LAGOON PHOENIX

LAGOON PHOENIX is a 1993 freight ship. The Coast Guard has recorded 16 inspections since 2016, most recently in September 2024, along with 39 deficiencies and 3 operational controls.

Records from 2016 to 2024. Most recent: inspection, 7 September 2024.

Built
1993
Last inspected
7 September 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 7 September 2024
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9047245
389629
Flag
CURACAO
Maury page id
psix-389629

Documentation record

Tonnage as PSIX records it4808 - Convention (Subpart B), Net Ton
7313 - Convention (Subpart B), Gross Ton
8044 - Dead Weight, Metric Ton
12042 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

16 inspections, each with its date, unit and type; 39 deficiencies with the resolution recorded against each; 3 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 16

7 September 2024 PSC A · Deficiency Check
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 7992714
17 August 2022 Deficiency Check · PSC A
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7529900
22 July 2022 PSC A · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7508086
27 June 2022 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7489093
23 June 2022 PSC A
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7479058
19 May 2022 PSC B · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7450448
22 February 2022 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7396755
20 February 2022 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7399452
16 February 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7397263
13 July 2021 PSC A
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7254519
25 May 2018 PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6418278
26 September 2017 PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6269528
24 April 2017 PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6128609
22 April 2017 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6130403
19 April 2017 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6128393
8 June 2016 Deficiency Check · ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5895283

