supports not more than 24 inched apart on cable & wiring in engine space, IAW 46 CFR 183.340(b)(4).
Action required: 705 - Other - as specified
Resolved 14 October 2004
Resolution: Metal supports installed as required.
Engineering › Shafting/Propeller Arrangements
Issued 30 September 2002 Resolved
Repair/replace broken shaft coupling on port shaft. LEGACY COMPONENT DESC: Coupling
Condition: Unknown
Due 4 October 2002
Resolved 4 October 2002
Engineering › Bilge Water Management System
Issued 28 May 2002 Resolved
Provide suction hose for portable hand pump long enough to reach deepest bilge and still pump water over the side. LEGACY COMPONENT DESC: Hose
Action required: 705 - Other - as specified
Due 15 June 2002
Resolved 4 June 2002
Navigation
Issued 24 July 2001 Resolved
Demonstrate proper operation of replacement steering gear arm.
Condition: Unknown
Due 31 October 2001
Resolved 15 November 2001
Construction/Loadline
Issued 4 June 2001 Resolved
Provide indicator of auto bilge pump operation by 07JUL01 to the satisfaction of the attending Marine Inspector.
Condition: Unknown
Due 4 June 2001
Resolved 4 June 2001
Navigation
Issued 18 July 2000 Resolved
Provide repair proposal for new rudders and install new rudders port and stbd.
Condition: Unknown
Due 18 July 2000
Resolved 18 July 2000
Navigation
Issued 18 July 2000 Resolved
Replace upper bearing stbd rudder.
Condition: Unknown
Due 18 July 2000
Resolved 18 July 2000
Electrical
Issued 18 July 2000 Resolved
Install proper fuses(200amp) in main diesel engine start circuit.
Condition: Unknown
Due 20 July 2000
Resolved 28 July 2000
Engineering
Issued 18 July 2000 Resolved
Remove rubber spacers and install proper size clamps for stbd pedro tube.
Condition: Unknown
Due 20 July 2000
Resolved 28 July 2000
Construction/Loadline
Issued 13 July 1999 Resolved
Install bilge alarm lights.
Condition: Unknown
Due 13 July 1999
Resolved 13 July 1999
Documentation
Issued 13 July 1999 Resolved
Post oil placard on bridge.
Condition: Unknown
Due 13 July 1999
Resolved 13 July 1999
Accommodation/Occupational Safety
Issued 13 July 1999 Resolved
Repair aft stb stern rail.
Condition: Unknown
Due 13 July 1999
Resolved 13 July 1999
Fire Fighting
Issued 13 July 1999 Resolved
Install stuffing tube on CO2 pressure switch.
Condition: Unknown
Due 13 July 1999
Resolved 13 July 1999
Electrical
Issued 13 July 1999 Resolved
Clean battery terminals.
Condition: Unknown
Due 13 July 1999
Resolved 13 July 1999
Fire Fighting
Issued 10 April 1997 Resolved
PROVIDE SERVICE REPORT FOR SERVICING OF FIXED CO2 SYSTEM._x001C_
Condition: Unknown
Due 1 May 1997
Resolved 1 May 1997
Fire Fighting
Issued 10 April 1997 Resolved
INSTALL PROPER OPERATING INSTRUCTIONS FOR FIXED CO2 SYSTEM._x001C_
Condition: Unknown
Due 1 May 1997
Resolved 1 May 1997
Fire Fighting
Issued 10 April 1997 Resolved
INSTALL SHUT DOWNS FOR BOTH MAIN ENGINES THAT SECURES ENGINES UPON DISCHARGE OF FIXED CO2 SYSTEM._x001C_
Condition: Unknown
Due 10 April 1997
Resolved 10 April 1997
Fire Fighting
Issued 9 September 1993 Resolved
SUBMIT REVISED PLAN FOR THE 150 LB FIXED CO2 FIRE EXTINGUISHING SYSTEM_x001C_ TO REFLECT SATISFACTORY SIZES OF CYLINDER VALVE AND DISCHARGE NOZZLES,_x001C_ AND DEAD END LINES CLOSED WITH CAP OR PLUG SHALL EXTEND AT LEAST 2 INCHES _x001C_BEYOND THE LAST ORIFICE.
Condition: Unknown
Due 9 September 1993
Resolved 9 September 1993
Engineering
Issued 8 July 1993 Resolved
INSTALL MACHINERY GUARD ON PORT MAIN PROPULSION ENGINE.
Condition: Unknown
Due 8 July 1993
Resolved 8 July 1993
Accommodation/Occupational Safety
Issued 23 June 1993 Resolved
INSTALL A SATISFACTORY VENTILATION FOR THE LAZARETTE AND COMPARTMENT _x001C_ FORWARD THE ENGINEROOM. VENTILATION FOR THE LAZARETTE MUST BE EQUIPPED_x001C_ WITH FLAME SCREENS (FUEL OIL TANKS IN THE LAZARETTE). _x001C_ _x001C_
Condition: Unknown
Due 23 June 1993
Resolved 23 June 1993
Fire Fighting
Issued 23 June 1993 Resolved
SUBMIT PLAN FOR THE FIXED CO2 SYSTEM FOR REVIEW AND APPROVAL. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 June 1993
Resolved 28 June 1993
Engineering
Issued 23 June 1993 Resolved
REPLACE PORT AND STARBOARD PROPULSION ENGINES' RPM INDICATORS IN THE _x001C_ PILOTHOUSE WITH INDICATORS SIMILAR TO THE ENGINEROOM. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 June 1993
Resolved 23 June 1993
Fire Fighting
Issued 23 June 1993 Resolved
PROVIDE A MEANS TO POSITIVELY SECURE PORT AND STARBOARD VENTILATION IN THE ENGINEROOM WHEN FIXED CO2 SYSTEM IS ACTIVATED. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 June 1993
Resolved 23 June 1993
Navigation
Issued 23 June 1993 Resolved
REPAIR INOPERABLE RUDDER ANGLE INDICATOR. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 June 1993
Resolved 23 June 1993
Navigation
Issued 23 June 1993 Resolved
PROVE PROPER OPERATION OF NAVIGATION LIGHTS FAILURE INDICATOR ALARM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 June 1993
Resolved 23 June 1993
Construction/Loadline
Issued 23 June 1993 Resolved
MAKE ALL PENETRATION THROUGH MAIN TRANSVERSE WATERTIGHT BULKHEAD BETWEEN _x001C_ ENGINEROOM AND LAZARETTE WATERTIGHT. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 June 1993
Resolved 23 June 1993

Casualty record · 3

25 June 2006Routine · role: Involved in a Marine Casualty · 1 injured · activity 2696249
16 June 2015Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 5155965
28 July 2015Routine · role: Involved in a Marine Casualty · activity 5202278
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.