MAURY USCG vessel records Sign in
← All vessels

NARVA

NARVA is a 1978 freight ship. The Coast Guard has recorded 30 inspections since 1993, most recently in December 1999, along with 34 deficiencies — 2 with no resolution recorded — and 3 operational controls.

Records from 1993 to 1999. Most recent: inspection, 13 December 1999.

Built
1978
Last inspected
13 December 1999
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7831018 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
389276
Flag
SOVIET UNION
—
Maury page id
psix-389276

Inspections, by type

…with no type recorded30
…past their stated due date2
Years with a record 7 calendar years (1993–1999)
The 30 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 27 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it8548 - Regulatory (Subpart C or D), Gross Ton
2564 - Regulatory (Subpart C or D), Net Ton
4600 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 30

13 December 1999 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 435491
29 November 1999 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 435163
24 November 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 434975
2 June 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 429156
31 May 1999 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 429064
29 May 1998 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 116469
26 March 1998 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 414078
19 September 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 408251
9 July 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 405626
22 April 1997 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 402969
17 March 1997 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 401552
30 October 1996 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 396753
26 October 1996 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 396648
26 July 1996 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 484688
12 July 1996 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 712570
10 July 1996 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 485074
5 July 1996 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 393062
26 February 1996 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 454413
12 February 1996 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 492155
5 July 1995 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 380188
11 April 1995 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 475108
27 February 1995 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 375593
19 December 1994 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 845400
21 July 1994 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 368771
17 June 1994 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 693640
14 June 1994 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 367825
1 March 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 364930
23 July 1993 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 655111
16 July 1993 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 182782
2 June 1993 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 358524