Deficiency record · 39

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 August 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. A temporary cement patch repair of the engine room main sea chest was carried out by the ship’s crew without reporting same to its flag administration in accordance with SOLAS 74(97) 1/11C.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 September 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 August 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The engine room main sea chest vent is fractured/holed with a temporary repaired carried out by the ship’s crew without reporting same to its flag Administration in accordance with SOLAS 74(97) 1/11A.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 September 2024
Resolution: Vessel made repairs prior to survey by blinding the pipe from the sea side then removed the wasted pipe and valve. Blind flange was fitted on top of the sea chest flange. Class Condition was deleted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 August 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Subsequently, the ship’s crew carried out temporary repairs by welding a double on the fuel return piping without reporting same to its recognized organization, Bureau Veritas, in accordance with SOLAS 74(97) 1/11C.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 September 2024
Resolution: Vessel made repairs prior to their dry dock, class survyeors reported "H.P. F.O. line in front of aux eng nr 1 found with patch in pipe. Renewed earlier."
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 August 2022 Resolved
Whenever an accident occurs to a ship or a defect is discovered, either of which affects the safety of the ship or the efficiency or completeness of its equipment, the master or owner of the ship shall report at the earliest opportunity to the Administration, the nominated surveyor or recognized organizations responsible for issuing the relevant certificate, who shall cause the investigations to be initiated to determine whether a survey, as required by applicable regulations is necessary. The master or owner of the ship failed to notify the flag Administration, recognized organization or Port State of the deficiencies discovered which affected the safety of the ship or completeness of its equipment.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 September 2024
Resolution: Audit was conducted and owner of the vessel has since been changed.
09 - Working and Living Conditions › 092 - Working Conditions › Winches & capstans
Issued 31 August 2022 Resolved
In addition to the requirements contained elsewhere in the present SOLAS regulations, ships shall be maintained in compliance with the structural, mechanical and electrical requirements of classification society. Port and Starboard mooring winch gypsy wheels are worn and require repairs or replacement in accordance with approved classification society procedures.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 September 2024
Resolution: All 08 cargo winches (gypsy wheels) were replaced at the vessel dry dock and noted by the Class Society.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 August 2022 Resolved
In addition to the requirements contained elsewhere in the present SOLAS regulations, ships shall be maintained in compliance with the structural, mechanical and electrical requirements of classification society. Doubler was installed on the seawater cooling for the ship’s cargo hold refrigeration plant located in the starboard side engine room in way of Freon tank and freshwater generator.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 September 2024
Resolution: The space for compressor for refrigeration purpose was found in use as storage. During survey the crew was not able to clear / relocate same. A permanent solution is to be found for same. Condition of Class for repair issued.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 17 August 2022 Resolved
FIREFIGHTING SYSTEMS AND APPLIANCES SHALL BE KEPT IN GOOD WORKING ORDER AND READILY AVAILABLE FOR IMMEDIATE USE. MAIN FIRE PUMP LOCATED IN ENGINE ROOM IS INOPERABLE DUE TO MALFUNCTIONING ELECTRICAL MOTOR DRIVE UNIT. 74SOLAS(20)II-2/14.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 31 August 2022
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 August 2022 Resolved
CONNECTIONS WITHIN THE FUEL SUPPLY AND SPILL LINES SHALL BE CONSTRUCTED HAVING REGARD TO THEIR ABILITY TO PREVENT PRESSURIZED OIL FUEL LEAKS WHILE IN SERVICE AND AFTER MAINTENANCE. PSCO OBSERVED EXCESSIVE FUEL LEAK ON NUMBER NO.2 GENERATOR FUEL LINE RESULTING IN ATOMIZING FUEL COMING INTO CONTACT WITH A HOT SURFACE. 74SOLAS(20)II-2/4.2.2.5.4
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 31 August 2022
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 17 August 2022 Resolved
IN ADDITION TO THE REQUIREMENTS CONTAINED ELSEWHERE IN THE PRESENT SOLAS REGULATIONS, SHIPS SHALL BE DESIGNED, CONSTRUCTED AND MAINTAINED IN COMPLIANCE WITH THE STRUCTURAL, MECHANICAL AND ELECTRICAL REQUIREMENTS OF A CLASSIFICATION SOCIETY. THE PORT GENERAL SERVICE PUMP, WHICH IS PRESENTLY BEING UTILIZED AS THE VESSELS MAIN FIRE PUMP, HAS TWO SOFT PATCHES ON THE DISCHARGE PIPING. 74SOLAS(04)II-1/3-1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 31 August 2022
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 17 August 2022 Resolved
