MAURY USCG vessel records Sign in
← All vessels

CHIOS

CHIOS is a 1993 tank ship. The Coast Guard has recorded 10 inspections since 1994, most recently in January 2010, along with 6 deficiencies.

Records from 1994 to 2010. Most recent: inspection, 8 January 2010.

Built
1993
Last inspected
8 January 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9043029 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
389346
Flag
GREECE
—
Maury page id
psix-389346

Inspections, by type

…with no type recorded2
Years with a record 10 calendar years (1994–2010)
The 10 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it157213 - Convention (Subpart B), Gross Ton
157213 - Simplified, Gross Ton
98396 - Convention (Subpart B), Net Ton
98396 - Simplified, Net Ton
301826 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 10

8 January 2010 COC-TVE Renew · ISPS II Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3660128
23 September 2008 ISPS II Exam · COC-TVE Renew
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3330773
22 May 2007 COC-TVE Annual · ISPS II Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2937530
22 May 2006 ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2653947
29 August 2004 ISPS II Exam · COC-TVE Renew
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2177415
2 November 2003 Annual Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1938258
16 August 2002 Tank Vessel Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1661097
27 July 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 292385
8 March 2000 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 277665
24 August 1994 Tank Vessel Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1377262

Deficiency record · 6

Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 8 January 2010 Resolved
Tank vessel is required to have emergency shutdown for cargo pumps, cargo pumps 1 and 2 currently have no functional shutdowns.
Due 15 January 2010
Resolved 9 January 2010
Resolution: Proper repairs were made to emergency shut downs, now operable. See attached class report.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 8 January 2010 Resolved
Inert gas system is required to have audible and visual alarms for high gas temperature, alarm on panel currently inoperable.
Due 15 January 2010
Resolved 9 January 2010
Resolution: Audible and visual alarm on alarm panel has been repaired. See attached class report.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 2 November 2003 Resolved
Ensure all stairway doors are self closing. All stairway doors had holdback devices (wood wedges) and/or did not fully close.
Action required: 15 - Rectify deficiencies by next port
Resolved 6 November 2003
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 2 November 2003 Resolved
Label vapor control line "Vapor" per 46CFR 39.20-1(d)(2).
Action required: 15 - Rectify deficiencies by next port
Resolved 6 November 2003
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 2 November 2003 Resolved
Label cargo tank overfill alarm on deck "tank overfill alarm" per 46 CFR 39.20-7(d)(3)
Action required: 15 - Rectify deficiencies by next port
Resolved 6 November 2003
Deck/Cargo › Holds/Tanks
Issued 16 August 2002 Resolved
Prior to cargo operations, repair liquid level guaging for cargo tanks. LEGACY COMPONENT DESC: Liquid Level Gaging
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 August 2002
Resolution: Received fax from technician stating that the guaging system was repaired.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.