MAURY USCG vessel records
← All vessels

HOLLIWOOD ONE

Built
1993
Last inspected
14 December 2022
Controls
None recorded without a removal date
Also recorded as
CASINO QUEEN (2005–2006)

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.

Inspection record

Last inspected 14 December 2022
…with no type recorded120
Operational controls None recorded without a removal date
Years with a record 17 calendar years (1993–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WBU4632
389084
Flag
UNITED STATES
Tonnage
3417 - Regulatory (Subpart C or D), Net Ton 3417 - Regulatory (Subpart C or D), Gross Ton
Maury page id
psix-389084
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. Only barges and towing vessels are in this archive, so any other vessel type in the same activity does not appear here: these lists are a floor, not a complete manifest.

FANCY JAYNE Towing Vessel · MISLE 389083 · 26 May 1994 · activity 26297FANCY JAYNE Towing Vessel · MISLE 389083 · 23 October 1993 · activity 3767FANCY JAYNE Towing Vessel · MISLE 389083 · 10 October 1993 · activity 153293

Inspection history · 265

14 December 2022 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7609076
27 October 2008 Uninspected Other
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3356428
25 April 2008 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3192247
11 October 2007 Re-Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3076854
23 July 2007 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3004930
10 July 2007 Re-Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2970229
30 April 2007 Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2919426
24 April 2007 In-Service Inspection · Administrative Inspection · Deficiency Check · COI Inspection · MTSA Verification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2900908
1 February 2007 Administrative Inspection · Periodic Inspection · In-Service Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2852230
30 November 2006 In-Service Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2830828
31 October 2006 In-Service Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2797769
10 July 2006 Deficiency Check · Internal Structural Exam · Hull Examination · Re-Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2658974
10 July 2006 Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2731838
1 June 2006 Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2666439
19 April 2006 Deficiency Check · COI Inspection · MTSA Verification
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2628525
18 April 2006 In-Service Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2627509
11 April 2006 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2630591
8 March 2006 In-Service Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2598886
24 February 2006 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2649675
21 January 2006 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2570572
18 January 2006 Periodic Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2560076
8 November 2005 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2528589
24 October 2005 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2521501
17 October 2005 Periodic Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2508444
9 October 2005 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2510986
6 October 2005 Examination of Repairs · Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2508967
7 September 2005 Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2487543
10 August 2005 Deficiency Check · Deadweight Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2407829
22 July 2005 In-Service Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2407823
7 July 2005 Internal Structural Exam · In-Service Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2406476
7 July 2005 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2460868
3 July 2005 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2460840
10 May 2005 Deficiency Check · MTSA Verification
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2345799
28 April 2005 COI Inspection · In-Service Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2327509
9 March 2005 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2302340
1 February 2005 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2286244
25 January 2005 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2280701
4 January 2005 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2279159
15 November 2004 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2241149
29 October 2004 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2254300
4 October 2004 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2212743
22 August 2004 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2198033
17 August 2004 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2169064
27 July 2004 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2146397
11 May 2004 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2063963
1 May 2004 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2057169
20 April 2004 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2038299
12 April 2004 Annual Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2042790
6 April 2004 Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2038542
11 February 2004 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2004444
22 January 2004 Quarterly Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1958105
23 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1979829
2 December 2003 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1957249
21 November 2003 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1950680
22 October 2003 Quarterly Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1911822
4 September 2003 Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1896779
22 August 2003 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1881162
29 July 2003 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1860643
25 July 2003 Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1854672
24 July 2003 Quarterly Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1838517
16 May 2003 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1794972
25 April 2003 Underwater Inspection in lieu of Drydock
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1780452
24 April 2003 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1770417
8 April 2003 Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1770436
28 February 2003 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1750236
20 February 2003 Deadweight Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1749348
3 February 2003 Quarterly Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1730038
27 November 2002 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1710356
11 November 2002 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1739113
1 November 2002 Quarterly Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1697758
29 October 2002 Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1697836
27 October 2002 Security Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1701842
23 August 2002 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1665491
23 August 2002 Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1665511
31 July 2002 Quarterly Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1645279
28 June 2002 Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1638438
16 June 2002 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1631544
17 May 2002 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1617602
10 May 2002 Drydock Extension
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1608643
1 May 2002 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1604915
18 April 2002 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1610397
8 April 2002 Administrative Inspection · Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1604786
26 February 2002 Examination of Repairs · Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1488271
14 February 2002 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1490120
25 January 2002 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1479859
4 December 2001 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 772838
27 November 2001 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 772079
7 November 2001 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1458951
10 October 2001 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1476380
19 September 2001 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1075281
10 September 2001 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1074935
27 August 2001 Deficiency Check · Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1432556
19 August 2001 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1070465
12 June 2001 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1362442
2 May 2001 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1366364
27 March 2001 Deadweight Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1064476
26 March 2001 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1061303
8 March 2001 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1060121
1 February 2001 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1437847
27 December 2000 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1056687
14 December 2000 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1055969
5 December 2000 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1055855
27 November 2000 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 825270
9 November 2000 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 823959
24 October 2000 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 823073
24 October 2000 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1457842
18 September 2000 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 56135
31 August 2000 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 693532
3 August 2000 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1464310
18 July 2000 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 822603
23 June 2000 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 819309
17 May 2000 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1470270
2 May 2000 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1457805
28 March 2000 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1047342
9 February 2000 Deficiency Check · Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1393352
14 December 1999 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 812612
19 November 1999 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 158260
9 November 1999 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1451469
10 September 1999 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 784469
10 August 1999 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1444213
6 August 1999 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1397261
18 May 1999 Examination of Repairs
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1446783
10 May 1999 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1388833
18 March 1999 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 93606
12 March 1999 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 805403
16 February 1999 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1473573
15 December 1998 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 808464
12 December 1998 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 47999
11 December 1998 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 31188
4 November 1998 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1441432
12 October 1998 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 172585
5 October 1998 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 801655
18 September 1998 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1419883
3 September 1998 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1461070
31 August 1998 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1400852
22 June 1998 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 791752
14 May 1998 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 22787
13 May 1998 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 792360
6 May 1998 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 17275
26 April 1998 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 180
27 March 1998 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 787694
26 February 1998 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1398858
20 February 1998 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 37903
7 February 1998 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 66770
7 February 1998 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 138707
1 February 1998 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 773859
26 January 1998 Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1118152
22 December 1997 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 45608
3 December 1997 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1394872
5 October 1997 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2638
26 September 1997 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 784896
25 August 1997 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1406173
29 July 1997 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 784135
10 July 1997 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 50203
25 May 1997 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1380891
9 May 1997 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1102087
31 March 1997 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1099541
27 February 1997 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1406057
17 February 1997 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 139255
23 January 1997 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1102227
16 January 1997 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1099332
18 December 1996 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1461756
7 November 1996 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 159469
11 October 1996 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 841386
28 August 1996 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1405961
28 June 1996 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1245586
25 May 1996 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1417963
11 April 1996 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 111989
17 March 1996 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 66372
14 March 1996 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 885477
29 February 1996 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1396456
27 February 1996 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 29432
16 January 1996 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 100512
16 January 1996 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1184223
28 November 1995 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 136418
27 November 1995 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1425657
20 October 1995 Examination of Repairs
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1182714
28 August 1995 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1405787
25 August 1995 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 65980
11 August 1995 Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1182435
9 August 1995 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 128027
8 August 1995 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 66687
22 June 1995 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1190906
20 June 1995 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 878308
13 June 1995 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 84169
25 May 1995 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 872553
8 April 1995 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 88841
23 March 1995 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1135397
21 March 1995 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 118299
21 March 1995 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 123783
13 March 1995 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 827131
13 March 1995 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1173924
9 March 1995 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 7982
3 March 1995 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1166928
7 February 1995 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 88052
6 February 1995 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 84899
3 February 1995 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 107292
2 February 1995 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 179895
1 February 1995 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 77304
18 January 1995 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 865578
11 January 1995 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 77288
11 January 1995 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 98234
9 January 1995 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 118916
6 December 1994 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1162982
30 November 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 128235
12 November 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 64664
12 October 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 870711
11 October 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 64155
6 October 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 693537
25 September 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 98953
21 September 1994 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1180960
21 September 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1389899
16 September 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 3576
2 September 1994 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1172653
20 August 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 153684
27 June 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 89299
19 June 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 21699
19 June 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 28932
19 June 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 34277
10 June 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 182667
9 June 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 164858
8 June 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 367801
5 June 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 64473
2 June 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 101305
31 May 1994 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1170809
29 May 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 46666
26 May 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 26297
26 May 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 143223
23 May 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 99441
13 May 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 66840
13 May 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 93052
11 May 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 50448
9 May 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 79594
9 May 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 125386
7 May 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 169086
5 May 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 145807
4 May 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 88585
4 May 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 159809
1 May 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 168184
29 April 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 42134
28 April 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 143596
28 April 1994 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1168995
24 April 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 4404
22 April 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 90737
21 April 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 107342
21 April 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 161566
20 April 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 108893
20 April 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 224100
29 March 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 857950
16 March 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 96941
16 March 1994 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1165754
4 March 1994 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 853153
13 January 1994 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1161090
11 January 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1432760
28 October 1993 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 109300
23 October 1993 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 3767
10 October 1993 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 119993
10 October 1993 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 153293
1 October 1993 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1157649
27 September 1993 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1157472
8 September 1993 Deficiency Check · Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1153835
23 June 1993 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 845189
4 June 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 128632
2 June 1993 Initial Certification · Initial Construction-Excluding Oversight · Deadweight Survey
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1149420
19 May 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 13321

Deficiency record · 480

Electrical › Lighting (emergency) › Lighting Fixture
Issued 11 October 2007 Resolved
Prove proper operation and install protective covers for all exterior emergency lights.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 November 2007
Resolved 14 December 2022
Resolution: After pulling an open deficiency report for SUMR from MISLE, noted the vessel had 5 open defs from 11NOV2007. Research determined the Vessel was removed from passenger service. All discrepnacies were closed.
Electrical › Lighting (service) › Lighting Fixture
Issued 11 October 2007 Resolved
Properly repair WTD #9 red entry light in void #8.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 November 2007
Resolved 14 December 2022
Resolution: After pulling an open deficiency report for SUMR from MISLE, noted the vessel had 5 open defs from 11NOV2007. Research determined the Vessel was removed from passenger service. All discrepnacies were closed.
Fire Fighting › Grease Extraction Hood › General
Issued 11 October 2007 Resolved
Properly install instruction sign for the galley deep fat fryer fire suppression system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 November 2007
Resolved 14 December 2022
Resolution: After pulling an open deficiency report for SUMR from MISLE, noted the vessel had 5 open defs from 11NOV2007. Research determined the Vessel was removed from passenger service. All discrepnacies were closed.
Personnel › Training › Fire Fighting Basic
Issued 11 October 2007 Resolved
Prior to carrying passengers must conduct man overboard and fire drills.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 November 2007
Resolved 14 December 2022
Resolution: After pulling an open deficiency report for SUMR from MISLE, noted the vessel had 5 open defs from 11NOV2007. Research determined the Vessel was removed from passenger service. All discrepnacies were closed.
Communications › Visual Communication › Warning Sign (gangway)
Issued 11 October 2007 Resolved
Properly post a sign stating which doors are being used for emergency evacuation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 October 2007
Resolved 14 December 2022
Resolution: After pulling an open deficiency report for SUMR from MISLE, noted the vessel had 5 open defs from 11NOV2007. Research determined the Vessel was removed from passenger service. All discrepnacies were closed.
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 11 October 2007 Resolved
Prove proper operation of all emergency safeties on all machinery prior to carrying passenegers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 November 2007
Resolved 14 December 2022
Resolution: After pulling an open deficiency report for SUMR from MISLE, noted the vessel had 5 open defs from 11NOV2007. Research determined the Vessel was removed from passenger service. All discrepnacies were closed.
Electrical › Lighting (service) › Lighting Fixture
Issued 10 July 2007 Resolved
Install light fixture protection on exterior lights IWA of the fwd port stbd side on the first deck.
Due 10 July 2007
Resolved 10 July 2007
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 10 July 2007 Resolved
Prove proper operation of smike detector in the void #2 void space.
Due 10 July 2007
Resolved 10 July 2007
Deck/Cargo › Mooring/Anchoring › Winch
Issued 10 July 2007 Resolved
Prove proper operation of the port stern winch on the power module.
Due 10 July 2007
Resolved 10 July 2007
Fire Fighting › Fire Hoses › Condition
Issued 10 July 2007 Resolved
Worn hose at EMS fire station.
Action required: 705 - Other - as specified
Resolved 10 July 2007
Resolution: Replaced with new hose.
Navigation › Collision/Grounding Avoidance › Searchlight
Issued 10 July 2007 Resolved
Starboard search light unable to move up and down. Side to side movement very slow.
Action required: 705 - Other - as specified
Resolved 10 July 2007
Resolution: Corrected and made operational.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 10 July 2007 Resolved
Two stern lights inoperable.
Action required: 705 - Other - as specified
Resolved 10 July 2007
Resolution: New bulbs installed, navigation lights were operational.
Engineering › Thrusters › Motor
Issued 24 April 2007 Resolved
Repair Hi-Temp alarm sending unit on vessels' stern thruster.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 8 May 2007
Resolved 30 May 2007
Resolution: Witnessed installation of new sending unit. Item color coded white.
Engineering › Compressed Air System (control) › Valve
Issued 24 April 2007 Resolved
Pressure test and set relief vales on all three pressure vessels.
Action required: 705 - Other - as specified
Due 8 May 2007
Resolved 30 April 2007
Engineering › Steam Boiler (auxiliary/waste heat) › Valve, Relief
Issued 24 April 2007 Resolved
Proof test vessels' hot water heater relief valves (x2).
Action required: 705 - Other - as specified
Due 8 May 2007
Resolved 30 April 2007
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 24 April 2007 Resolved
Repair the NO.1 SSDG reverse power relay indicator light and on/off indicator light.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 May 2007
Resolved 30 May 2007
Resolution: Witnessed correct operation.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 24 April 2007 Resolved
Galley "E" light fixture is broken; lights work, however, unable to position one of the two lights.
Action required: 705 - Other - as specified
Due 8 May 2007
Resolved 30 May 2007
Resolution: Witnessed repair.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 24 April 2007 Resolved
Signage for portside engine room halon activation station faded and unreadable.
Action required: 705 - Other - as specified
Due 8 May 2007
Resolved 30 May 2007
Resolution: Witnessed new signs.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 24 April 2007 Resolved
Bow thruster room halon system failed to shut down ventilation.
Action required: 705 - Other - as specified
Due 8 May 2007
Resolved 30 May 2007
Resolution: Witnessed proper ventilation shut down.
Lifesaving › Inflatable Liferafts › Servicing
Issued 17 April 2007 Resolved
Life rafts taken off vessel for servicing; replaced with life floats during interim. Life rafts must be re-installed prior to getting underway with passengers.
Action required: 705 - Other - as specified
Due 17 May 2007
Resolved 9 May 2007
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 1 February 2007 Resolved
Replaced and destroyed 4 damaged lifejackets on 3rd deck.
