MISS JANE TIDE

MISS JANE TIDE is a 2002 offshore supply vessel. The Coast Guard has recorded 1 inspection in 2016, along with 36 deficiencies, 2 operational controls and 4 casualty investigations between 2003 and 2013.

Records from 2003 to 2016. Most recent: operational control imposed, 19 May 2016.

Built
2002
Last inspected
10 May 2016
Documentation
Expired · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9261803
Flag
UNITED STATES
Maury page id
psix-39023

Inspections, by type

Years with a record 1 calendar year (2016)
The 1 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Documentation record

Registered dimensions (L × B × D)232.8 ft × 60.0 ft × 24.6 ft
Registered tonnagegross 3,183 / net 954
ITC dimensions (L × B × D)232.8 ft × 60.0 ft × 24.6 ft
ITC tonnagegross 3,183 / net 954
BuilderQUALITY SHIPYARDS, L.L.C. · HOUMA, LA, UNITED STATES · built 2002
Hull materialSteel
PropulsionDiesel Electric
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationExpired · issued 30 June 2004
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it954 - Convention (Subpart B), Net Ton
3183 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.

Inspection history · 1

10 May 2016 MTSA/ISPS Verification · Deficiency Check · Annual Inspection · Administrative Inspection · ACP Annual Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5873268