FIREFIGHTING SYSTEMS AND APPLIANCES SHALL BE KEPT IN GOOD WORKING ORDER AND READILY AVAILABLE FOR IMMEDIATE USE. EMERGENCY FIRE PUMP HAS A BROKEN BEARING SUPPORT ATTACHED TO THE VOLUTE AND EXCESSIVE LEAKING COMING FROM THE SHAFT PACKING GLAND. FUTERHERMORE, DURING OPERATION OF THE EMERGENCY FIRE PUMP, SMOKE WAS EMITTING FROM THE OVERTIGHTENED PACKING GLAND. 74SOLAS(20) II-2/14.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 31 August 2022
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 August 2022 Resolved
CONNECTIONS WITHIN THE FUEL SUPPLY AND SPILL LINES SHALL BE CONSTRUCTED HAVING REGARD TO THEIR ABILITY TO PREVENT PRESSURIZED OIL FUEL LEAKS WHILE IN SERVICE AND AFTER MAINTENANCE. NUMEROUS EXCESSIVE FUEL LEAKS WERE IDENTIFIED ON THE NO.1 GENERATOR IN WAY OF THE NO.3 AND NO.5 JERK PUMPS CAUSING A FIRE HAZARD.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 31 August 2022
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 17 August 2022 Resolved
THE COMPANY SHOULD ESTABLISH PROCEDURES TO ENSURE THAT THE SHIP IS MAINTAINED IN CONFORMITY WITH THE PROVISIONS OF THE RELEVANT RULES AND REGULATIONS AND WITH ANY ADDITIONAL REQUIREMENTS WHICH MAY BE ESTABLISHED BY THE COMPANY. SHIPS SMS STATES THAT THE DRAIN LINES ARE TO BE INSPECTED AND TESTED WITH WATER TO ENSURE OPERABILITY. PSCO OBSERVED MISSING DRAIN LINE ON FORWARD STBD SIDE OF NUMBER TWO CARGO HATCH AFTER MAINTENANCE RECORDS INDICATED THAT IT HAD BEEN VERIFIED OPERATIONAL ON 25JUL2022. 74SOLAS(20) IX/3.1, ISM CODE PART A/10.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 31 August 2022
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 17 August 2022 Resolved
THE COMPANY SHOULD ESTABLISH PROCEDURES TO ENSURE THAT THE SHIP IS MAINTAINED IN CONFORMITY WITH THE PROVISIONS OF THE RELEVANT RULES AND REGULATIONS AND WITH ADDITIONAL REQUIREMENT WHICH MAY BE ESTABLISHED BY THE COMPANY. DUE TO THE DEFICIENCIES OF A TECHNICAL AND /OR OPERATIONAL NATURE IDENTIFIED ABOVE WHICH INDIVIDUALLY OR COLLECTIVELY PROVIDES OBJECTIVE EVIDENCE OF A SERIOUS FAILURE, OR LACK OF EFFECTIVENESS OF THE ISM CODE. AN EXTERNAL AUDIT SHALL BE CONDUCTED BY THE FLAG ADMINISTRATION OR RECOGNIZED ORGINIZATION ACTING ON BEHALF OF THE FLAG ADMINISTRATION BEFORE THE VESSEL WILL BE RELEASED FROM ITS DETENTION TO DETERMINE WHETHER THE VESSEL IS OPERATING IN COMPLIANCE WITH THE ISM CODE. A COPY OF THE COMPLETED EXTERNAL AUDIT SHALL BE PROVIDED TO THIS OFFICE FOR REVIEW PRIOR TO DEPARTURE FROM THE PORT OF MOBILE. 74SOLAS(20) IX/3.1, ISM CODE PART A/ 10.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 31 August 2022
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 22 July 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. PSCO observed patch on seawater cooling line for cargo hold refer plant located STBD side engine room near Freon tank & freshwater generator. 74 SOLAS (20) 1/11(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 July 2022
Resolved 26 July 2022
Resolution: Temp doubler placed over leaks and approved by class/CG until repairs are made in the yard in Feb 2023.
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 22 July 2022 Resolved
COTP may direct the handling of oil or hazardous materials to protect the navigable waters of the United States. PSCO observed fuel oil samples stowed in steering gear space. 33CFR160.109
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 July 2022
Resolution: Samples moved to appropriate storage container approved by class.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 June 2022 Resolved
The rating or appropriate setting of the overload protective device for each circuit shall be permanently indicated at the location of the protective device. PSCO observed emergency steering pump motor controller was triple-tapped due to installation of 440V outlets. PSCO observed boat davit, main engine aux. blower and #4 crane motor controllers similarly double-tapped.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 23 June 2022
Resolved 22 July 2022
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 23 June 2022 Resolved
Fire doors in main vertical zone bulkheads and stairway enclosures shall satisfy the following. The doors shall be self closing. PSCO observed steering gear door being propped open by security door and STBD engine room door to main deck would not self close.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 23 June 2022
Resolved 25 June 2022
Resolution: RCVD Class report attesting the the steering gear door no longer being propped open and STBD engine room door able to self close.
14 - Pollution Prevention › 141 - MARPOL Annex I › Suspected of discharge violation
Issued 23 June 2022 Resolved
Any discharge into the sea of oil or oily mixtures from ships shall be prohibited. PSCO observed a sheen coming from the #3 crane hydraulic cooling discharge port. Hydraulic system restricted from any use resulting in oil discharge.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 June 2022
Resolved 25 June 2022
Resolution: Vessel submitted class documentation satisfying the requirements. The #3 crane hydraulic cooling system has been pressure tested and no leaks were detected at the time of the survey.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 23 June 2022 Resolved
All hatchways in position 1 and 2 shall be weathertight and fitted with gaskets. PSCO observed gaskets for the hatch to cargo hold #1 were loss and deteriorated.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 June 2022