Due 1 February 2007
Resolved 1 February 2007
Resolution: lifejackets replaced with new, during inspection.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 30 January 2007 Resolved
The fixed fire detecting system (smoke) in the # 10 void space is not working properly.
Condition: Unknown
Due 1 February 2007
Resolved 2 February 2007
Communications › Public Address System › Loudspeaker
Issued 31 October 2006 Resolved
Repair PA speakers in vessel crew break areas on the 2nd and 3rd decks speaker volume is too low for crew to hear.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 30 November 2006
Fire Fighting › Automatic Sprinkler System › Stop Valves
Issued 31 October 2006 Resolved
Properly renew tamper seal for the galley hood fire suppression system.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 November 2006
Resolved 30 November 2006
Fire Fighting › Automatic Sprinkler System › Connection to Fire Main
Issued 31 October 2006 Resolved
Repair or replace the galley stove hood vent louver, far left hand louver is damaged.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 March 2007
Resolved 11 December 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 31 October 2006 Resolved
Properly insulate neon lighting wiring throughout the vessel.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 April 2007
Resolved 10 July 2007
Resolution: Neon lighting connection points covered with insulated caps above bridge and throught vessel.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 14 July 2006 Resolved
Properly install exhaust lagging onto the No. 1,2, and 3 diesel generator exhaust system, including turbo charger.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 September 2006
Resolved 31 October 2006
Deck/Cargo › Holds/Tanks › Independent Tank
Issued 14 July 2006 Resolved
Properly clean and repair coating system on ships potable water tanks.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 14 September 2006
Resolved 31 October 2006
Accommodation/Occupational Safety › Potable Water System › General
Issued 14 July 2006 Resolved
Properly renew/repair wasted grey water drain piping in void 5.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 14 September 2006
Resolved 31 October 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 July 2006 Resolved
Properly remove dead end wires in voids 6 and 7, port and stbd side respectively.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 September 2006
Resolved 31 October 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 July 2006 Resolved
Properly tighten loose stern light on vessels power module.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 14 August 2006
Resolved 7 August 2006
Engineering › Thrusters › Hose
Issued 14 July 2006 Resolved
Renew all bow thruster hydraulic hoses with hoses that have been pressure tested.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 14 August 2006
Resolved 7 August 2006
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 14 July 2006 Resolved
Properly repair leaking fuel oil unions in vessels aft lazaret, fwd bulkhead, supply piping for the No. 2 SSDG.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 August 2006
Resolved 7 August 2006
Construction/Loadline › Hull › Hull Plating
Issued 10 July 2006 Resolved
Properly repair several 1/4" holes in overhead bulkhead void 9.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 14 August 2006
Resolved 7 August 2006
Accommodation/Occupational Safety › Occupational Safety › Smoking
Issued 19 April 2006 Resolved
Repair remove inop fire detector in soft count room. There are 2 detectors-one can be removed.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 May 2006
Resolved 1 May 2006
Resolution: Detector removed.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 19 April 2006 Resolved
Properly adjust fire door to proper gap. (# 8 fire door)
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 May 2006
Resolved 1 June 2006
Engineering › Steam Boiler (auxiliary/waste heat) › Gauge Glass
Issued 19 April 2006 Resolved
Repair inop auxilarry heating boiler gage.
Action required: 705 - Other - as specified
Resolved 1 June 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 19 April 2006 Resolved
Properly double clamp fuel hoses on bow thruster.
Action required: 705 - Other - as specified
Resolved 1 June 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Crankcase
Issued 19 April 2006 Resolved
Repair bow thruster fluid level indicator.
Action required: 705 - Other - as specified
Resolved 1 June 2006
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 21 January 2006 Resolved
Instructions for Fixed Fire Fighting system in the Rudder Room missing
Condition: Unknown
Due 1 February 2006
Resolved 25 January 2006
Resolution: Instructions were posted
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 21 January 2006 Resolved
Fire estinguishers number 50 and number 55 located in engine room main deck port side &hull deck center past annual service date.
Condition: Improper/Lack of Maintenance
Due 1 February 2006
Resolved 28 February 2006
Resolution: Extinguishers properly serviced
Fire Fighting › Fire Hydrants › Condition
Issued 21 January 2006 Resolved
Leaking Y valve on fire station #1 when fire pump energized
Condition: Improper/Lack of Maintenance
Due 1 February 2006
Resolved 28 February 2006
Resolution: Y valve was replaced
Electrical › Lighting (emergency) › Lighting Fixture
Issued 21 January 2006 Resolved
"E" lighting fixture in forward lobby main deck, center light not properly operating
Condition: Improper/Lack of Maintenance
Due 1 February 2006
Resolved 28 January 2006
Resolution: Light bulbs in fixture were replaced and operate properly
Electrical › Lighting (emergency) › Lighting Fixture
Issued 21 January 2006 Resolved
"E" lighting was not installed in Aft Stores loading area on power unit.
Condition: Unknown
Due 1 February 2006
Resolved 28 January 2006
Resolution: "E" lighting installed as required
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 18 January 2006 Resolved
Properly post operating instructions for the engine rooms fixed halon fire extinguishing system.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 February 2006
Resolved 13 March 2006
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 18 January 2006 Resolved
Properly service your two (x2) portable B-II fire extinguishers, located at stations 50 & 55 on your fire control plan.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 February 2006
Resolved 13 March 2006
Fire Fighting › Fire Hydrants › Condition
Issued 18 January 2006 Resolved
Properly repair leaking "Y" valve at fire station number one.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 February 2006
Resolved 13 March 2006
Electrical › Lighting (emergency) › Lighting Fixture
Issued 18 January 2006 Resolved
Properly repair the main deck, center bow, overhead "E" light. Did not energize while on emergency power and it has an "E" designator.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 February 2006
Resolved 13 March 2006
Electrical › Electrical Distribution System (service) › Bus Bar Connection
Issued 18 January 2006 Resolved
Properly install an emergency light in the cargo loading bay on the main deck. This area was extremely dark while on emergency power and has numerous tripping hazards.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 February 2006
Resolved 13 March 2006
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 17 October 2005 Resolved
Properly mount four (x4) fire extinguishers outside of the engine control room.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 24 October 2005
Resolved 8 November 2005
Engineering › Diesel Engine (auxiliary) › Block
Issued 17 October 2005 Resolved
Properly repair the No. 2 SSDG fan guard bracket, exiting bracket is loose, due to damaged treads on existing bracket.
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 October 2005
Resolved 8 November 2005
Fire Fighting › Nozzles › Condition
Issued 17 October 2005 Resolved
Properly repair or replace leaking fire nozzle on portside third deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 October 2005
Resolved 8 November 2005
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 22 July 2005 Resolved
Properly repair emergency lighting in the engine room repair shop. Light not coming on while on emergency power.
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 August 2005
Resolved 10 August 2005
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Overspeed Device
Issued 22 July 2005 Resolved
Properly repair overspeed trip/safety device on the NO.1 SSDG.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 10 August 2005
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 22 July 2005 Resolved
Properly repair the NO. 3 SSDG main distribution circuit breaker. Indicator shows on, after tripped off.
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 August 2005
Resolved 10 August 2005
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 22 July 2005 Resolved
Properly repair the first deck, port bow, lifering bouys', float light. Light will not turn on when activated.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 August 2005
Resolved 10 August 2005
Lifesaving › Lifefloat › Serviceable
Issued 22 July 2005 Resolved
Properly repair or replace life rings on port and starboard bridge wings.
Action required: 705 - Other - as specified
Due 22 August 2005
Resolved 10 August 2005
Electrical › Electrical Distribution System (service) › Switch
Issued 7 July 2005 Resolved
Properly repair main elevator prior to allowing passengers to use. Do not allow handicap passengers on the 1st and 3rd decks until the main elevator is properly repaired.
Action required: 705 - Other - as specified
Due 15 July 2005
Resolved 13 July 2005
Fire Fighting › Grease Extraction Hood › General
Issued 28 April 2005 Resolved
Prove proper operation of galley fire suppression system. the piping which has the cable with fusible links needs to have build up of grease removed from inside of piping or replace piping.
Due 28 April 2005
Resolved 28 April 2005
Resolution: All piping and fittings for cable were replaced with new pipe and fittings..
Electrical › Electric Generation Source (service) › Generator
Issued 28 April 2005 Resolved
Prove proper operation of # 1 generator's reverse power relay.
Condition: Unknown
Due 5 May 2005
Resolved 10 May 2005
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 28 April 2005 Resolved
Properly clean area IWO of hot dog cart area.
Due 5 May 2005
Resolved 10 May 2005
Electrical › Electrical Distribution System (service) › Switch
Issued 28 April 2005 Resolved
Properly repair stbd stage up lifting electrical switch.
Due 5 May 2005
Resolved 10 May 2005
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 28 April 2005 Resolved
Properly repair center main diesel engine low lube oil pressure indicator light in the pilot house.
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 May 2005
Resolved 28 April 2005
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 28 April 2005 Resolved
Properly repair reverse polarity condition on the weather deck, port side, stern 110v outlet on the power module.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 5 May 2005
Resolved 28 April 2005
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 28 April 2005 Resolved
Properly repair reverse polarity condition on the weather 02 deck, 110v recepticle, port side, forward.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 5 May 2005
Resolved 28 April 2005
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 28 April 2005 Resolved
Properly repair missing outlet cover on the 03 deck, 110v outlet located inside the cash cage (in the center of the couter top, at knee level).
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 5 May 2005
Resolved 28 April 2005
Electrical › Electrical Distribution System (service) › Conductor
Issued 28 April 2005 Resolved
Properly repair/remove stray wire, located behind the 03 deck bars ice machine.
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 May 2005
Resolved 28 April 2005
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 28 April 2005 Resolved
Properly install grounding cable to all of the data rooms 110v recepticles.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 5 May 2005
Resolved 10 May 2005
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 1 February 2005 Resolved
Properly label all electrical circuit breakers including spares breakers throughout the ship.
Condition: Placed in Improper Service
Due 31 March 2005
Resolved 9 March 2005
Communications › Alarms/Indicators › General Alarm
Issued 25 January 2005 Resolved
Prove proper operation of general alarm located at #1 deck fwd cage area.
Condition: Improper/Lack of Maintenance
Due 27 January 2005
Resolved 1 February 2005
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 25 January 2005 Resolved
Properly replace jacket water hose on emergency generator.
Condition: Unknown
Due 27 January 2005
Resolved 1 February 2005
Electrical › Electrical Distribution System (emergency) › Circuit Breaker
Issued 25 January 2005 Resolved
Properly label emergency circuit (#2 air compressor)
Condition: Placed in Improper Service
Due 27 January 2005
Resolved 1 February 2005
Fire Fighting › Fire Hoses › Condition
Issued 25 January 2005 Resolved
Properly stencil the vessels name on all ships fire fighting hoses.
Due 14 February 2005
Resolved 1 February 2005
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 25 January 2005 Resolved
Properly repair ships depth sounder.
Condition: Unknown
Due 26 February 2005
Resolved 1 February 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 January 2005 Resolved
Properly repair loose open wires in the galley air handler space.
Condition: Improper/Lack of Maintenance
Due 27 January 2005
Resolved 27 January 2005
Fire Fighting › Firemans Outfit › Axe
Issued 25 January 2005 Resolved
Properly secure loose axe head in the ships pantry.
Condition: Unknown
Due 14 February 2005
Resolved 1 February 2005
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 25 January 2005 Resolved
Properly clean dust and dirt from ships overhead panels on all decks.
Condition: Improper/Lack of Maintenance
Due 31 March 2005
Resolved 28 April 2005
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 25 January 2005 Resolved
Properly repair leaking soda dispensing valves in the liquor locker.
Condition: Damaged By Earlier Event
Due 14 February 2005
Resolved 1 February 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 25 January 2005 Resolved
Properly repair deck light, port aft green patio area (missing guard).
Condition: Damaged By Earlier Event
Due 26 February 2005
Resolved 1 February 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 25 January 2005 Resolved
Properly repair deck light fixture, second deck, portside aft (missing guard).
Condition: Damaged By Earlier Event
Due 26 February 2005
Resolved 1 February 2005
Personnel › Certificates/Documents/Licenses › License, Master
Issued 25 January 2005 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 28 January 2005
Resolved 27 January 2005
Electrical › Lighting (emergency) › Lighting Fixture
Issued 4 October 2004 Resolved
Replace all missing "E" designation marking on fourth deck, weather deck, emergency lighting fixtures; worn off by the weather.
Condition: Improper/Lack of Maintenance
Due 27 November 2004
Resolved 15 November 2004
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 4 October 2004 Resolved
Renew all donning instructions on the fourth deck lifejacket storage lockers. Existing instructions are weather damaged and hard to read.
Condition: Improper/Lack of Maintenance
Due 27 November 2004
Resolved 15 November 2004
Electrical › Lighting (service) › Lighting Fixture
Issued 4 October 2004 Resolved
Replace the twelve missing globes/guards on weather deck light fixtures.
Condition: Improper/Lack of Maintenance
Due 27 November 2004
Resolved 15 November 2004
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 4 October 2004 Resolved
Properly equip two liferings with ninety feet of bouyant lifeline as required by your COI.
Condition: Improper Installation
Due 27 November 2004
Resolved 15 November 2004
Lifesaving › Lifebuoys › Serviceable
Issued 4 October 2004 Resolved
Renew the six weather damaged liferings found throughout the ship during this inspection.
Condition: Improper/Lack of Maintenance
Due 27 November 2004
Resolved 15 November 2004
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 October 2004 Resolved
Renew the aft top amber light fixture, fixture is corroded needs to be renewed.
Condition: Improper/Lack of Maintenance
Due 27 November 2004
Resolved 15 November 2004
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 27 July 2004 Resolved
Liquor locker electrical recepticle located by the desk just as you enter the space has an open ground on both outlets on the wall recepticle.
Condition: Unknown
Due 27 August 2004
Resolved 18 August 2004
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 27 July 2004 Resolved
Temperture control valve on the second deck air handler is leaking water. Repair leaking valve.
Condition: Unknown
Due 27 August 2004
Resolved 18 August 2004
Fire Fighting › Firemans Outfit › Axe
Issued 27 July 2004 Resolved
Properly stencil the vessels name on the fire axe located at the stbd side second deck bar.
