Records from 2009 to 2025. Most recent: inspection, 29 May 2025.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 December 2024
Resolved
Vessel was discovered to have a COI overdue for its annual inspection. To maintain a valid COI, the vessel must complete its annual inspection within 3 months of the anniversary date.
Vessel is restricted from carrying passengers for hire until it completes a satisfactory annual inspection.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 December 2024
Resolution: Attended vessel and completed COI and all SAT
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 28 November 2023
Resolved
Aspirin contained in vessel first aid kit found to be expired. Replace expired contents.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 December 2023
Resolved 29 November 2023
Resolution: Provided new first aid kit.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 November 2023
Resolved
Life jacket instruction not posted on vessel. Post placard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 December 2023
Resolved 29 November 2023
Resolution: Installed placard.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 28 November 2023
Resolved
EPIRB hydrostatic release found to be expired. Replace hydrostatic release.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 December 2023
Resolved 29 November 2023
Resolution: Installed new hydorstatic release.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 November 2023
Resolved
Retro reflective tape and name on Ring buoy found to be wasted. Apply new tape and stencil name.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 December 2023
Resolved 29 November 2023
Resolution: Stencilled name and installed tape.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 November 2023
Resolved
Vessel fire buckets found to be 5 gal capacity. Provide 2.5 gal fire buckets.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 December 2023
Resolved 29 November 2023
Resolution: Drilled holes at 2.5 gal mark.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 28 November 2023
Resolved
Hydraulic steering line IWO port engine found to be chafing. Install chafing gear to line.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 December 2023
Resolved 29 November 2023
Resolution: Installed chafing gear.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 November 2023
Resolved
Port no.2 fuel fill line found to be wasted. Replace line and provide CG with hose manufacturer spec sheet w' CG approval no.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 December 2023
Resolved 29 November 2023
Resolution: Installed new fill line.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 November 2023
Resolved
Stbd. fuel line from filter to bulb found to be wasted. Replace fuel line and provide CG with spec sheet and CG approval no.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 December 2023
Resolved 29 November 2023
Resolution: Installed new flex line.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 23 June 2022
Resolved
Rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers and crew.
Owner replacing all cable rungs. current installation was adequate, however, owner stated he intended to replace in kind for comsmetic appeal. MI to verify installation after complete.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 June 2022
Resolved 20 February 2024
Resolution: Rails were inspected during drydock and determined to be adequate.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 6 June 2022
Resolved
On a vessel of at least 26ft a visual and audible alarm must be provided at the operating station. Port fwd space found to have inoperable alarm. Repair audible and visual indicator for space.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2022
Resolved 9 June 2022
Resolution: Replaced float switch.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 June 2022
Resolved
Multiple electrical wires found to have open ends. Remove wire or terminate in a junction box.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2022
Resolved 9 June 2022
Resolution: Removed wires.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 March 2021
Resolved
Vessel has 43 of required 52 Adult Type I Life Jackets on board. Vessel is limited to carrying 43 total persons on board until a total of 52 Adult Type I Life Jackets are provided. Must rectify deficiency within 14 days. 46 CFR 180.71(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 March 2021
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 1 March 2021
Resolved
The required visual alarm to indicate a high water level in the forward compartment of the port hull was inoperable. Provide visual alarm. Must rectify deficiency within 14 days. 46 CFR 182.530(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 March 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 1 March 2021
Resolved
The rail courses on the bow are spaced at intervals greater than 4 inches. Install mesh or additional rail courses so that the spacing does not exceed 4 inches. Must rectify deficiency within 14 days. 46 CFR 177.900(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 March 2021
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 1 March 2021
Resolved
EPIRB testing, Abandon Ship drills, Man Overboard drills, and Fire Fighting drills are not being properly documented. Log testing, drills, and training with the date and general description and make logs available for inspection. Must rectify deficiency within 14 days. 46 CFR 185.520/524
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 March 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 March 2020
Resolved
Replace Port and STBD fuel lines from tank to filter, lines were painted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2020
Resolved 18 March 2020
Resolution: Fuel lines replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 March 2020
Resolved
Replace fuel filter bowls with those constructed of steel or an equivalent, fuel bowls are constructed of plastic
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 March 2020
Resolution: Bowls replaced with steel construction
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 4 March 2020
Resolved
Log MOB and fire drills as well as EPIRB testing and maintain log.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 March 2020
Resolution: Drills logged
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 4 March 2020
Resolved
Replace EPIRB battery, battery found expired
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 March 2020
Resolution: New EPIRB onboard
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 March 2020
Resolved
Relabel fuel shut-offs for both Port and STBD shut-offs near operating station
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 March 2020
Resolution: Shutoffs re-labeled
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 February 2019
Resolved
Mark all electrical circuts on electrical panel. Clean connections on fuses.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 March 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 February 2019
Resolved
Support all current carrying conductor at 18" intervals on STBD Side.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 March 2019
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 February 2019
Resolved
Demonstrate operation of white all around navigation light. Vessel restricted to daylight operations.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 March 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 22 February 2019
Resolved
post COI (ALL PAGES)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 March 2019
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 22 February 2019
Resolved
PROVIDE EMERGENCY INSTRUCTION FOR HEAVY WEATHER.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 March 2019
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 22 February 2019
Resolved
Provide FCC operator permit for captain.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 March 2019
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 22 February 2019
Resolved
provide current tides charts for area of operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 March 2019
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 22 February 2019
Resolved
repair replace 8 person life float. paint is faded and lines for grab handles are wasted.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 March 2019
Resolution: requested route to be reduced to 3 miles on COI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 February 2019
Resolved
SECURE BILGE HIGH LEVEL SENSOR IN PORT AFT COMPARTMENT.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 March 2019
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 22 February 2019
Resolved
REPLACE SOLAS TAPE PN 09 PFDS
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 March 2019
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 8 February 2019
Resolved
Numerous locations of concern found and marked on hull and sections of exposed glass found on each hull. Grind down to see extent of damage. Remove damaged FRP and replace IAW with NVIC 8-87.
