MAURY USCG vessel records Sign in
← All vessels

STAR OF SAUGATUCK II

STAR OF SAUGATUCK II is a 2000 passenger vessel (inspected). The Coast Guard has recorded 35 inspections since 2000, most recently in July 2026, along with 25 deficiencies.

Records from 2000 to 2026. Most recent: inspection, 7 July 2026.

Built
2000
Last inspected
7 July 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDK7151
Flag
UNITED STATES
368081650
Maury page id
psix-3888

Inspections, by type

…with no type recorded1
Years with a record 23 calendar years (2000–2026)
The 35 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)64.0 ft × 20.0 ft × 6.0 ft
Registered tonnagegross 51 / net 41
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderQUEEN OF SAUGATUCK · SAUGATUCK, MI, UNITED STATES · built 2000
Hull materialSteel
PropulsionDiesel
Hull shapeShip
Hull configurationMonohull
Hailing portSAUGATUCK, MI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 11 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it51 - Simplified, Gross Ton
41 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDK7151MMSI 368081650 · active · compulsorily equipped · granted 15 March 2019, expires 15 March 2029 · licensed under a name not among this hull’s recorded names (not shown)
WDI7703MMSI 367107610 · cancelled · compulsorily equipped · granted 30 April 2016, cancelled 13 March 2019
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 35

7 July 2026 Administrative Inspection
Administrative · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 8431415
28 June 2026 Administrative Inspection · Damage Survey
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 8418292
21 May 2026 In-Service Inspection
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 8361429
13 April 2026 Annual Inspection
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 8325753
14 April 2025 COI Inspection
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 8106645
17 April 2024 Annual Inspection
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7891918
5 April 2023 Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7662332
2 November 2022 Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7586658
5 April 2022 Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7424150
27 April 2021 DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7183958
20 April 2020 DAPI Audit · COI Inspection
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 6941429
2 April 2019 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6656238
17 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6542376
1 May 2018 Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 6403849
16 November 2017 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 6313956
25 May 2017 Deficiency Check
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 6183279
1 May 2017 Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 6136404
2 May 2016 Annual Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 5863975
15 October 2014 Drydock Exam · Internal Structural Exam
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 5010186
7 December 2010 Administrative Inspection
Administrative · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 3905923
29 March 2010 COI Inspection
Physical examination · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 3704570
28 April 2009 Annual Inspection
Physical examination · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 3481878
3 October 2008 Administrative Inspection
Administrative · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 3338029
28 April 2008 Annual Inspection
Physical examination · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 3196053
8 May 2007 Annual Inspection
Physical examination · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2933157
25 April 2006 Annual Inspection
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2628924
9 May 2005 COI Inspection
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2341152
21 March 2005 Hull Examination
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2316429
27 December 2004 Drydock Extension
Administrative · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2266458
23 April 2004 Annual Inspection
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2052703
31 July 2003 Type not recorded
No type recorded · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2139023
29 April 2003 Re-Inspection
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 1797762
26 April 2002 Annual Inspection
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 1650798
27 April 2001 Re-Inspection
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 1465045
22 June 2000 Initial Construction-Excluding Oversight · Plan Review "T" Boat · Initial Certification
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1361580