Condition: Improper/Lack of Maintenance
Due 27 August 2004
Resolved 18 August 2004
Electrical › Electrical Distribution System (service)
Issued 6 April 2004 Resolved
Identify and repair open ground to UPS #22 (pantry and River View Grill). LEGACY COMPONENT DESC: Outlet Box
Condition: Improper Installation
Due 20 May 2004
Resolved 11 May 2004
Electrical › Lighting (emergency)
Issued 6 April 2004 Resolved
Properly repair emergency light in galley. LEGACY COMPONENT DESC: Battery Operated Lantern
Condition: Improper/Lack of Maintenance
Due 20 May 2004
Resolved 11 May 2004
Electrical › Electrical Distribution System (service)
Issued 6 April 2004 Resolved
Repair both outlets on elevator bulkhead in galley. LEGACY COMPONENT DESC: Outlet Box
Condition: Improper/Lack of Maintenance
Due 20 May 2004
Resolved 11 May 2004
Accommodation/Occupational Safety › Medical/First Aid
Issued 6 April 2004 Resolved
Replaced expired (03/03) eyewash solution in galley. LEGACY COMPONENT DESC: Eyewash Station
Condition: Improper/Lack of Maintenance
Due 20 May 2004
Resolved 11 May 2004
Electrical › Electrical Distribution System (service)
Issued 6 April 2004 Resolved
Repair inoperable outlet on bulkhead to River View Grill from non-smoking section. LEGACY COMPONENT DESC: Outlet Box
Condition: Improper/Lack of Maintenance
Due 20 May 2004
Resolved 11 May 2004
Engineering › Diesel Engine (auxiliary)
Issued 6 April 2004 Resolved
Repair or replace hydraulic hose on stern thruster. LEGACY COMPONENT DESC: Hydraulic Hoses
Condition: Improper/Lack of Maintenance
Due 20 May 2004
Resolved 11 May 2004
Electrical › Electrical Distribution System (service)
Issued 6 April 2004 Resolved
Properly label breaker box P9. LEGACY COMPONENT DESC: Panelboard
Condition: Placed in Improper Service
Due 20 May 2004
Resolved 11 May 2004
Engineering › Diesel Engine (auxiliary)
Issued 6 April 2004 Resolved
Prove proper operation of generator #2 high jacket water temperature shutdown alarm. LEGACY COMPONENT DESC: Alarms
Condition: Unknown
Due 20 May 2004
Resolved 11 May 2004
Electrical › Electric Generation Source (service)
Issued 22 January 2004 Resolved
Prove proper operation of reverse power relay on # 3 SSDG. LEGACY COMPONENT DESC: Generator
Condition: Unknown
Due 22 February 2004
Resolved 1 March 2004
Resolution: Installed new relay.
Electrical › Electric Generation Source (service)
Issued 22 January 2004 Resolved
Replace fuel solenoid on #1 SSDG. LEGACY COMPONENT DESC: fuel solenoid
Condition: Unknown
Due 22 February 2004
Resolved 11 February 2004
Electrical › Electric Generation Source (service)
Issued 22 January 2004 Resolved
Prove proper operation of emergency shutdowns on #1 SSDG. LEGACY COMPONENT DESC: Generator
Condition: Unknown
Due 22 February 2004
Resolved 11 February 2004
Fire Fighting › Structural - A Class Divisions
Issued 22 January 2004 Resolved
Prove proper operation of fire screen doors #6 and 7. LEGACY COMPONENT DESC: Openings - Fire Doors
Condition: Improper/Lack of Maintenance
Due 22 February 2004
Resolved 11 February 2004
Engineering › Thrusters
Issued 21 November 2003 Resolved
Properly repair diesel fuel leak on bow thruster IWO stbd fuel injector. LEGACY COMPONENT DESC: Seal
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 24 November 2003
Resolved 24 December 2003
Engineering › Thrusters
Issued 21 November 2003 Resolved
Properly repair hydraulic oil leak on bow thruster IWO gauge line swivel. LEGACY COMPONENT DESC: Hose
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 24 November 2003
Resolved 24 December 2003
Fire Fighting › Firemans Outfit
Issued 22 October 2003 Resolved
Make proper repairs to SCBA #BRLL-1226. LEGACY COMPONENT DESC: Self-Contained Breathing Apparatus
Condition: Improper/Lack of Maintenance
Due 22 November 2003
Resolved 11 February 2004
Electrical › Electrical Distribution System (service)
Issued 22 October 2003 Resolved
Remove dead end wires in forward 3rd deck port air handler and 1st deck forward cage. LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Due 22 November 2003
Resolved 21 November 2003
Accommodation/Occupational Safety › Messroom
Issued 22 October 2003 Resolved
Replace gauge on nitrogen cylinder regulator in liquor room. LEGACY COMPONENT DESC: Beverage Distribution System
Condition: Improper/Lack of Maintenance
Due 22 November 2003
Resolved 21 November 2003
Accommodation/Occupational Safety › Messroom
Issued 22 October 2003 Resolved
Remove moldy insulation and properly clean insulation to beer tap in 2nd deck port bar. LEGACY COMPONENT DESC: Cleanliness
Condition: Improper/Lack of Maintenance
Due 22 November 2003
Resolved 11 February 2004
Electrical › Electrical Distribution System (service)
Issued 22 October 2003 Resolved
Add firestop to wire run in 2nd deck sound room. LEGACY COMPONENT DESC: Wiring
Condition: Placed in Improper Service
Due 22 November 2003
Resolved 21 November 2003
Accommodation/Occupational Safety › Messroom
Issued 22 October 2003 Resolved
Clean out under sandwich and soda display cases in hot dog stand. LEGACY COMPONENT DESC: Cleanliness
Condition: Improper/Lack of Maintenance
Due 22 November 2003
Resolved 21 November 2003
Electrical › Electrical Distribution System (service)
Issued 22 October 2003 Resolved
Properly label breaker boxes L8 and L19. LEGACY COMPONENT DESC: Panelboard
Condition: Placed in Improper Service
Due 22 November 2003
Resolved 21 November 2003
Engineering › Diesel Engine (auxiliary)
Issued 22 October 2003 Resolved
Properly repair exhaust leak on bow thruster. LEGACY COMPONENT DESC: Exhaust
Condition: Improper/Lack of Maintenance
Due 22 November 2003
Resolved 21 November 2003
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 22 October 2003 Resolved
Properly inspect fire extinguishers in porters office, tow boat chiller room and void 2 (electrical storage room). LEGACY COMPONENT DESC: Service
Condition: Improper/Lack of Maintenance
Due 22 November 2003
Resolved 21 November 2003
Documentation › Safety/Response Plans/Programs
Issued 24 July 2003 Resolved
Update and renew vessel fire control plan. LEGACY COMPONENT DESC: Fire Control Plans
Condition: Placed in Improper Service
Due 24 August 2003
Resolved 22 August 2003
Accommodation/Occupational Safety › Refrigeration (air conditioning)
Issued 24 July 2003 Resolved
Remove mold and fungus from air handlers throughout vessel. LEGACY COMPONENT DESC: Air handlers
Condition: Improper/Lack of Maintenance
Due 24 August 2003
Resolved 22 August 2003
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 24 July 2003 Resolved
Remove moldy insulation from 2nd deck port bar insulation, clean glass and debris from bar deck. LEGACY COMPONENT DESC: 2nd deck bar
Condition: Improper/Lack of Maintenance
Due 24 August 2003
Resolved 22 August 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 24 July 2003 Resolved
Remove electrical outlet from deck in 2nd deck port bar. LEGACY COMPONENT DESC: Receptacle Outlet
Condition: Placed in Improper Service
Due 24 August 2003
Resolved 22 August 2003
Electrical › Electrical Distribution System (service)
Issued 24 July 2003 Resolved
Seal wire run in computer data room and remove all dead end wires. LEGACY COMPONENT DESC: Wiring
Condition: Placed in Improper Service
Due 24 August 2003
Resolved 22 August 2003
Fire Fighting › Structural - A Class Divisions
Issued 24 July 2003 Resolved
Repair fire door #6 and #5 gap and door latch. LEGACY COMPONENT DESC: Openings - Fire Doors
Condition: Improper/Lack of Maintenance
Due 24 August 2003
Resolved 22 August 2003
Lifesaving › Lifebuoys
Issued 24 July 2003 Resolved
Replace forward port life buoy.
Condition: Improper/Lack of Maintenance
Due 24 August 2003
Resolved 22 August 2003
Engineering › Diesel Engine (auxiliary)
Issued 24 July 2003 Resolved
Properly install exhaust insulation on bow thruster engine exhaust. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Placed in Improper Service
Due 24 August 2003
Resolved 22 August 2003
Electrical › Electric Generation Source (service)
Issued 24 July 2003 Resolved
Prove proper operation of the #3 Ship's Service Diesel Generator. LEGACY COMPONENT DESC: Generator
Condition: Damaged By Earlier Event
Due 24 August 2003
Resolved 22 August 2003
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 24 July 2003 Resolved
Replace broken glass on fixed CO2 system activation station for the bow thruster room. LEGACY COMPONENT DESC: Operating Controls
Condition: Improper/Lack of Maintenance
Due 24 August 2003
Resolved 22 August 2003
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 24 July 2003 Resolved
Properly inspect portable fire extinguisher in tow boat elevator space. LEGACY COMPONENT DESC: Service
Condition: Improper/Lack of Maintenance
Due 24 August 2003
Resolved 22 August 2003
Engineering › Thrusters
Issued 24 April 2003 Resolved
Show proper operation of jacket water high temperature alarm on stern thruster and bridge slot office heat detector. LEGACY COMPONENT DESC: Alarms and Safeties
Condition: Improper/Lack of Maintenance
Due 24 May 2003
Resolved 16 May 2003
Electrical › Electrical Distribution System (service)
Issued 24 April 2003 Resolved
Install new panel directories in all electrical panels identifying breakers throughout vessel. LEGACY COMPONENT DESC: Panelboard
Condition: Improper/Lack of Maintenance
Due 24 May 2003
Resolved 16 May 2003
Accommodation/Occupational Safety › Messroom
Issued 24 April 2003 Resolved
Replace both ice bins in 2nd deck port forward bar. Do not use aft ice bin at waitress station until replaced. LEGACY COMPONENT DESC: Ice Recepticals
Condition: Improper/Lack of Maintenance
Due 24 May 2003
Resolved 16 May 2003
Personnel › Training
Issued 8 April 2003 Resolved
Provide training to crew and security personnel to meet minimum standards for fire fighting duties. LEGACY COMPONENT DESC: Fire Fighting Basic
Condition: Unknown
Due 24 April 2003
Resolved 16 May 2003
Deck/Cargo › Mooring/Anchoring
Issued 28 February 2003 Resolved
Requirement cleared in error, Properly mouse all safety shackles on loading ramps and anchor davits.
Condition: Improper/Lack of Maintenance
Due 3 March 2003
Resolved 3 March 2003
Electrical › Lighting (emergency)
Issued 3 February 2003 Resolved
Show proper operationof emergency lighting on 3rd deck and 4th deck in way of portside ladder. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Due 3 March 2003
Resolved 28 February 2003
Electrical › Lighting (emergency)
Issued 3 February 2003 Resolved
Properly label emergency lighting on 2nd deck portside. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Due 3 March 2003
Resolved 28 February 2003
Electrical › Electrical Distribution System (service)
Issued 3 February 2003 Resolved
Install weathertight cover over toggle switch on the 3rd deck, starboard side. LEGACY COMPONENT DESC: Switch
Condition: Unknown
Due 3 March 2003
Resolved 28 February 2003
Deck/Cargo
Issued 3 February 2003 Resolved
Mouse all safety shackles on loading ramp and anchor davits.
Condition: Improper Installation
Due 3 March 2003
Resolved 28 February 2003
Fire Fighting › Means of Escape
Issued 3 February 2003 Resolved
Renew latch on emergency egress door adjacent to slot slot #585. 2nd deck. LEGACY COMPONENT DESC: Doorways
Condition: Unknown
Due 3 March 2003
Resolved 28 February 2003
Accommodation/Occupational Safety › Ventilation
Issued 3 February 2003 Resolved
Repair or replace frozen valve on air handler #6.
Condition: Unknown
Due 3 March 2003
Resolved 28 February 2003
Accommodation/Occupational Safety › Ventilation
Issued 3 February 2003 Resolved
Remove fungus in air handler #6.
Condition: Improper/Lack of Maintenance
Due 3 March 2003
Resolved 28 February 2003
Accommodation/Occupational Safety
Issued 3 February 2003 Resolved
Cap Sewage drain pipe located in the 2nd deck electrical space.
Condition: Unknown
Due 3 March 2003
Resolved 28 February 2003
Accommodation/Occupational Safety › Messroom
Issued 3 February 2003 Resolved
Properly secure compressed cylinders in the helps hall.
Condition: Unknown
Due 3 March 2003
Resolved 28 February 2003
Accommodation/Occupational Safety › Potable Water System
Issued 3 February 2003 Resolved
Properly repair sink drain in galley at the dishwasher station.
Condition: Unknown
Due 3 March 2003
Resolved 28 February 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 3 February 2003 Resolved
Properly repair cracks at base of safety railing on the starboard bow loading ramp. LEGACY COMPONENT DESC: Deck Rail
Condition: Unknown
Due 3 March 2003
Resolved 28 February 2003
Fire Fighting › Combustible Materials
Issued 3 February 2003 Resolved
Remove all flammables from the galley cleaning locker. LEGACY COMPONENT DESC: Paints/Varnishes/Other Finishes
Condition: Unknown
Due 3 March 2003
Resolved 3 February 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 3 February 2003 Resolved
Properly repair deck railing on the starboard side of the main deck. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper/Lack of Maintenance
Due 3 March 2003
Resolved 28 February 2003
Electrical › Electrical Distribution System (service)
Issued 1 November 2002 Resolved
Replace cover to main breaker for starboard neon light power panel. LEGACY COMPONENT DESC: Metallic Enclosure/Frame
Condition: Improper Installation
Due 1 December 2002
Resolved 27 November 2002
Electrical › Electric Generation Source (service)
Issued 1 November 2002 Resolved
Replace main circuit breaker for #3 Ship Service generator and prove proper operation of same. LEGACY COMPONENT DESC: Circuit Breaker
Condition: Unknown
Due 1 December 2002
Resolved 27 November 2002
Electrical › Electric Generation Source (service)
Issued 1 November 2002 Resolved
Repair/Replace selector switch for #3 generator and prove proper operation. LEGACY COMPONENT DESC: Switch
Condition: Unknown
Due 1 December 2002
Resolved 27 November 2002
Engineering › Steering Gear System
Issued 1 November 2002 Resolved
Label all steeing gear alarms in pilothouse and the engineroom control booth.
Condition: Unknown
Due 1 December 2002
Resolved 27 November 2002
Electrical
Issued 1 November 2002 Resolved
Remove portable heater in housekeeping office and install hard wired heater if needed.
Condition: Improper Installation
Due 1 December 2002
Resolved 27 November 2002
Accommodation/Occupational Safety
Issued 1 November 2002 Resolved
Remove carpet from the #7P void.
Condition: Improper/Lack of Maintenance
Due 1 December 2002
Resolved 27 November 2002
Electrical
Issued 1 November 2002 Resolved
Identify and repair forward elevator relay chattering problem.
Condition: Unknown
Due 1 December 2002
Resolved 27 November 2002
Fire Fighting › Fire Pumps
Issued 1 November 2002 Resolved
Replace #1 Fire pump gauge.
Due 1 December 2002
Resolved 27 November 2002
Electrical › Electrical Distribution System (service)
Issued 1 November 2002 Resolved
Remove and properly wire power supply to work barge and secure cover to neon lighting power panel portside. LEGACY COMPONENT DESC: Distribution Panel Bus
Condition: Improper Installation
Due 1 December 2002
Resolved 27 November 2002
Lifesaving › Rescue Boat Equipment
Issued 1 November 2002 Resolved
Prove proper operation of navigation lights on forward rescue boat.