Deficiency record · 36

Fire Fighting › Fire Pumps › Arrangement
Issued 16 May 2016 Resolved
During testing of the emergency generator, emergency fire pump was inoperable in either remote mode or manual mode. Prove proper operation of emergency fire pump to the satisfaction of attending USCG marine inspector or ABS Surveyor.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 May 2016
Resolution: Emergency Fire Pump was repaired and retested to the satisfaction of the attending USCG Marine Inspector.
Lifesaving › Lifebuoys › Serviceable
Issued 16 May 2016 Resolved
All ring buoy's on board are not in servicable condition. Replace prior to sailing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 May 2016
Resolution: 08 Ring Buoy's were replaced on board with light/line as required.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 16 May 2016 Resolved
During testing of the watertight doors (2), the indicator panel on the bridge never showed the #2 WTD as fully closed. MI''s conducted a manual test and observed a pool of hydraulic oil near the door. Manual operation of the door was conducted and a 2" gap was still visible when the door was fully closed. Repair and test to the satisfaction of the attending USCG Marine Inspector or ABS Surveyor.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2016
Resolution: Received, reviewed, and accepted class report satisfying the requirement. See report for details dated 03Jun16 ABS class report.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 16 May 2016 Resolved
Port side life raft had an additional line attaching liferaft to the vessel that would not have allowed the liferaft to float free after hydrostatic release was activated. Remove line immediately.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 May 2016
Resolution: Line was cut and removed.
Engineering › Compressed Air System (start air) › Valve
Issued 16 May 2016 Resolved
Air receivers (2) have a 300 psi MAWP with a relief valve setting at 300 psi. The relief valve setting is required to be below the MAWP. The gauge is also maxed out at 300 psi. The gauge is required to be 1.2-2.0 times the setting of the relief valve. The other (2) air receivers have a MAWP of 200 psi. Gauges maxed out at 200 psi. Replace relief valve/gauges and test to the satisfaction.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2016
Resolution: Received, reviewed, and accepted class report satisfying the requirement. See report for details dated 03Jun16 ABS class report.
Lifesaving › Rescue Boat › Hull (rigid)
Issued 16 May 2016 Resolved
During inspection of rescue boat, MIs found unreported damage to several different areas of the hull including port rail, stern, 2' x 2' patch near keel on both port/stbd sides, 2'x3' section of main deck that is buckling, inspector utilized rubber mallet and believes delamination exists in several areas of the hull. Adiditonally, cradle system rubber fendering system aft was removed.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2016
Resolution: Received, reviewed, and accepted class report satisfying the requirement. See report for details dated 03Jun16 ABS class report.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Nozzles
Issued 16 May 2016 Resolved
Vessel's fire water spray system was missing nozzles on fwd portion of pilot house and water curtain by liferafts. Prove proper operation of system to satisfaction of attending USCG MI or ABS Surveyor.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2016
Resolution: Received, reviewed, and accepted class report satisfying the requirement. See report for details dated 03Jun16 ABS class report.
Construction/Loadline › Penetrations › Gasket
Issued 16 May 2016 Resolved
VEssel had WTDs, Water tight hatches, and scuttles all throughout the vessel that were missing and or needed replaced gaskets/sealss. Additionally, inspector noted wastage on knife edge of door at top's. Prove proper repairs/renewal to satisfaction of attending USCG MI or ABS surveyor.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2016
Resolution: Received, reviewed, and accepted class report satisfying the requirement. See report for details dated 03Jun16 ABS class report.
Construction/Loadline › Penetrations › Weld
Issued 16 May 2016 Resolved
Fwd emergency scuttle on forcastle had unreported welding. Inspector observed bad welds and missing gasket. Prove proper repairs to the satisfaction of attending USCG insp or ABS Surveyor.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2016
Resolution: Received, reviewed, and accepted class report satisfying the requirement. See report for details dated 03Jun16 ABS class report.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 16 May 2016 Resolved
Vessel's Fire Detection Panel is showing faults. Provide technician's report proving proper operation of system to the satisfaction of the attending USCG MI or ABS Surveyor.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 May 2016
Resolution: 3rd party technician's report received. System is operating correctly however faults continue to show due to not having the program in order to rename two stations.
Communications › Visual Communication › Signalling Lamp
Issued 16 May 2016 Resolved
Vessel's signaling lamp was found inoperative. Prove proper operation to satisfaction of attending USCG MI or ABS Surveyor.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 May 2016
Resolution: Connections were cleaned, battery recharged, and was tested satisfactory.
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 16 May 2016 Resolved
Vessel's SOLAS Training manual is outdated with equipment not instaled, additionally crew has not signed. Update manual to satisfaction of attending USCG MI or ABS Surveyor.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 June 2016
Resolved 3 June 2016
Resolution: Received, reviewed, and accepted class report satisfying the requirement. See report for details dated 03Jun16 ABS class report.
