Records from 1993 to 2009. Most recent: inspection, 30 March 2009.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 21
30 March 2009
Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3443186
18 October 2005
Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2516369
19 January 2005
Re-Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2276660
12 December 2003
Annual Inspection
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1962426
22 October 2003
Hull Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1932099
10 December 2002
Re-Inspection · MARPOL Annex V Examination · Deficiency Check
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1719657
15 March 2002
Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1493940
5 December 2001
Deficiency Check · COI Inspection · MARPOL Annex V Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1485647
16 October 2001
Hull Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1485605
24 July 2000
Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1433678
30 June 1999
COI Inspection · Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1472353
8 July 1998
Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 805833
1 April 1998
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 787736
30 December 1997
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 783072
31 July 1997
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1414847
14 January 1997
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1099479
25 April 1996
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1082548
18 January 1996
COI Inspection · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1188316
7 June 1995
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1163953
19 December 1994
Plan Review "T" Boat · Hull Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1468332
14 June 1993
Initial Construction-Excluding Oversight · Plan Review "T" Boat · Initial Certification · Hull Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1152001
Engineering › Non-conventional Propulsion/Steering
Issued 10 December 2002
Resolved
Provide a second hose clamp for coolant water hose for air conditioning unit not later than 10 JAN 03. LEGACY COMPONENT DESC: A/C Cooling intake hose connection/clamps
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 January 2003
Resolved 9 January 2003
Resolution: Observed second hose clamp was properly installed.
Lifesaving › Visual Distress Signals (General)
Issued 10 December 2002
Resolved
Provide (3) orange smoke distress signals not later than 10 JAN 03. LEGACY COMPONENT DESC: Condition
Action required: 705 - Other - as specified
Due 10 January 2003
Resolved 9 January 2003
Resolution: Observed new orange smoke signals.
Lifesaving › Lifebuoys
Issued 10 December 2002
Resolved
Provide 60 feet of buoyant lifeline for ring buoy & 3 feet of buoyant line for waterlight lanyard with a corrosion resistant clip not later than 10 JAN 03. LEGACY COMPONENT DESC: Buoyant Lifeline
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 January 2003
Resolved 9 January 2003
Resolution: Observed ring buoy with new buoyant lifeline and waterlight lanyard.
Documentation › Markings/Placards
Issued 17 October 2001
Resolved
Properly mark vessel's name on port & starboard sides of the bow.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 December 2001
Resolved 5 December 2001
Resolution: Corrected.
Communications › Radio Communications › VHF Radiotelephone
Issued 17 October 2001
Resolved
Post an Emergency Radio Broadcast Placard near the helm.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 December 2001
Resolved 5 December 2001
Resolution: Corrected.
Documentation
Issued 24 July 2000
Resolved
PROVIDE A VALID RADIO SAFETY CERTIFICATE AND POST.
Condition: Unknown
Due 24 August 2000
Resolved 5 December 2001
Resolution: Corrected.
Documentation
Issued 24 July 2000
Resolved
PROVIDE THE ORIGINAL CERTIFICATE OF DOCUMENTATION AND KEEP ON BOARD VESSEL.
Condition: Unknown
Due 24 August 2000
Resolved 5 December 2001
Resolution: Corrected.
Lifesaving
Issued 24 July 2000
Resolved
VESSEL IS RESTRICTED TO 6 PASSENGERS UNTIL THE CREW CONDUCTS A SATISFACTORYMAN OVERBOARD DRILL IN THE PRESENCE OF A MARINE INSPECTOR.
Condition: Unknown
Due 24 August 2000
Resolved 5 December 2001
Resolution: Corrected.
Lifesaving
Issued 30 June 1999
Resolved
Stencil children's PFD location and number.
Condition: Unknown
Due 15 July 1999
Resolved 27 July 1999
Accommodation/Occupational Safety
Issued 30 June 1999
Resolved
Install rope guard w/placard to keep passengers off weatherdeck platforms while underway.
Condition: Unknown
Due 15 July 1999
Resolved 27 July 1999
Lifesaving
Issued 30 June 1999
Resolved
Provide two flashlights for emergency lighting.
Condition: Unknown
Due 15 July 1999
Resolved 27 July 1999
Electrical
Issued 30 June 1999
Resolved
Re-route electric bilge pump wiring using metal clamps at 2-foot intervals to raise wire from bilge.