Condition: Unknown
Due 1 December 2002
Resolved 27 November 2002
Deck/Cargo
Issued 1 November 2002 Resolved
Mouse all load bearing screw pin shackles or replace with safety shackles.
Condition: Improper Installation
Due 1 December 2002
Resolved 27 November 2002
Engineering
Issued 1 November 2002 Resolved
Properly clean machinery, horizontal surfaces and vents in the hard count room.
Condition: Improper/Lack of Maintenance
Due 1 December 2002
Resolved 27 November 2002
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 31 July 2002 Resolved
Properly clean all decks located in service bars. LEGACY COMPONENT DESC: BARS
Condition: Improper/Lack of Maintenance
Due 31 August 2002
Resolved 23 August 2002
Lifesaving › Rescue Boat Equipment
Issued 31 July 2002 Resolved
Properly install wire rope clips on aft Rescue boat davit. LEGACY COMPONENT DESC: davit
Condition: Placed in Improper Service
Due 29 August 2002
Resolved 31 July 2002
Deck/Cargo › Cargo Stowage
Issued 31 July 2002 Resolved
Properly install wire rope clips on stbd 4th deck davit. LEGACY COMPONENT DESC: 4th Deck davit
Condition: Improper Installation
Due 31 August 2002
Resolved 23 August 2002
Electrical › Electrical Distribution System (service)
Issued 1 May 2002 Resolved
Prove proper operation of ground detector panel L-13. LEGACY COMPONENT DESC: Ground Detection
Condition: Improper/Lack of Maintenance
Due 1 June 2002
Resolved 29 May 2002
Electrical › Electrical Distribution System (service)
Issued 1 May 2002 Resolved
Properly wire survellance room IAW Subchapter J of 46 CFR. LEGACY COMPONENT DESC: Wiring
Condition: Placed in Improper Service
Due 1 June 2002
Resolved 29 May 2002
Fire Fighting › Combustible Materials
Issued 1 May 2002 Resolved
Remove fire hazards (trash and excess debris) from all office spaces.
Condition: Placed in Improper Service
Due 1 June 2002
Resolved 29 May 2002
Fire Fighting › Combustible Materials
Issued 1 May 2002 Resolved
Ensure all trash cans onboard are non-combustible. LEGACY COMPONENT DESC: Trash Cans
Condition: Placed in Improper Service
Due 1 June 2002
Resolved 29 May 2002
Stability › Watertight Integrity
Issued 1 May 2002 Resolved
Regasket WTDs #1 and #2 ensuring no gaps or splices in gasket. LEGACY COMPONENT DESC: WTD Gaskets
Condition: Improper/Lack of Maintenance
Due 1 June 2002
Resolved 29 May 2002
Fire Fighting › Combustible Materials
Issued 1 May 2002 Resolved
Clean out and properly store supplies in Void #3. Segregate corrosives and flammables. Ensure all containers are sealed and in proper containment. Remove duct tape acting as container lid. LEGACY COMPONENT DESC: Cleaning Stores
Condition: Improper/Lack of Maintenance
Due 1 June 2002
Resolved 29 May 2002
Lifesaving › Inflatable Liferafts
Issued 1 May 2002 Resolved
Provide liferaft service reports. LEGACY COMPONENT DESC: Service Report
Condition: Improper/Lack of Maintenance
Due 1 June 2002
Resolved 29 May 2002
Electrical › Electrical Distribution System (service)
Issued 1 May 2002 Resolved
Support all wire runs in overhead on 1st, 2nd, and 3rd decks. LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Due 29 July 2002
Resolved 31 July 2002
Accommodation/Occupational Safety › Messroom
Issued 1 May 2002 Resolved
Provide sanitary procedures for galley to ensure food prep and galley employees know proper cleaning skills and food handling procedures. LEGACY COMPONENT DESC: Sanitary Procedures
Condition: Placed in Improper Service
Due 1 June 2002
Resolved 29 May 2002
Fire Fighting › Structural - A Class Divisions
Issued 1 May 2002 Resolved
Show proper operation of FSD #6. LEGACY COMPONENT DESC: Openings - Fire Doors
Condition: Improper/Lack of Maintenance
Due 1 June 2002
Resolved 29 May 2002
Documentation › Safety/Response Plans/Programs
Issued 1 May 2002 Resolved
Display updated fire control plan on bridge. LEGACY COMPONENT DESC: Fire Control Plans
Condition: Improper/Lack of Maintenance
Due 1 June 2002
Resolved 29 May 2002
Fire Fighting › Grease Extraction Hood
Issued 18 April 2002 Resolved
Properly clean all duct work, piping and adjacent areas for galley hood system removing accumulated grease.
Condition: Improper/Lack of Maintenance
Due 18 May 2002
Resolved 29 May 2002
Fire Fighting › Grease Extraction Hood
Issued 18 April 2002 Resolved
Relabel alarms in engine room and bridge for galley hood extinguishing system.
Condition: Improper/Lack of Maintenance
Due 18 May 2002
Resolved 1 May 2002
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 8 April 2002 Resolved
Properly service fixed Halon system IAW 46 CFR 71.25-20. Until such time, vessel shall maintain a live Fire watch in the engineroom. LEGACY COMPONENT DESC: Quantity of Halon
Condition: Improper/Lack of Maintenance
Due 17 April 2002
Resolved 11 April 2002
Resolution: Halon bottles were serviced and re-installed in vessel. See vessel file for Fire Safety Inc. Service report.
Electrical › Electrical Distribution System (service)
Issued 25 January 2002 Resolved
Properly cover electrical box and secure dead end wires in junction box located in void #3. LEGACY COMPONENT DESC: Junction Box
Condition: Improper Installation
Due 28 February 2002
Resolved 26 February 2002
Electrical › Electrical Distribution System (service)
Issued 25 January 2002 Resolved
Properly secure dead end wiring in void #7, port side. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Due 26 February 2002
Resolved 25 January 2002
Electrical › Electrical Distribution System (service)
Issued 25 January 2002 Resolved
Properly seal fire stops through water tight bulkheads where wiring goes through the bulkhead thoughout void spaces and in coinage space. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Due 28 February 2002
Resolved 26 February 2002
Stability › Watertight Integrity
Issued 25 January 2002 Resolved
Properly seal holes in aft bulkhead in void #7. LEGACY COMPONENT DESC: bulkheads
Condition: Improper/Lack of Maintenance
Due 28 February 2002
Resolved 26 February 2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 25 January 2002 Resolved
Verify proper alarm settings and shutdowns on #2 SSDG and starboard main diesel engine. LEGACY COMPONENT DESC: Safety alarms
Condition: Improper/Lack of Maintenance
Due 28 February 2002
Resolved 26 February 2002
Engineering › Bilge Water Management System
Issued 25 January 2002 Resolved
Display bilge suction diagram with all in-line valves for each suction in each void. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Due 28 February 2002
Resolved 26 February 2002
Engineering › Thrusters
Issued 25 January 2002 Resolved
Repair bow thruster prime mover fuel shutoff valve. LEGACY COMPONENT DESC: prime mover fuel shutoff valve
Condition: Improper Installation
Due 26 February 2002
Resolved 26 February 2002
Fire Fighting › Structural Fire Protection - General
Issued 25 January 2002 Resolved
Adjust fire screen doors thoughout vessel to proper clearances as per 46 CFR 72.05. LEGACY COMPONENT DESC: Fire screen doors
Condition: Improper Installation
Due 28 February 2002
Resolved 26 February 2002
Accommodation/Occupational Safety
Issued 7 November 2001 Resolved
PROPERLY CLEAN ICE MACHINE LOCATED ON 3RD DECK AFT BAR.
Condition: Unknown
Due 7 November 2001
Resolved 7 November 2001
Electrical
Issued 7 November 2001 Resolved
PROPERLY SECURE WIRE RUNS IN HARD COUNT ROOM.
Condition: Unknown
Due 7 November 2001
Resolved 7 November 2001
Accommodation/Occupational Safety
Issued 7 November 2001 Resolved
REPAIR FLOOR IN LOUNGE #2 BAR, PROPERLY CLEAN FLOOR AND UNDER SINKS.
Condition: Unknown
Due 7 November 2001
Resolved 7 November 2001
Electrical
Issued 7 November 2001 Resolved
REMOVE DEAD END WIRES IN LOUNGE #1 BAR
Condition: Unknown
Due 7 November 2001
Resolved 7 November 2001
Fire Fighting
Issued 7 November 2001 Resolved
Test and make necessary repairs to fire screen doors throughout vessel.
Condition: Unknown
Due 3 February 2002
Resolved 5 February 2002
Resolution: Repairs made to doors.
Electrical
Issued 7 November 2001 Resolved
Perform required testing of emergency diesel generator and emergency lighting systems.
Condition: Unknown
Due 7 November 2001
Resolved 7 November 2001
Lifesaving
Issued 7 November 2001 Resolved
Ensure all first aid kits are complete and not expired throughout vessel.
Condition: Unknown
Due 7 November 2001
Resolved 7 November 2001
Electrical
Issued 7 November 2001 Resolved
Perform required testing of reverse power relays.
Condition: Unknown
Due 7 November 2001
Resolved 7 November 2001
Lifesaving
Issued 7 November 2001 Resolved
Test and make repairs to public address system throughout the vessel.
Condition: Unknown
Due 7 November 2001
Resolved 7 November 2001
Lifesaving
Issued 27 August 2001 Resolved
Prove proper operation of life ring float light.
Condition: Unknown
Due 27 August 2001
Resolved 27 August 2001
Electrical
Issued 27 August 2001 Resolved
Repair damaged receptacles and covers throughout vessel.
Condition: Unknown
Due 27 August 2001
Resolved 27 August 2001
Electrical
Issued 27 August 2001 Resolved
Install panel directory in panel L-11.
Condition: Unknown
Due 27 August 2001
Resolved 27 August 2001
Electrical
Issued 27 August 2001 Resolved
Properly wire first deck bar ice machine.
Condition: Unknown
Due 27 August 2001
Resolved 27 August 2001
Accommodation/Occupational Safety
Issued 27 August 2001 Resolved
Repair insect screen on potable water tank vent, main deck starboard side.
Condition: Unknown
Due 27 August 2001
Resolved 27 August 2001
Electrical
Issued 27 August 2001 Resolved
Remove homemade locking bar on breaker 32, panel L-3 and install a UL_x001C_ approved device.
Condition: Unknown
Due 27 August 2001
Resolved 27 August 2001
Lifesaving
Issued 27 August 2001 Resolved
Correct P/A feedback problem.
Condition: Unknown
Due 27 August 2001
Resolved 27 August 2001
Accommodation/Occupational Safety
Issued 27 August 2001 Resolved
Clean under coffee bar in helps hall, and all decks in galley including under stoves and grills.
Condition: Unknown
Due 27 August 2001
Resolved 27 August 2001
Electrical
Issued 27 August 2001 Resolved
Repair hanging deck light, 3rd deck starboard side.
Condition: Unknown
Due 27 August 2001
Resolved 27 August 2001
Deck/Cargo
Issued 2 May 2001 Resolved
ENSURE FOURTH DECK WINCH IS RATED FOR OVERHEAD LIFTING PRIOR TO USE.
Condition: Unknown
Due 2 May 2001
Resolved 2 May 2001
Engineering
Issued 2 May 2001 Resolved
CONDUCT TEST OF ALL INSTALLED MACHINERY SAFETY DEVICES AND SHUTDOWNS, AND DEVELOP WRITTEN STANDARD TEST PROCEEDURES.
Condition: Unknown
Due 2 May 2001
Resolved 2 May 2001
Electrical
Issued 2 May 2001 Resolved
RENEW ALL DAMAGED BATTERY BOXES IN MACHINERY SPACES.
Condition: Unknown
Due 2 May 2001
Resolved 2 May 2001
Construction/Loadline
Issued 2 May 2001 Resolved
PROPERLY LABEL BILGE HIGH LEVEL ALARMS IN WHEELHOUSE.
Condition: Unknown
Due 2 May 2001
Resolved 2 May 2001
Accommodation/Occupational Safety
Issued 2 May 2001 Resolved
CLEAN SEWAGE AND DEBRIS FROM PORTERS OFFICE BILGE LOCATED IN VOID 10.
Condition: Unknown
Due 2 May 2001
Resolved 2 May 2001
Fire Fighting
Issued 2 May 2001 Resolved
PROVE PROPER OPERATION OF NO. 1 FIRE PUMP GAUGE.
Condition: Unknown
Due 2 May 2001
Resolved 2 May 2001
Accommodation/Occupational Safety
Issued 2 May 2001 Resolved
ENSURE ALL EXTERIOR DOORS LATCH.
Condition: Unknown
Due 2 May 2001
Resolved 2 May 2001
Engineering
Issued 2 May 2001 Resolved
PROVE PROPER OPERATION OF THE CENTER AND PORT PROPULSION SHAFT TACHOMETERS.
Condition: Unknown
Due 2 May 2001
Resolved 2 May 2001
Construction/Loadline
Issued 2 May 2001 Resolved
PROVE PROPER OPERATION OF THE PORT LAZARETTE BILGE SUCTION.
Condition: Unknown
Due 2 May 2001
Resolved 2 May 2001
Accommodation/Occupational Safety
Issued 1 February 2001 Resolved
REPLACE GLASS IN ENGINE ROOM CONTROL BOOTH.
Condition: Unknown
Due 1 February 2001
Resolved 1 February 2001
Deck/Cargo
Issued 1 February 2001 Resolved
REPAIR L/O LEAK ON BOW THRUSTER
Condition: Unknown
Due 1 February 2001
Resolved 1 February 2001
Electrical
Issued 1 February 2001 Resolved
PROPERLY WIRE AFT SMALL BOAT BATTERY CHARGER.
Condition: Unknown
Due 1 February 2001
Resolved 1 February 2001
Fire Fighting
Issued 1 February 2001 Resolved
PROVE PROPER OPERATION OF F/S DOOR #8
Condition: Unknown
Due 1 February 2001
Resolved 1 February 2001
Fire Fighting
Issued 1 February 2001 Resolved
PROPERLY LABEL ALL AFT 1ST AND 3RD DECK FIRE DOORS AN ENSURE THEY OPERATE AND LATCH PROPERLY.
Condition: Unknown
Due 1 February 2001
Resolved 1 February 2001
Electrical
Issued 1 February 2001 Resolved
PROPERLY WIRE PORT SIDE 3RD DECK LOBBY OVERHEAD, USE APPROVED WIRE RUNS & HANGERS.
Condition: Unknown
Due 1 February 2001
Resolved 1 February 2001
Accommodation/Occupational Safety
Issued 1 February 2001 Resolved
PROPERLY REPAIR LATCH ON A/H #8 DOOR.
Condition: Unknown
Due 1 February 2001
Resolved 1 February 2001
Lifesaving
Issued 1 February 2001 Resolved
INSTALL WIRE ROPE CLIP ON 4TH DECK AFT DAVIT.
Condition: Unknown
Due 1 February 2001
Resolved 1 February 2001
Lifesaving
Issued 1 February 2001 Resolved
INSTALL SNAP HOOK ON 4TH DECK DAVIT.