Resolved 25 June 2022
Resolution: Vessel submitted class report satisfying the requirements. The gasket on the #1 Cargo Hold has been replaced.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 May 2022 Resolved
Fire Safety - Means shall be provided to control leaks of flammable liquids. PSCO identified leak on the Number 1 Fuel Oil Supply Pump with oil accumulating in the bilge. 74 SOLAS (04) II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 May 2022
Resolution: New driving-shaft packing seal was installed on the pump. All O-rings were replaced. Witnessed no leaking and bilge was clean.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 19 May 2022 Resolved
Ships shall be designed, constructed, and maintained in compliance with the structural, mechanical, and electrical requirements of a classification society. PSCO observed excessive saltwater leak on frost pump for cargo refrigeration causing large accumulation of water in bilge. 74 SOLAS (20) II-1/3-1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2022
Resolved 25 May 2022
Resolution: Cooling tube was replaced inside the frost pump. Witnessed no leaking
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 May 2022 Resolved
Ships shall be designed, constructed, and maintained in compliance with the structural, mechanical, and electrical requirements of a classification society. PSCO observed leak on Main Fire Pump causing excessive water accumulation in bilge. 74 SOLAS (20) II-1/3-1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2022
Resolved 25 May 2022
Resolution: The packing gland was tightened on the main fire pump. drainage piipe from drip tray was cleared of obstruction. Witnessed no leaking and no back up in drainage.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 19 May 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed oil accumulation in engine room bilges and area underneath generators. Excessive oil was found in non-approved containments made of metal cans and multiple plastic bottles. 74 SOLAS (20) I/11a
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 25 May 2022
Resolution: All oil was cleaned from the bilges and underneath generators. Oil in non-approved containers was disposed of in sludge tank. Witnessed no oil in bilges.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 19 May 2022 Resolved
Satisfactory means in the form of guard rails and lifelines shall be provided for the protection of the crew in getting to and from their quarters, the machinery space and all other parts used in the necessary work of the ship. PSCO observed multiple ladder rails and guard rails with broken or missing safety devices while on deck walk. ICLL I/25-4
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 May 2022
Resolution: New safety lines were installed on ladder rails. Guard rails and stanchions were replaced.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 19 May 2022 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in these divisions. PSCO identified a fire door on deck A and deck B leading outside the ship without a proper seal allowing air and light to pass through. 74 SOLAS (20) II-2/14.2.1.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 May 2022
Resolution: New gasket was added to the doors on Deck A and B. Witnessed a proper close and no light was seen through.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 May 2022 Resolved
No electrical equipment shall be installed in any space where flammable mixtures are liable to collect, e.g. in compartments assigned principally to accumulator batteries, paint lockers, acetylene stores or similar spaces, unless the Administration is satisfied that such equipment is: of type which will not ignite in the mixture concerned. PSCO noted explosion proof light in Paint Locker did not meet that of original design. Explosion proof light was missing protective cage. 74 SOLAS (04) II-1/45.10.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 May 2022
Resolution: Protective cage was replaced on the explosion proof light.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 19 May 2022 Resolved
Self-igniting lights required by regulations III/7.1.3 shall be capable of burning continuously. PSCO noted self-igniting light on a starboard lifebuoy near the pilot ladder would not remain lit when tested. 74 SOLAS (97) III/31.2.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 19 May 2022
Resolution: vessel replaced light
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 19 May 2022 Resolved
Ships shall be designed, constructed, and maintained in compliance with the structural, mechanical, and electrical requirements of a classification society. PSCO observed Crane Hydraulic system located on Starboard side between Cargo Holds 3 and 4 leaking hydraulic oil onto the deck. 74 SOLAS (20) II-1/3-1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2022
Resolved 25 May 2022
Resolution: New hydraulic fitting was installed on starboard side crane. Witnessed no leaks
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 February 2022 Resolved
Fire Safety-Means shall be provided to control leaks of flammable liquids. PSCO and team identified numerous leaks of fuel, oil, and water on port side aft main engine, lagging and bilges. 74SOLAS(94)II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 February 2022