Deficiency record · 34

Fire Fighting
Issued 13 December 1999 No resolution recorded
Have class attest to the "A" class doors in way of galley, SOLAS 60 II partD
Condition: Unknown
Due 13 January 2000 — due date passed with no resolution recorded
Construction/Loadline
Issued 29 November 1999 Resolved
AFT DRAFT LINES NOT LEGIBLE.
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Electrical
Issued 29 November 1999 Resolved
INSUFFICIENT LIGHTING IN PORTSIDE FAN SPACE ON BOAT DECK, CAR DECKS, AND_x001C_ EGRESS LADDER OUT OF ENGINE ROOM.
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Construction/Loadline
Issued 29 November 1999 Resolved
EXCESSIVE OIL IN BILGE IN FOWARD RAMP HYDRAULIC PUMP SPACE.
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Electrical
Issued 29 November 1999 Resolved
IMPROPERLY STORED 12 VOLT BATTERY IN SPACE OUTSIDE CREWS LOUNGE.
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Lifesaving
Issued 29 November 1999 Resolved
HIGH PRESSURE GAS BOTTLE IMPROPERLY STOWED ON OUTER DECK.
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Engineering
Issued 29 November 1999 No resolution recorded
DISCHARGE SIDE OF AUXILARY SEAWATER PUMP HAS A CLAMP AS TEMPORARY REPAIR.
Condition: Unknown
Due 29 December 1999 — due date passed with no resolution recorded
Accommodation/Occupational Safety
Issued 29 November 1999 Resolved
LEAKING DRAIN PIPE AND CLOGGED DECK DRAIN IN HEAD OUTSIDE OF CAPTAINS _x001C_ OFFICE.
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Engineering
Issued 29 November 1999 Resolved
CONTAINMENT FOR FUEL VENTS MISSING PLUGS.
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Fire Fighting
Issued 29 November 1999 Resolved
EMERGENCY FIRE PUMP SPACE MISSING EMERGENCY LIGHTING.
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Fire Fighting
Issued 29 November 1999 Resolved
PACKING ON EMERGENCY FIRE PUMP LEAKING EXCESSIVELY.
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Engineering
Issued 24 November 1999 Resolved
IN VIOLATION OF MARPOL 73/78 ANNEX I REG 16-PARAGRAPH 5 THE VESSEL COULD NOT PROVE PROPER OPERATION OF OILY-WATER SEPARATOR. VESSEL MUST PROVE PROPER OPERATION PRIOR TO NEXT US PORT.
Condition: Unknown
Due 28 November 1999
Resolved 28 November 1999
Documentation
Issued 2 June 1999 Resolved
OIL TRANSFER PROCEDURES ARE INCOMPLETE.
Condition: Unknown
Due 15 July 1999
Resolved 15 July 1999
Fire Fighting
Issued 9 July 1997 Resolved
CONDUCT A PROPER FIRE DRILL IN THE PRESENCE OF A COAST GUARD INSPECTOR.
Condition: Unknown
Due 2 September 1997
Resolved 2 September 1997
Lifesaving
Issued 9 July 1997 Resolved
REASSEMBLE AND PROVE PROPER OPERATION OF STBD LIFEBOAT ENGINE.
Condition: Unknown
Due 2 September 1997
Resolved 2 September 1997
Lifesaving
Issued 9 July 1997 Resolved
REPAIR ALL GRAB LINES ON STBD LIFE BOAT.
Condition: Unknown
Due 2 September 1997
Resolved 2 September 1997
Lifesaving
Issued 9 July 1997 Resolved
REPAIR OR REPLACE TWO RING BUOY LIGHTS.
Condition: Unknown
Due 2 September 1997
Resolved 2 September 1997
Navigation
Issued 17 March 1997 Resolved
EXCESS OIL ON DECK IN STEERING GEAR ROOM. MISSING NON-SLIP SURFACE. CORRECT NOT LATER THAN 26MAR97
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Deck/Cargo
Issued 17 March 1997 Resolved
CARGO HOLD VENT CLOSURE WASTED ON PORT SIDE FWD OF PILOT BOARDING STATION.
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Fire Fighting
Issued 17 March 1997 Resolved
E/R FIRE HYDRANT VALVE HANDLE SEIZED SHUT. CORRECTED ON THE SPOT.
Condition: Unknown
Due 17 March 1997
Resolved 19 March 1997
Lifesaving
Issued 17 March 1997 Resolved
01 RING BOUY LIGHT EXTINGUISHED. CORRECTED ON THE SPOT.
Condition: Unknown
Due 17 March 1997
Resolved 19 March 1997
Lifesaving
Issued 17 March 1997 Resolved
RING BOUYS NOT 4KG ON BRIDGE WINGS.
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Electrical
Issued 17 March 1997 Resolved
MISSING PROTECTIVE COVER FOR LIGHT IN EMERGENCY F/P ROOM. CORRECT NOT LATER THAN 26MAR97.
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Engineering
Issued 17 March 1997 Resolved
MISSING SIGHT GLASS TO L/O PUMP ON MAIN ENGINE.
Condition: Unknown
Due 17 March 1997
Resolved 19 March 1997
Deck/Cargo
Issued 17 March 1997 Resolved
VENT DUCT IN HYDRAULIC PUMP ROOM WASTED.
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Engineering
Issued 30 October 1996 Resolved
Vessel did not have record of date and result of most recent test and inspection of transfere lines.
Condition: Unknown
Due 1 November 1996
Resolved 1 November 1996
Construction/Loadline
Issued 26 October 1996 Resolved
ILLC 66 ANNEX I/1: ACCESS TRUNK TO ROPE LOCKER (STERN), UPPER DECK, STBD AFT; TOP HOLED & KNIFE EDGE WASTED. EFFECT PERM REPAIR AT NEXT DRYDOCK BUT NOT LATER THAN 01MAR97. TEMP REPAIR BY COVERING WITH TARPOLINE WHILE U/W.
Condition: Unknown
Due 19 March 1997
Resolved 19 March 1997
Construction/Loadline
Issued 26 October 1996 Resolved
ILLC ANNEX 66 I/1: BKHD VENT COAMING, UPPER DECK, PORT SIDE FOREWARD, IN WAY OF LADDER TO FOC'SLE DECK WASTED AND UNABLE TO SEAL. EFFECT PERM REPAIRAT NEXT DRYDOCK BUT NOT LATER THAN 01MAR97.
Condition: Unknown
Due 19 March 1997
Resolved 19 March 1997
Construction/Loadline
Issued 26 October 1996 Resolved
ILLC 66 ANNEX I/1: HOLE IN BKHD AT DECK LEVEL IN PAINT STORE ROOM, STBD SIDE. PAINT STORE ROOM LOCATED ON UPPER DECK. EFFECT PERM REPAIR AT NEXT DRYDOCK BUT NOT LATER THAN 01MAR97. TEMP REPAIR BY PLUG OR METAL PUDDY.
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Fire Fighting
Issued 5 July 1995 Resolved
VESSEL ENTERED THE PORT OF NEW YORK WITH SHIPS FIRE HOSES MISSING NOZZLES. THIS IS A VIOLATION OF SOLAS 60 II REG 56(F).
Condition: Unknown
Due 6 July 1995
Resolved 6 July 1995
Lifesaving
Issued 5 July 1995 Resolved
SHIP ENTERED THE PORT OF NEW YORK WITH THE #1 LIFEBOAT ENGINE INOPERABLE. THIS IS A VIOLATION OF SOLAS 60 III/8.35.
Condition: Unknown
Due 6 July 1995
Resolved 6 July 1995
Engineering
Issued 5 July 1995 Resolved
VESSEL'S OILY-WATER SEPERATING EQUIPMENT WAS NOT OPERATING IN ACCORDANCE WITH 33 CFR 155.380(b).
Condition: Unknown
Due 6 July 1995
Resolved 6 July 1995
Documentation
Issued 27 February 1995 Resolved
AN EXAMINATION OF THE M/V NARVA'S CERTIFICATES AND DOCUMENTS REVEALED _x001C_ THAT THE VESSEL'S SAFETY RADIO TELEGRAPHY CERTIFICATE EXPIRED RESULTING IN A VIOLATION OF CHAPTER I, REGULATION 9 OF THE INTERNATIONAL CONVENTION FOR SAFETY OF LIFE AT SEA, 1974 (SOLAS 74).
Condition: Unknown
Due 1 March 1995
Resolved 1 March 1995
Documentation
Issued 14 June 1994 Resolved
PROPER TRAINING WAS NOT PROVIDED FOR DESIGNATED PERSONNEL THAT HANDLE HAZARDOUS MATERIALS. CORRECT BY 14 JULY 94 OR PRIOR TO THE HANDLING OF HAZARDOUS MATERIALS IN NEXT U.S. PORT
Condition: Unknown
Due 21 July 1994
Resolved 21 July 1994

Ownership record