Deck/Cargo › Ballast › Vents
Issued 16 May 2016 Resolved
Several ballast vent screens need adjustmeent and or are wasted. Make adjustments or repairs to the satisfaction of attending USCG MI or ABS Surveyor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 June 2016
Resolved 3 June 2016
Resolution: Received, reviewed, and accepted class report satisfying the requirement. See report for details dated 03Jun16 ABS class report.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Nozzle
Issued 16 May 2016 Resolved
Inspector noted missing CO2 nozzle in engine room on port side outboard of generator. Provide 3rd party report attesting to the proper installation and operation of the system.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2016
Resolution: Received, reviewed, and accepted class report satisfying the requirement. See report for details dated 03Jun16 ABS class report.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 16 May 2016 Resolved
Inspector noted CO2 pilot bottle hanging from broken bracket for the paint locker, fix/make repairs to the satisfaction of attending USCG MI or ABS Surveyor.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2016
Resolution: Received, reviewed, and accepted class report satisfying the requirement. See report for details dated 03Jun16 ABS class report.
Fire Fighting › Fire Main › Condition
Issued 16 May 2016 Resolved
Inspector noted broken bracket on the installed fire piping at station 13 on main deck, make repairs to the satisfaction of attending USCG MI or ABS Surveyor.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2016
Resolution: Received, reviewed, and accepted class report satisfying the requirement. See report for details dated 03Jun16 ABS class report.
Engineering › Freshwater Generation System › Heat Exchanger
Issued 16 May 2016 Resolved
Inspector noted hot water heater in engine room had no relief valve installed. Prove proper installation to satisfaction of attending USCG MI or ABS Surveyor.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2016
Resolution: Received, reviewed, and accepted class report satisfying the requirement. See report for details dated 03Jun16 ABS class report.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 16 May 2016 Resolved
Vessel is missing Alchol testing strips as required by company'd DAPI. Place required equipment on board.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 June 2016
Resolved 3 June 2016
Resolution: Received, reviewed, and accepted class report satisfying the requirement. See report for details dated 03Jun16 ABS class report.
Communications › Radio Communications › EPIRB
Issued 16 May 2016 Resolved
Vessel's EPIRB registration shows EPIRB as a cateogry II when the EPIRB is indeed a category I. Update accordingly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 June 2016
Resolved 3 June 2016
Resolution: Received, reviewed, and accepted class report satisfying the requirement. See report for details dated 03Jun16 ABS class report.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 16 May 2016 Resolved
Vessel's Fire and Safety Plan has (2) EPIRBS listed. Conduct walkthrough of entire plan, submit changes to the satisfaction of attending ABS Surveyor.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 June 2016
Resolved 3 June 2016
Resolution: Received, reviewed, and accepted class report satisfying the requirement. See report for details dated 03Jun16 ABS class report.
Documentation › Markings/Placards › Warning Signs
Issued 16 May 2016 Resolved
IMO symbols missing/faded throughout the vessel including signaling lamp, first aid kit, fire stations, etc... place appropriate symbols in accordance with Fire/Safety Plan.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 June 2016
Resolved 3 June 2016
Resolution: Received, reviewed, and accepted class report satisfying the requirement. See report for details dated 03Jun16 ABS class report.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 16 May 2016 Resolved
Not under command navigational light is inoperable. Repair to the satisfaction of attending USCG MI or ABS Surveyor.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 May 2016
Resolution: Bulb was replaced and satisfactory retested.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 16 May 2016 Resolved
5 year load test provided to the USCG was not conducted using the minimum and maximum boom angles per the vessel load chart. 46 CFR 126.130/107.260 NLT next drydock
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 10 August 2016
Resolved 3 June 2016
Resolution: Received, reviewed, and accepted class report satisfying the requirement. See report for details dated 03Jun16 ABS class report.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 16 May 2016 Resolved
Vessels freezer door lock was noted as inoperative, during spot checks. Prove proper operation to satisfaction of the attending inpector or ABS. ABS Class Rules or USCG
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 3 June 2016
Resolution: Received, reviewed, and accepted class report satisfying the requirement. See report for details dated 03Jun16 ABS class report.
Accommodation/Occupational Safety › Occupational Safety › Welding/Hot Work
Issued 16 May 2016 Resolved
Vessels oxygen and acetylene bottles were not stowed properly. Bottles need to be stowed off the deck and with the protective caps while not in use. Prove proper operation to satisfaction of the attending inpector or ABS. ABS Class Rules or USCG
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 3 June 2016
Resolution: Received, reviewed, and accepted class report satisfying the requirement. See report for details dated 03Jun16 ABS class report.
Construction/Loadline › Structures › Superstructure
Issued 16 May 2016 Resolved
Inspector noted wastage on the top knife edge sealing surface of the acetylene WTD. Make repairs to satisfaction of the attending inpector or ABS. ILLC/ABS Class Rules
