GAMMAGAS is a 1992 tank ship. The Coast Guard has recorded 22 inspections since 1993, most recently in September 2016, along with 16 deficiencies.

Records from 1993 to 2016. Most recent: inspection, 18 September 2016.

Built
1992
Last inspected
18 September 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9005493 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
388953
Flag
ANTIGUA AND BARBUDA
—
Maury page id
psix-388953

Inspections, by type

…with no type recorded13
Years with a record 10 calendar years (1993–2016)
The 22 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it6914 - Displacement, Ton
4447 - Dead Weight, Ton
3703 - Convention (Subpart B), Gross Ton
1144 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 22

18 September 2016 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6003590
12 December 2015 COC-GAS Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 5779320
17 March 2009 COC-GAS Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3435136
1 May 2007 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2919867
8 February 2007 COC-GAS Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2862898
7 February 2007 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2872761
24 January 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 424860
24 January 1999 Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1123272
26 February 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 400979
26 February 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1102672
24 June 1996 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 392521
17 December 1995 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 513281
5 September 1995 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 382308
5 September 1995 Letter of Compliance (Initial/Renewal)
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 883859
16 May 1995 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 378429
15 December 1994 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1148742
6 October 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 862023
9 September 1994 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 499998
11 March 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 479965
29 December 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1160605
3 September 1993 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 360742
3 September 1993 Certificate of Compliance
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1139764

Deficiency record · 16

Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 12 December 2015 Resolved
1099-Alarms & signals- Each cargo tank shall be fitted with a high level (overfill) alarm that shall automatically actuate shutoff and prevent the tank from becoming liquid full. PSCOs observed the high level alarm fail to actuate an emergency shut-down.-IGC 1983 5.6
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 December 2015
Resolved 15 December 2015
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Combustible Gas Indicator
Issued 12 December 2015 Resolved
0715-Detection-Gas detection equipment should be so designed that it may readily be tested. Testing and calibration should be carried out at a regular interval. At time of examination, PSCOs observed inability of the vessels crew to execute testing and calibration in accordance with the vessel's gas detection instructions.- IGC 1983 13.6.6
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 December 2015
Resolved 15 December 2015
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Combustible Gas Indicator
Issued 12 December 2015 Resolved
0715-Dectection-The gas detection equipment should be capable of sampling and analysing from each sample head location. PSCOs observed the #6 and #7 sampling locations to be inoperative. - IGC 1983 13.6.7
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 December 2015
Resolved 15 December 2015
Fire Fighting › Water Fog Applicators › Condition
Issued 12 December 2015 Resolved
0799-Other(firefighting equipment)- A water-spray system for cooling, fire prevention & crew protection should be installed on ships carrying flammable or toxic products or both. During operations test, PSCOs observed at least 6 plugged nozzles including multiple nozzles at each tank dome, compressor area, & superstructure causing inadequate coverage of those areas for firefighting. IGC 1983 11.3
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 December 2015
Resolved 15 December 2015
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Relief Valve
Issued 12 December 2015 Resolved
1138-Liquified gases in bulk-The changing of the set pressure should be carried out under the supervision of the master IAW the procedures approved by Administration & specified in the ships operating manual. PSCOs observed the MARVS (maximum allowable relief valve setting) still in place for the IMO setting, as opposed to the USCG approved in port MARVS settings. -IGC 1983 8.2.7
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 December 2015
Resolved 15 December 2015
Deck/Cargo › Cargo Stowage › General
Issued 12 December 2015 Resolved
1138-Liquified gases in bulk- The condition of the ship & its equipment should be maintained to conform with the provisions of the Code to ensure that the ship will remain fit to proceed to w/o danger to the ship, persons on board, or marine environment. PSCOs observed an unauthorized modification to the cargo condensor on deck, which compromised the overall integrity of the unit. IGC 1983 1.5.3
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 December 2015
Resolved 15 December 2015
Accommodation/Occupational Safety › Ventilation › General
Issued 12 December 2015 Resolved
0999-Safety-Ventilation systems of cargo shall be in compliance with the provisions of Reg 16, which states power ventilation of service, cargo, control & machinery spaces shall be capable of being stopped from an easily accessible position outside the space being served. PSCOs found no operational control for the ventilation to the bosun store from outside the space. SOLAS 74 (1997 Cons)II-2/48
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 20 December 2015
Resolved 15 December 2015
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 12 December 2015 Resolved
2560-Company verification, review & evaluate- Significant evidence was discovered during an expanded machinery and cargo exam revealing the company/vessel failed to implement all applicable requirements of the SMS by not verifying appropriate corrective action was taken. Recommend an external audit of the vessels SMS.-74 SOLAS(09 Cons) IX/3.1 & ISM Code Reg 5, Part A Reg 1.4, 2.2,3,5,9, & 10
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 December 2015
Resolved 15 December 2015
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Combustible Gas Indicator
Issued 17 March 2009 Resolved
1899 - The vessel's fixed gas detection sample point# 6 is not operable. The sample point did not detect the span gas that was introduced. - Gas Carrier Code 1983
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 April 2009
Resolution: Received class report. Fixed gas detection system sample point no.6 repaired.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Manifold
Issued 17 March 2009 Resolved
1899 - The vessel starboard manifold liquid line is not operating properly. The #2 liquid line does not close within 30 seconds. - Gas Carrier Code 1983 Ch. 5-3-4(6)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 April 2009
Resolution: Received class report. Closing time of SB manifold #2 liquid line found within 30 sec.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 17 March 2009 Resolved
2550 - The vessel is not following the required instruction as per the safety management system to follow manufacturer’s instructions for calibration of the system for start up after installation. - ISM Code REG. 3-1
Action required: 705 - Other - as specified
Due 17 March 2009
Resolved 17 March 2009
Resolution: Rectified on scene.
Deck/Cargo
Issued 5 September 1995 Resolved
Provide mechanical means for securing the containment drain around each vent pipe. Must NOT be in the form of "DC" or conical plugs of any material.
Condition: Unknown
Due 18 December 1995
Resolved 18 December 1995
Lifesaving
Issued 6 October 1994 Resolved
NEXT U.S. VOYAGE, PROFESSIONALLY SERVICE ALL SCBA's AND PROVIDE SERVICE REPORT TO COGNIZANT OCMI.
Condition: Unknown
Due 6 October 1994
Resolved 6 October 1994
Lifesaving
Issued 6 October 1994 Resolved
NEXT U.S. VOYAGE, PROPERLY STENCIL HIGH LEVEL ALARM AND OVERFLOW ALARM ON THE OPEN DECK IN ACCORDANCE WITH 46 CFR 153.408(d) AND 46 CFR 153.409(d).
Condition: Unknown
Due 6 October 1994
Resolved 6 October 1994
Engineering
Issued 6 October 1994 Resolved
NEXT U.S. VOYAGE, DEMONSTRATE PROPER OPERATION OF AUDIBLE ALARM FOR LOSS OFPOWER AND LOW HYDRAULIC OIL FOR STEERING GEAR SYSTEM ON THE BRIDGE TO COGNIZANT OCMI.
Condition: Unknown
Due 6 October 1994
Resolved 6 October 1994
Fire Fighting
Issued 6 October 1994 Resolved
NEXT U.S. VOYAGE, PROVIDE CLASS REPORT TO THE SUITABILITY OF THE FIREFIGHTING SYSTEM IN THE PAINT LOCKER TO COGNIXANT OCMI.
Condition: Unknown
Due 6 October 1994
Resolved 6 October 1994