Action required: 705 - Other - as specified
Resolved 22 February 2019
Resolution: cleared via pictures sent to CID
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 February 2019
Resolved
Identified and marked locations of cracked welds on canopy structure. Grind down and repair welds.
Action required: 705 - Other - as specified
Resolved 22 February 2019
Resolution: REWELDED
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 8 February 2019
Resolved
Railings coming up on deck allowing water to penetrate holds. Reseal railings.
Action required: 705 - Other - as specified
Resolved 22 February 2019
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 8 February 2019
Resolved
provide waste management plan for vessel
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 March 2019
Construction/Loadline › Hull › Bottom Plating
Issued 30 March 2018
Resolved
Conduct hull survey following grounding
Action required: 17 - Rectify deficiencies prior to departure
Due 30 March 2018
Resolved 2 April 2018
Resolution: Video hull survey conducted, no damage noted.
Navigation › Piloting/Steering › Magnetic Compass
Issued 23 February 2018
Resolved
Provide light for magnetic compass.
Action required: 705 - Other - as specified
Due 2 March 2018
Resolved 1 March 2018
Resolution: Provided light for compass.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 23 February 2018
Resolved
Provide updated nav pubs for vessel's operating area.
Action required: 705 - Other - as specified
Due 2 March 2018
Resolved 1 March 2018
Resolution: Provided required nav pubs and charts for operating area.
Engineering › Bilge Water Management System › Valve
Issued 23 February 2018
Resolved
Install check valve in port bilge suction line.
Action required: 705 - Other - as specified
Due 2 March 2018
Resolved 1 March 2018
Resolution: Installed a check valve in suction line.
Lifesaving › Lifefloat › Serviceable
Issued 10 March 2017
Resolved
Repair 8 person life float in accordance with manufactures instructions.
Action required: 705 - Other - as specified
Due 10 April 2017
Resolved 5 April 2017
Resolution: 8 person life float repaired.
Lifesaving › Lifefloat › Markings
Issued 10 March 2017
Resolved
Label life floats with capacity and name and secure paddles.
Action required: 705 - Other - as specified
Due 10 April 2017
Resolved 14 April 2017
Resolution: 8 person and 22 person life float labeled.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 10 March 2017
Resolved
Post emergency instruction list.
Action required: 705 - Other - as specified
Due 17 March 2017
Resolved 14 April 2017
Resolution: Emergency instructions posted.
Electrical › Electric Supply System (service) › Battery Installation
Issued 10 March 2017
Resolved
Secure battery inside operating console.
Action required: 705 - Other - as specified
Due 10 April 2017
Resolved 10 March 2017
Resolution: Battery secured and covered.
Electrical › Electric Supply System (service) › Cable
Issued 10 March 2017
Resolved
Properly secure cables in starboard hull (Every 24")
Action required: 705 - Other - as specified
Due 10 April 2017
Resolved 10 March 2017
Resolution: Wires secured.
Communications › Alarms/Indicators › High Water Alarm
Issued 10 March 2017
Resolved
Relable the following: Bilge high level indicators, PFD stowage locations, FWD portable fire extinguishers, donning placards (PFD's), Vessel name on stern (Missing "I").
Action required: 705 - Other - as specified
Due 17 March 2017
Resolved 5 April 2017
Resolution: All required labels and placards installed.