Condition: Unknown
Due 15 July 1999
Resolved 27 July 1999
Deck/Cargo
Issued 30 June 1999
Resolved
Provide 270' of 1-3/4" (circumference) anchor line.
Condition: Unknown
Due 15 July 1999
Resolved 27 July 1999
Lifesaving
Issued 30 June 1999
Resolved
Provide CG-approved first-aid kit.
Condition: Unknown
Due 15 July 1999
Resolved 27 July 1999
Construction/Loadline
Issued 30 June 1999
Resolved
Clean pine needles/debris from bilge.
Condition: Unknown
Due 15 July 1999
Resolved 27 July 1999
Navigation
Issued 30 June 1999
Resolved
Provide applicable excerpts from U.S. Coast Pilot, Tide and Current Tables,and Light LIst, as well as complete Navigation Rules.
Condition: Unknown
Due 15 July 1999
Resolved 27 July 1999
Navigation
Issued 30 June 1999
Resolved
Move all-round light to forward position on house, and disconnect wiring for masthead light.
Condition: Unknown
Due 15 July 1999
Resolved 27 July 1999
Lifesaving
Issued 30 June 1999
Resolved
Apply reflective tape to ring buoys.
Condition: Unknown
Due 15 July 1999
Resolved 27 July 1999
Fire Fighting
Issued 30 June 1999
Resolved
Stow/stencil E/R vent plugs.
Condition: Unknown
Due 15 July 1999
Resolved 27 July 1999
Engineering
Issued 30 June 1999
Resolved
Replace valve handle on port engine cooling water intake.
Condition: Unknown
Due 15 July 1999
Resolved 27 July 1999
Engineering
Issued 30 June 1999
Resolved
Install 1.5"-dia. vent in lazzarette (fuel tank compartment).
Condition: Unknown
Due 15 July 1999
Resolved 27 July 1999
Lifesaving
Issued 30 June 1999
Resolved
Ring buoy: replace 60' of line w/floating line, and install snap hook.
Condition: Unknown
Due 15 July 1999
Resolved 27 July 1999
Documentation
Issued 31 July 1997
Resolved
POST ORIGINAL CERTIFICATE OF INSPECTION.
Condition: Unknown
Due 31 July 1997
Resolved 31 July 1997
Documentation
Issued 31 July 1997
Resolved
PROVIDE ORIGINAL COPY OF THE CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 31 July 1997
Resolved 31 July 1997
Lifesaving
Issued 31 July 1997
Resolved
PROVE PROPER OPERATION OF RING BUOY LIGHT.
Condition: Unknown
Due 31 July 1997
Resolved 31 July 1997
Navigation
Issued 31 July 1997
Resolved
PROVE PROPER OPERATION OF RADIO. VESSEL IS LIMITED TO 1000 FEET FROM SHOREUNTIL CLEARED.
Condition: Unknown
Due 31 July 1997
Resolved 31 July 1997
Documentation
Issued 31 July 1997
Resolved
PROVIDE VALID MASTER'S LICENSE.
Condition: Unknown
Due 31 July 1997
Resolved 31 July 1997
Documentation
Issued 31 July 1997
Resolved
PROVIDE EVIDENCE OF COMPLIANCE WITH CHEMICAL TESTING REQUIREMENTS.
Condition: Unknown
Due 31 July 1997
Resolved 31 July 1997
Construction/Loadline
Issued 31 July 1997
Resolved
COMPLETE CREDIT DRYDOCK EXAMINATION PRIOR TO OPERATION. THIS REQUIREMENT AND REQUIREMENTS #1-#6 ARE TO BE CLEARED PRIOR TO OPERATION.
Condition: Unknown
Due 31 July 1997
Resolved 31 July 1997
Construction/Loadline
Issued 19 December 1994
Resolved
Provide watertight seal for foreward (forepeak) hatch.
Condition: Unknown
Due 19 December 1994
Resolved 19 December 1994
Documentation
Issued 19 December 1994
Resolved
Complete vessel first U.S. Coast Guard reinspection.
Condition: Unknown
Due 19 December 1994
Resolved 19 December 1994
Lifesaving
Issued 19 December 1994
Resolved
Provide proper number and type of children's PFD's.
Condition: Unknown
Due 19 December 1994
Resolved 19 December 1994
Documentation
Issued 19 December 1994
Resolved
Provide new Certificate of Documentation with new owners listed.
Condition: Unknown
Due 20 December 1994
Resolved 20 December 1994