Condition: Unknown
Due 1 February 2001
Resolved 1 February 2001
Navigation
Issued 1 February 2001 Resolved
PROVIDE PROOF OF NAUTICAL PUBS.
Condition: Unknown
Due 1 February 2001
Resolved 1 February 2001
Electrical
Issued 1 February 2001 Resolved
PROVE PROPER OPERATION OF #3 GENERATOR.
Condition: Unknown
Due 1 February 2001
Resolved 1 February 2001
Electrical
Issued 24 October 2000 Resolved
Properly wire (hardwire) crew break room soda machine pump.
Condition: Unknown
Due 24 October 2000
Resolved 24 October 2000
Electrical
Issued 24 October 2000 Resolved
Properly wire overhead, above fwd end of second deck bar, stbd side.
Condition: Unknown
Due 24 October 2000
Resolved 24 October 2000
Electrical
Issued 24 October 2000 Resolved
Properly wire first deck port side ATM machine.
Condition: Unknown
Due 24 October 2000
Resolved 24 October 2000
Electrical
Issued 24 October 2000 Resolved
REPLACE POWER CORD (SPLIT) AND HARD WIRE FIRST DECK HOT DOG CART.
Condition: Unknown
Due 24 October 2000
Resolved 24 October 2000
Engineering
Issued 24 October 2000 Resolved
Ensure proper operation of bridge console stbd engine PSI gauge, center engine RPM and temperature gauge.
Condition: Unknown
Due 24 October 2000
Resolved 24 October 2000
Accommodation/Occupational Safety
Issued 24 October 2000 Resolved
Properly insolate chilled water line in overhead, stbd side, 1-rear.
Condition: Unknown
Due 24 October 2000
Resolved 24 October 2000
Electrical
Issued 24 October 2000 Resolved
PROVE PROPER OPERATION OF VESSEL STERN LIGHTS UNDER E-POWER.
Condition: Unknown
Due 24 October 2000
Resolved 24 October 2000
Electrical
Issued 24 October 2000 Resolved
Properly wire second deck, fwd, stbd side, 5-progressive sign.
Condition: Unknown
Due 24 October 2000
Resolved 24 October 2000
Electrical
Issued 24 October 2000 Resolved
Properly wire overhead above second deck electrical room. Ensure wires are installed in wire runs.
Condition: Unknown
Due 24 October 2000
Resolved 24 October 2000
Accommodation/Occupational Safety
Issued 24 October 2000 Resolved
Properly clean galley return air vents.
Condition: Unknown
Due 24 October 2000
Resolved 24 October 2000
Deck/Cargo
Issued 3 August 2000 Resolved
Mouse all shackles on rescue boats.
Condition: Unknown
Due 19 October 2000
Resolved 23 October 2000
Electrical
Issued 3 August 2000 Resolved
Secure electrical outlet in first deck gaming area tables 2, 3, and 4.
Condition: Unknown
Due 19 October 2000
Resolved 23 October 2000
Lifesaving
Issued 3 August 2000 Resolved
PROVE PROPER OPERATION OF #1 GEN LUBE OIL TEMP ALARM
Condition: Unknown
Due 3 August 2000
Resolved 3 August 2000
Fire Fighting
Issued 3 August 2000 Resolved
Update and submit fire control plan to reflect changes.
Condition: Unknown
Due 19 October 2000
Resolved 23 October 2000
Accommodation/Occupational Safety
Issued 3 August 2000 Resolved
Repair pantry deck covering.
Condition: Unknown
Due 19 October 2000
Resolved 23 October 2000
Lifesaving
Issued 3 August 2000 Resolved
Remove excess stores from voids 2,3,8,9, and 10. Submit fire load calc's per NVIC 9-97.
Condition: Unknown
Due 19 October 2000
Resolved 23 October 2000
Engineering
Issued 3 August 2000 Resolved
PROVE PROPER OPERATION OF STERN THRUSTER
Condition: Unknown
Due 3 August 2000
Resolved 3 August 2000
Electrical
Issued 2 May 2000 Resolved
PROVE PROPER OPERATION OF NO. 1 SSDG AND REVERSE POWER RELAYS OF NO. AND NO. 2 SSDG'S.
Condition: Unknown
Due 2 May 2000
Resolved 2 May 2000
Accommodation/Occupational Safety
Issued 2 May 2000 Resolved
PROPERLY CLEAN UNDER AND AROUND ALL HOT CARTS ON FIRST DECK IN THE BOW AREA.
Condition: Unknown
Due 2 May 2000
Resolved 2 May 2000
Accommodation/Occupational Safety
Issued 2 May 2000 Resolved
PROPERLY CLEAN GALLEY DECK AND WALK IN COOLER.
Condition: Unknown
Due 2 May 2000
Resolved 2 May 2000
Accommodation/Occupational Safety
Issued 2 May 2000 Resolved
PROPERLY CLEAN SLOT OFFICE AND REMOVE EXCESS PAPER AND GARBAGE WHICH POSE_x001C_ A FIRE HAZARD.
Condition: Unknown
Due 2 May 2000
Resolved 2 May 2000
Construction/Loadline
Issued 2 May 2000 Resolved
PROVE PROPER OPERATION OF BILGE SYSTEM FROM VOIDS 6 AND 7 STARBOARD SIDE AND VOID 5 PORT SIDE.
Condition: Unknown
Due 2 May 2000
Resolved 2 May 2000
Accommodation/Occupational Safety
Issued 2 May 2000 Resolved
PROPERLY CLEAN 1ST AND 3RD DECK OVERHEAD A/C FILTERS AND SCREENS AS NEEDED.
Condition: Unknown
Due 2 May 2000
Resolved 2 May 2000
Accommodation/Occupational Safety
Issued 2 May 2000 Resolved
PROPERLY CLEAN AND SANITIZE ALL BARS.
Condition: Unknown
Due 2 May 2000
Resolved 2 May 2000
Accommodation/Occupational Safety
Issued 2 May 2000 Resolved
FIND SOURCE OF LEAK IN HARD COUNT ROOM, REPAIR LEAK AND PROPERLY REPAIR HOLES IN OVERHEAD OF HARD COUNT ROOM.
Condition: Unknown
Due 2 May 2000
Resolved 2 May 2000
Engineering
Issued 2 May 2000 Resolved
PROVE PROPER OPERATION OF BOW THRUSTER.
Condition: Unknown
Due 2 May 2000
Resolved 2 May 2000
Fire Fighting
Issued 2 May 2000 Resolved
PROVE PROPER SERVICING OF ALL HAND HELD FIRE EXTINGUISHERS.
Condition: Unknown
Due 2 May 2000
Resolved 2 May 2000
Electrical
Issued 2 May 2000 Resolved
PROVE PROPER OPERATION OF EDG OVERSPEED.
Condition: Unknown
Due 2 May 2000
Resolved 2 May 2000
Electrical
Issued 9 February 2000 Resolved
INSTALL EMERGENCY LIGHTING STBD SIDE OF GALLEY.
Condition: Unknown
Due 9 February 2000
Resolved 9 February 2000
Fire Fighting
Issued 9 February 2000 Resolved
ENSURE PROPER OPERATION OF FIRE DOORS 3 AND 5.
Condition: Unknown
Due 9 February 2000
Resolved 9 February 2000
Electrical
Issued 9 February 2000 Resolved
PROPERLY MOUNT OUTLET BOX, REPLACE ALL PLASTIC WIRE TIES, AND INSTALL APPROVED WIRE RUNS. SECURE ALL NEW WIRES IN NEW WIRE RUNS.
Condition: Unknown
Due 9 February 2000
Resolved 9 February 2000
Fire Fighting
Issued 9 November 1999 Resolved
ENSURE PROPER OPERATION OF FSD #2, 3, AND 8.
Condition: Unknown
Due 9 November 1999
Resolved 9 November 1999
Electrical
Issued 9 November 1999 Resolved
PROPERLY SECURE DEADEND WIRES, REMOVE EXTENSION CORD, AND FIRE STOP HOLE INBLKHD, OUTSIDE SECOND DECK FWD CAGE OVERHEAD STBD SIDE.
Condition: Unknown
Due 9 November 1999
Resolved 9 November 1999
Engineering
Issued 9 November 1999 Resolved
CONDUCT TEST ON BOTH ELECTRIC BOILER SAFETY DEVICES AND HYDRO TO 1.25 MAWP.
Condition: Unknown
Due 9 November 1999
Resolved 9 November 1999
Electrical
Issued 9 November 1999 Resolved
PROPERLY SECURE AC WIRE IN FIRST DECK OVERHEAD ABOVE RED, WHITE, AND BLUE SLOT MACHINE.
Condition: Unknown
Due 9 November 1999
Resolved 9 November 1999
Engineering
Issued 9 November 1999 Resolved
TEST ALL GENERATORS, BOW THRUSTER, PRIME MOVERS, AND MAIN ENGINE ALARMS ANDSHUTDOWNS.
Condition: Unknown
Due 9 November 1999
Resolved 9 November 1999
Construction/Loadline
Issued 9 November 1999 Resolved
INSTALL FIRE STOP (ELECTRICAL WIRES) IN DECK UNDER GAMING TABLES IN PIT #5.
Condition: Unknown
Due 9 November 1999
Resolved 9 November 1999
Electrical
Issued 9 November 1999 Resolved
PROPERLY SECURE 220 VOLT POWER CORD, ON DECK, FOR FIRST DECK HOT DOG CART.
Condition: Unknown
Due 9 November 1999
Resolved 9 November 1999
Accommodation/Occupational Safety
Issued 9 November 1999 Resolved
PROPERLY CLEAN, PICK-UP, AND STOW LOOSE GEAR IN HARD COUNT ROOM.
Condition: Unknown
Due 9 November 1999
Resolved 9 November 1999
Electrical
Issued 9 November 1999 Resolved
INSTALL E-LIGHTS IN PUMP ROOM SPACE.
Condition: Unknown
Due 9 November 1999
Resolved 9 November 1999
Electrical
Issued 10 August 1999 Resolved
PROVE PROPER OPERATION OF #2 SSG REVERSE POWER RELAY.
Condition: Unknown
Due 10 August 1999
Resolved 10 August 1999
Fire Fighting
Issued 10 August 1999 Resolved
INSPECT AND REPAIR AS NECESSARY ALL EXTERIOR AND FSD'S TO ENSURE PROPER CLOSURE. (LATCHING)
Condition: Unknown
Due 10 August 1999
Resolved 10 August 1999
Fire Fighting
Issued 10 August 1999 Resolved
MOUNT DIRECTIONS FOR PROPER ACTIVATION OF E/R FIXED FIRE FIGHTING SYSTEM ATPULL STATION.
Condition: Unknown
Due 10 August 1999
Resolved 10 August 1999
Electrical
Issued 10 August 1999 Resolved
REPAIR OR REMOVE ELECTRICAL OUTLET BOXES ON 2ND DECK AFT OF SLOTS FORWARD OF PARTITION BULKHEAD.
Condition: Unknown
Due 10 August 1999
Resolved 10 August 1999
Accommodation/Occupational Safety
Issued 10 August 1999 Resolved
REPAIR DECK DRAIN UNDER ICE MACHINE IN PANTRY. CONDENSATION WAS DRAINING ONON DECK AND NOT INTO DRAIN.
Condition: Unknown
Due 10 August 1999
Resolved 10 August 1999
Electrical
Issued 10 August 1999 Resolved
REPAIR ELECTRICAL OUTLET ON ELEVATOR HOUSING IN GALLEY.
Condition: Unknown
Due 10 August 1999
Resolved 10 August 1999
Accommodation/Occupational Safety
Issued 10 August 1999 Resolved
THROUGHLY CLEAN UNDER ALL COUNTERS AND CABINETS IN PANTRY.
Condition: Unknown
Due 10 August 1999
Resolved 10 August 1999
Lifesaving
Issued 10 August 1999 Resolved
PROVE PROPER OPERATION OF FORWARD RESCUE BOAT. UNABLE TO OPERATE RESCUE BOAT, DUE TO DAVIT WINCH MOTOR FAILURE.
Condition: Unknown
Due 10 August 1999
Resolved 10 August 1999
Accommodation/Occupational Safety
Issued 10 August 1999 Resolved
REPAIR DRAINAGE SYSTEM IN AIR HANDLER SPACE #4. CONDENSATION RUN OFF IS NOTDRAINING PROPERLY.
Condition: Unknown
Due 10 August 1999
Resolved 10 August 1999
Electrical
Issued 16 February 1999 Resolved
properly secure all wires, on the deck, in the data room.
Condition: Unknown
Due 16 February 1999
Resolved 16 February 1999
Fire Fighting
Issued 16 February 1999 Resolved
Service or replace both small boat fire extinguishers.
Condition: Unknown
Due 16 February 1999
Resolved 16 February 1999
Electrical
Issued 16 February 1999 Resolved
Properly wire and plug hole in wall behind new ATM, 3rd deck, stbd side, fwd.
Condition: Unknown
Due 16 February 1999
Resolved 16 February 1999
Electrical
Issued 16 February 1999 Resolved
Install covers on all exposed outlets, aft wall, 3rd deck cage.
Condition: Unknown
Due 16 February 1999
Resolved 16 February 1999
Electrical
Issued 16 February 1999 Resolved
Properly secure 220 volt outlet box, on the deck of the snack bar area.
Condition: Unknown
Due 16 February 1999
Resolved 16 February 1999
Accommodation/Occupational Safety
Issued 16 February 1999 Resolved
Properly clean all bars.
Condition: Unknown
Due 16 February 1999
Resolved 16 February 1999
Accommodation/Occupational Safety
Issued 16 February 1999 Resolved
Properly clean all return air vents on the 3rd deck.
Condition: Unknown
Due 16 February 1999
Resolved 16 February 1999
Lifesaving
Issued 4 November 1998 Resolved
REPLACE MISSING EMERGENCY EYEWASH IN GALLEY.
Condition: Unknown
Due 4 November 1998
Resolved 4 November 1998
Accommodation/Occupational Safety
Issued 4 November 1998 Resolved
REMOVE OR PROPERLY INSTALL SPACE HEATERS IN #1 VOID/BOS'N HOLE.
Condition: Unknown
Due 4 November 1998
Resolved 4 November 1998
Accommodation/Occupational Safety
Issued 4 November 1998 Resolved
REPAIR DOOR HANDLE ON DOOR LEADING TO #1 VOID FROM MAIN DECK LOBBY FWD.
Condition: Unknown
Due 4 November 1998
Resolved 4 November 1998
Electrical
Issued 4 November 1998 Resolved
REPAIR OR REPLACE DEFECTIVE LIGHT FIXTURE ABOVE DISHWASHER ON PORT SIDE.
Condition: Unknown
Due 4 November 1998
Resolved 4 November 1998
Lifesaving
Issued 4 November 1998 Resolved
INSTALL RETROREFLECTIVE TAPE ON ALL RING BOUYS.
