Records from 1993 to 2019. Most recent: inspection, 15 June 2019.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 22
15 June 2019
Type not recorded
No type recorded · Station Gloucester · USCG Northeast District (CGD-NE) · Activity 6715395
5 January 2012
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4218928
13 December 2011
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4207337
25 June 2008
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3247680
10 July 2007
COI Inspection · Deficiency Check · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2990645
26 June 2006
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2691855
8 June 2004
Annual Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2149679
1 July 2003
Hull Examination · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1831318
3 July 2002
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1648323
3 July 2001
Re-Inspection · Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1379523
28 June 2000
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1381941
23 June 1999
COI Inspection · Hull Examination · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1077665
7 July 1998
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 798268
30 June 1997
Hull Examination · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1112859
27 June 1996
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1243691
7 June 1995
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 878587
7 June 1995
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 878589
25 May 1994
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1171685
24 August 1993
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 846726
21 June 1993
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1153785
27 May 1993
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1403636
21 May 1993
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1403637
Documentation › Certificates/Documents › Stability Letter
Issued 13 December 2011
Resolved
THE VESSEL'S OWNER/OPERATOR HAS NOT REQUESTED AN INITIAL OR UPDATED STABILITY LETTER OR HAS NOT CERTIFIED COMPLIANCE WITH THE REVISED STABILITY CRITERIA FOR ASSUMED AVERAGE WEIGHT PER PERSON (AAWPP) OF 185 POUNDS. TO VERIFY COMPLIANCE, A STABILITY TEST MUST BE COMPLETED. BASED UPON A WEIGHT RATIO CALCULATION, THE VESSEL'S CAPACITY IS THERFORE LIMITED TO: 08 PERSONS(PASSENGERS AND CREW)
Action required: 705 - Other - as specified
Due 1 June 2012
Resolved 5 January 2012
Resolution: Vessel status has changed to UPV.
Communications › Alarms/Indicators › Bilge Alarm
Issued 25 June 2008
Resolved
Fix bilge alarm panel light on console
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 June 2008
Resolved 26 June 2008
Resolution: Installed new bulb to panel
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 25 June 2008
Resolved
Service fixed fire extinguishing sysytem
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 June 2008
Resolved 26 June 2008
Resolution: Fixed system serviced
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 10 July 2007
Resolved
Engine shut down did not work and no override switch installed.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 10 July 2007
Resolved 10 July 2007
Resolution: Vessel rep procured proper system and installed.
Lifesaving
Issued 23 June 1999
Resolved
RENEW LIFE RING BUOY.
Condition: Unknown
Due 3 July 1999
Resolved 3 July 1999
Documentation
Issued 27 May 1993
Resolved
PROVIDE PROPER FCC CERTIFICATES FOR THE INSTALLED VHF RADIO.
Condition: Unknown
Due 27 May 1993
Resolved 27 May 1993