Resolution: fixed leaks on piping, replaced lagging, and cleaned bilges. Class attended and also confirmed repairs of leaks.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 February 2022 Resolved
Means shall be provided to control leaks of flammable liquids. PSCO and team identified fuel oil leak from number one generator leak was coming off the fuel line from jerk pump causing it to spray fuel. 74SOLAS(97)II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 22 February 2022
Resolution: Ships force replaced O-ring fixing leak.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 February 2022 Resolved
Ships shall be designed, constructed, and maintained in compliance with the structural, mechanical, and electrical requirements of the classification society. PSCO observed the number 7 cylinder has excessive jacket water leak causing excessive accumulation in bilge. 74SOLAS(20)II-1/3-1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 May 2022
Resolution: Vessel provided class reprot and psco verified leak was resolved
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 22 February 2022 Resolved
Ships shall be designed, constructed, and maintained in compliance with the structural, mechanical and electrical requirements of a classification society. PSCO observed excessive saltwater leak on cooling pump causing excessive accumulation in bilge. 74SOLAS(20)11-1/3-1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 May 2022
Resolution: Recieved and reviewed class report. PSCO verified leak was repaired.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 February 2022 Resolved
Ships shall be designed, constructed, and maintained in compliance with structural, mechanical, and electrical requirements of a classification society. PSCO observed chafed protective covering on electrical wire. 74SOLAS(20)II-1/3-1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 25 May 2022
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 25 May 2018 Resolved
0999-Other(safety in General) - The fire resistance of doors shall, as far as practicable, be equivalent to that of the division in which they are fitted. Doors and Door frames in "a" class divisions shall be constructed of steel. PSCO observed door in galley portside witha vent at the bottom and multiple air gaps around the frame. PSCO also checked fire control plan and verified door was an A-Boundary self closing door. SOLAS 74 (1997) Ch. II-2/47
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 May 2018
Resolution: Received, reviewed and accepted class report from [name withheld] stating the deficiency was rectified. The crew replaced the galley door with a new A30 self-closing door.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 24 April 2017 Resolved
1020-Fire Alarm-Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. 02 alarms inoperative and 01 alarms broken. Inoperative alarms locations STBD side generator flat and main entrance to engine room. Broken alarm is located on bottom deck engine room, starboard side. SOLAS 74 (2014) II-2/14.2.1.2 17a
Action required: 705 - Other - as specified
Resolved 28 April 2017
Resolution: Received, reviewed and accepted class report from [name withheld] stating the deficiencies were rectified. The 2 inoperative alarms were repaired and the broken alarm replaced with on board spare. Alarms were tested satisfactory.
Engineering › Steering Gear System › Motor
Issued 24 April 2017 Resolved
0936-Steering gear-In the event of a failure of electrical power supply to the steering gear control system, an audible and visual alarm shall be given on the navigation bridge. PSCO observed no visual or audible indication when power was secured to both #1 and #2 steering pumps. Chief had to pull relay in each motor controller to initiate alarms. SOLA 74 (2014) II-1/29.8.4 17a
Action required: 705 - Other - as specified
Resolved 28 April 2017
Resolution: Received, reviewed and accepted class report from [name withheld] stating the deficiencies were rectified. Both sterring gear pumps were operationally tested to the satifcation of the attending Surveryor.
Engineering › Fuel Oil Storage/Transfer System › Manifold
Issued 8 June 2016 Resolved
1420-Cleanlieness of Engine Room-In a ship in which oil fuel is used, the arrangements for the storage, distribution, and utilization of the oil fuel shall be such to ensure the safety of the ship and persons on board. PSCO observed containment placed throughout the engine room full of oil. 74 SOLAS (14 CONS) Chapt II-2 Reg 4/2.2
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 8 June 2016
Resolution: PSCO verified deficiency was corrected on the spot.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 8 June 2016 Resolved
0999 - Other - The condition of the ship and its equipment shall ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or person on board. PSCO observed modified sewage line over HFO Tank. Line was resting on HFO Tank and starting to warp. 74 SOLAS (14 Cons) Chapt 1 Reg II a
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 September 2017
Resolution: Completed a PII safety exam
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 8 June 2016 Resolved
1730 - OWS Equipment -The condition of the ship and its equipment shall ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO ovserved a soft patch on OWS piping. 74 SOLAS (14 CONS) Chap 1 Reg II a
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 September 2017
Resolution: Completed a PII safety exam