Condition: Unknown
Due 4 November 1998
Resolved 4 November 1998
Electrical
Issued 31 August 1998 Resolved
INSPECT ALL EXTERIOR NEON LIGHTING FOR IMPROPOPER INSTALLATION AT THROUGH HULL FITTINGS
Condition: Unknown
Due 6 October 1998
Resolved 6 October 1998
Construction/Loadline
Issued 31 August 1998 Resolved
INSTALL DOOR HANDLE ON 2ND DECK AFT, PORT SIDE, EXTERIOR DOOR
Condition: Unknown
Due 6 October 1998
Resolved 6 October 1998
Accommodation/Occupational Safety
Issued 31 August 1998 Resolved
REPAIR OIL LEAK IN FORWARD ELEVATOR PIT.
Condition: Unknown
Due 6 October 1998
Resolved 6 October 1998
Electrical
Issued 31 August 1998 Resolved
INSPTALL COVER ON MAIN DECK (POWER UNIT) FWD STBD SIDE FREEZER COMPRESSOR SWITCH.
Condition: Unknown
Due 6 October 1998
Resolved 6 October 1998
Fire Fighting
Issued 31 August 1998 Resolved
INSPECT ALL GAMING SPACE EMERGENCY EXIT DOORS FOR PROPER GAP BETWEEN DOORS.WEATHERSTRIP ATTACHED TO OUTSIDE OF DOORS DETERIORATED.
Condition: Unknown
Due 6 October 1998
Resolved 6 October 1998
Accommodation/Occupational Safety
Issued 31 August 1998 Resolved
PROPERLY CLEAN 4TH DECK BAR _x001C_ _x001C_ _x001C_ x
Condition: Unknown
Due 6 October 1998
Resolved 6 October 1998
Lifesaving
Issued 31 August 1998 Resolved
PROPERLY MARK RINGBUOY LOCATIONS AS PER 46CFR199
Condition: Unknown
Due 6 October 1998
Resolved 6 October 1998
Accommodation/Occupational Safety
Issued 31 August 1998 Resolved
PROPERLY CLEAN DEEP FAT FRYER, DISHWASHER, GRILL, AND GALLEY DECK.
Condition: Unknown
Due 6 October 1998
Resolved 6 October 1998
Electrical
Issued 31 August 1998 Resolved
PROPER SECURE WIRING IN OVERHEADS THROUGHOUT ALL DECKS
Condition: Unknown
Due 6 October 1998
Resolved 6 October 1998
Fire Fighting
Issued 31 August 1998 Resolved
INSTALL FIRESTOP IN DECK PENETRATION IN DATAROOM.
Condition: Unknown
Due 6 October 1998
Resolved 6 October 1998
Electrical
Issued 31 August 1998 Resolved
REPAIR HOLE IN EDG EXHAUST SYSTEM PIPING.
Condition: Unknown
Due 6 October 1998
Resolved 6 October 1998
Accommodation/Occupational Safety
Issued 31 August 1998 Resolved
INSPECT AND CLEAN BOTH ELEVATOR PITS
Condition: Unknown
Due 6 October 1998
Resolved 6 October 1998
Accommodation/Occupational Safety
Issued 31 August 1998 Resolved
INSPECT ALL AIR HANDLER SPACES FOR CLOGGED CONDENSATE DRAIN PIPING AND CLEAN MOLDED AND WET DECKS AS REQUIRED.
Condition: Unknown
Due 6 October 1998
Resolved 6 October 1998
Electrical
Issued 13 May 1998 Resolved
Prove proper operation of stbd searchlight.
Condition: Unknown
Due 22 June 1998
Resolved 22 June 1998
Engineering
Issued 13 May 1998 Resolved
Prove proper operation of center engine oil pressure and water temp gauges from the Bridge. _x001C_ _x001C_
Condition: Unknown
Due 22 June 1998
Resolved 22 June 1998
Electrical
Issued 13 May 1998 Resolved
Prove proper operation of #3 Gensets reverse power relay.
Condition: Unknown
Due 22 June 1998
Resolved 22 June 1998
Electrical
Issued 13 May 1998 Resolved
Update electrical panal L17 circuit directory card (engine room).
Condition: Unknown
Due 22 June 1998
Resolved 22 June 1998
Engineering
Issued 13 May 1998 Resolved
Replace glass filter bowl on stern/bow thruster hydro oil filter.
Condition: Unknown
Due 22 June 1998
Resolved 22 June 1998
Fire Fighting
Issued 13 May 1998 Resolved
Install firestop in stuffing tube, ovhd of void #8 portside.
Condition: Unknown
Due 22 June 1998
Resolved 22 June 1998
Electrical
Issued 13 May 1998 Resolved
Update elctrical panals circuit directory cards in 2nd deck electrical room(old desert bar)
Condition: Unknown
Due 22 June 1998
Resolved 22 June 1998
Lifesaving
Issued 13 May 1998 Resolved
Install proper line on life ring on 1st deck, fwd.
Condition: Unknown
Due 22 June 1998
Resolved 22 June 1998
Fire Fighting
Issued 13 May 1998 Resolved
Replace or repair wyegate on firestation #3.
Condition: Unknown
Due 29 May 1998
Resolved 29 May 1998
Accommodation/Occupational Safety
Issued 13 May 1998 Resolved
Repair leak, 2nd deck bar (center) portside.
Condition: Unknown
Due 22 June 1998
Resolved 22 June 1998
Electrical
Issued 13 May 1998 Resolved
Repair all exterior outlet box covers.
Condition: Unknown
Due 22 June 1998
Resolved 22 June 1998
Fire Fighting
Issued 13 May 1998 Resolved
Install fire stop 3rd deck, stbd side life jacket locker IWO Keno Corner.
Condition: Unknown
Due 22 June 1998
Resolved 22 June 1998
Fire Fighting
Issued 13 May 1998 Resolved
Install firestop under tables(all) pit #3 and properly secure wires and power box in same.
Condition: Unknown
Due 22 June 1998
Resolved 22 June 1998
Navigation
Issued 13 May 1998 Resolved
Prove proper operation of stern lights (navigation) on E-Power.
Condition: Unknown
Due 22 June 1998
Resolved 22 June 1998
Electrical
Issued 26 February 1998 Resolved
Properly secure wiring under bridge console.
Condition: Unknown
Due 26 February 1998
Resolved 26 February 1998
Electrical
Issued 26 February 1998 Resolved
Properly secure wiring behind forward ATM machine on first deck.
Condition: Unknown
Due 26 February 1998
Resolved 26 February 1998
Accommodation/Occupational Safety
Issued 26 February 1998 Resolved
Properly clean decks in 1st deck bars.
Condition: Unknown
Due 26 February 1998
Resolved 26 February 1998
Fire Fighting
Issued 26 February 1998 Resolved
Properly adjust fire screen doors #8, 7 and 2.
Condition: Unknown
Due 26 February 1998
Resolved 26 February 1998
Accommodation/Occupational Safety
Issued 26 February 1998 Resolved
properly label all air handler rooms.
Condition: Unknown
Due 26 February 1998
Resolved 26 February 1998
Accommodation/Occupational Safety
Issued 26 February 1998 Resolved
Clean all coin wrappers from behind slot machines on 2nd deck fwd and 3rd deck port amidships by keno machines (blkhd).
Condition: Unknown
Due 26 February 1998
Resolved 26 February 1998
Electrical
Issued 26 February 1998 Resolved
Remove dead end wires and clean music room.
Condition: Unknown
Due 26 February 1998
Resolved 26 February 1998
Electrical
Issued 26 February 1998 Resolved
Remove dead end wire in air handler room.
Condition: Unknown
Due 26 February 1998
Resolved 26 February 1998
Accommodation/Occupational Safety
Issued 26 February 1998 Resolved
Install MSDS in 3rd deck womans bathroom.
Condition: Unknown
Due 26 February 1998
Resolved 26 February 1998
Engineering
Issued 26 February 1998 Resolved
Replace guage on stern thruster (bridge).
Condition: Unknown
Due 26 February 1998
Resolved 26 February 1998
Navigation
Issued 26 February 1998 Resolved
Replace guages on steering pumps.
Condition: Unknown
Due 26 February 1998
Resolved 26 February 1998
Navigation
Issued 26 February 1998 Resolved
Properly wire telephone in passenger elevator.
Condition: Unknown
Due 26 February 1998
Resolved 26 February 1998
Electrical
Issued 26 February 1998 Resolved
Properly wire speaker, stbd side fantail. (Wires are in aft steering).
Condition: Unknown
Due 26 February 1998
Resolved 26 February 1998
Construction/Loadline
Issued 26 February 1998 Resolved
Install proper size fire stop in stuffing box #9, inboard port side, aft bulkhead.
Condition: Unknown
Due 26 February 1998
Resolved 26 February 1998
Electrical
Issued 26 February 1998 Resolved
Secure surveilance wire with metal wire ties in void #8.
Condition: Unknown
Due 26 February 1998
Resolved 26 February 1998
Construction/Loadline
Issued 26 February 1998 Resolved
Install proper size fire stop in stuffing box, void #4, outboard port, aft bulkhead.
Condition: Unknown
Due 26 February 1998
Resolved 26 February 1998
Construction/Loadline
Issued 26 February 1998 Resolved
Install fire stop in overhead stuffing tube , void #2.
Condition: Unknown
Due 26 February 1998
Resolved 26 February 1998
Construction/Loadline
Issued 26 February 1998 Resolved
Install proper size fire stop in stuffing box, void #1, inboard port.
Condition: Unknown
Due 26 February 1998
Resolved 26 February 1998
Accommodation/Occupational Safety
Issued 26 February 1998 Resolved
Clean hydraulic oil and indentify source of leak in passenger elevator shaft.
Condition: Unknown
Due 26 February 1998
Resolved 26 February 1998
Deck/Cargo
Issued 26 February 1998 Resolved
Replace or repair tachometer sending unit on stern thruster.
Condition: Unknown
Due 26 February 1998
Resolved 26 February 1998
Accommodation/Occupational Safety
Issued 26 January 1998 Resolved
Make permanent repairs to the galley area where deep fat fryer fire occured.
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Accommodation/Occupational Safety
Issued 3 December 1997 Resolved
Properly clean all ventilation ducts in all mens & women heads.
Condition: Unknown
Due 3 December 1997
Resolved 3 December 1997
Electrical
Issued 3 December 1997 Resolved
Prove proper operation of emergency generator ameter (local).
Condition: Unknown
Due 3 December 1997
Resolved 3 December 1997
Lifesaving
Issued 3 December 1997 Resolved
Charge SCBA air bottle and prove proper operation (missing waist belt and alarm bell).
Condition: Unknown
Due 3 December 1997
Resolved 3 December 1997
Fire Fighting
Issued 3 December 1997 Resolved
Properly adjust FD #3.
Condition: Unknown
Due 3 December 1997
Resolved 3 December 1997
Accommodation/Occupational Safety
Issued 3 December 1997 Resolved
Remove all plastic trash cans from vessel.
Condition: Unknown
Due 3 December 1997
Resolved 3 December 1997
Electrical
Issued 3 December 1997 Resolved
Install stuffing tubes on shore tie box IWO 2nd deck ramps.
Condition: Unknown
Due 3 December 1997
Resolved 3 December 1997
Accommodation/Occupational Safety
Issued 3 December 1997 Resolved
Properly clean wall, overhead and exhaust fan in 2nd deck amidship stbd airhandler room.
Condition: Unknown
Due 3 December 1997
Resolved 3 December 1997
Electrical
Issued 3 December 1997 Resolved
Repair or replace 2nd deck video poker sign and wiring.
Condition: Unknown
Due 3 December 1997
Resolved 3 December 1997
Electrical
Issued 25 August 1997 Resolved
Install proper outlet cover forward cage 2nd deck.
Condition: Unknown
Due 25 September 1997
Resolved 2 October 1997
Electrical
Issued 25 August 1997 Resolved
Remove temporary fans (door installation and floor fan) from audio space.
Condition: Unknown
Due 25 September 1997
Resolved 2 October 1997
Electrical
Issued 25 August 1997 Resolved
Remove plastic wire ties from vent spaces on all decks.
Condition: Unknown
Due 25 September 1997
Resolved 2 October 1997
Electrical
Issued 25 August 1997 Resolved
Remove unused wires from vent space on all decks.
Condition: Unknown
Due 25 September 1997
Resolved 2 October 1997
Electrical
Issued 25 August 1997 Resolved
Properly install 4 outlet receptacle with 2 outlet receptacle 2nd deck stbdvent space.
Condition: Unknown
Due 25 September 1997
Resolved 2 October 1997
Electrical
Issued 25 August 1997 Resolved
Properly install wiring in surveillance space behind monitors.
Condition: Unknown
Due 25 September 1997
Resolved 2 October 1997
Accommodation/Occupational Safety
Issued 25 August 1997 Resolved
Repair, remove, or replace floor coverings IWO 4th deck bar and aft p/s steps.
Condition: Unknown
Due 25 August 1997
Resolved 25 August 1997
Electrical
Issued 25 August 1997 Resolved
Replace wire rope on 2nd deck passenger ramps.
Condition: Unknown
Due 25 September 1997
Resolved 2 October 1997
Engineering
Issued 25 August 1997 Resolved
Inspect all MDE/SSG RACOR filter bowls and replace cracked ones.
Condition: Unknown
Due 25 September 1997
Resolved 2 October 1997
Construction/Loadline
Issued 25 August 1997 Resolved
Adjust all WTD's for proper closure.
Condition: Unknown
Due 25 September 1997
Resolved 2 October 1997
Electrical
Issued 25 August 1997 Resolved
Repair or replace 4th deck aft speaker.
Condition: Unknown
Due 25 September 1997
Resolved 2 October 1997
Electrical
Issued 25 August 1997 Resolved
Remove "E" lighting (4th deck) from dimmer switch.
Condition: Unknown
Due 25 September 1997
Resolved 2 October 1997
Accommodation/Occupational Safety
Issued 25 August 1997 Resolved
Clean deck in liquor locker.
Condition: Unknown
Due 25 September 1997
Resolved 2 October 1997
Accommodation/Occupational Safety
Issued 25 August 1997 Resolved
Clean deck in soda locker.
Condition: Unknown
Due 25 September 1997
Resolved 2 October 1997
Lifesaving
Issued 25 August 1997 Resolved
Clean and properly stow paper products in hard count room.
Condition: Unknown
Due 25 September 1997
Resolved 2 October 1997
Electrical
Issued 25 August 1997 Resolved
Remove portable surge protectors from brig and EMT room.
Condition: Unknown
Due 25 September 1997
Resolved 2 October 1997
Accommodation/Occupational Safety
Issued 25 August 1997 Resolved
Provide MSDS for cleaning gear stowed in all heads.
Condition: Unknown
Due 25 September 1997
Resolved 2 October 1997
Electrical
Issued 25 August 1997 Resolved
Repair or replace light guards in service elevator on power module.
Condition: Unknown
Due 25 September 1997
Resolved 2 October 1997
Fire Fighting
Issued 25 August 1997 Resolved
Properly adjust FSD 6.
Condition: Unknown
Due 25 September 1997
Resolved 2 October 1997
Engineering
Issued 25 August 1997 Resolved
Properly install pipe hanger in hard count room overhead.
Condition: Unknown
Due 25 September 1997
Resolved 2 October 1997
Electrical
Issued 25 August 1997 Resolved
Properly install wires in audio space.
