INZENIERIS NECIPORENKO

INZENIERIS NECIPORENKO is a 1976 freight ship. The Coast Guard has recorded 90 inspections since 2001, most recently in February 2024, along with 36 deficiencies and 32 operational controls.

Records from 2001 to 2024. Most recent: inspection, 5 February 2024.

Built
1976
Last inspected
5 February 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7413505 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
MALTA
—
Maury page id
psix-39016

Inspections, by type

…with no type recorded72
Years with a record 7 calendar years (2001–2024)
The 90 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it2536 - Regulatory (Subpart C or D), Net Ton
2536 - Convention (Subpart B), Net Ton
5306 - Dead Weight, Metric Ton
4780 - Displacement, Metric Ton
8454 - Regulatory (Subpart C or D), Gross Ton
8454 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 90

5 February 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7860880
2 April 2006 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2614536
20 October 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2518440
7 August 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2454334
27 April 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2343966
27 April 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2344062
26 April 2005 ISPS II Exam · Ballast Water Examination · PII Safety Exam · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2342983
2 February 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2285246
30 January 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2283074
22 January 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2279034
19 January 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2277280
17 January 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2275998
6 January 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2269778
1 January 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2267160
29 December 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2265940
24 December 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2264365
20 December 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2262604
18 December 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2261704
10 December 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2256871
10 December 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2256930
7 December 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2254667
5 December 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2253463
3 December 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2252759
29 November 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2249414
19 November 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2244312
15 November 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2241335
11 November 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2239239
7 November 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2236186
5 November 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2235376
31 October 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2231706
28 October 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2230018
26 October 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2228683
24 October 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2227054
22 October 2004 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2225229
22 October 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2226279
14 October 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2220823
9 October 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2217178
6 October 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2214907
1 October 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2210777
30 September 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2209561
30 September 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2210063
26 September 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2205236
24 September 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2204236
22 September 2004 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2202557
20 September 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2200198
7 September 2004 ISPS I Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2189086
6 September 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2188165
3 September 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2185348
2 September 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2184371
26 August 2004 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2177152
19 August 2004 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2170375
17 August 2004 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2168340
16 August 2004 In-Service Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2171590
11 August 2004 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2162978
7 August 2004 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2158593
4 August 2004 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2155906
31 July 2004 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2151180
31 July 2004 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2151243
29 July 2004 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2149082
25 July 2004 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2144280
23 July 2004 PII Safety Exam · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2141509
22 July 2004 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2141536
15 July 2004 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2134116
10 July 2004 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2127995
8 July 2004 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2126170
4 July 2004 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2120803
2 July 2004 ISPS II Exam
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2116062
1 July 2004 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2117046
28 June 2004 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2113609
28 June 2004 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2141239
26 June 2004 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2111124
23 June 2004 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2108291
6 April 2004 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2038504
27 March 2004 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2032225
27 March 2004 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2032290
23 February 2004 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2011912
9 February 2004 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2003075
21 January 2004 MARPOL Annex I Examination · Ballast Water Examination · Annual Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1996144
28 September 2003 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1915629
9 August 2003 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1871024
25 July 2003 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1856819
22 July 2003 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1852578
15 July 2003 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1843980
8 July 2003 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1790381
1 July 2003 Re-Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1832235
14 March 2003 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1756802
27 December 2002 Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1723460
12 November 2002 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1704403
8 July 2002 Re-Inspection · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1641452
13 November 2001 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 295497