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 3 June 2016
Resolution: Received, reviewed, and accepted class report satisfying the requirement. See report for details dated 03Jun16 ABS class report.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 16 May 2016 Resolved
Vessels stbd F/O valve on deck was inoperative and had signs of damaged. Renew/Prove proper operation to satisfaction of the attending inpector or ABS. ABS Class Rules or USCG
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 3 June 2016
Resolution: Received, reviewed, and accepted class report satisfying the requirement. See report for details dated 03Jun16 ABS class report.
Construction/Loadline › Penetrations › Pipe Flange
Issued 16 May 2016 Resolved
Inspector noted soft patch on (Barite) piping line near aft portside of deck area. Renew/Prove proper installation to satisfaction of the attending inpector or ABS. ABS Class Rules or USCG
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 3 June 2016
Resolution: Received, reviewed, and accepted class report satisfying the requirement. See report for details dated 03Jun16 ABS class report.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Manifold
Issued 16 May 2016 Resolved
Several of the containments on the aft deck were missing plugs. Provide missing containment plugs for aft deck area. Prove proper operation to satisfaction of the attending inpector or ABS. ABS Class Rules or USCG
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 3 June 2016
Resolution: Received, reviewed, and accepted class report satisfying the requirement. See report for details dated 03Jun16 ABS class report.
Electrical › Lighting (service) › Lighting Fixture
Issued 16 May 2016 Resolved
Vessel had several lighting fixture on the exterior aft deck that were not electrically safe. Renew or replace damaged or missing stuffing connections on lighting fixtures, to satisfaction of the attending inpector or ABS. SOLAS Chp II/1 45 ABS Class Rules or USCG
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 3 June 2016
Resolution: Received, reviewed, and accepted class report satisfying the requirement. See report for details dated 03Jun16 ABS class report.
Engineering › Fuel Oil Service System › Piping
Issued 16 May 2016 Resolved
Inspector noted F/O leak on the incinerator return line, and several other suspected soft patches on F/O lines within the engine room. Prove proper installation and operation to satisfaction of the attending inpector or ABS. Marpol VI/SOLAS I/11 ABS Class Rules or USCG
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 3 June 2016
Resolution: Received, reviewed, and accepted class report satisfying the requirement. See report for details dated 03Jun16 ABS class report.
Engineering › Diesel Engine (propulsion-electric) › Valve
Issued 16 May 2016 Resolved
Vessels 1-3 SSDG's were missing F/O and L/O sample valve handles and plugs. Renew, replace, and prove proper operation to satisfaction of the attending inpector or ABS. ABS Class Rules or USCG
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 3 June 2016
Resolution: Received, reviewed, and accepted class report satisfying the requirement. See report for details dated 03Jun16 ABS class report.
Engineering › Diesel Engine (propulsion-electric) › Silencer (exhaust)
Issued 16 May 2016 Resolved
Inspector observed multiple exhaust leaks in the engine room. Prove proper installation and operation to satisfaction of the attending inpector or ABS. ABS Class Rules or USCG
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 3 June 2016
Resolution: Received, reviewed, and accepted class report satisfying the requirement. See report for details dated 03Jun16 ABS class report.
Engineering › Fuel Oil Service System › Piping
Issued 16 May 2016 Resolved
Inspector oberved and noted several missing SOLAS tape on high pressure fitting on 1-3 SSDG's. Additionally, several F/O hoses near the F/O strainers were damaged and in need of replacement. Renew, replace, and prove proper installation to satisfaction of the attending inpector or ABS. SOLAS I/11 ABS Class Rules or USCG
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 3 June 2016
Resolution: Received, reviewed, and accepted class report satisfying the requirement. See report for details dated 03Jun16 ABS class report.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 16 May 2016 Resolved
Vessels port crane safety limit switch was reported and found inoperative. Prove proper operation to satisfaction of the attending inpector or ABS. SOLAS I/11 ABS Class Rules or USCG
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 3 June 2016
Resolution: Received, reviewed, and accepted class report satisfying the requirement. See report for details dated 03Jun16 ABS class report.
Documentation › Safety Management System › Master's Authority/Responsibility Documentation
Issued 16 May 2016 Resolved
During Annual ACP examination 35 835's were issued, 9 of which were serious no sail items. Based on the finding during this examination, the RO and ABS shall conduct an external audit of the SMS related to the vessels Lifesaving, fire-fighting, Loadline items, and procedures for notifying company (DPA). The results of the audit shall be submitted to Sector NOLA. SOLAS IX/4 Reg 3 ISM Code 6
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 May 2016
Resolved 3 June 2016
Resolution: Received, reviewed, and accepted class report satisfying the requirement. See report for details dated 03Jun16 ABS class report.

Casualty record · 4

12 March 2003Routine · role: Involved in a Marine Casualty · 1 injured · activity 1767662
24 November 2004Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2254052
18 October 2009Routine · role: Involved in a Marine Casualty · activity 3694052
2 February 2013Routine · role: Involved in a Marine Casualty · activity 4540015
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.