Condition: Unknown
Due 25 September 1997
Resolved 2 October 1997
Fire Fighting
Issued 25 August 1997 Resolved
Properly install A-O conduit around liquor lines in 2nd deck aft vent spaceport side.
Condition: Unknown
Due 25 September 1997
Resolved 2 October 1997
Electrical
Issued 25 August 1997 Resolved
Properly install outlet cover next to the restaurant cash register.
Condition: Unknown
Due 25 September 1997
Resolved 2 October 1997
Accommodation/Occupational Safety
Issued 25 August 1997 Resolved
Replace door hinges on maindeck, stbd side fwd doors.
Condition: Unknown
Due 25 September 1997
Resolved 2 October 1997
Fire Fighting
Issued 25 August 1997 Resolved
Replace over charged fire extinguisher in 1st deck cashier cage foward.
Condition: Unknown
Due 25 September 1997
Resolved 2 October 1997
Engineering
Issued 25 August 1997 Resolved
Install heat shield around #3 gen. exhaust stack.
Condition: Unknown
Due 25 September 1997
Resolved 2 October 1997
Construction/Loadline
Issued 25 May 1997 Resolved
Check all bulkhead wire penetrations leading to weather decks.
Condition: Unknown
Due 9 June 1997
Resolved 9 June 1997
Lifesaving
Issued 25 May 1997 Resolved
Properly attach all lights to life ring with a detachable clip._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 June 1997
Resolved 9 June 1997
Fire Fighting
Issued 25 May 1997 Resolved
Remove locking devices from all main space and main vertical zone FSD egress doors.
Condition: Unknown
Due 25 May 1997
Resolved 25 May 1997
Electrical
Issued 25 May 1997 Resolved
Remove electric extension cords from all bars and cashier cages._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 June 1997
Resolved 9 June 1997
Lifesaving
Issued 25 May 1997 Resolved
Properly secure carpet securing strip on 3rd deck crew elevator door.
Condition: Unknown
Due 5 June 1997
Resolved 9 June 1997
Construction/Loadline
Issued 25 May 1997 Resolved
Repair cracked welds on stantions on 2nd deck ramp.
Condition: Unknown
Due 9 June 1997
Resolved 9 June 1997
Construction/Loadline
Issued 25 May 1997 Resolved
Repair cracked welds on stantions on 1st deck stage._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 June 1997
Resolved 9 June 1997
Electrical
Issued 25 May 1997 Resolved
Properly label electric box and breakers in 2nd deck aft casino electric closet.
Condition: Unknown
Due 9 June 1997
Resolved 9 June 1997
Fire Fighting
Issued 25 May 1997 Resolved
install ceiling tiles in 2nd deck galley.
Condition: Unknown
Due 9 June 1997
Resolved 9 June 1997
Documentation
Issued 25 May 1997 Resolved
Update all fire control plans to reflect permenatly secured door in soft count room.
Condition: Unknown
Due 9 June 1997
Resolved 9 June 1997
Electrical
Issued 25 May 1997 Resolved
Properly mark all exterior emergency lights with red "E".
Condition: Unknown
Due 9 June 1997
Resolved 9 June 1997
Electrical
Issued 25 May 1997 Resolved
Properly secure wiring from damaged neon lights on second deck port.
Condition: Unknown
Due 9 June 1997
Resolved 9 June 1997
Electrical
Issued 25 May 1997 Resolved
Properly secure wire in 4th deck port life jacket locker._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 June 1997
Resolved 9 June 1997
Electrical
Issued 25 May 1997 Resolved
Properly label breakers in panel BH1.
Condition: Unknown
Due 9 June 1997
Resolved 9 June 1997
Construction/Loadline
Issued 25 May 1997 Resolved
Ensure main deck plating holes are sealed up.
Condition: Unknown
Due 9 June 1997
Resolved 9 June 1997
Engineering
Issued 25 May 1997 Resolved
Repair exhaust vent, 2nd deck, port side, aft power unit.
Condition: Unknown
Due 9 June 1997
Resolved 9 June 1997
Engineering
Issued 25 May 1997 Resolved
Replace gaskets on #3 SSG exhaust piping on expansion pipe.
Condition: Unknown
Due 9 June 1997
Resolved 9 June 1997
Fire Fighting
Issued 25 May 1997 Resolved
Properly mount smoke detector in Data room_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 June 1997
Resolved 9 June 1997
Fire Fighting
Issued 25 May 1997 Resolved
Install ceiling tiles in Data room.
Condition: Unknown
Due 5 June 1997
Resolved 9 June 1997
Documentation
Issued 27 February 1997 Resolved
Update fire control plan to reflect layout changes on the 2nd deck.
Condition: Unknown
Due 27 February 1997
Resolved 27 February 1997
Electrical
Issued 27 February 1997 Resolved
ENSURE ALL "E" LTS ARE PROPERLY LABELED W/RED 1/2" "E's".
Condition: Unknown
Due 27 February 1997
Resolved 27 February 1997
Fire Fighting
Issued 27 February 1997 Resolved
Properly outfit fire station #25. Missing a spanner wrench and approved fire hose.
Condition: Unknown
Due 27 February 1997
Resolved 27 February 1997
Fire Fighting
Issued 27 February 1997 Resolved
Ensure bulkhead penetration (telephone cord) in 2nd deck, stbd side fwd, meets A-60 SFP standards as per 46CFR72.
Condition: Unknown
Due 27 February 1997
Resolved 27 February 1997
Fire Fighting
Issued 27 February 1997 Resolved
Ensure stbd side bowthruster stairwell bulkhead (behind cash machine) penetration meets requirements of 46CFR72 (A-60 SFP)
Condition: Unknown
Due 27 February 1997
Resolved 27 February 1997
Fire Fighting
Issued 27 February 1997 Resolved
Ensure clearance between doors on fire screen door #8 does not exceed 1/8 inch
Condition: Unknown
Due 27 February 1997
Resolved 27 February 1997
Electrical
Issued 27 February 1997 Resolved
INSTALL BOLTS ON #1 SSG, FRONT GUARD, GOVERNOR SIDE.
Condition: Unknown
Due 27 February 1997
Resolved 27 February 1997
Fire Fighting
Issued 27 February 1997 Resolved
REPAIR LEAK ON 2ND DECK FIRE STATION #9 PIPING, AND PROVE PROPER MATERIALS AS REQUIRED BY 46CFR56._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 February 1997
Resolved 27 February 1997
Electrical
Issued 27 February 1997 Resolved
Repair L/O leak on #1 SSG governor L/O line. Leak is on the aft end of the actuator where the oil line connects to the Governor.
Condition: Unknown
Due 27 February 1997
Resolved 27 February 1997
Accommodation/Occupational Safety
Issued 18 December 1996 Resolved
Clean up oily fluid on deck is air handler space, first deck, aft, port
Condition: Unknown
Due 18 December 1996
Resolved 18 December 1996
Electrical
Issued 18 December 1996 Resolved
Recalculate fireload in surveillence space due to excessive amounts of coiled wire.
Condition: Unknown
Due 18 December 1996
Resolved 18 December 1996
Electrical
Issued 18 December 1996 Resolved
Prove proper operation of #1 SSG reverse power relay_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 December 1996
Resolved 18 December 1996
Accommodation/Occupational Safety
Issued 18 December 1996 Resolved
Improve cleanliness of the galley: clean under all appliances. Deck noted to be very dirty.
Condition: Unknown
Due 18 December 1996
Resolved 18 December 1996
Accommodation/Occupational Safety
Issued 18 December 1996 Resolved
Make available for inspection all ventilation ducts._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 December 1996
Resolved 18 December 1996
Electrical
Issued 18 December 1996 Resolved
Remove decorative neon lights from e-circuit
Condition: Unknown
Due 18 December 1996
Resolved 18 December 1996
Lifesaving
Issued 18 December 1996 Resolved
Verify life jacket count in all life jacket lockers throughout vessel.
Condition: Unknown
Due 18 December 1996
Resolved 18 December 1996
Electrical
Issued 18 December 1996 Resolved
Label and properly cover rescue boat embarkation light switch, Main deck, port side.
Condition: Unknown
Due 18 December 1996
Resolved 18 December 1996
Lifesaving
Issued 28 August 1996 Resolved
REPLACE DECAYED LINE ON WATERLIGHTS IWO LIFERINGS ON PORT AND STBD BRIDGE WINGS.
Condition: Unknown
Due 28 August 1996
Resolved 28 August 1996
Documentation
Issued 28 August 1996 Resolved
PROVIDE VALID COFR
Condition: Unknown
Due 28 August 1996
Resolved 28 August 1996
Electrical
Issued 28 August 1996 Resolved
REMOVE ALL TEMPORARY POWERSTRIPS AND EXTENSION CORDS FROM SURVEILLENCE ROOM, COMPUTER DATA ROOM AND IL GAMING BOARD OFFICE. POWER STRIPS IF INSTALLED MUST BE HARD WIRED.
Condition: Unknown
Due 28 August 1996
Resolved 28 August 1996
Electrical
Issued 28 August 1996 Resolved
REMOVE FANS FROM FOURTH DECK LOUNGE AREA OR PROVE FANS ARE UL LISTED FOR OUTDOOR USE.
Condition: Unknown
Due 28 August 1996
Resolved 28 August 1996
Electrical
Issued 28 August 1996 Resolved
Tighten (adjust) #2 and #3 SSGs mount springs.
Condition: Unknown
Due 11 October 1996
Resolved 13 September 1996
Construction/Loadline
Issued 28 August 1996 Resolved
Install dogging bolts in four (4) scuttles in after steering, ensure they are properly secured.
Condition: Unknown
Due 11 October 1996
Resolved 13 September 1996
Construction/Loadline
Issued 28 August 1996 Resolved
VEE OUT AND WELD BOTH SIDES OF REPAIRED DECK ABOVE BOW THRUSTER TUBE VOID, PORT SIDE.
Condition: Unknown
Due 28 August 1996
Resolved 28 August 1996
Electrical
Issued 28 August 1996 Resolved
Label F/O purifier disconnect.
Condition: Unknown
Due 11 October 1996
Resolved 13 September 1996
Electrical
Issued 28 August 1996 Resolved
install light fixture globe on light in e/r storeroom_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 August 1996
Resolved 28 August 1996
Accommodation/Occupational Safety
Issued 28 August 1996 Resolved
PROVE PROPER OPERATION OF WALK-IN REEFER BOX RELEASE.
Condition: Unknown
Due 28 August 1996
Resolved 28 August 1996
Electrical
Issued 28 August 1996 Resolved
Properly lable breakers in engineroom auxillary accessory panal.
Condition: Unknown
Due 11 October 1996
Resolved 13 September 1996
Electrical
Issued 28 August 1996 Resolved
PROPERLY LABEL AHP BREAKERS IN VOID #10.
Condition: Unknown
Due 28 August 1996
Resolved 28 August 1996
Electrical
Issued 28 August 1996 Resolved
Lable sewage pump controller and sewage pump disconnect.
Condition: Unknown
Due 11 October 1996
Resolved 13 September 1996
Fire Fighting
Issued 28 August 1996 Resolved
REPAIR PIPE BRACKET ON FIRE MAIN PIPE IN HARD COUNT.
Condition: Unknown
Due 28 August 1996
Resolved 28 August 1996
Electrical
Issued 28 August 1996 Resolved
Install globe and cage on light fixture between Chillers (AC units).
Condition: Unknown
Due 28 August 1996
Resolved 28 August 1996
Engineering
Issued 28 August 1996 Resolved
PROPERLY LABEL BOW THRUSTER ROOM VENT, PORT SIDE.
Condition: Unknown
Due 28 August 1996
Resolved 28 August 1996
Lifesaving
Issued 28 August 1996 Resolved
REMOVE PLASTIC TRASH CANS FROM ALL PUBLIC SPACES (TABLE GAMES) OR PROVE EXISTING TRASHCANS ARE NONCOMBUSTIBLE._x001C_
Condition: Unknown
Due 28 August 1996
Resolved 28 August 1996
Accommodation/Occupational Safety
Issued 28 August 1996 Resolved
ENSURE SANITARY CONDITIONS ARE MET AND MAINTAINED ON THE DECKS IN THE FOLLOWING SPACES; FIRST DECK FWD AND AFT BARS AND THE COFFEE ROOM IN THE SECOND DECK DINING ROOM.
Condition: Unknown
Due 28 August 1996
Resolved 28 August 1996
Electrical
Issued 28 August 1996 Resolved
REPAIR INBOARD HOTSTART JUNCTION BOX ON #3 SS GENERATOR
Condition: Unknown
Due 28 August 1996
Resolved 28 August 1996
Engineering
Issued 28 August 1996 Resolved
REPAIR NUMBEROUS HYDRAULIC LEAKS IWO STERNTHUSTER HYD PSI GAUGES AND HOSES.
Condition: Unknown
Due 28 August 1996
Resolved 28 August 1996
Fire Fighting
Issued 25 May 1996 Resolved
Connect each fire screen door holding and release system to the emergency power source as per 46CFR 122.15-1 (k).
Condition: Unknown
Due 28 June 1996
Resolved 28 June 1996
Electrical
Issued 25 May 1996 Resolved
Connect ememrgency loudspeaker system (PA) to the emergency power source, per 46CFR 112.15-1(g),(j).
Condition: Unknown
Due 28 June 1996
Resolved 28 June 1996
Electrical
Issued 25 May 1996 Resolved
Repair exit light IWO main deck FWD exit.
Condition: Unknown
Due 28 June 1996
Resolved 28 June 1996
Engineering
Issued 25 May 1996 Resolved
Replace volt guage for STBD engine IWO bridge console.
Condition: Unknown
Due 28 June 1996
Resolved 28 June 1996
Electrical
Issued 25 May 1996 Resolved
Label E-light IWO mens room 1st deck.
Condition: Unknown
Due 28 June 1996
Resolved 28 June 1996
Accommodation/Occupational Safety
Issued 29 February 1996 Resolved
INSTALL LATCH MECHANISM ON DOOR LEADING FROM MAIN DECK DOWN TO VOID #10.
Condition: Unknown
Due 30 March 1996
Resolved 29 February 1996
Engineering
Issued 29 February 1996 Resolved
PROPERLY SPECIFY STOWAGE LOCATION OF KEY IWO REMOTE FUEL SHUTOFFS AT BOW.
Condition: Unknown
Due 30 March 1996
Resolved 14 March 1996
Accommodation/Occupational Safety
Issued 29 February 1996 Resolved
SECURE BTM CORNER OF DOOR FACING IWO FIRE STATION #10.
Condition: Unknown
Due 30 March 1996
Resolved 29 February 1996
Fire Fighting
Issued 29 February 1996 Resolved
INSTALL CAP ON WYE GATE F/S VOID #8.
Condition: Unknown
Due 30 March 1996
Resolved 14 March 1996
Lifesaving
Issued 29 February 1996 Resolved
RENEW PFD INSTRUCTION PLACARD ON PORT STACK STORAGE LOCKER.
Condition: Unknown
Due 29 February 1996
Resolved 29 February 1996
Fire Fighting
Issued 29 February 1996 Resolved
PROPERLY LABEL (IE. ID) FIRE STATION #8.