Deficiency record · 36

Fire Fighting › Fire Main › Condition
Issued 26 April 2005 Resolved
Fire main piping to inlet of main fire pump is holed and wasted. Properly repair to the satisfaction of the Administration or a direct representative of the Flag State (IACS member.)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 April 2005
Lifesaving › Lifeboat › Watertight Enclosure
Issued 26 April 2005 Resolved
There are two holes on both lifeboats located amidship just above the waterline. Provide Flag State report or report from a direct representative of flag (IACS member) attesting to the purpose of these holes and measures that are going to be taken to prevent water intrusion during emergency lifeboat operations
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2024
Resolution: Report attesting to design: provides two holes for paddles. Both holes are protected by canvas covers.
Navigation › Collision/Grounding Avoidance › Radar
Issued 30 September 2004 Resolved
Both radar were inoperative. Repair both radar and sumitt report to Cognizant USCG Sector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 September 2004
Resolution: Received tech report attesting to the proper operation of both radars.
Navigation › Piloting/Steering › Gyro Compass
Issued 22 September 2004 Resolved
Repair gyro compass cooling system piping and send report to cognizant COTP. Replace missing overhead sections in gyro compass room and adjoining passageway.
Action required: 705 - Other - as specified
Due 22 October 2004
Resolved 21 October 2004
Navigation › Piloting/Steering › Gyro Compass
Issued 7 September 2004 Resolved
Repair Gyro Compass. Have technician attest to the satisfactory operation of gyrocompass. Provide tech report prior to departure. Master failed to report their gyro compass inoperable. Requested LOU for 32, 000.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2004
Resolution: Recieved tech report attesting to the proper operation of the gyro compass. New sphere installed # K01037.
Deck/Cargo › Holds/Tanks › Venitlation Fans
Issued 7 September 2004 Resolved
Repair & have class address #2 hold starboard [50(b)] side exhaust fan ventilator. Damage ventilator suffered 4 inch gap at bolted flange. Prior to Oct. 7, 2004.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 November 2004
Resolved 26 October 2004
Resolution: Receivied Calss Survey Report attesting to repairs.
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 23 July 2004 Resolved
Adjust packing of emergency fire pump or replace as necessary
Condition: Improper/Lack of Maintenance
Due 23 August 2004
Resolved 23 August 2004
Resolution: Received Class Report
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 23 July 2004 Resolved
Replace or fix containment for FB7 vent
Condition: Improper/Lack of Maintenance
Due 23 August 2004
Resolved 14 August 2004
Resolution: Received Master report attesting to proper repairs.
Operations/Management › Pollution › Control of Garbage
Issued 23 July 2004 Resolved
Fix incinerator
Due 23 August 2004
Resolved 23 July 2004
Resolution: Received Master report attesting to proper repairs.
Navigation › Piloting/Steering › Gyro Compass
Issued 23 July 2004 Resolved
Repair overheating problem of Gyrocompass and remove illegal wire connected from terminal box 308B Room 236 to blower at Gyro room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 July 2004
Resolution: Received ABS report attesting to proper operation of system
Stability › Unintentional Flooding › General
Issued 23 July 2004 Resolved
Fix leak at rudder post seal and submitt report from class /flag administration attesting to proper repair to USCG inspector
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 July 2004
Resolution: Received ABS report attesting to proper repair
Electrical › Electrical Distribution System (service) › Junction Box
Issued 23 July 2004 Resolved
De-energize terminal box TP-oP at ac room and tape all loose terminals
Due 23 August 2004
Resolved 1 August 2004
Resolution: Received Master report attesting to proper repairs.
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 23 July 2004 Resolved
Replace pulley guards of ac compressors
Due 23 August 2004
Resolved 23 August 2004
Resolution: Received Master report attesting to proper repairs.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 23 July 2004 Resolved
Replace bulkhead cover with required A-60 as per fire control plan two steering gear room aft of starboard bulkhead
Due 23 August 2004
Resolved 23 August 2004
Resolution: Received Master report attesting to repairs.
Fire Fighting › Fire Hoses › Condition
Issued 23 July 2004 Resolved
Change damaged fire hose in portside fire station on bow
Due 23 August 2004
Resolved 24 July 2004
Resolution: Received report from class attesting to the destruction of the fire hose at Fire Staton NO. 17. The replacement hose was placed under full fire main pressure with nozzle attached and considered satisfactory.
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 28 June 2004 Resolved
Vessel did not submit an NOA for the port of St. Thomas. Vessel to depart port and remain outside of U.S. Territoral seas until the requred NOA information is provided, processes and permission is granted for vessel to enter port.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 June 2004
Resolved 28 June 2004
Resolution: def corrected.
Construction/Loadline › Structures
Issued 27 March 2004 Resolved
Provide report from Flag/Class on the repairs required for Port side ventilation riser and hand rails. LEGACY COMPONENT DESC: Ventilators
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 March 2004
Resolved 30 March 2004
Operations/Management › Port and Waterways Safety
Issued 27 March 2004 Resolved
