Records from 1993 to 2020. Most recent: inspection, 3 June 2020.
Inspection history · 41
3 June 2020
Type not recorded
No type recorded · Station Philadelphia · USCG East District (CGD-E) · Activity 6973609
6 July 2018
PI Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6457963
4 July 2018
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6472455
10 February 2009
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3415210
6 August 2008
PII Safety Exam · ISPS II Exam · MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3290862
26 February 2008
MARPOL Annex V Examination · PII Safety Exam · Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3151164
22 December 2007
Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam · MARPOL Annex V Examination · ISPS II Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3117600
9 October 2007
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3075855
19 September 2007
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3061580
22 June 2007
Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2970124
15 March 2007
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2888235
2 February 2007
Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2865961
13 June 2006
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2678271
26 September 2005
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2501111
10 June 2005
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2386095
12 May 2005
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2355895
10 May 2005
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2353747
25 October 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2227628
17 October 2004
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2222572
16 October 2004
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2223037
15 July 2004
ISPS I Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2133673
14 July 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2132906
25 May 2004
MTSA/ISPS Verification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2077440
26 March 2004
Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2031891
14 March 2003
Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1757255
13 February 2003
Type not recorded
No type recorded · USCGC NORTHLAND (WMEC 904) · Activity 1778457
14 December 2002
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1731596
15 November 2001
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 295348
17 November 1999
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 434818
17 December 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 423692
12 January 1998
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 411214
29 January 1997
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 399833
1 July 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 392726
27 June 1996
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 468223
29 November 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 462711
24 November 1995
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 385142
29 August 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 536876
5 November 1994
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 372052
5 November 1994
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1178279
25 January 1994
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 519839
2 June 1993
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 358642
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 July 2018
No resolution recorded
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards;
- PSCO observed exposed wires from previously installed equipment in engine room.
74SOLAS(04) II-1/40.1.3 40A/C
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 July 2018
No resolution recorded
Ship and its equipment shall be maintained to its condition after survey;
- PSCO observed dehumidifier for air intake on diesel generators installed after survey. Safety hazards include loose wires and unmounted equipment.
74SOLAS(14)I/11 40A/C
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Lifesaving › Lifeboat › Watertight Enclosure
Issued 10 February 2009
No resolution recorded
74SOLAS(97 Cons.)Ch. III Reg 44.2 Port side lifeboat has crack in vicinity of access hatch located in center of lifeboat. Crack extend below center dogging device cutting through knife edge. Dogging device doesn't make contact with striking plate preventing seal in this area. Hose test conducted and minor water intrusion was noted. Class to attest to repairs and structure integrity.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Lifesaving › Lifeboat › Hull
Issued 10 February 2009
No resolution recorded
74SOLAS (04 Cons) Ch. III Reg 20.2 Port and starboard lifeboats have deteriorating flooring between fuel tank and engine box, which may lead to floor failure and personal injury to crew if used as a step. Class to attest to floor integrity.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Engineering › Steam System (main) › Valve
Issued 22 December 2007
Resolved
Repair to the satisfaction of the attending class surveyor. The boiler blow down skin valve, where there is a cement patch installed on the piping, adjacent to the side shell.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 December 2007
Resolution: NKK was on board 12/22/2007, and recommended that the following temporarily repaired/cracked parts are to be permanently repaired by next Dry Docking Survey due on 09 August 2008 subject to satisfactory examination at periodical survey.
Construction/Loadline › Structures › Door
Issued 2 February 2007
Resolved
Cracks were found next to the following doors: Pantry Door Starboard and above Engine Room Control Room Door. Corrected to the satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 28 February 2007
Resolved 15 March 2007
Resolution: Received report of repairs, see attached "crack repair"
Operations/Management › Ballast Water Managment › Training
Issued 2 February 2007
Resolved
Ballast Water Management Plan: Crew Training and familiarizations not being conducted. Note: vessel does not have 2006 Marpol on board.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 28 February 2007
Resolved 15 March 2007
Resolution: Received report of ballast water training for crew
Operations/Management › Pollution › Control of Garbage
Issued 2 February 2007
Resolved
GMP does not identify storage or handling procedures for batteries, fluorescent tubes or medical waste.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 28 February 2007
Resolved 15 March 2007
Resolution: Recieved report with new procedures outlineing guildlines for batteries, fluorestcent tubes or medical waste.
Navigation › Collision/Grounding Avoidance › Radar
Issued 25 October 2004
Resolved
Subject vessel wishes to depart the Port of New York with an inoperable Secondary Radar and has arranged to have repairs made after departing the Port of New York.
16Oct04: Vessel sends us a repair report showing the deficiency has been corrected.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 25 October 2004
Resolution: Subject vessel wishes to depart the Port of New York with an inoperable Secondary Radar and has arranged to have repairs made after departing the Port of New York.
16Oct04: Vessel sends us a repair report showing the deficiency has been corrected.
Navigation › Collision/Grounding Avoidance › Radar
Issued 17 October 2004
Resolved
2nd radar inop. LOD issued for entry only into the COTP Baltimore Zone.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 19 October 2004
Resolved 19 October 2004
Navigation › Collision/Grounding Avoidance › Radar
Issued 16 October 2004
Resolved
INOP Secondary Radar
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 17 October 2004
Resolved 17 October 2004