Condition: Unknown
Due 30 March 1996
Resolved 29 February 1996
Electrical
Issued 16 January 1996 Resolved
PRIOR TO VESSEL GETTING UNDERWAY, PROVE PROPER OPERATION OF #1 SSG
Condition: Unknown
Due 19 January 1996
Resolved 19 January 1996
Fire Fighting
Issued 27 November 1995 Resolved
PROVIDE UL LISTED HOSE IWO FIRE STATIONS #24 & 25.
Condition: Unknown
Due 27 November 1995
Resolved 27 November 1995
Navigation
Issued 27 November 1995 Resolved
PROVIDE RULES OF THE ROAD.
Condition: Unknown
Due 27 November 1995
Resolved 28 November 1995
Deck/Cargo
Issued 27 November 1995 Resolved
SECURE BATTERY BOX IN BOW THRUSTER SPACE,
Condition: Unknown
Due 27 November 1995
Resolved 27 November 1995
Electrical
Issued 28 August 1995 Resolved
PLASTIC WIRE TIES USED THROUGHOUT THE BELOW DECK VOID SPACES.
Condition: Unknown
Due 12 October 1995
Resolved 12 October 1995
Electrical
Issued 28 August 1995 Resolved
PA SYSTEM WAS NOT FUNCTIONING PROPERLY THROUGHOUT THE VSL. THIS WAS CORRECTED BEFORE DEPARTURE.
Condition: Unknown
Due 28 August 1995
Resolved 29 August 1995
Electrical
Issued 25 May 1995 Resolved
PROPERLY LABEL ALL "E" LIGHTS (INTERIOR AND EXTERIOR).
Condition: Unknown
Due 10 June 1995
Resolved 26 May 1995
Fire Fighting
Issued 25 May 1995 Resolved
LABEL BOTH PORT AND STBD BOWTHRUSTER ROOM MANUAL VENT CLOSURES LOCATED ON THE MAIN DECK.
Condition: Unknown
Due 10 June 1995
Resolved 26 May 1995
Lifesaving
Issued 25 May 1995 Resolved
CONDUCT MAN OVERBOARD DRILL ONCE ST. LOUIS HARBOR HAS REOPENED FOR NAVIGATION.
Condition: Unknown
Due 25 May 1995
Resolved 25 May 1995
Lifesaving
Issued 3 March 1995 Resolved
PROVE TO THE SATISFACTION OF OCMI ST. LOUIS EXISTING RESCUE BOATS SUITABLE FOR THE ROUTE & SERVICE INTENDED OR PROVIDE SUCH RESCUE BOATS FOR INSPECTION BY THE OCMI. VESSEL ALLOWED TO OPERATE PROVIDED BOTH EXISTING RESCUE BOATS OPERATED SIMULTANEOUSLY UNTIL NEW BOATS INTSALLED.
Condition: Unknown
Due 3 March 1995
Resolved 3 March 1995
Fire Fighting
Issued 3 March 1995 Resolved
PROVE PROPER OPERATION OF THE FOLLOWING FIRE SCREEN DOORS: 14, 7, 8, 4, 5, AND 3 TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 3 March 1995
Resolved 3 March 1995
Fire Fighting
Issued 6 December 1994 Resolved
MAKE NECESSARY ADJUSTMENTS TO PORT SIDE, SECOND DECK, MIDSHIP FIRESCREEN DOORS TO ENSURE PROPER CLOSURE.
Condition: Unknown
Due 6 December 1994
Resolved 6 December 1994
Electrical
Issued 6 December 1994 Resolved
REPLACE EXISTING MERCURY VAPOR LIGHTING FOR RESCUE BOAT OPERATIONS WITH INCANDESCENT LIGHTING, PUT LIGHTS ON LOCAL CONTROLLED SWITCHES.
Condition: Unknown
Due 6 December 1994
Resolved 6 December 1994
Documentation
Issued 2 September 1994 Resolved
PROVIDE LISTING OF PERSONNEL QUALIFIED TO ACT AS PERSON IN CHARGE DURING FUEL TRANSFER OPERATIONS.
Condition: Unknown
Due 2 September 1994
Resolved 2 September 1994
Fire Fighting
Issued 2 September 1994 Resolved
PROVE PROPER OPERATION OF SMOKE DETECTOR IN THE CREW LOUNGE AREA LOCATED IN#1 VOID.
Condition: Unknown
Due 2 September 1994
Resolved 2 September 1994
Fire Fighting
Issued 2 September 1994 Resolved
TEST FIRE SCREEN DOOR #7, 2ND DECK, ,PORTSIDE, AFT.
Condition: Unknown
Due 2 September 1994
Resolved 2 September 1994
Lifesaving
Issued 2 September 1994 Resolved
INSTALL GUARD OVER BELTS FOR FWD BOW THRUSTER.
Condition: Unknown
Due 2 September 1994
Resolved 2 September 1994
Lifesaving
Issued 2 September 1994 Resolved
INSTALL "T" IN DRAIN LINE OF WHISTLE AIR RECEIVER OR REMOVE AIR HOSE QUICK CONNECT/DISCONNECT FITTING._x001C_
Condition: Unknown
Due 2 September 1994
Resolved 2 September 1994
Lifesaving
Issued 31 May 1994 Resolved
REPAIR INOP TELEPHONE IN PASSENGER ELEVATOR.
Condition: Unknown
Due 30 June 1994
Resolved 30 June 1994
Lifesaving
Issued 31 May 1994 Resolved
SUBMIT PASSENGER VESSEL CONTINGENCY PLAN (SLMMS INSP DEPT 01-94) TO SLMMS FOR APPROVAL.
Condition: Unknown
Due 30 June 1994
Resolved 30 June 1994
Electrical
Issued 31 May 1994 Resolved
REPLACE MISSING SWITCH COVER IN HARD COUNT ROOM.
Condition: Unknown
Due 30 June 1994
Resolved 30 June 1994
Lifesaving
Issued 31 May 1994 Resolved
CORRECT WIRE PENETRATION THROUGH A-60 DECK.
Condition: Unknown
Due 30 June 1994
Resolved 30 June 1994
Lifesaving
Issued 31 May 1994 Resolved
REPAIR IMPROPERLY OPERATING FIRE SCREEN DOOR.
Condition: Unknown
Due 30 June 1994
Resolved 30 June 1994
Electrical
Issued 16 March 1994 Resolved
CORRECT "JURY RIGGED" WIRING FOR TEMPORARY WIRING FOR SEWAGE TANK DISCHARGEPUMP.
Condition: Unknown
Due 30 March 1994
Resolved 30 June 1994
Fire Fighting
Issued 16 March 1994 Resolved
ENSURE ALL BULKHEAD PENETRATIONS IN HVAC SPACES HAVE PROPER AMOUNT AND TYPEOF STRUCTURAL FIRE PROTECTION INSULATION EXTENDING 12 INCHES OUT FROM THE INSULATED SIDE.
Condition: Unknown
Due 16 April 1994
Resolved 30 June 1994
Fire Fighting
Issued 16 March 1994 Resolved
ENSURE ALL STRUCTURAL FIRE PROTECTION INSULATION IN HVAC SPACES EXTENDS UP TO OVERHEAD.
Condition: Unknown
Due 16 April 1994
Resolved 30 June 1994
Lifesaving
Issued 16 March 1994 Resolved
REMOVE TEMPORARY LIGHTING CABLE FROM CANOPY OVERHEAD ON FOURTH (BRIDGE) DECK.
Condition: Unknown
Due 16 April 1994
Resolved 30 June 1994
Lifesaving
Issued 16 March 1994 Resolved
FIND SOURCE OF 24V DC ELECTRICAL CURRENT THAT SUPPLIES ELECTRICAL POWER TO ENGINE AND GENERATOR ALARM PANEL.
Condition: Unknown
Due 30 March 1994
Resolved 30 June 1994
Engineering
Issued 13 January 1994 Resolved
PROVIDE PROOF OF APPROVAL FOR BELLOWS IN BOW THRUSTER EXHAUST SYSTEM.
Condition: Unknown
Due 13 January 1994
Resolved 13 January 1994
Lifesaving
Issued 13 January 1994 Resolved
SUBMIT PLANS FOR INSTALLATION OF SECOND GENERAL ALARM CONTACT MAKER AT ALARM FEEDER SUPPLY PANEL, PLANS TO BE SUBMITTED TO OCMI ST LOUIS.
Condition: Unknown
Due 13 January 1994
Resolved 13 January 1994
Electrical
Issued 13 January 1994 Resolved
FOLLOW UP STATUS OF PATTI S/Y SUBMITTAL OF GENERAL ALARM SYSTEM WIRING DIAGRAM AS REQUESTED BY MSC LETTER E-30653, DATED 30NOV94.
Condition: Unknown
Due 13 January 1994
Resolved 13 January 1994
Electrical
Issued 13 January 1994 Resolved
FOLLOW UP STATUS OF PATTI S/Y SUBMITTAL OF REQUESTED INFORMATION ON EMERGENCY GENERATOR PROTECTION, INSTRUMENTATION, AND CONTROLS, AS REQUESTEDBY MSC LETTER E-30653, DATED 30NOV94.
Condition: Unknown
Due 13 January 1994
Resolved 13 January 1994
Electrical
Issued 13 January 1994 Resolved
CONDUCT PREVENTATIVE MAINTENANCE TO BATTERY SUPPLY FOR GENERAL ALARM SYSTEM
Condition: Unknown
Due 20 January 1994
Resolved 19 January 1994
Accommodation/Occupational Safety
Issued 27 September 1993 Resolved
ALL BELOW DECK LOCKED STORAGE AREAS TO BE ACCESSIBLE TO MEMBER OF VESSEL CREW, I.E., ENGINEER, CAPTAIN, MATE TO HAVE KEY IN CASE OF EMERGENCY.
Condition: Unknown
Due 27 September 1993
Resolved 27 September 1993
Fire Fighting
Issued 27 September 1993 Resolved
REPAIR SMOKE DETECTORS IN VOID SPACE #4 AND #3, TEST IN PRESENCE OF CG INSP
Condition: Unknown
Due 27 September 1993
Resolved 27 September 1993
Fire Fighting
Issued 27 September 1993 Resolved
CONTACT LOCAL OCMI TO WITNESS HYDROSTATIC TEST ON ALL NEWLY INSTALLED FIRE STATIONS BELOW MAIN DECK, TEST PRESSURE TO BE 150 PSI MINIMUM.
Condition: Unknown
Due 27 September 1993
Resolved 27 September 1993
Electrical
Issued 8 September 1993 Resolved
OPERATIONALLY TEST EMERGENCY GENERATOR IN PRESENCE OF CG MARINE INSPECTOR.
Condition: Unknown
Due 4 October 1993
Resolved 4 October 1993
Fire Fighting
Issued 8 September 1993 Resolved
OPERATIONALLY TEST FIRE PUMP/MAIN IN PRESENCE OF CG MARINE INSPECTOR.
Condition: Unknown
Due 4 October 1993
Resolved 4 October 1993
Fire Fighting
Issued 8 September 1993 Resolved
CONDUCT EMERGENCY DRILLS IN THE PRESENCE OF A CG MARINE INSPECTOR.
Condition: Unknown
Due 4 October 1993
Resolved 4 October 1993
Lifesaving
Issued 23 June 1993 Resolved
PROVIDE DEDICATED RADIO FREQUENCY FOR VESSEL'S SECURITY PERSONNEL.
Condition: Unknown
Due 23 June 1993
Resolved 29 June 1993
Lifesaving
Issued 23 June 1993 Resolved
REMOVE COMBUSTIBLE MATERIALS FROM ALL VOID SPACES NOT SERVED BY FIRE STATIONS LOCATED IN THAT RESPECTIVE SPACE.
Condition: Unknown
Due 23 June 1993
Resolved 29 June 1993
Lifesaving
Issued 23 June 1993 Resolved
INSTALL ON/OFF SWITCHES AT LOUDSPEAKERS IN PILOTHOUSE.
Condition: Unknown
Due 23 June 1993
Resolved 23 June 1993
Lifesaving
Issued 23 June 1993 Resolved
PROVIDE SKIDS FOR SAFELY LAUNCHING LIFERAFTS OVER THE SIDE.
Condition: Unknown
Due 23 June 1993
Resolved 23 June 1993
Fire Fighting
Issued 23 June 1993 Resolved
INSTALL DUPLEX STRAINER IN PLACE OF SINGLE STRAINER SYSTEM PRESENTLY INSTALLED AT BOTH FIRE PUMPS.
Condition: Unknown
Due 23 June 1993
Resolved 23 June 1993
Lifesaving
Issued 23 June 1993 Resolved
PROVIDE ADEQUATE ILLUMINATION FOR RESCUE BOAT RIGGING AND LAUNCHING OVER THE SIDE.
Condition: Unknown
Due 23 June 1993
Resolved 23 June 1993
Electrical
Issued 23 June 1993 Resolved
INSTALL PROTECTIVE GUARD/INSULATION AROUND EXPOSED PORTION OF EDG EXHAUST PIPE.
Condition: Unknown
Due 23 June 1993
Resolved 23 June 1993
Electrical
Issued 23 June 1993 Resolved
PROVIDE AN EFFECTIVE GLARE RESISTANT COVER FOR VISUAL ALARM PANELS IN PILOTHOUSE.
Condition: Unknown
Due 23 June 1993
Resolved 23 June 1993
Accommodation/Occupational Safety
Issued 23 June 1993 Resolved
INSTALL CHAIN BARRIERS WITH "CREW ONLY" SIGNS FOR PORT AND STBD SIDES OF PILOT HOUSE.
Condition: Unknown
Due 23 June 1993
Resolved 29 June 1993
Fire Fighting
Issued 23 June 1993 Resolved
REMOVE ALL HOLDBACKS ON WEATHERDECK DOORS IN SPACES SERVED BY FIXED HALON FIRE EXTINGUISHING SYSTEM.
Condition: Unknown
Due 23 June 1993
Resolved 29 June 1993
Lifesaving
Issued 23 June 1993 Resolved
INSTALL SWIVEL BLOCKS ON BOTH RESCUE BOATS DAVITS.
Condition: Unknown
Due 23 June 1993
Resolved 23 June 1993
Documentation
Issued 2 June 1993 Resolved
POST ORIGINAL COPY OF STABILITY LETTER UPON RECEIPT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 June 1993
Resolved 2 June 1993
Lifesaving
Issued 2 June 1993 Resolved
CONDUCT FIRE AND ABANDON SHIP DRILLS PRIOR TO THE CARRIAGE OF PASSENGERS FOR HIRE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 June 1993
Resolved 2 June 1993
Lifesaving
Issued 2 June 1993 Resolved
PROVIDE DETAILS FOR LAUNCHING FORWARD RESCUE BOAT PRIOR TO THE CARRIAGE OF PASSENGERS FOR HIRE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 June 1993
Resolved 2 June 1993

Source. US Coast Guard records through 23 August 2026, retrieved 5 September 2026. Vessels the Coast Guard classes as Barge or Towing Vessel. Coverage and known gaps.

Maury does not score, rate, or grade vessels. What Maury does not do · Glossary · Correct a record.