Deficiency record · 25

02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 28 June 2026 Resolved
Vsl reported alliding with another vessel while mooring with passengers on board. Vessel is prohibited form sailing with passengers until the vessel is inspected by a USCG Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2026
Resolution: Vessel has no significant hull damage.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 April 2024 Resolved
Lifelines and floating waterlight secured around grablines of RLBs instead of the body of RLBs. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 17 April 2024
Resolution: Corrected on the spot
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 5 April 2023 Resolved
Fire pump was not operational. Repair kit for pump is on order.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 May 2023
Resolved 19 April 2023
Resolution: Verified pump operation.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 April 2022 Resolved
Observed flares/smoke container was in a clear container and not correctly marked "Distress Signals".
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2022
Resolved 7 April 2022
Resolution: Received photgraphic evidence of required container and markings.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 2 April 2019 Resolved
Distress signals (flares) expired.
Due 1 May 2019
Resolved 1 May 2019
Resolution: Renewed flares
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 17 September 2018 Resolved
Vsl is broadcasting: Call Sign from expired FCC License, incorrect Name, and greater/smaller than expected vessel length.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 March 2019
Resolved 2 April 2019
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 2 May 2017 Resolved
Light on lifebuoy not properly installed.
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 25 May 2017
Resolution: Light installed.
Communications › Internal Communications System › Sound-powered Telephone
Issued 1 May 2017 Resolved
Internal phone system not installed.
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 25 May 2017
Resolution: Phone system operable
Construction/Loadline › Structures › Transverse Bulkhead
Issued 15 October 2014 Resolved
Penetrations to accommodate wire in Bulkheads #2, & #5 are not watertight. Properly seal all bulkhead penetrations.
Due 31 October 2014
Resolved 30 April 2015
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 15 October 2014 Resolved
Flame screen for fuel oil vent pipe was painted and restricting air exchange as well as effectiveness of screen. Renew/replace flame screen w/30x30 mesh and/or end fitting with screen installed.
Due 31 October 2014
Resolved 30 April 2015
Resolution: Renewed entire end fitting with non return and flame screen.
Accommodation/Occupational Safety › Ventilation › General
Issued 15 October 2014 Resolved
No ventilation provided for Compartment #1 (anchor locker). Install ventilation in accordance 2ith 46 CFR 177.600(a)
Due 31 October 2014
Resolved 30 April 2015
Resolution: Gooseneck vent installed.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 28 April 2009 Resolved
Passenger count is limited to 144 adults until vessel provides 16 adult life jackets IAW 46 CFR 180.71.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 May 2009
Resolved 20 May 2009
Resolution: Verified vessel provided 16 missing adult life jackets.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 28 April 2009 Resolved
Properly mark all life jacket stowage lockers IAW 46 CFR 185. 604 (f).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 May 2009
Resolved 20 May 2009
Resolution: Verified the required 2" tall lettering and numbering where installed on all life jacket stowage locations.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 8 May 2007 Resolved
65 new lifejackets purchased by operator were not marked with vessel name per 46 CFR 185.604(b).
Action required: 705 - Other - as specified
Due 28 May 2007
Resolved 28 May 2007
Navigation › Collision/Grounding Avoidance › Radar
Issued 9 May 2005 Resolved
Radar was not available, it was being returned from maintenance.
Due 7 June 2005
Resolved 7 June 2005
Resolution: Radar repaired.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 9 May 2005 Resolved
5 GPM portable bilge pump was not on board.
Due 7 June 2005
Resolved 7 June 2005
Resolution: Owner bought a 5 GPM portable bilge pump for fwd hold.
Documentation › Markings/Placards › Garbage Placard
Issued 9 May 2005 Resolved
The Marpol V pollution Placard was not on board.
Due 7 June 2005
Resolved 7 June 2005
Construction/Loadline › Hull › Hull Plating
Issued 27 December 2004 Resolved
A drydock exam is required prior to carryng passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 March 2005
Resolution: Conducted DDE.
Fire Fighting
Issued 22 June 2000 Resolved
PROVIDE A SECOND MEANS OF POWERING THE VESSEL'S ELECTRIC FIRE PUMP. UNTIL COMPLETE, 4 ADDITIONAL TYPE B-II FIRE EXTINGUISHERS SHALL BE PROVIDED ON THE VESSEL.
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 September 2000
Resolved 1 October 2000
Documentation
Issued 22 June 2000 Resolved
OBTAIN A VALID FCC STATION LICENSE AND CONDUCT AN FCC-GREAT LAKES AGREEMENTINSPECTION.
Condition: Unknown
Due 22 June 2000
Resolved 22 June 2000
Electrical
Issued 22 June 2000 Resolved
PROVE PROPER OPERATION OF ALL GENERATOR GAUGES IN THE PILOT HOUSE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 June 2000
Resolved 22 June 2000
Electrical
Issued 22 June 2000 Resolved
DO NOT OPERATE AIR CONDITIONING SYSTEM UNTIL INSTALLATION IS COMPLETE AND INSPECTED BY A MARINE INSPECTOR. ADDITIONALLY, SECURE ALL CABLES FOR THE SYSTEM.
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 September 2000
Resolved 1 October 2000
Navigation
Issued 22 June 2000 Resolved
PROPERLY REPAIR MAGNETIC COMPASS AND PROVE OPERATION, INCLUDING LIGHT. VESSEL LIMITED TO DAYLIGHT OPERATIONS ONLY AND RIVERS ROUTE UNTIL COMPLETE.
Condition: Unknown
Due 22 June 2000
Resolved 22 June 2000
Construction/Loadline
Issued 22 June 2000 Resolved
PROPERLY LABEL BILGE HIGH LEVEL ALARMS (LIGHTS) AT THE BRIDGE INDICATOR PANEL.
Condition: Unknown
Due 22 June 2000
Resolved 22 June 2000
Engineering
Issued 22 June 2000 Resolved
PERMENANTLY LABEL THE FUEL OIL SHUT OFF VALVES.
Condition: Unknown
Due 22 June 2000
Resolved 22 June 2000

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.