VESSEL FAILEDTO OBEY COTP ORDERS
Due 27 March 2004
Resolved 27 March 2004
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 21 January 2004 Resolved
CO2 Room- Replace water feed pipe insulation to CO2 tank. Class Surveyor to survey all working parts of CO2 system within CO2 room and provide letter attesting to the satisfactory working condition to local USCG [name withheld]: Piping
Condition: Unknown
Due 21 February 2004
Resolved 6 February 2004
Resolution: Insulation of water feed pipe to CO2 tank has been replaced and system survey by Class society. Report filed with MSO San Juan.
Accommodation/Occupational Safety › Refrigeration (air conditioning)
Issued 8 July 2003 Resolved
Make proper repairs to ship A.C. plant to sat of class
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 29 July 2003
Resolved 25 July 2003
Resolution: corrected
Fire Fighting
Issued 8 July 2003 Resolved
Class to attest and review that the ship board fire plan is identical to installation of fire fighting appodtances aboard vessel.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 29 July 2003
Resolved 25 July 2003
Resolution: corrected
Accommodation/Occupational Safety › Occupational Safety
Issued 8 July 2003 Resolved
Captain to conduct inspection of vessel condition IAW Solas I+C, Load Line, Marpol, ILO, Flag rules, Class rules and US regulations. List of inspection Results and deficiencies are to be provvided to RIO St. Croix. All deficiencies are to be repaired to sat of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 29 July 2003
Resolved 25 July 2003
Resolution: corrected
Electrical
Issued 8 July 2003 Resolved
Electrical wire installtion on portside bridge to be IAW IEEE to sat of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 29 July 2003
Resolved 25 July 2003
Resolution: corrected
Lifesaving › Lifeboat
Issued 8 July 2003 Resolved
Reinstall new retro-reflective on life boats. LEGACY COMPONENT DESC: Markings
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 29 July 2003
Resolved 25 July 2003
Resolution: corrected
Engineering › Fuel Oil Service System
Issued 1 July 2003 Resolved
Make permanent repairs to failed asket on fuel oil vent, RO/RO deck IWO STBD. frame 100 to sat. of class. LEGACY COMPONENT DESC: Vent Pipe
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 July 2003
Resolved 10 July 2003
Resolution: corrected
Construction/Loadline › Structures
Issued 1 July 2003 Resolved
Make permanent repairs to tripped frame port side #138 IWO RO/RO deck interface to sat. of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 July 2003
Resolved 10 July 2003
Resolution: corrected
Engineering
Issued 1 July 2003 Resolved
Make permanent repairs to soft patches on EVAP. feed line to sat of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 July 2003
Resolved 10 July 2003
Resolution: corrected
Engineering › Feedwater/Condensate Water System
Issued 1 July 2003 Resolved
Make permanent repairs to MDE feed water line prior to departing St. Croix. LEGACY COMPONENT DESC: Piping
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 July 2003
Resolution: corrected
Engineering › Fuel Oil Storage/Transfer System
Issued 1 July 2003 Resolved
Make permanent repairs to dicharge line from fuel oil double bottom tank #2 to sat. of class. LEGACY COMPONENT DESC: Piping
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 July 2003
Resolved 10 July 2003
Resolution: corrected
Engineering
Issued 1 July 2003 Resolved
Make permanent repairs to cross over line fwd. port main space bulkhead to sat of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 July 2003
Resolved 10 July 2003
Resolution: corrected
Pollution Prevention/Response › Prevention Equipment
Issued 27 December 2002 Resolved
Plugs for containment to all fuel vents on deck are not installed. LEGACY COMPONENT DESC: Fixed Containment
Action required: 705 - Other - as specified
Due 27 January 2003
Resolved 28 December 2002
Resolution: [name withheld] and [name withheld] conducted deficiency check and verified satisfactory repairs.
Construction/Loadline › Structures
Issued 27 December 2002 Resolved
2 soft patches found on main engine port side cooling water lines.
Action required: 705 - Other - as specified
Due 30 January 2003
Resolved 14 March 2003
Resolution: Permanent repairs were conducted on the cooling water lines.
Fire Fighting › Remote Fuel Shutoff
Issued 27 December 2002 Resolved
Emergency generator fuel line shutoff inoperative.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 December 2002
Resolution: [name withheld] and [name withheld] conducted deficiency check and verified satisfactory repairs.
Fire Fighting › Structural - A Class Divisions
Issued 27 December 2002 Resolved
Class "A" fire door to engine room from engine control room has inoperative latch. LEGACY COMPONENT DESC: Openings - Fire Doors
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 December 2002
Resolution: [name withheld] and [name withheld] conducted deficiency check and verified satisfactory repairs.
Electrical › Lighting (emergency)
Issued 27 December 2002 Resolved
Ground in the 220V emergency lighting circuit. LEGACY COMPONENT DESC: Ground Detection
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 December 2002
Resolution: [name withheld] and [name withheld] conducted deficiency check and verified satisfactory repairs.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 27 December 2002 Resolved
No evidence of bi-annual servicing of fixed low pressure CO2 extinguishing system for cargo holds.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 December 2002
Resolution: [name withheld] and [name withheld] conducted deficiency check and verified a updated satisfactory CO2 servicing certificate.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.