AMBASSADOR is a 1993 freight ship. The Coast Guard has recorded 25 inspections since 1993, most recently in June 2006, along with 15 deficiencies.

Records from 1993 to 2006. Most recent: inspection, 7 June 2006.

Built
1993
Last inspected
7 June 2006
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9047013 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
389796
Flag
BAHAMAS, THE
—
Maury page id
psix-389796

Inspections, by type

…with no type recorded19
Years with a record 12 calendar years (1993–2006)
The 25 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it15884 - Regulatory (Subpart C or D), Gross Ton
15884 - Convention (Subpart B), Gross Ton
8992 - Regulatory (Subpart C or D), Net Ton
8992 - Convention (Subpart B), Net Ton
26465 - Dead Weight, Metric Ton
32206 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 25

7 June 2006 PII Safety Exam · Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2669755
31 October 2004 PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2229273
10 April 2002 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1603216
18 March 2002 MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1490592
21 July 2001 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 291996
19 July 2000 Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 280260
19 July 2000 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1051827
7 June 2000 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 278283
22 December 1999 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 435751
21 May 1999 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 428655
16 January 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 424544
9 July 1998 Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 417725
9 April 1998 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 414660
24 February 1998 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 780305
20 December 1997 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 411096
29 April 1997 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 402994
22 November 1996 Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 397622
25 June 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 392670
4 March 1996 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 459067
20 November 1995 Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 874787
28 September 1995 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 382963
9 September 1994 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 370443
9 September 1994 MARPOL Annex I Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1176301
8 September 1994 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 370351
2 June 1993 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 358809

Deficiency record · 15

Fire Fighting › Fire Main
Issued 18 March 2002 Resolved
THE FLANGE FOR THE FIRE PUMP IN THE ENGINE ROOM HAD A SOFT PATCH ON IT. HOWEVER FIRE MAIN PREASURE WAS NOT AFFECTED. THE VSL MUST OBTAIN AND SEND A CLASS REPORT TO LOCAL U.S COAST GUARD MSO OR HAVE IT CORRECTED WITHIN 30 DAYS. LEGACY COMPONENT DESC: Condition
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 April 2002
Resolved 10 April 2002
Resolution: CLEARD DEFICIENCY ISSUED ON 18MAR02. REPAIRS FOUND TO BE TO THE SATISFACTION OF MSO TAMPA INSPECTORS.
Navigation
Issued 19 July 2000 Resolved
outdated charts and int'l rules of the raod
Condition: Unknown
Due 22 July 2000
Resolved 25 July 2000
Fire Fighting
Issued 22 December 1999 Resolved
PERMANENTLY REPAIR 2" PENETRATION IN FIRE BOUNDRY WALL SEPARATING STEERING ROOM FROM ENGINE ROOM THROUGH PASSAGEWAY, DECK LEVEL. PERMANENT REPAIRS TO BE MADE TO SATISFACTION OF CLASS.
Condition: Unknown
Due 11 February 2000
Resolved 11 February 2000
Electrical
Issued 22 December 1999 Resolved
PROPERLY TERMINATE/REMOVE EXPOSED WIRING LEADING INTO FWD/STBD LIGHT FIXTURE LOCATED IN BOS'N STORES.
Condition: Unknown
Due 11 February 2000
Resolved 11 February 2000
Fire Fighting
Issued 22 December 1999 Resolved
ALL SELF-CLOSING FIRE DOORS MUST CLOSE COMPLETELY.
Condition: Unknown
Due 23 December 1999
Resolved 23 December 1999
Electrical
Issued 22 December 1999 Resolved
PROPERLY TERMINATE LOOSE WIRING LEADING INTO CONTROL HEAD FOR OWS AUTOMATICCLOSING VALVE.
Condition: Unknown
Due 11 February 2000
Resolved 11 February 2000
Lifesaving
Issued 16 January 1999 Resolved
PORT AND STARBOARD LIFEBOATS MISSING PROPER MARKINGS. MISSING NUMBER OF PASSENGERS
Condition: Unknown
Due 21 May 1999
Resolved 21 May 1999
Lifesaving
Issued 16 January 1999 Resolved
PORT AND STARBOARD LIFEBOATS MISSING PROPER RETROREFLECTIVE TAPE.
Condition: Unknown
Due 21 May 1999
Resolved 21 May 1999
Engineering
Issued 16 January 1999 Resolved
SCAVAGING AIR TRUNK DRAIN VALVE LEAKING OIL
Condition: Unknown
Due 21 May 1999
Resolved 21 May 1999
Fire Fighting
Issued 20 December 1997 Resolved
MAKE PROPER REPAIRS TO LEAKING FIRE MAIN FLANGE AT CARGO HOLD #2 AND TO LEAKING FIRE HYDRANT VALVE BETWEEN CARGO HOLDS #2 AND #3 _x001C_ (SOLAS 74 amd II-2/4). TO BE COMPLETED PRIOR TO RETURNING TO THE U.S. FROMA FOREIGN PORT.
Condition: Unknown
Due 9 April 1998
Resolved 9 April 1998
Navigation
Issued 22 November 1996 Resolved
No means of visual compass readings at emergency steering position as required by Solas 74 Reg 12 (f).
Condition: Unknown
Due 30 April 1997
Resolved 30 April 1997
Fire Fighting
Issued 28 September 1995 Resolved
MAKE PERMANENT REPAIRS TO THE CO2 DISCHARGE LINES AT ALL CARGO HOLDS DISCHARGE POINTS (PIPING FRACTURED AT FITTING DISCHARGE POINT)._x001C_ SOLAS CHPT II-2 REG 53 AND 5(1.3). TO BE COMPLETED PRIOR TO NEXT U.S. PORTCALL FROM A FOREIGN VOYAGE.
Condition: Unknown
Due 5 December 1995
Resolved 5 December 1995
Accommodation/Occupational Safety
Issued 28 September 1995 Resolved
CLEAN ALL FOOD STORAGE AREAS.(DRY STORES AND FREEZERS).
Condition: Unknown
Due 8 March 1996
Resolved 8 March 1996
Documentation
Issued 9 September 1994 Resolved
MISSING TABLE OF LIFESAVING SIGNALS REQUIRED BY SOLAS V, REG 16.
Condition: Unknown
Due 3 October 1995
Resolved 3 October 1995
Fire Fighting
Issued 9 September 1994 Resolved
REQUIRE FIREPROOF LIFELINE FOR FIREFIGHTERS IN ACCORDANCE WITH SOLAS II-2, REGULATION 17.
Condition: Unknown
Due 3 October 1995
Resolved 3 October 1995

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.