BLUE

BLUE is a 1982 passenger vessel (inspected). The Coast Guard has recorded 11 inspections since 2020, most recently in May 2025, along with 13 deficiencies and 1 operational control.

Records from 2020 to 2025. Most recent: inspection, 13 May 2025.

Built
1982
Last inspected
13 May 2025
Documentation
Case Pending · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 13 May 2025
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2020–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

389056
Flag
UNITED STATES
Maury page id
psix-389056

Documentation record

Registered dimensions (L × B × D)40.0 ft × 12.0 ft × 5.0 ft
Registered tonnagegross 12 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBILL LEE YACHTS INC · SOQUEL, CA, UNITED STATES · built 1982
Hull materialFRP (Fiberglass)
PropulsionAuxiliary Sail
Hull shapeSail (Distinct Keel)
Hull configurationMonohull
Hailing portSOUTH LAKE TAHOE, CA
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationCase Pending · issued 4 August 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it10 - Simplified, Net Ton
12 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 11

13 May 2025 COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8129073
7 March 2025 Internal Structural Exam · Deficiency Check · Drydock Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8093113
5 March 2024 Plan Review "T" Boat · Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7874672
9 May 2023 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7684768
29 June 2022 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7490967
3 May 2022 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7445617
28 April 2021 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7180254
15 June 2020 COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6977379
11 June 2020 Simplified Stability Test
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6974433
28 April 2020 Administrative Inspection · Initial Certification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6945022
14 April 2020 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6986950

Deficiency record · 13

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 May 2025 Resolved
Each... ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. Vessel's ring life buoys did nothave retroreflective tape. 46 CFR 185.604 (i)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2025
Resolved 10 June 2025
Resolution: Operator installed retroreflective tape.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 May 2025 Resolved
A vessel must carry either a first aid kit that meets the requirements in 46 CFR 199.175 (b)(10) of a kit with equivalent contents and instructions. Vessel's first aid kit is expired. 46 CFR 184.710
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2025
Resolved 10 June 2025
Resolution: Operator replaced first aid kit.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 May 2025 Resolved
A power driven vessel underway shall exhibit a masthead light forward, sidelights, and a stern light. Vessel's port and stbd running lights are extinguished. 33 CFR 83.23(a)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2025
Resolved 10 June 2025
Resolution: Operator replaced running lights.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 May 2025 Resolved
In addition, the owner shall, prior to receiving a certificate of inspection, submit for approval to the cognizant OCMI, at least two copies of the following plans... on sailing vessels: rigging plan showing sail areas and centers of effort as well as the arrangement, dimensions, and connnections of the standing rigging. Provide rigging plan, including rigging inventory list, to the satisfaction of the MI. 46 CFR 177.202(b)(12)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2025
Resolved 13 June 2025
Resolution: MI received satisfactory rigging plan and inventory list.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 March 2025 Resolved
The piping must be properly supported by noncombustible hangers or blocks. Vessel's mounted muffler for the wet exhaust was found parting from it's mounted area. Repair to the satisfaction of the MI. 46 CFR 182.430(b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2025
Resolved 13 May 2025
Resolution: MI attended vessel to verify repairs.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 5 March 2024 Resolved
Machnery spaces must be sperated from accomadation spaces by boundarires that prevent the passage of vapors. The engine compartment has 02 locations that are not vaportight. 46CFR177.405(c)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2024
Resolved 30 April 2024
Resolution: Sent satisfactory pictures of completed vapor tight repairs.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 March 2024 Resolved
A power driven vessel underway shall: Exhibit a masthead light forward. Vessel's bow light is extinguished. 33CFR83.23(a)(i)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2024
Resolved 30 April 2024
Resolution: Submitted satisfactory picture of new installed light.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 5 March 2024 Resolved
A vessel must carry a first aid kit that meets the requirements in 46CFR199.175(b)(10) or a kit with equiavalent contents. Vessl had expired contents in medical kit that needs to be replaced. 46CFR184.710
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2024
Resolved 30 April 2024
Resolution: Received satisfactory picture of newly purchased Medical Kit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 May 2023 Resolved
A visual and audible alarm must be provided at teh operating station to indicate a high water level in an unusually unmanned space. Bilge high level alarm found to be inoperable. 46CFR182.520
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2023
Resolved 24 May 2023
Resolution: Operator repaired bilge high level alarm with new unit.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 3 May 2022 Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment. Fixed and portable fire extinguishers have expired annual servicing.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 4 May 2022
Resolution: Vessel had equipment inspected by third party.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 29 April 2021 Resolved
"The Certificate of Inspection must be posted under glass or other suitable transparent material, such that all pages are visible." 46 CFR 176.302 Post COI, COD, and stability letter.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2021
Resolved 13 May 2021
Resolution: Provided photo evidence of posted documentation on board.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 29 April 2021 Resolved
"Containers shall be clearly marked in legible contrasting letters at least 0.5 inches high: DISTRESS SIGNALS." 46 cfr 185.614
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2021
Resolved 4 May 2021
Resolution: Proivded proof of "DISTRESS SIGNALS" labeling.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 29 April 2021 Resolved
"A vessel must carry either a first aid kit approved under series 160.041 or a kit with equivalent contents." 46 CFR 184.710 Missing Asprin and Ammonia inhalants.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2021
Resolved 7 May 2021
Resolution: Provided proof of ammonia inhalants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.