Records from 2001 to 2003. Most recent: operational control imposed, 29 December 2003.
Inspection history · 39
27 December 2003
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1970479
19 December 2003
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1967203
18 December 2003
Type not recorded
No type recorded · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 1966441
6 December 2003
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1959837
26 November 2003
Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 1955167
21 November 2003
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1952117
12 November 2003
Certificate of Compliance
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1947874
11 November 2003
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1945664
29 September 2002
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1683210
15 September 2002
MARPOL Annex I Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1675766
15 September 2002
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1676718
14 September 2002
Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 1676281
26 August 2002
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1668980
9 August 2002
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1658906
6 August 2002
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1658401
23 July 2002
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1650710
16 July 2002
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1648325
19 June 2002
Security Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1633492
18 June 2002
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1647337
11 June 2002
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1629244
30 May 2002
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1647163
29 May 2002
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1622703
21 May 2002
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1620246
20 May 2002
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1620236
20 May 2002
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1620242
19 May 2002
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1620586
19 May 2002
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1622640
13 May 2002
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1617407
3 May 2002
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1617335
30 April 2002
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1626353
12 April 2002
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1604153
11 April 2002
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1640135
25 February 2002
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1489184
23 February 2002
Security Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1488296
2 January 2002
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1482631
30 December 2001
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1477210
15 December 2001
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1477075
5 December 2001
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1476997
17 November 2001
Certificate of Compliance
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 295632
Lifesaving › Lifeboat
Issued 12 November 2003
Resolved
Renew wasted exhaust pipe on portside lifeboat; SOLAS 74Am/III/41.6.6 LEGACY COMPONENT DESC: Exhaust Pipe
Action required: 705 - Other - as specified
Due 22 November 2003
Resolved 22 November 2003
Resolution: Exhaust pipe renewed to satisfaction of class and verified by Coast Guard Marine Inspector.
Deck/Cargo
Issued 12 November 2003
Resolved
Adjust both motor-room air-lock doors to be reasonably gas tight in self-closing operation; Gas Code 3.6.2.
Action required: 705 - Other - as specified
Due 22 November 2003
Resolved 22 November 2003
Resolution: Motor-room air-lock doors reasonably gas tight to satisfaction of class and verified by Coast Guard Marine Inspector.
Deck/Cargo
Issued 12 November 2003
No resolution recorded
No operable latch on outer door of motor room to make self-closing operation reasonably gastight; Gas Code 3.6.1, 3.6.2
Action required: 705 - Other - as specified
Due 4 July 2004 — due date passed with no resolution recorded
Deck/Cargo
Issued 12 November 2003
Resolved
Prove proper operation of all nozzles for Deck Water Spray System; 7 nozzles were not providing complete spray; Gas Code 11.3 (See narrative under activity 1947874)
Action required: 705 - Other - as specified
Due 22 November 2003
Resolved 22 November 2003
Resolution: All nozzles of deck water spray system operating properly to satisfaction of class and verified by Coast Guard Marine Inspector.
Accommodation/Occupational Safety › Refrigeration (stores)
Issued 12 November 2003
Resolved
Renew the escape latch for the frozen stores (meat storage) room; ILO 147; Prove proper operation.
Action required: 705 - Other - as specified
Due 22 November 2003
Resolved 22 November 2003
Resolution: Escape latch renewed to satisfaction of class and verified by Coast Guard Marine Inspector.
Accommodation/Occupational Safety › Refrigeration (stores)
Issued 12 November 2003
Resolved
Frozen stores (fish storage) room escape alarm is inoperable; ILO 147; Prove proper operation.
Action required: 705 - Other - as specified
Due 22 November 2003
Resolved 22 November 2003
Resolution: Alarm operational to satisfaction of class and verified by Coast Guard Marine Inspector.
Construction/Loadline › Markings
Issued 12 November 2003
Resolved
Paint Load Line markings in contrasting color with the hull; ICLL/Reg 8.
Action required: 705 - Other - as specified
Due 22 November 2003
Resolved 22 November 2003
Resolution: Load Lines painted in contrasting color to satisfaction of class and verified by Coast Guard Marine Inspector.
Operations/Management › Pollution
Issued 19 May 2002
Resolved
Due to evidence of inconsistencies in GAZ DIAMOND's Safety Management System, the GAZ DIAMOND should undergo an additional ISM audit by issuing authority. The audit shall be conducted in the presence of attending Coast Guard Marine Inspector (reference SOLAS Chapter IX.) LEGACY COMPONENT DESC: Compliance with Transfer Procedures
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2002
Resolved 23 May 2002
Resolution: Bureau Veritas conducted ISM audit of pollution prevention procedures. Auditor addressed four non-conformities in the safety management policies and procedures of the owner.
Documentation › Manuals/Policy Documentation
Issued 19 May 2002
Resolved
Oil transfer procedures were not in accordance with 33 CFR 155.750. LEGACY COMPONENT DESC: Transfer Procedures
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2002
Resolved 23 May 2002
Resolution: GAZ DIAMOND provided a final copy of oil transfer procedures in accordance with 33 CFR 155.750; the procedures have been incorporated into the safety management policies and procedures of the company.
Pollution Prevention/Response › Prevention Equipment
Issued 19 May 2002
Resolved
H.F.O. bunker relief valve malfunctioned which caused overflow of oil from H.F.O. port bunker tank (designated as overflow tank) to deck and into navigable waters. Required to make repairs to relief valve and demonstrate proper operation to the satisfaction of class and attending CG inspectors. LEGACY COMPONENT DESC: Overfill Devices
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2002
Resolved 21 May 2002
Resolution: H.F.O bunker relief valve removed ashore, overhauled, and tested to set pressure using currently calibrated gauges. Class and attending CG inspectors witnessed fit-up of repaired valve.
Engineering › Fuel Oil Storage/Transfer System
Issued 19 May 2002
Resolved
Modifications had been made to H.F.O. bunker piping system in July 2001 during most recent drydock period. Vessel should demonstrate that the bunker piping system is properly configured for its intended purpose and that all documents and guidance properly reflect the system design. LEGACY COMPONENT DESC: Piping
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2002
Resolved 23 May 2002
Resolution: Lloyds Classification Society submitted the following conditions of class: H.F.O. bunker pipeline be hydrotested in entirety under survey at next port of call; plan of complete H.F.O bunker piping system, including valves, be submitted for approval.
Electrical
Issued 17 November 2001
Resolved
PORT EMBARKATION LIGHT NOT WORKING.
Condition: Unknown
Due 20 November 2001
Resolved 5 December 2001